AEG SNMP Bedienungsanleitung


Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für AEG SNMP (27 Seiten) in der Kategorie Nicht kategorisiert. Dieser Bedienungsanleitung war für 11 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/27
Version: 1.6.1 2016- - 10 04
1
CS141 User Manual
English
UPS WEB/SNMP MANAGER
Copyright Statement for Intellectual Property and Confidential Information
The information contained in this manual is non-conditional and may be changed without due
notice. Although Generex has attempted to provide accurate information within this document,
Generex assumes no responsibility for the accuracy of this information.
Generex shall not be liable for any indirect, special, consequential, or accidental damage
including, without limitations, lost profits or revenues, costs of replacement goods, loss or
damage to data arising out of the use of this document.
Generex the manufacturer of the BACS products undertakes no obligations with this
information. The products that are described in this brochure are given on the sole basis of
information to its channel partners for them to have a better understanding of the Generex
products.
Generex allows its channel partners to transfer information contained in this document to third
persons, either staff within their own Company or their own customers, either electronically or
mechanically, or by photocopies or similar means. Generex states that the c ontent must not be
altered or adapted in any way without written permission from Generex.
It is agreed that all rights, title and interest in the Generex’s trademarks or trade names
(whether or not registered) or goodwill from time to time of Generex or in any intellectual
property right including without limitation any copyright, patents relating to the Products, shall
remain the exclusive property of Generex.
Generex will undertake to deal promptly with any complaints about the content of this
document. Comments or complaints about the document should be addressed to Generex
Systems GmbH.
Copyright of the European Union is effective (Copyright EU).
Copyright (c) 1995-2016 GENEREX GmbH, Hamburg, Germany. All rights reserved.
7 Port occupancy
8 Port description
9 LED Status
Commissioning
10
Network integration
11 Hardware- and Firmware informations
12 Timeserver
13 U selectionPS
14 UPS function
15 Email configuration
16 Email Traps
17 Events and alerts
18 RCCMD-Signals
19 SNMP
20 MODBUS
21 Log files
Miscellaneous
22 Firmware Update
23 Backup & Restore
24 Tools
25 External devices
26 Rescue System
27 Sensors
28 Diagnostics
29 FAQ
30 Manual version
The CS141 is the successor of the triumphant CS121. Beside an upgraded technology more functions and possibilities are
added to the devices.
2. Changes in comparison to predecessor CS121
The menu architecture was remodeled completely. The easier-to-handle-interface allows a massive
comparison.
While the CS121 needed a reboot after changing the configuration, it is no longer necessary with th
configuration will be written in the system within seconds.
The CS141 has two additional user accounts, engineer and guest. These accounts have restricted r
change the UPS model, create jobs but cannot change system settings like email settings, time serv
He can look at the log files. The guest can only view the UPS status, firmware and uptime.
Both DIP-Switches have been removed. Instead there is only one Switch on the device on the front.
is changed, a reboot has to be initialized For slot cards it is not necessary to remove the card for ch.
A Firmware update can now be done via Drag & Drop in the browser. It is not longer necessary to u
with activated FTP services. A user-initiated reboot is also not necessary.
If there occur problems with the firmware, an update can be performed without a login. Enter the IP
followed by /update. After successful admin authentication you may update the firmware and also pe
will the configured IP address. not set back
The default password for is Use this account for first setup.admin cs141-snmp.
The default password for is engineer engineer.
The default password for is guest guest.
Default Auto-Logout is enabled (15 min). After this time spawn of inactivity the user will be logged ou
these settings go to Setup -> System -> Settings.
The power consumption is less compared to the predecessor despite being 10 times faster.


Produktspezifikationen

Marke: AEG
Kategorie: Nicht kategorisiert
Modell: SNMP

Brauchst du Hilfe?

Wenn Sie Hilfe mit AEG SNMP benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Nicht kategorisiert AEG

Bedienungsanleitung Nicht kategorisiert

Neueste Bedienungsanleitung für -Kategorien-