ADJUSTABLE THERMOSTAT – IMMERSION – WITH SHANK
Read all the instructions carefully
TIMM – R100 and TIMM – R200 are boxed unipolar thermostats, liquid expansion, with switching
contacts, complete with core hitch. Ideal for automatic regulation on boilers, pumps and other heating
equipment.
The thermostats are fixed using a ½” threaded trap.
SAFETY WARNINGS
CHECK THAT THE POWER IS DISCONNECTED on the USER BEING CONTROLLED before connecting the
thermostat. Check that the power input is compatible with the output on the contacts (see the
technical data).
Code Model Description
VE305900 TIMM – R100 Adjustable thermostat 30/90°C L100mm
VE306700 TIMM – R200 Adjustable thermostat 30/90°C L200mm
Dimensions
43 L1
L2 12 8
21
60
115
18,5 96,5
ø8
1/2”Gc.
TIMM-R100
L1 = 105
L2 = 85
TIMM-R200
L1 = 205
L2 = 185
30
40
60
70
80
50
90
0
TECHNICAL DATA
• Setting range: +30 ÷ +90°C (±3°C)
• Differential: 4°C ±2°C
• Degree of protection: IP 40
• Insulation class: II
• Thermal gradient <1°C/min
• Maximum head temperature: 80°C
• Maximum bulb temperature: 110°C
• Maximum sheath pressure: 10 bar
• Change-over contacts
• Contact outputs: 16 A (5) 250 Vca
• Action type: 1B
• Core hitch: M20
INSTALLATION
• ATTENTION: only specialised electricians or authorised installers must carry out the instructions given
in this leaflet, in full observance of the safety instructions and current applicable legislation.
CONNECTIONS
A. Loosen the screw to remove the trap from the instrument.
B. Fix the trap in the correct housing (½” threading).
C. Replace the bulb on the thermostat inside the trap and tighten down the fixing screw.
D. Slide off the knob and unscrew the two screws beneath to open the thermostat cover.
E. Pass the leads through the core hitch and make the connections following the diagram below.
F. Replace the cover, screws and knob.
REFERENCE STANDARDS
Conformity to the EU directive 2014/35/UE (LVD) and 2014/30/UE (EMCD)
is declared in reference to the harmonised standards: EN 60730-1, EN 60730-2-9
User Manual
ADJUSTABLE THERMOSTAT – WITH EXTERNAL CAPILLARY
Read all the instructions carefully
TIMM – R cap is a boxed unipolar thermostat, liquid expansion, with switching contacts, complete with core
hitch. Ideal for automatic regulation on boilers, pumps and other heating equipment.
The thermostat can be fixed on any surface using the perforated fins.
SAFETY WARNINGS
CHECK THAT THE POWER IS DISCONNECTED on the USER BEING CONTROLLED before connecting the
thermostat. Check that the power input is compatible with the output on the contacts (see the technical
data)
Code Model Description
VE307500 TIMM - R cap Adjustable thermostat 30/90°C with extern capillary L1000mm
Dimensions
ø6 21
60
43
50
115
96,518,5
3,8
30
40
60
70
80
50
90
0
TECHNICAL DATA
• Setting range: +30 ÷ +90°C (±3°C)
• Differential: 4°C ±2°C
• Degree of protection: IP 40
• Insulation class: II
• Thermal gradient: <1°C/min
• Maximum head temperature: 80°C
• Maximum bulb temperature: 110°C
• Change-over contacts
• Contact outputs: 16 A (5) 250 Vca
• Action type: 1B
• Core hitch: M20
INSTALLATION
• ATTENTION: only specialised electricians or authorised installers must carry out the instructions given in
this leaflet, in full observance of the safety instructions and current applicable legislation.
CONNECTIONS
A. Fix on any surface using the perforated fins.
B. Immerse the bulb at the end of the capillary in the liquid (or place it closely touching the surface) that the
temperature has to be regulated for.
