APC Back-UPS 550 Bedienungsanleitung
Lesen Sie kostenlos die đ deutsche Bedienungsanleitung fĂŒr APC Back-UPS 550 (2 Seiten) in der Kategorie UPS. Dieser Bedienungsanleitung war fĂŒr 36 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet
Seite 1/2
Safety
Specifications
Connect the Battery
The Back-UPS is shipped with one battery cable disconnected. Remove the âStop!
Connect the Batteryâ label that covers the outlets. Prior to connecting any equipment
to the unit, connect the battery cable to the unused battery terminal. It is normal for
small sparks to be seen when the battery cable is connected to the battery terminal.
Wall Mount Installation
âą Horizontal installation, use 2 screws 7.3" (186.3 mm) apart.
âą Vertical installation, use 2 screws 5.4" (137.2 mm) apart.
âą Allow 5/16" (8 mm), of the screw to protrude from the wall.
Replace Battery
Use only approved APC replacement battery cartridges.
Deliver used batteries to a battery replacement facility in the packaging provided by
APC with the replacement battery cartridge. To order replacement battery cartridges
contact APC.
Connect Equipment
Battery Backup + Surge Protection Outlets
Battery backup outlets provide protection to connected equipment when the
Back-UPS is turned on and connected to utility power.
Battery backup outlets receive power from the Back-UPS for a limited period of time
when a power outage, or brownout condition occurs.
Battery backup outlets provide protection from power surges or spikes.
Connect a computer, monitor and other peripheral devices to the outlets.
Surge Protection Outlets
Surge protection outlets provide protection to connected equipment when the
Back-UPS is connected to utility power, and is switched on or off.
Surge protection outlets provide protection from power surges or spikes.
Connect a printer, scanner or other peripheral devices that do not need to remain on
during power outages, or utility problems to the surge protection outlets.
Connect Network
The Back-UPS protects equipment connected to a 10/100 Base-T ethernet, from
power surges when connected through the Back-UPS coaxial connectors.
PowerChuteÂź Personal Edition Software
Overview
Use PowerChute Personal Edition software to configure the UPS settings.
Protect your computer and other equipment during a power outage. During a power
outage, PowerChute will save any open files on your computer and safely shut it
down. When power is restored, it will restart the computer.
Configure the UPS to use features such as power-saving outlets, shutdown
configuration, and alarms.
Monitor the UPS for power usage and power events.
Note: PowerChute is only compatible with a Windows operating system. If you are
using a Mac OSX, use the native shutdown feature to protect your system. See the
documentation provided with your computer.
Installation
Use a USB cable to connect the Data port on the rear panel of the UPS to the USB port
on your computer.
If the Back-UPS came with CD into your computer and a PowerChute CD, insert the
follow the on-screen instructions
If the Back-UPS did not come with a PowerChute CD, go to www.apc.com and
download the software free of charge.
Turn On the Back-UPS
Press the POWER ON button located on the top of the Back-UPS. The Power On/
Replace Battery LED will illuminate and a single short beep will be audible to
indicate that the Back-UPS is providing protection for connected equipment.
The Back-UPS battery charges fully during the first 16 hours while connected to
utility power. The Back-UPS battery will charge while the Back-UPS is switched on
or off and is connected to utility power. Do not expect full battery run capability
during the initial charge time.
If the red Building Wiring Fault LED located on the side of the Back-UPS
illuminates, do not operate the Back-UPS. Have a qualified electrician correct the
building wiring fault.
Warranty
The standard warranty is 3 years in the USA and Canada, 2 years in all other regions
from the date of purchase. APC standard procedure is to replace the original unit with
a factory reconditioned unit. Customers who must have the original unit back due to
assigned asset tags and set depreciation schedules must declare such a need at first
contact with APC Technical Support. APC will ship the replacement unit once the
defective unit is received by the repair department or cross-ship upon the provision of
a valid credit card number. The customer pays for shipping to APC, and APC pays
ground freight transportation costs back to the customer.
