AFX Arlo ARLV330424L35D1SN Bedienungsanleitung

AFX Erleichterung Arlo ARLV330424L35D1SN

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für AFX Arlo ARLV330424L35D1SN (1 Seiten) in der Kategorie Erleichterung. Dieser Bedienungsanleitung war für 7 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/1
LED Indoor Luminaires Model # ARLV250418L35D1 SN
Wall Mount ARLV330424L35D1SN
120VAC / 60Hz
Page 1 of 1 8061190 R1
Limited Factory Warranty
AFX Inc. hereby warranty that this xture is free from defects in materials and workmanship when installed and used under normal operating conditions for a period of 5 years
from date of shipment from factory. This warranty covers all component parts and extends only to replacement of defective xture or components; it does not cover failure due
to improper installation, misuse, mishandling or damage incurred in transit.
Safety Precautions
 Read all safety precautions and installation instructions carefully before installing or servicing this xture. Failure to comply with these instructions could result in potentially fatal
electric shock and/or property damage.
 It is recommended that a qualied electrician perform all wiring. This xture must be wired in accordance with all national and local electrical codes.
 Do not handle any energized xture or attempt to energize any xture with wet hands or while standing on a wet or damp surface or in water.
 This xture is designed for use in a 120VAC, 60Hz fused circuit. The xture is compatible with Triac or ELV dimmers. Make sure that the power source conforms to the requirements
of the fixture. (See labels on the fixture housing).
 To reduce the risk of electrical shock, and to assure proper operation, this xture must be adequately grounded. To accomplish proper grounding, there must be a separate ground
wire (green) contact between this xture and the ground connection of your main power supply panel.
 This xture is intended to be used for general door lighting in locations.in dry or damp
 Disclaimer
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTE: This equipment has been
tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules and Canadian ICES- -005 (B). These limits are designed to 005 (B) / NMB
provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment o and on, the user is encouraged
to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiver antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult with the dealer or an experienced radio/TV technician for help.
Any modications to this xture may void the warranty and interfere with the safe operation of the luminaire.
Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may
cause undesired operation of the device.
Assembly Instructions
1. Preparing for installation.
A. Disconnect electrical power before installing or
servicing any part of this xture
B. components Remove fixture from carton; remove from
hardware kit.
C. Install mounting bracket (1) to the junction box (not
included) with two - screws (2 For additional #8 32 ).
support, use wood screws (4) to secure to wood stud.
If wood stud is not directly behind the bracket, then
drill Ø0.25 hole through the drywall to install plastic
anchors (3) for use with wood screws.
2. Wiring.
All wiring must take place inside junction box. Caution:
Make sure power is o at fuse or circuit breaker box. Check
power wires for damage or scrapes. If the power supply
wires are within three inches of the v use dri er, a wire
suitable for at least 90C (194F). Most dwellings built Note:
before 1985 have supply wire rated to 60C. Consult a
qualied electrician before installing.
A. This unit will not operate properly unless connected to
a “grounded” electrical circuit. Electrical shock, over
heating, low or no light output, and shortened LED life
can result if proper grounding is not done. Securely
attach power source ground wire and xture green
ground wire to green ground screw on mounting bracket.
B. Make all wire connections to appropriate wire. Secure with wire nuts (provided).
C. Connect white fixture lead to white (N) wire from supply power source. Connect black fixture lead to black (L) wire from supply
power source.
D. For Triac dimming xture. Connect white xture lead to white (N) wire from supply power source. Connect black xture lead
to black (L) wire from dimmer supply power source.
E. Do not mix wires. Pull on each wire lead to make sure connections are secure. Make certain no bare wires are exposed outside of wire connectors Tuck all connections neatly .
into junction box.
3. Fixture mounting.
A. Install xture (5 to mounting bracket by aligning holes on top and bottom using four screws (6 secure . ) ) to it
4. Power to the xture can now be restored.
ARLV330424L35D1SN
MODEL SHOWN


Produktspezifikationen

Marke: AFX
Kategorie: Erleichterung
Modell: Arlo ARLV330424L35D1SN

Brauchst du Hilfe?

Wenn Sie Hilfe mit AFX Arlo ARLV330424L35D1SN benĂśtigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Erleichterung AFX

Bedienungsanleitung Erleichterung

Neueste Bedienungsanleitung fĂźr -Kategorien-