C. Slide off the knob and unscrew the two screws beneath to open the thermostat cover.
D. Pass the leads through the core hitch and make the connections following the diagram below.
E. Replace the cover, screws and knob.
REFERENCE STANDARDS
Conformity to the EU directive 2014/35/UE (LVD) and 2014/30/UE (EMCD)
is declared in reference to the harmonised standards: EN 60730-1, EN 60730-2-9
User Manual
RESETTABLE THERMOSTAT – IMMERSION – WITH SHANK
Read all the instructions carefully
TIMM – B is a boxed unipolar thermostat, liquid expansion, complete with core hitch. Temperature safety
control with manual reset and positive securety.
The thermostat is fixed using a ½” threaded trap.
SAFETY WARNINGS
CHECK THAT THE POWER IS DISCONNECTED on the USER BEING CONTROLLED before connecting the
thermostat. Check that the power input is compatible with the output on the contacts (see the technical
data).
Code Model Description
VE308300 TIMM – B Resettable thermostat L100mm
Dimensions
105
85 12 8
21
6243
115
18,5 96,5
ø8
1/2”Gc.
TECHNICAL DATA
• Limiter pre-set temperature: 99°C (± 4°)
• Reset manual and positive safety
• Degree of protection: IP 40
• Insulation class: II
• Thermal gradient: <1°C/min
• Maximum head temperature: 80°C
• Maximum bulb temperature: 110°C
• Maximum sheath pressure: 10 bar
• Normally closed contact
• Contact outputs: 16 A (5) 250 Vca
• Action type: 1B
• Core hitch: M20
INSTALLATION
• ATTENTION: only specialised electricians or authorised installers must carry out the instructions given in
this leaflet, in full observance of the safety instructions and current applicable legislation.
CONNECTIONS
A. Loosen the screw to remove the trap from the instrument.
B. Fix the trap in the correct housing (½” threading).
C. Replace the bulb on the thermostat inside the trap and tighten down the fixing screw.
D. Unscrew the protection hood of the resettable push-button and the below dice to open the thermostat
cover.
E. Pass the leads through the core hitch and make the connections following the diagram below.
F. Replace the cover, nut and gap.
RESET OPERATION
In case of activation of the reset thermostat (open contact), wait until the system temperature falls within the
normal limits. Remove the causes that led to the overheating of the system. Then proceed to manually reset the
thermostat by removing the plastic cap and pushing the button inside the nut with a special tool. Finally screw
the cap onto the nut.
REFERENCE STANDARDS
Conformity to the EU directive 2014/35/UE (LVD) and 2014/30/UE (EMCD)
is declared in reference to the harmonised standards: EN 60730-1, EN 60730-2-9
User Manual
DOUBLE RESETTABLE AND ADJUSTABLE THERMOSTAT – IMMERSION – WITH SHANK
Read all the instructions carefully
TIMM – RB is a boxed double unipolar thermostat, liquid expansion, with switching contacts, complete
with core hitches. Temperature regulator and safety control with manual reset and positive securety.
The thermostat is fixed using a ½” threaded trap.
SAFETY WARNINGS
CHECK THAT THE POWER IS DISCONNECTED on the USER BEING CONTROLLED before connecting the
thermostat. Check that the power input is compatible with the output on the contacts (see the
technical data).
Code Model Description
VE309100 TIMM – RB Resettable and adjustable thermostat 30/90°C L100mm
Dimensions
86
115
110
90 12 8
62
21
96,5
18,5
ø14
1/2”Gc.
30
40
60
70
80
50
90
0
TECHNICAL DATA
• Regulator temperature setting range: +30 ÷ +90°C (± 3°C)
• Differential
:
4°C ± 2°C
• Limiter pre-set temperature: +99°C (± 4°C)
• Reset: manual and positive safety
• Degree of protection: IP40
• Insulation class: II
• Thermal gradient: <1 °C/min
• Maximum head temperature: 80°C
• Maximum bulb temperature: 110°C
• Maximum sheath pressure: 10 bar
• Normally closed or change-over contacts
• Contact outputs: 16 A (5) 250 Vca
• Action type: 1B
• Core hitch M20
INSTALLATION
• ATTENTION: only specialised electricians or authorised installers must carry out the instructions given
in this leaflet, in full observance of the safety instructions and current applicable legislation.
CONNECTIONS
A. Loosen the screw to remove the trap from the instrument.
B. Fix the trap in the correct housing (½” threading).
C. Replace the bulbs on the double thermostat inside the trap and tighten down the fixing screw.
D. To access to the limiter thermostat remove the cover and nut. To access to the regulator thermostat
remove the knob and below the screws. Then remove the double plastic cover.
