Vemer Hipnos Bedienungsanleitung

Vemer Thermostat Hipnos

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Vemer Hipnos (2 Seiten) in der Kategorie Thermostat. Dieser Bedienungsanleitung war für 10 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/2
Press
Pull
Press
LCD DISPLAY
Mod. HIPNOS
V3IS00377-020-092020
Vemer S.p.A.
I - 32032 Feltre (BL) • Via Camp Lonc, 16
e-mail: info@vemer.it - web site: www.vemer.it
User Manual
DAILY CHRNOTHERMOSTAT WITH CURSORS
Read all instructions carefully
Q The wall-mounted electronic chronothermostat is an automatic control device for daily HIPNOS
thermoregulation.
It performs actions of type 1B and is suitable for environments with a pollution degree 2 and overvoltage
category III (EN60730-1).
SAFETY INSTRUCTIONS
During installation and operation of the product, it is necessary to comply with the following
instructions:
1) The instrument must be installed by a skilled person, in strict compliance with the
connection diagrams.
2) Do not power on or connect the instrument if any part of it is damaged.
3) After installation, inaccessibility to the connection terminals without appropriate tools
must be granted.
4) The instrument must be installed and activated in compliance with current electric systems
standards.
5) Before accessing the connection terminals, verify that the leads are not live.
Code Model Description
VE013900 Hipnos Wall-mounting daily chronothermostat - White
VE075800 Hipnos Grigio Wall-mounting daily chronothermostat - Grey
TECHNICAL SPECIFICATIONS
Power supply voltage: 2x1,5V (AA) alkaline batteries
Battery autonomy: over two years
Battery level indication with “dead battery” sign
Bistable switchover relay output: maximum capacity from 5A to 250V AC under resistive charge
“Summer” and “winter” operation modes
Temperature adjustment type: ON/OFF with differential to be adjusted from 0,1 to 1°C
PROPORTIONAL-type temperature control, band and period to be congured
Resolution of temperature reading: 0,1°C
Accuracy: ±0,5°C
°C/°F display selection
Temperature measurement updated every 60s
Range of measured temperature: 0°C ÷ 50°C
Temperature control range: 2°C ÷ 36°C
Range of timed operation: 0 ÷ 99 hours / 0 ÷ 99 days
Operating temperature: 0°C ÷ 50°C
Storage temperature: -10°C ÷ 65°C
Readings on LCD display
Protection degree: IPXXD
OPERATIONAL SPECIFICATIONS
CONTROLS
SWITCH-ON RESET AND BATTERY REPLACEMENT
When starting the device for the rst time, place the batteries (see gure C) and reset the device using the ad
hoc key. After a few seconds, the clock setup page will be displayed (see “Clock setup”).[R]
When the batteries are about to be dead the symbol will ash: actuation is not guaranteed when the
batteries are not replaced. As soon as the new batteries are in place, the chronothermostat will resume
operation with all the previous settings, current time included. If battery replacement took longer and the
previous settings were not kept, press the reset key and set up the clock again.[R]
Warning: incorrect battery positioning may damage the device and run down the batteries.
To restore the default parameter values, press the reset key and the [R] key within 3 seconds. the display
will read GH).
Default parameters are:
parameter default
temperature control type: ON/OFF
control band 0.5°C
period 10
antifreeze temperature 6°C
winter differential 0.3°C
summer differential 0.3°C
operation winter
measurement unit °C
CLOCK SETUP
To access the clock setup page push the key: the eld to be modied will ash. Use keys and/or to
modify the eld, push the key to conrm and move on to the next eld. To exit clock setup push the
key again.
OPERATION
When in normal operation mode, the thermostat periodically measures the temperature in the room HIPNOS
in which it is installed and controls temperature based on the previously set parameters. Default temperature
control is ON/OFF type, with a selectable differential.
When in winter operation it is possible to select the PROPORTIONAL control mode, which follows the control
band value as congured (the temperature span in which climate control is performed) and the value set for the
control period (duration of the control cycle).
Key Automatic/Manual
There are two operation options: automatic (different temperatures according to the time of the day) and
manual (one temperature all through the day): when in manual operation mode the symbol is lit.
To switch from automatic to manual, push the key. To view the temperature control setting, press the
key when in manual mode. To switch back to automatic, hold the key down for at least 3 seconds.
Key Summer/Winter
It is possible to congure relay operation to command a heating or cooling unit. To select this function, push
the key; to select operation, push the and/or key; to conrm and return to normal operation press
.
Setpoint programming
When in automatic operation, climate control uses 15 temperature levels, depending on the position of the
cursors .
Temperature selection during the day uses 24 cursors; the temperature value is selected by moving the cursors
along the appropriate rails until they are in the desired position.
To view the temperature associated to the cursor corresponding to the current time, press ; at this stage
it is possible to schedule an actuation delay – with 15’ steps – using the keys and/or . To view the
temperature associated to the next cursors or change actuation delays press . To switch back to normal
operation, press conrmation key .
When in manual operation mode, climate control uses one temperature level only (with different winter and
summer levels), depending on the position of the manual setpoint knob .
