Viking G8MD Bedienungsanleitung
Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Viking G8MD (24 Seiten) in der Kategorie Afzuigkap. Dieser Bedienungsanleitung war für 19 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet
Seite 1/24
MODELS G6MD • G8MD • G10MD
Page 1
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Installation work and electrical wiring must be done by a qualified
person(s) in accordance with all applicable codes and standards,
including fire-rated construction codes and standards.
2. Validated performance testing certified for use with BEST,
Broan, and Broan Elite range hoods.
3. This unit is not designed to provide combustion air for fuel-
burning appliances.
4. Do not connect the unit directly to a combustion appliance of
any type.
5. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment
manufacturer’s guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and
Air Conditioning Engineers (ASHRAE), and the local code
authorities.
6. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
7. When performing installation, servicing or cleaning the unit, it is
recommended to wear safety glasses and gloves.
8. During extreme weather events including snow storms, ensure
that the intake area for the outside air duct is not blocked and
able to provide a clear pathway for outside air to enter the
system.
9. When cutting or drilling into wall or ceiling, do not damage
electrical wiring or other hidden utilities.
10. When notching or drilling into framing including floor supports,
rim joists, and wall studs, comply with code and manufacturer
limitations on allowable modifications to these structural
members.
11. This unit is intended to be installed within the home in a location
protected from moisture.
12. This unit must be in an accessible location which allows for
inspection of the unit.
13. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in this document.
14. When federal, provincial or state legislation comprises more
restrictive installation and/or certification requirements, the
aforementioned requirements prevail on those of this document
and the installer agrees to conform to these at his own expense.
AUTOMATIC MAKE-UP AIR
DAMPER WITH TRANSFORMER
& PRESSURE SWITCH
READ AND SAVE THESE INSTRUCTIONS
FOR RESIDENTIAL USE ONLY
CAUTION
1. Do not locate outside air inlet near hazardous materials or explosives.
2. Unit shall not be installed to introduce air from crawlspaces, garages,
attics, adjacent dwelling units, or other locations within the building
shell. Unit shall be installed to introduce air directly from outdoors.
3. Do not run the outside air duct directly above or closer than 2 ft to
any furnace or its supply plenum, boiler, or other heat producing
appliance.
4. Any ductwork used in conjunction with the Damper must be installed
in compliance with all local and national codes that are applicable.
5. Do not operate the Damper for fresh air introduction until all system
filters, including the central duct system filter, have been installed per
the system design.
6. Please read the unit specification label on the product for further
information and requirements.
7. The Damper’s outdoor air intake, ducting, and any filters should be
inspected and maintained on a regular basis.
8. Insulate the duct and damper to prevent build-up of condensation in
cold weather climates. Vapor barriers on both sides of insulation are
recommended.
MODELS G6MD • G8MD • G10MD
Page 2
OUTSIDE AIR INTAKE LOCATION
Proper design and location of the outside air intake location is critical in
ensuring that the Damper can safely and reliably provide an opening for
fresh air to enter the home. The following requirements for the location
of the outside air intake must be met:
• -
pliance vents, chimneys, plumbing stacks, and bathroom or kitchen
exhaust vents. If local codes have more stringent separation re-
quirements, they shall apply.
•
blockage from snow or other debris such as leaves, and at a mini-
mum of 1’ above grade.
• -
rages, attics, adjacent dwelling units, or any enclosed part of the
building. The Damper should be installed to draw air directly from
outdoors.
OUTSIDE AIR INTAKE OPENING PROTECTION
Because the Damper, together with the end cap and outside air duct
which are installed with it, will allow outdoor air into the indoor environ-
ment, it is important to meet the following requirements:
•
animals and outside debris. Clean screens often and do not remove.
•
must cover the entire opening of the outside air duct. This screen
must also have openings of at least ¼” but no larger than ½”.
•
for the protection of openings in exterior walls, including steps to
prevent moisture intrusion around the opening.
Note that the screen over the outside air opening is not a filter. It is
intended to prevent the intake of leaves, animals, or debris into the out-
side air duct. A downstream filter is necessary to remove pollen, dust,
and other airborne particles. Potential filter locations are shown below
in the Typical Installations section.