This unit is intended for indoor use only.
Do not operate this unit in direct sunlight, in
contact with fluids, or where there is excessive
dust or humidity.
Connect the Back-UPS power cord directly to a
wall outlet. Do not use a surge protector or an
extension cord.
Input
Voltage 120 Vac Nominal
Frequency 60 Hz + 3
Brownout Transfers 92 Vac Typical
Over-voltage Transfer 139 Vac Typical
Output
UPS Capacity
(4 battery backup outlets) BE450G: 450 VA, 257 W;
BE550G: 550 VA, 330 W;
BE650G1: 650 VA, 390 W
Total Amperage (all outlets) 12 A (including UPS output)
Voltage - On Battery 115 Vac ± 8%
Frequency - On Battery 60 Hz + 1
Transfer Time 6 ms Typical, 10 ms maximum
Protection
and
Filtering
AC Surge Protection Full time, 340 Joules
EMI/RFI Filter Full time
AC Input Resettable circuit breaker
Battery
Type Sealed, maintenance-free, lead acid
BE450G: RBC114
BE550G: RBC110
BE650G1: RBC17
Average Life 3 - 5 years depending on the number of
discharge cycles and environmental
temperature
Physical
Net Weight Replacement battery cartridge
BE450G: 10 lb (4.7 kg)
BE550G: 12 lb (5.5 kg)
BE650G1: 14 lb (6.2 kg)
Dimensions
Length x Width x Height 12 in x 7 in x 3 in
30 cm x 18 cm x 9 cm
Operating Temperature 32Âș F to 104Âș F (0Âș C to 40Âș C)
Storage Temperature 5Âș F to 113Âș F (â15Âș C to 45Âș C)
Operating Relative Humidity 0 to 95% non-condensing humidity
Operating Elevation 0 to 10,000 ft (0 to 3000 m)
EMC
Compliance
This device complies with part 68 and part 15 of the FCC rules.
Operation is subject to the following two conditions: (1) This device
may not cause harmful interference, and (2) This device must accept any
interference received, including interference that may cause undesired
operation.
ï± Press the battery compartment cover
release tab located on the rear side of the
unit. Slide the battery cover off.
ïČ Connect the battery cable securely to the
battery terminal.
ïł Reinstall the battery compartment cover.
Be sure that the release tab locks into place.
bu064a
bu065a
bu066a
bu202a
Back-UPS
Battery Backup + Surge Protection
Surge Protection
bu201a
CAUTION-Refer to bottom
of unit for safety markings.
Circuit
Breaker
Building
Wiring Fault
PowerChute
USB Port
Network
Out
Push to
Reset
Network
In
User Manual Back-UPSÂź BE 450G/550G/650G1
990-3951B
7/2011
© 2011 APC by Schneider Electric. APC, the APC logo, Back-UPS and PowerChute are owned by Schneider Electric Industries S.A.S., American Power Conversion Corporation,
or their affiliated companies. All other trademarks are property of their respective owners.
Status Indicators
Troubleshooting Voltage Sensitivity Adjustment (optional)
The Back-UPS detects and reacts to line voltage distortions by transferring to battery
backup power to protect connected equipment. In situations where either the Back-UPS
or the connected equipment is too sensitive for the input voltage level it is necessary to
adjust the transfer voltage.
1. Connect the Back-UPS to a wall outlet. The Back-UPS will be in Standby mode, no
indicators will be illuminated.
2. Press and hold the ON/OFF button for 10 seconds. The OnLine LED will
illuminate alternately green-amber-red, to indicate that the Back-UPS is in
Program mode.
3. The Power On/Replace Battery LED will ïŹash either green, amber, or red to
indicate the current sensitivity level. Refer to the table for an explanation of the
transfer voltage sensitivity levels.
4. To select LOW sensitivity, press and hold the ON/OFF button until the LED flashes
green.
5. To select MEDIUM sensitivity, press and hold the ON/OFF button until the LED
flashes red.
6. To select HIGH sensitivity, press and hold the ON/OFF button until the LED flashes
amber.