E. Pass the leads through the core hitches. The instrument is designed to work on two independent
circuits (one with the regulator and the other with the limiter), or on a single circuit with the regulator
and limiter connected as shown in the following diagram.
F. Replace the cover, screws and knob nut and cap.
RESET OPERATION
In case of activation of the reset thermostat (open contact), wait until the system temperature falls within
the normal limits. Remove the causes that led to the overheating of the system. Then proceed to manually
reset the thermostat by removing the plastic cap and pushing the button inside the nut with a special tool.
Finally screw the cap onto the nut.
REFERENCE STANDARDS
Conformity to the EU directive 2014/35/UE (LVD) and 2014/30/UE (EMCD)
is declared in reference to the harmonised standards: EN 60730-1, EN 60730-2-9
information to users pursuant to art. 14 of the directive 2012/19 / EU of the european parliament and of the council of 4 july 2012 on waste electrical and electronic equipment (WEEE)
If the crossed-out bin symbol appears on the equipment or packaging, this means the product must not be included with other general waste at the end of its working life. The user must take the worn product to a sorted waste center, or return it to the retailer when purchasing a new one.
Products for disposal can be consigned free of charge (without any new purchase obligation) to retailers with a sales area of at least 400 m2, if they measure less than 25 cm. An efficient sorted waste collection for the environmentally friendly disposal of the used device,
or its subsequent recycling, helps avoid the potential negative effects on the environment and people’s health, and encourages the re-use and/or recycling of the construction materials.
Produktspezifikationen
Marke: | Vemer |
Kategorie: | Thermostat |
Modell: | TIMM - R cap |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Vemer TIMM - R cap benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Thermostat Vemer
17 September 2024
29 August 2024
8 August 2024
8 August 2024
7 August 2024
26 Juli 2024
25 Juli 2024
25 Juli 2024
24 Juli 2024
20 Juli 2024
Bedienungsanleitung Thermostat
- Thermostat Basetech
- Thermostat Hama
- Thermostat Nedis
- Thermostat SilverCrest
- Thermostat Panasonic
- Thermostat Brennenstuhl
- Thermostat Cotech
- Thermostat Profile
- Thermostat Bosch
- Thermostat AEG
- Thermostat Siemens
- Thermostat ATAG
- Thermostat Taurus
- Thermostat Velleman
- Thermostat Devolo
- Thermostat Schwaiger
- Thermostat Alecto
- Thermostat Conrad
- Thermostat EMOS
- Thermostat Gira
- Thermostat HomeMatic
- Thermostat Renkforce
- Thermostat Technoline
- Thermostat TFA
- Thermostat Schneider
- Thermostat Corberó
- Thermostat GE
- Thermostat King
- Thermostat Avidsen
- Thermostat Elro
- Thermostat Gigaset
- Thermostat Tesla
- Thermostat Max
- Thermostat Perel
- Thermostat Nexa
- Thermostat Vasco
- Thermostat Fenix
- Thermostat Westfalia
- Thermostat Vaillant
- Thermostat Honeywell
- Thermostat Remko
- Thermostat Junkers
- Thermostat RADEMACHER
- Thermostat AVM
- Thermostat ELV
- Thermostat TP-Link
- Thermostat Zehnder
- Thermostat Lux
- Thermostat De Dietrich
- Thermostat Netatmo
- Thermostat Theben
- Thermostat Tado
- Thermostat Remeha
- Thermostat Saunier Duval
- Thermostat Stiebel Eltron
- Thermostat Truma
- Thermostat Viessmann
- Thermostat Xavax