MINIMUM RETURN AIR TEMPERATURE REQUIREMENTS
HVAC equipment manufacturers may have minimum requirements for
the air temperature in the return air plenum. Introducing outdoor air to
the return side of the central duct system may impact this temperature.
The installer should adjust both the size of the outside air duct and the
location of its connection to the return side of the central duct system in
a manner so that minimum air temperature requirements are satisfied
under design conditions.
PLAN THE INSTALLATION
Planning the installation first requires selecting the most appropriate
installation approach. The chart below offers suggestions for the most
effective installation approach by considering a few important factors.
Further details on the two main types of installations are provided below.
Yes
•House has central duct work?
Yes
•Return-air side of duct work is
accessible -either the return-air trunk
or return-air plenum?
Damper connected to
return side of central
duct system
No
No
Damper ducted directly
to a ceiling, floor, or wall
register
WHAT IS INCLUDED IN THE
PACKAGE
- Transformer
- Pressure Switch Kit which includes:
- Pressure Switch
- Probe
- 12” PVC tubing 1/4” I.D.
- Gasket
TOOLS REQUIRED
- 1/4” Socket Drive
- Flathead or Phillips Screw Driver
- 3/8” Drill Bit
- Duct Tape
- Low Voltage Wire (2 Conductor)
- (2) 1/4” Female Spade Terminals
- Wire Nuts
MODELS G6MD • G8MD • G10MD
Page 3
Damper and outside air duct connected directly to a ceiling, floor, or wall register.
INTERIOR WALL
WALL
REGISTER
REGISTER BOX ADAPTED
WITH SLIDE-IN FILTER (optional)
MOTORIZED DAMPER
FIELD MEASUREMENT OF OUTSIDE
AIR DUCT PRESSURE. (See “Install The
Damper” section on page 3 for damper
balancing instructions.)
WALL CAP WITH
BIRD SCREEN
INSULATED OUTSIDE
AIR DUCT (slope toward wall cap)
EXTERIOR WALL
VENTILATION AIR INTAKE
(locate away from pollutant sources)
TYPICAL INSTALLATIONS
Installations will vary according to the location in the home where the unit is installed and which model Damper is used. Use the following
illustrations and notes as guidance for your own installation. Always comply with local code requirements and in any instance where a detail
shown below conflicts with local code, the local code provision shall apply.
Damper connected to return side of central duct system.
AIR HANDLER UNIT
COOLING APPARATUS
AIR DISTRIBUTION FAN
HEATING APPARATUS
THERMOSTAT
CENTRAL SYSTEM SUPPLY AIR
REGISTER BOX ADAPTED
WITH SLIDE-IN FILTER (optional)
AUTO. MAKE-UP AIR DAMPER
FIELD MEASUREMENT OF OUTSIDE
AIR DUCT PRESSURE. (See “Install The
Damper” section on page 3 for damper
balancing instructions.)
