Adaptec 8805E Bedienungsanleitung
Lesen Sie kostenlos die š deutsche Bedienungsanleitung fĆ¼r Adaptec 8805E (2 Seiten) in der Kategorie Regeln. Dieser Bedienungsanleitung war fĆ¼r 15 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet
Seite 1/2
Microsemi AdaptecĀ® Series 8E Family: 8405E, 8805E
Entry-level 12 Gbps PCIe Gen3 SAS/SATA RAID Adapters
Beneļ¬ts
ā¢ Ideal for entry-level 12 Gbps servers and
workstations for redundant boot support and
I/O intensive applications such as databases or
video editing
ā¢ True hardware RAID 0, 1, 10 (also supports
Hybrid RAID)
ā¢ Performance acceleration through 512 MB
DDR3 (1600 MHz) cache
Highlights
ā¢ 4- and 8-port low-proļ¬le MD2 with support for
a maximum of 4 and 8 devices respectively
ā¢ Mixed mode RAID adapter and caching HBA
functionality
ā¢ 12 Gbps and 6 Gbps compatibility with SAS/
SATA HDD or SSD devices
ā¢ 12 Gbps throughput per SAS port using
mini-SAS HD connectors
ā¢ Microsemi's 12 Gbps RAID-on-Chip (ROC),
8-lane PCIe Gen3 interface with 12 Gbps
SAS ports to enable a new generation of
performance
ā¢ 512 MB DDR3 (1600 MHz) cache
ā¢ Up to 500K IOPS
Data center, IT, and general consumer server environments have a broad
range of requirementsāfrom basic connectivity to extreme data storage
capacities. The Series 8E 12 Gbps PCIe Gen3 SAS/SATA RAID adapters
deliver the robustness of hardware RAID in an entry-level solution. They offer
signiļ¬cant performance acceleration over other 6Gbps adapter card solutions
through basic RAID 0,1,10 and built-in cache for cost-effective platforms that
donāt require the full performance and capabilities of our standard Series 8
RAID adapters. The 8805E, with eight internal SAS/SATA ports, is ideal for
applications that require more bandwidth. Both models ļ¬t the requirements of
industrial PC workstations or entry-level servers. The 8405E and the 8805E
support a maximum of four and eight devices respectively, as neither support
the use of expanders.
Maximum Performance for Entry-Level RAID Adapters
Series 8E RAID adapters can also be coupled with 12 Gbps SSDs, providing
maximum read/write bandwidth and IOPS for the most performance-hungry
applications. The 512 MB DDR3 (1600 MHz) built-in cache (recommended
for read and write-through caching) provides maximum acceleration.
Advanced Data Protection and Ease of Use
Microsemi's Adaptec RAID Code (ARC) delivers maximum reliability with an
industry-leading feature set, including all of the RAID levels the industry has
come to expect, plus unique features like ļ¬exible conļ¬guration modes for the
adapter, Hybrid RAID, and optimized disk utilization (ODU) where no available
space is wasted. Microsemi's Adaptec maxView provides an HTML5 web
interface that can be used in standard desktops and mobile browsers for all
storage conļ¬guration and management needs.
Microsemi Corporation (Nasdaq: MSCC) offers a comprehensive portfolio of semiconductor and system solutions for aerospace
& defense, communications, data center and industrial markets. Products include high-performance and radiation-hardened
analog mixed-signal integrated circuits, FPGAs, SoCs and ASICs; power management products; timing and synchronization
devices and precise time solutions, setting the worldās standard for time; voice processing devices; RF solutions; discrete
components; enterprise storage and communication solutions, security technologies and scalable anti-tamper products;
Ethernet solutions; Power-over-Ethernet ICs and midspans; as well as custom design capabilities and services. Microsemi is
headquartered in Aliso Viejo, California and has approximately 4,800 employees globally. Learn more at www.microsemi.com.
Microsemi Corporate Headquarters
One Enterprise, Aliso Viejo, CA 92656 USA
Within the USA: +1 (800) 713-4113
Outside the USA: +1 (949) 380-6100
Fax: +1 (949) 215-4996
Email: sales.support@microsemi.com
www.microsemi.com
Ā©
2016 Microsemi Corporation. All rights reserved.
Microsemi and the Microsemi logo are registered
trademarks of Microsemi Corporation. All other
trademarks and service marks are the property
of their respective owners.
Microsemi makes no warranty, representation, or guarantee regarding the information contained herein or the suitability of its products and services for any
particular purpose, nor does Microsemi assume any liability whatsoever arising out of the application or use of any product or circuit. The products sold
hereunder and any other products sold by Microsemi have been subject to limited testing and should not be used in conjunction with mission-critical equipment
or applications. Any performance speciļ¬cations are believed to be reliable but are not veriļ¬ed, and Buyer must conduct and complete all performance and other
testing of the products, alone and together with, or installed in, any end-products. Buyer shall not rely on any data and performance speciļ¬cations or parameters
provided by Microsemi. It is the Buyerās responsibility to independently determine suitability of any products and to test and verify the same. The information
provided by Microsemi hereunder is provided āas is, where isā and with all faults, and the entire risk associated with such information is entirely with the Buyer.