7. To exit Program mode wait five seconds and all LED indicators will extinguish.
Program mode is no longer active.
Service
If the unit requires service, do not return it to the dealer. Follow these steps:
1. Review the Troubleshooting section of the manual to eliminate common problems.
2. If the problem persists, contact APC Customer Support.
a. Note the model number and serial number and the date of purchase. The model
and serial numbers are located on the rear panel of the unit and are available
through the LCD display on select models.
b. Call APC Customer Support and a technician will attempt to solve the problem
over the phone. If this is not possible, the technician will issue a Returned
Material Authorization Number (RMA#).
c. If the unit is under warranty, the repairs are free.
d. Service procedures and returns may vary internationally. Refer to the APC Web
site for country speciïŹc instructions.
3. Pack the unit properly to avoid damage in transit. Never use foam beads for
packaging. Damage sustained in transit is not covered under warranty. Always
DISCONNECT THE UPS BATTERY before shipping in compliance with U.S.
Department of Transportation (DOT) and IATA regulations. The battery may
remain in the unit.
4. Write the RMA# provided by Customer Support on the outside of the package.
5. Return the unit by insured, pre-paid carrier to the address provided by
Customer Support.
Contact
APC Web site, www.apc.com
Status LED Indicator Audible Indicator On Audible Indicator Terminates
Power On
The Back-UPS is supplying utility power to connected equipment. The green LED illuminates. None N/A
On Battery
Back-UPS supplying battery power to battery backup outlets.
The green LED illuminates. The LED
is not illuminated during the beeps. Back-UPS beeps 4
times every 30 seconds. Beeping stops when utility power is restored or
the Back-UPS is turned off.
Low Battery warning
The Back-UPS is supplying battery power to the battery backup outlets
and the battery is near a total discharge state.
The green LED illuminates with rapid
green flashes.
The Back-UPS emits
rapid beeping, every
1/2 second.
Beeping stops when utility power is restored or
the Back-UPS is turned off.
Replace Battery
âą The battery is disconnected.
âą The battery needs to be charged, or replaced.
âąReplace Battery LED flashes.
âą Replace Battery and Power On
LEDs flash alternately.
Constant tone
Constant tone Back-UPS is turned off.
Overload Shutdown
While on battery power an overload condition has occurred in one or
more of the battery backup outlets while the Back-UPS is operating on
battery power.
None Constant tone Back-UPS is turned off.
Sleep Mode
While on battery power the battery is completely discharged. The
Back-UPS will âawakenâ once utility power is restored. None
The Back-UPS beeps
once every four
seconds.
The beeping stops when:
âą Utility power is restored
âą If utility power is not restored within 32 seconds
âą The Back-UPS is turned off
Building Wiring Fault
The building wiring presents a shock hazard that must be corrected by a
qualified electrical.
Building Wiring Fault LED
illuminates red
None The Back-UPS is unplugged from the wall outlet
or is plugged into an improperly wired outlet.
Problem and Possible Cause Solution
The Back-UPS will not turn on
The Back-UPS has not been turned
on. Press the POWER ON button.
The Back-UPS is not connected to
utility power, there is no utility power
available at the wall outlet, or the
utility power is experiencing a
brownout or over voltage condition.
Make sure the power cord is securely connected to
the wall outlet, and that there is utility power
available at the wall outlet.Where applicable,
check that the wall outlet is switched on.
The battery is not connected. Connect the battery. Refer to âConnect the
Batteryâ on page 1 of this manual.
In the event that the Back-UPS receives no utility
power and the battery is connected, a cold-start can
be initiated. Press and hold the Power On button
until the Back-UPS emits two beeps.
The Back-UPS is on, the Replace Battery LED flashes and the unit emits a
constant tone
The battery is disconnected. Refer to the âConnect the Batteryâ on page 1.
Connected equipment loses power
A Back-UPS overload condition has
occurred.
Remove all nonessential equipment connected to
the outlets. One at a time reconnect equipment to
the Back-UPS.