FRESH AIR INLET WALL CAP
WITH BIRD SCREEN
INSULATED OUTSIDE
AIR DUCT (slope toward wall cap)
EXTERIOR WALL
VENTILATION AIR INTAKE
(locate away from pollutant sources)
CENTRAL SYSTEM RETURN AIR
FURNACE FILTER
Produktspezifikationen
Marke: | Viking |
Kategorie: | Afzuigkap |
Modell: | G8MD |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Viking G8MD benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Afzuigkap Viking
9 September 2024
25 August 2024
9 August 2024
5 August 2024
5 August 2024
3 August 2024
1 August 2024
31 Juli 2024
30 Juli 2024
30 Juli 2024
Bedienungsanleitung Afzuigkap
- Afzuigkap Samsung
- Afzuigkap Infiniton
- Afzuigkap Adelberg
- Afzuigkap Hanseatic
- Afzuigkap Panasonic
- Afzuigkap LG
- Afzuigkap Bestron
- Afzuigkap Guzzanti
- Afzuigkap MX Onda
- Afzuigkap Bosch
- Afzuigkap AEG
- Afzuigkap Asko
- Afzuigkap Siemens
- Afzuigkap ATAG
- Afzuigkap Bauknecht
- Afzuigkap Concept
- Afzuigkap Electrolux
- Afzuigkap Fagor
- Afzuigkap Gaggenau
- Afzuigkap Gorenje
- Afzuigkap Klarstein
- Afzuigkap Küppersbusch
- Afzuigkap Miele
- Afzuigkap Teka
- Afzuigkap Whirlpool
- Afzuigkap Bomann
- Afzuigkap Russell Hobbs
- Afzuigkap Vox
- Afzuigkap IKEA
- Afzuigkap ECG
- Afzuigkap Amica
- Afzuigkap BEKO
- Afzuigkap Blaupunkt
- Afzuigkap Boretti
- Afzuigkap Grundig
- Afzuigkap Heinner
- Afzuigkap Hotpoint
- Afzuigkap Inventum
- Afzuigkap KitchenAid
- Afzuigkap Schneider
- Afzuigkap Sharp
- Afzuigkap Smeg
- Afzuigkap AEG-Electrolux
- Afzuigkap Ardo
- Afzuigkap Ariston
- Afzuigkap Aspes
- Afzuigkap Balay
- Afzuigkap Blomberg
- Afzuigkap Scandomestic
- Afzuigkap Brandt
- Afzuigkap Candy
- Afzuigkap Constructa
- Afzuigkap Corberó
- Afzuigkap Edesa
- Afzuigkap ELIN
- Afzuigkap Eudora
- Afzuigkap Eurotech
- Afzuigkap Exquisit
- Afzuigkap GE
- Afzuigkap Haier
- Afzuigkap High One
- Afzuigkap Hisense
- Afzuigkap Hoover
- Afzuigkap Hotpoint-Ariston
- Afzuigkap Ignis
- Afzuigkap Bartscher
- Afzuigkap Indesit
- Afzuigkap Juno
- Afzuigkap Baumatic
- Afzuigkap Kelvinator
- Afzuigkap Bertazzoni
- Afzuigkap Maytag
- Afzuigkap Midea
- Afzuigkap Caple
- Afzuigkap Neff
- Afzuigkap Nordmende
- Afzuigkap PKM
- Afzuigkap Privileg
- Afzuigkap Progress
- Afzuigkap Rex
- Afzuigkap Rommer
- Afzuigkap ETNA
- Afzuigkap Scholtès
- Afzuigkap Frigidaire
- Afzuigkap SIBIR
- Afzuigkap Svan
- Afzuigkap Thor
- Afzuigkap V-ZUG
- Afzuigkap Junker
- Afzuigkap Zanker
- Afzuigkap Zanussi
- Afzuigkap KKT Kolbe
- Afzuigkap M-System
- Afzuigkap Monogram
- Afzuigkap Oranier
- Afzuigkap Pelgrim
- Afzuigkap Philco
- Afzuigkap Respekta
- Afzuigkap Rosières
- Afzuigkap Thermador
- Afzuigkap Viva
- Afzuigkap Arçelik
- Afzuigkap Continental Edison
- Afzuigkap Kernau
- Afzuigkap Tesla
- Afzuigkap Imperial
- Afzuigkap Elica
- Afzuigkap DeLonghi
- Afzuigkap Eico
- Afzuigkap Franke
- Afzuigkap Wolkenstein
- Afzuigkap Frilec
- Afzuigkap Honeywell
- Afzuigkap Foster