Microsemi does not grant, explicitly or implicitly, to any party any patent rights, licenses, or any other IP rights, whether with regard to such information itself
or anything described by such information. Information provided in this document is proprietary to Microsemi, and Microsemi reserves the right to make any
changes to the information in this document or to any products and services at any time without notice.
ESC-2161721. 1.0. 9/16
Microsemi AdaptecĀ® Series 8E Family: 8405E, 8805E
Entry-level 12 Gbps PCIe Gen3 SAS/SATA RAID Adapters
Key software
features
ā¢ Flexible conļ¬guration: HBA mode and
auto volume mode for automatic
deployment
ā¢ Optimized disk utilization (multiple arrays
per disk)
ā¢ Support for native 4K sector SAS and
SATA devices in addition to 512-byte
sector devices
ā¢ Hybrid RAID 1 and 10
ā¢ Quick initialization
ā¢ Online capacity expansion
ā¢ Copyback hot spare
ā¢ Dynamic caching algorithm
ā¢ Native command queuing (NCQ)
ā¢ Background initialization
ā¢ Hot-plug drive support
ā¢ RAID level migration
ā¢ Hot sparesāglobal, dedicated, and
pooled
ā¢ Automatic/manual rebuild of hot
spares
ā¢ SES and SAF-TE enclosure
management
ā¢ Conļ¬gurable stripe size
ā¢ S.M.A.R.T. support
ā¢ Multiple arrays per disk drive
ā¢ Dynamic sector repair
ā¢ Staggered drive spin-up
ā¢ Bootable array support
ā¢ Support for tape devices and autoloaders
ā¢ MSI-X support for all device drivers for all
supported operating systems
ā¢ Secure boot support for the uEFI host BIOS
ā¢ USB image available on
start.microsemi.com to boot maxView GUI from
any USB device for enhanced GUI-based setup
and ofļ¬ine maintenance
Management
utilities
maxView Storage Manager
ā¢ Web-based GUI management utility
ā¢ OS support: Windows, Linux, Solaris,
VMware
ā¢ Remote conļ¬guration, monitoring, and
notiļ¬cation
ā¢ Remote ļ¬rmware updates
ā¢ SMI-S support (CIM provider)
ā¢ SMTP
ARCCONF
ā¢ Command-line interface
ā¢ SMI-S support for VMware
BIOS Conļ¬guration Utility (CTRL+A)
ā¢ Legacy conļ¬guration utility
ā¢ Flashable BIOS support
uEFI BIOS Conļ¬guration Utility
ā¢ HII-based conļ¬guration utility
ā¢ Flashable BIOS support
Event Monitor
ā¢ Lightweight event monitoring and logging tool
ā¢ Distributes adapter events and notiļ¬es user
ā¢ VMWare vSphere plugin
Operating
systems
Microsoft Windows, Red Hat Linux, SUSE Linux, Fedora, Debian Linux, Ubuntu Linux, Sun Solaris, FreeBSD, VMware ESXi.
The latest drivers are available at start.microsemi.com.
Dimensions 2.535" H Ć 6.6" L (64 mm Ć 167 mm)
Operating
temperature
0 Ā°C to 55 Ā°C (with 200 LFM airļ¬ow).
Note: This adapter contains a powerful RAID processor that requires adequate airļ¬ow to operate reliably. Only install this card into server or PC
chassis with
at least 200 LFM airļ¬ow. Temperature measured 1 inch from RAID adapter.
Operating
current 0.1 A at 3.3 VDC, 1.2 A at 12.0 VDC (8405E, 8805E)
Regulatory
certiļ¬cation CE, FCC, UL, C-tick, VCCI, KCC, CNS
Environmental
compliance RoHS
MTBF 2 million hours at 40 Ā°C
Warranty 3 years
RAID adapter 8405E 8805E
Order number 2293901-R 2294001-R
RAID levels 0,1,10 0,1,10
Ports 4 internal 8 internal
Connectors 1 SFF-8643 2 SFF-8643
Bus interface 8-lane PCIe Gen3 8-lane PCIe Gen3
Processor 12 Gbps RoC 12 Gbps RoC
Cache 512 MB DDR3 (1600 MHz) 512 MB DDR3 (1600 MHz)
Cache protection No No
Number of supported
devices 4 8
Produktspezifikationen
Marke: | Adaptec |
Kategorie: | Regeln |
Modell: | 8805E |
Breite: | 167 mm |
Hƶhe: | 64 mm |
Betriebstemperatur: | 0 - 55 Ā°C |
Zertifizierung: | CE, FCC, UL, C-tick, VCCI, KCC, CNS, RoHS |