- Thermostat Hager
- Thermostat Dimplex
- Thermostat Buderus
- Thermostat Noma
- Thermostat JUNG
- Thermostat Boneco
- Thermostat Hunter
- Thermostat Baxi
- Thermostat Wolf
- Thermostat Nest
- Thermostat Magnum
- Thermostat HQ
- Thermostat Itho Daalderop
- Thermostat Carrier
- Thermostat Tylö
- Thermostat Busch-Jaeger
- Thermostat SPC
- Thermostat Gree
- Thermostat Sygonix
- Thermostat Orbis
- Thermostat Econo-heat
- Thermostat EQ-3
- Thermostat RWE
- Thermostat Eberle
- Thermostat BTicino
- Thermostat Bulex
- Thermostat Danfoss
- Thermostat Delta Dore
- Thermostat Fantini Cosmi
- Thermostat Grässlin
- Thermostat Heimeier
- Thermostat IMIT
- Thermostat Klafs
- Thermostat Oventrop
- Thermostat Salus
- Thermostat Seitron
- Thermostat EVE
- Thermostat Ariston Thermo
- Thermostat Elektrobock
- Thermostat Intertechno
- Thermostat Mikoterm
- Thermostat Ferroli
- Thermostat Carel
- Thermostat Daikin
- Thermostat EnerGenie
- Thermostat Oregon Scientific
- Thermostat Finder
- Thermostat Homematic IP
- Thermostat Levoit
- Thermostat EQ3
- Thermostat Google
- Thermostat Somfy
- Thermostat Berker
- Thermostat Elgato
- Thermostat Elco
- Thermostat Devi
- Thermostat Drayton
- Thermostat Drayton Erie
- Thermostat Easy Timer
- Thermostat EasyTemp
- Thermostat Eliwell
- Thermostat Emerson
- Thermostat Emmeti
- Thermostat Enda
- Thermostat Eneco
- Thermostat Eqiva
- Thermostat Essent
- Thermostat Etherma
- Thermostat Eurotronic
- Thermostat Extraflame
- Thermostat Frico
- Thermostat Go Green
- Thermostat Helios (Amfra)
- Thermostat Hornbach
- Thermostat Hugo Muller
- Thermostat ICY
- Thermostat IR-V
- Thermostat Itho
- Thermostat Johnson Control
- Thermostat Landis Gyr
- Thermostat Levica
- Thermostat Lowes
- Thermostat Muller
- Thermostat Nefit
- Thermostat Niko
- Thermostat Nobo
- Thermostat OJ ELECTRONICS
- Thermostat Otio
- Thermostat Plieger
- Thermostat Plugwise
- Thermostat Radson
- Thermostat THERMAFLEX
- Thermostat Thermy
- Thermostat ACV
- Thermostat Hive
- Thermostat ThermoSmart
- Thermostat UPM
- Thermostat VDH
- Thermostat Wachendorff
- Thermostat Watts
- Thermostat Webasto
- Thermostat Weishaupt
- Thermostat Worcester-Bosch
- Thermostat Yokis
- Thermostat Z-Wave
- Thermostat Vimar
- Thermostat TrickleStar
- Thermostat Horstmann
- Thermostat Computherm
- Thermostat Heatit
- Thermostat POER
- Thermostat H-Tronic
- Thermostat PECO
- Thermostat Chacon
- Thermostat Emko
- Thermostat Fibaro
- Thermostat Heatmiser
- Thermostat Crestron
- Thermostat ORNO
- Thermostat Optima
- Thermostat HomePilot
- Thermostat Krone
- Thermostat ChiliTec
- Thermostat Arnold Rak
- Thermostat Ouellet
- Thermostat Jumo
- Thermostat Wallair
- Thermostat Maico
- Thermostat Ecobee
- Thermostat Tellur
- Thermostat STI
- Thermostat Cepra
- Thermostat Tru Components
- Thermostat Qubino
- Thermostat Gewiss
- Thermostat Warmup
- Thermostat Sinustec
- Thermostat Rose LM
- Thermostat Agpo Ferroli
- Thermostat Amfra
- Thermostat Aube
- Thermostat AWB
- Thermostat Wattio
- Thermostat Brink
- Thermostat 2Heat
- Thermostat Bryant
- Thermostat Veria
- Thermostat Innogy
- Thermostat ELKO
- Thermostat MundoControl
- Thermostat Bearware
- Thermostat GENERAL Life
- Thermostat Oreg
Neueste Bedienungsanleitung für -Kategorien-
16 Oktober 2024
7 Oktober 2024
5 Oktober 2024
5 Oktober 2024
5 Oktober 2024
5 Oktober 2024
4 Oktober 2024
3 Oktober 2024
2 Oktober 2024
2 Oktober 2024