- Afzuigkap Weller
- Afzuigkap Silverline
- Afzuigkap Novy
- Afzuigkap Airforce
- Afzuigkap Airlux
- Afzuigkap Broan
- Afzuigkap Cata
- Afzuigkap Cylinda
- Afzuigkap De Dietrich
- Afzuigkap Dominox
- Afzuigkap Elba
- Afzuigkap Falcon
- Afzuigkap Falmec
- Afzuigkap Faure
- Afzuigkap Hansa
- Afzuigkap Leisure
- Afzuigkap MPM
- Afzuigkap Nodor
- Afzuigkap Roblin
- Afzuigkap Sauter
- Afzuigkap Stoves
- Afzuigkap Thermex
- Afzuigkap UPO
- Afzuigkap Bielmeier
- Afzuigkap Logik
- Afzuigkap Dacor
- Afzuigkap Orima
- Afzuigkap Proline
- Afzuigkap Dimplex
- Afzuigkap Faber
- Afzuigkap Mora
- Afzuigkap Toolcraft
- Afzuigkap Westinghouse
- Afzuigkap Wolf
- Afzuigkap Amana
- Afzuigkap Arthur Martin-Electrolux
- Afzuigkap Euromaid
- Afzuigkap Gram
- Afzuigkap Tesy
- Afzuigkap Vivax
- Afzuigkap Omega
- Afzuigkap Profilo
- Afzuigkap Sauber
- Afzuigkap Zelmer
- Afzuigkap Kleenmaid
- Afzuigkap Lamona
- Afzuigkap Limit
- Afzuigkap Meireles
- Afzuigkap Acec
- Afzuigkap Ariston Thermo
- Afzuigkap Gutmann
- Afzuigkap Signature
- Afzuigkap Bellini
- Afzuigkap Best
- Afzuigkap Soler & Palau
- Afzuigkap AYA
- Afzuigkap Fisher & Paykel
- Afzuigkap Esatto
- Afzuigkap Orbegozo
- Afzuigkap Napoleon
- Afzuigkap Ilve
- Afzuigkap Furrion
- Afzuigkap Unox
- Afzuigkap CDA
- Afzuigkap Saturn
- Afzuigkap Berg
- Afzuigkap Defy
- Afzuigkap Itho
- Afzuigkap Jocel
- Afzuigkap Kenmore
- Afzuigkap La Germania
- Afzuigkap Marynen
- Afzuigkap Mepamsa
- Afzuigkap Piccante
- Afzuigkap Rangemaster
- Afzuigkap Scancool
- Afzuigkap Sirius
- Afzuigkap Steelmatic
- Afzuigkap Technika
- Afzuigkap Tecnolux
- Afzuigkap BLANCO
- Afzuigkap Turbo Air
- Afzuigkap Zephyr
- Afzuigkap Whispair
- Afzuigkap Kunft
- Afzuigkap Kucht
- Afzuigkap Schweigen
- Afzuigkap Becken
- Afzuigkap Wells
- Afzuigkap JennAir
- Afzuigkap BlueStar
- Afzuigkap Fulgor Milano
- Afzuigkap Air King
- Afzuigkap Flama
- Afzuigkap Halifax
- Afzuigkap ZLine
- Afzuigkap K&H
- Afzuigkap Arctic Cooling
- Afzuigkap Barazza
- Afzuigkap Qasair
- Afzuigkap Artusi
- Afzuigkap Glem Gas
- Afzuigkap Sôlt
- Afzuigkap Chef
- Afzuigkap Sam Cook
- Afzuigkap LERAN
- Afzuigkap Belling
- Afzuigkap Cookology
- Afzuigkap Summit
- Afzuigkap Linarie
- Afzuigkap Everdure
- Afzuigkap Euro Appliances
- Afzuigkap NuTone
- Afzuigkap Robinhood
- Afzuigkap XO
- Afzuigkap Venmar
- Afzuigkap Café
- Afzuigkap Porter & Charles
- Afzuigkap Jenn-Air
- Afzuigkap New World
- Afzuigkap Belion
- Afzuigkap Tisira
- Afzuigkap Ciarra
- Afzuigkap CENDO
- Afzuigkap Twin Eagles
- Afzuigkap Airone
- Afzuigkap Kluge
- Afzuigkap Trade-Wind
- Afzuigkap Mayer
- Afzuigkap Vent-A-Hood
- Afzuigkap HomeCraft
- Afzuigkap CEEM
Neueste Bedienungsanleitung für -Kategorien-
16 September 2024
16 September 2024
16 September 2024
16 September 2024
16 September 2024
16 September 2024
16 September 2024
16 September 2024
16 September 2024
16 September 2024