Warentarifnummer (HS): | 84733080 |
UnterstĆ¼tzt Windows-Betriebssysteme: | Ja |
UnterstĆ¼tzung anderer Betriebsysteme: | FreeBSD, Solaris 10, Solaris 11, Solaris 8, Solaris 9 |
Mittlere Betriebsdauer zwischen AusfƤllen (MTBF): | 2000000 h |
SpeicherkapazitƤt: | 512 MB |
RAID Level: | 0, 1,10 |
Interner Speichertyp: | DDR3 |
UnterstĆ¼tzte Speicherlaufwerk-Schnittstellen: | SAS, Serial ATA |
UnterstĆ¼tzte Linux-Betriebssysteme: | Ja |
Hostschnittstelle: | PCI Express x8 |
PCI-Express-Slots-Version: | 3.0 |
Speichertaktfrequenz: | 1600 MHz |
DatenĆ¼bertragungsrate: | 12 Gbit/s |
S.M.A.R.T. UnterstĆ¼tzung: | Ja |
Anzahl der unterstĆ¼tzten GerƤte: | 8 |
SSD-UnterstĆ¼tzung: | Ja |
Interne mini-SAS-AnschlĆ¼sse: | 2 |
RAID-Level-Migration: | Ja |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Adaptec 8805E benƶtigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Regeln Adaptec
25 Januar 2024
Bedienungsanleitung Regeln
- Regeln Da-Lite
- Regeln Gembird
- Regeln Hama
- Regeln HyperX
- Regeln Logitech
- Regeln Manhattan
- Regeln Manta
- Regeln Microsoft
- Regeln Nacon
- Regeln Philips
- Regeln Saitek
- Regeln Sony
- Regeln Speedlink
- Regeln SteelSeries
- Regeln Trust
- Regeln Panasonic
- Regeln Roland
- Regeln Bosch
- Regeln Canon
- Regeln Velleman
- Regeln Hori
- Regeln Kƶnig
- Regeln Renkforce
- Regeln Thomson
- Regeln Pyle
- Regeln Mitsubishi
- Regeln Thermador
- Regeln Denon
- Regeln One For All
- Regeln BeamZ
- Regeln Akai
- Regeln Garmin
- Regeln Perel
- Regeln Aruba
- Regeln Astro
- Regeln Bigben
- Regeln Plantronics
- Regeln Thrustmaster
- Regeln Turtle Beach
- Regeln TOA
- Regeln Razer
- Regeln Scosche
- Regeln Tangent
- Regeln Honeywell
- Regeln SBS
- Regeln DJI
- Regeln Reely
- Regeln Supermicro
- Regeln Genesis
- Regeln SilverStone
- Regeln Mackie
- Regeln Numark
- Regeln ESI
- Regeln Eurolite
- Regeln Showtec
- Regeln Monoprice
- Regeln Monacor
- Regeln Ednet
- Regeln Konftel
- Regeln Sherwood
- Regeln Lumens
- Regeln Korg
- Regeln ION
- Regeln Amazon
- Regeln IVT
- Regeln DataVideo
- Regeln Manfrotto
- Regeln Tracer
- Regeln Cisco
- Regeln Danfoss
- Regeln American Audio
- Regeln Cameo
- Regeln Kramer
- Regeln Irritrol
- Regeln Carel
- Regeln Vaddio
- Regeln RCA
- Regeln HQ Power
- Regeln Nintendo
- Regeln Speed-Link
- Regeln Bogen
- Regeln Sonance
- Regeln Rain Bird
- Regeln Sven
- Regeln Fostex
- Regeln PDP
- Regeln Homematic IP
- Regeln Blackmagic Design
- Regeln Ikan
- Regeln Gamesir
- Regeln Ganz
- Regeln Infinity
- Regeln Logic3
- Regeln Novation
- Regeln Spektrum
- Regeln Steca
- Regeln AMX
- Regeln Universal Remote Control
- Regeln Movistar
- Regeln Big Ben
- Regeln Intel
- Regeln Snakebyte
- Regeln RGBlink
- Regeln StarTech.com
- Regeln APart
- Regeln Sonnet
- Regeln Niles
- Regeln Russound
- Regeln Inovonics
- Regeln Atlas Sound
- Regeln HID Identity
- Regeln ATen
- Regeln Morningstar
- Regeln Chauvet
- Regeln Xtreme
- Regeln Phoenix Contact
- Regeln OSD Audio
- Regeln Indiana Line
- Regeln DreamGEAR
- Regeln Crestron
- Regeln PowerA
- Regeln Atlona
- Regeln LYYT
- Regeln Xantech
- Regeln Sonifex
- Regeln Leviton
- Regeln 8BitDo
- Regeln Highpoint
- Regeln Key Digital
- Regeln Nyko
- Regeln AViPAS
- Regeln Aquatic AV
- Regeln Auray
- Regeln Areca
- Regeln Trenton Systems
- Regeln Contour Design
- Regeln Ledxon
- Regeln Kanex
- Regeln LumenRadio
- Regeln Datapath
- Regeln Circle
- Regeln Rachio
- Regeln Victrix
Neueste Bedienungsanleitung fĆ¼r -Kategorien-
10 August 2024
23 Juni 2024
22 Juni 2024
21 Juni 2024
21 Juni 2024
21 Juni 2024
21 Juni 2024
21 Juni 2024
21 Juni 2024
21 Juni 2024