Andrews PAC60 Bedienungsanleitung


Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Andrews PAC60 (16 Seiten) in der Kategorie Klimaanlage. Dieser Bedienungsanleitung war für 4 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/16
Page 1
HANDBOOK FOR PAC60/HEX60,
THREE PHASE 400V 50Hz
CACA
CACA
CAUTIONUTION
UTIONUTION
UTION
PLEASE READ THIS LEAFLET CAREFULLY
INTERNAL ACCESS SHOULD BE RESTRICTED TO ANDREWS TRAINED STAFF ONLY.
SD259758 Iss B.
1. DO NOT APPLY MAINS WATER PRESSURE TO PAC UNITS. ACCESS TO THE
FILLING POINT FOR THE WATER CIRCULATING SYSTEM IS IN THE TOP OF THE
HEAT EXCHANGER UNIT.
2. WHEN REMOVING A PAC UNIT FROM AN INSTALLATION DISCONNECT WATER
QUICK COUPLINGS AT ROOM UNIT FIRST.
Page 2
Page 3
1)HEALTH & SAFETY AT WORK ACT
1974
Under section 6 of the above Act, it is the
duty of the manufacturers and suppliers of
the products for use at work to ensure, so
far it is reasonably practicable, that such
products are safe without risk to health
when properly used and to make available
to users of such products adequate
information about their safe and proper
operation.
Air conditioners should only be used in the
manner and purpose for which they were
intended and in accordance with the
recommendations detailed in this leaflet.
Our air conditioners have been designed,
produced and inspected with safety in
mind, but there are certain basic
precautions which should be taken by the
user and in particular attention is drawn to
the safety precaution in this leaflet.
It is imperative, therefore, that all persons
who may make use of our equipment have
all the information and instructions they
require to ensure that they are fully aware
of any hazards, and that they know both
the purpose and the correct manner of the
use of the equipment.
GENERAL SAFETY
This equipment should only be operated
by a competent adult who has read and
understood these instructions.
Never operate this equipment if you are ill,
feeling tired or under the influence of
alcohol or drugs.
Never put anything on top of the unit or
block the air inlets or outlets.
Make sure equipment is switched off and
unplugged after use.
Check condition of equipment before use.
If unit is showing signs of damage contact
your supplier immediately.
WARNINGS !
*This unit MUST be transported and
operated in the upright position at all
times.
*Do not operate this equipment if it has
missing, damaged, insecure guards or
electrical components.
*Ensure equipment is sited on firm level
ground.
*Locate away from any possible
unauthorised interference.
*Ensure electrical supplies are of
adequate capacity.
*The user must not undertake any
service or repair of equipment.
*Ensure debris or detritus cannot be
drawn into the outdoor unit fan’s airflow.
ANY DOUBT CONCERNING
APPLICATION / INSTALLATION
CONSULT YOUR SUPPLIER.
2)INSTALLATION.
ELECTRICAL SUPPLY
All electrical installations must comply
with current IEE regulations.
As standard, this unit requires a 25 Amp
fused electrical supply rated at 400Volts,
~3N, 50Hz.
The unit will operate from a 32A, 3 phase
wall socket.
Do not run umbilical in lying water.
Do not disconnect plugs until the mains
supply has been isolated.
Ensure floor surface is adequate for the
weight.
Ensure the outdoor unit (hex) is safely
located on a level surface with the wheels
locked, away from possible unauthorised
interference.