The Back-UPS battery is completely
discharged.
Connect the Back-UPS to utility power and allow
the battery to recharge for eight hours.
PowerChute software has performed a
shutdown due to a power failure.
This is normal Back-UPS operation.
Connected equipment does not accept
the step-approximated sine waveform
from the Back-UPS.
The output waveform is intended for computers
and peripheral devices. It is not intended for use
with motor driven equipment.
The Back-UPS may require service. Contact APC Technical Support for more in depth
troubleshooting.
The Power On LED is illuminated and the Back-UPS beeps 4 times every 30
seconds
The Back-UPS is operating on battery
power.
The Back-UPS is operating normally on battery
power. At this point the user should save all open
files, and shutdown the computer. When utility
power is restored the battery will recharge.
The Power On LED flashes once every second while the Back-UPS beeps once
every second
The Back-UPS battery has
approximately two minutes of
remaining runtime.
The Back-UPS battery is near a total discharge
state. At this point the user should save all open
files, and shutdown the computer. When utility
power is restored the battery will recharge.
The Building Wiring Fault LED illuminates
The building wiring presents a shock
hazard that must be corrected by a
qualified electrical.
Do not operate the Back-UPS. Call a qualified
electrician to correct the building wiring fault.
The Back-UPS has an inadequate battery runtime
The battery is not fully charged.
The battery is near the end of useful
life and should be replaced.
Leave the Back-UPS connected to utility power for
16 hours while the battery charges to full capacity.
As a battery ages, the runtime capability decreases.
Contact APC at the Web site www.apc.com, to
order replacement batteries.
The connection from the Back-UPS to the internet is lost during a power
outage
The modem has lost power. Connect the modem cable into one of the Battery
Backup + Surge Protection outlets.
LED
Flashes
Sensitivity
Setting
Input Voltage Range
(Utility Operation) Recommended Use
Green LOW 88 Vac to 142 Vac Use this setting with equipment that is less
sensitive to fluctuations in voltage or
waveform distortions.
Red MEDIUM 92 Vac to 139 Vac Factory default setting. Use this setting
under normal conditions.
Amber HIGH 96 Vac to 136 Vac Use this setting when connected equipment
is sensitive to voltage and waveform
fluctuations.
Produktspezifikationen
Marke: | APC |
Kategorie: | UPS |
Modell: | Back-UPS 550 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit APC Back-UPS 550 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung UPS APC
13 Oktober 2024
13 Oktober 2024
13 Oktober 2024
13 Oktober 2024
13 Oktober 2024
13 Oktober 2024
13 Oktober 2024
13 Oktober 2024
5 Oktober 2024
3 Oktober 2024
Bedienungsanleitung UPS
- UPS Approx
- UPS Gembird
- UPS HP
- UPS Voltcraft
- UPS AEG
- UPS Siemens
- UPS IKEA
- UPS Dell
- UPS LC-Power
- UPS Tripp Lite
- UPS GYS
- UPS Adj
- UPS Block
- UPS Digitus
- UPS CyberPower
- UPS Eaton
- UPS EnerGenie
- UPS Emerson
- UPS Furman
- UPS Riello
- UPS Puls Dimension
- UPS Avocent
- UPS Atlantis Land
- UPS Vanson
- UPS Phoenix Contact
- UPS Minuteman
- UPS V7
- UPS Equip
- UPS Salicru
- UPS SurgeX
- UPS Bxterra
- UPS Altronix
- UPS FSP
- UPS Ditek
- UPS PowerWalker
- UPS FSP/Fortron
- UPS East
- UPS Liebert
- UPS Murr Elektronik
- UPS Online USV
Neueste Bedienungsanleitung fĂŒr -Kategorien-
11 Oktober 2024
9 Oktober 2024
9 Oktober 2024
4 Oktober 2024
3 Oktober 2024
3 Oktober 2024
3 Oktober 2024
3 Oktober 2024
3 Oktober 2024
2 Oktober 2024