To view the temperature setpoint press key . To exit the reading or change, press again.
When in the setpoint view or change page the symbol is lit.
Note: while changing setpoint, temperature control and relay actuation are discontinued.
SWITCH OFF
To disable climate control totally press and ensure that the symbol lights up. If the device is in winter
operation mode, the antifreeze function is however guaranteed according to the relevant temperature setting
(see “Advanced programming”).
To switch the device back on, press again.
TIMED OPERATION
Timed automatic
When in automatic operation it is possible to schedule manual operation mode for a certain time span, after
which the device will go off.
To enable timed automatic operation, hold down the key for at least 3 seconds, until the delay setup page
appears; adjust the delay as explained below (see “Timer programming”).
When in timed automatic operation mode the key for at least 3 seconds, until the delay setup page appears;
adjust the delay as explained below (see “Timer programming”).
When in timed automatic operation mode the symbol is lit.
To terminate timed operation quickly, enable the manual mode or off mode.
Dimension (A)
Wiring diagram (B)
Installation (C)
145
145
145
145
145
93.5
93.5
93.5
93.5
93.5
33.5
33.5
33.5
33.5
33.5
Timed manual operation
It is possible to schedule manual operation mode for a certain time span, after which the device will
resume automatic operation.
To enable timed manual operation, switch to manual operation (press the key), hold down the key
for at least 3 seconds, until the delay setup page appears; adjust the delay as explained below (see “Timer
programming”).
When in timed manual operation, the symbols and are lit.
To quickly terminate timed operation and return to automatic, hold down the key for at least 3
seconds.
Timed switch-off
When in automatic operation it is possible to put climate control off for a certain programmed time span,
after which the device will resume the previous operation mode.
To enable timed switch off, switch to off mode (press ) and hold down the key for at least 3
seconds, until the delay setting page appears; then set up the delay as explained below (see “Timer
programming”).
When in timed switch-off mode the symbols and are lit.
To quickly terminate timed operation and return to the previous operation mode, press .
Timer programming
To set a delay in hours (eld marked ), use the “ ”K and/or key when in the delay programming
page and press to conrm. To set a delay in days, when the hour page appears move to the day page
by pressing the key (the display will read instead of “ ”GK) and proceed as explained for the hour
delay.
During timed operation it is possible to view and change the remaining delay: go to the relevant setup
page (hold down the key for at least 3 seconds) and proceed as explained above.
Note: timings expressed in hours expire when the last hour ends; timings expressed in days run
out at midnight.
MINIMUM AND MAXIMUM TEMPERATURE
To view the maximum daily temperature press : to set the value to zero, hold the same key down for at
least 3 seconds until three dashes appear.
To view the minimum daily temperature pres : to set the value to zero hold the same key down for at
least 3 seconds until three dashes appear.
ADVANCED PROGRAMMING
To access the advanced programming menu, view and congure some parameters, hold down the key
for at least 3 seconds. The display will show the rst page, i.e. the temperature control type. Use the
and/or key to change the value assigned to the selected parameter. Press to conrm the change
and move on to the next parameter.
ON-OFF/PROPORTIONAL selection
This selection is only enabled when in winter mode:
- U(* : ON-OFF temperature control (default)
- U(* 3: PROPORTIONAL temperature control
Control band and period selection
This selection is only enabled when in PROPORTIONAL temperature control type:
- EQG: i.e. control band, varying from 0,5 to 5,0°C ( value 0,5°C)default
-3(U: i.e. control period, varying from 10’ – 20’ –30’ ( value 10’)default
Setting up the control differential
This selection is only enabled when in ON-OFF temperature control type:
- G,): i.e. control differential, varying from 0,1 to 1°C ( value 0,3°C)default
Antifreeze temperature selection
This selection is only enabled when in winter mode:
- )): Antifreeze temperature, varying from 1 to 10°C ( value 6°C)default
°C/°F selection
To select the unit of measurement for the temperature reading:
- GHJ°C: degrees Celsius (default)
- GHJ°F: degrees Fahrenheit
Operation hour count
Reads the system operation hours – a 6 digit reading - (when the relay is in ON status). To zero the hour
count press for 3 seconds
Battery level reading:
Reads the battery charge percentage (3-digit reading).
REFERENCE STANDARDS
Compliance with Community Directives
2014/35/EU (LVD)
2014/30/EU (EMCD)
is declared with reference to the following harmonized standards:
EN 60730-2-7, EN 60730-2-9
EN 61000-6-1, EN 61000-6-3
Manual/automatic selection key
Value up (or forward) key
Conrm/program key
Value down (or back) key
Reset key [R]
Clock/timer key
Summer/Winter key
On/off key
Manual setpoint knob
Daily programming cursors
OFF symbol
Cooling symbol
Heating symbol
Setpoint symbol
Timer symbol
Battery low symbol
Manual symbol
1 2 3
5A / 250V~
NANCCOM
2
1
9
6
5
10
7
8
3
4


Produktspezifikationen

Marke: Vemer
Kategorie: Thermostat
Modell: Hipnos

Brauchst du Hilfe?

Wenn Sie Hilfe mit Vemer Hipnos benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Thermostat Vemer

Bedienungsanleitung Thermostat

Neueste Bedienungsanleitung für -Kategorien-