Velleman DVM860BL Bedienungsanleitung
Velleman
Multimeter
DVM860BL
Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Velleman DVM860BL (54 Seiten) in der Kategorie Multimeter. Dieser Bedienungsanleitung war für 13 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet
Seite 1/54

DVM860BL VELLEMAN - 1 -
DVM860BL – DIGITAL MULTIMETER
1. Introduction
At the end of its life cycle, dispose of this product in accordance with local and national disposal
regulations. Read the manual thoroughly before bringing this device into service
Thank you for buying the ! Use this device to measure and test: AC & DC voltage & current (also with DVM860BL
optional clamp ), resistance, temperature, batteries, diodes, continuity and transistors. AC97
2. Safety
The is developed in accordance with IEC1010-1 concerning safety requirements for electrical measuring DVM860BL
instruments with an overvoltage category (CAT III) 600V and pollution 2. Respect these safety prescriptions:
• Protect yourself against electroshocks.
• Do not use this device for any other application than those described in this manual.
• Make sure the device was not damaged in transit.
• Make sure the insulation of the test leads is not damaged and/or the wire itself is not exposed.
• Full compliance with safety standards can only be guaranteed if the device is used with the supplied test leads. If
necessary, they should be replaced with identical leads or leads with identical electric ratings. All test leads should
be in good working order.
• Select the right input jack, function and range before use.
• Never exceed the specified limit values for the various measurement ranges.
• Do not touch unused terminals when the meter is connected to a circuit.
• Place the range selector in the highest position if the value to be measured is unknown beforehand.
• Do not measure voltages > 600V above earth ground.
• Exercise extreme caution when working with voltages in excess of 60Vdc or 30Vrms AC. Keep your fingers behind
the probe barriers while using the device.
• Do not connect the leads to a voltage source while the function switch is in one of the following modes: current,
resistance, temperature, battery, diode, transistor or continuity.
• Disconnect all test leads from the circuit to be tested prior to selecting a different function or range.
• Do not use the meter in dusty environments or in the presence of flammable gases and steam.
• Have the device checked by a qualified technician in case of malfunction.
• Never use the meter if the back panel is not in place and firmly fixed.
• Do not use or store the device in areas exposed to direct sunlight, high temperatures or high humidity.
3. Device Description
a. Front Panel
1. LCD display : allows readout of the measured values
2. ON/OFF button : used to activate / deactivate the device
3. RANGE button : used to select auto or manual range
4. FUNC. button : select AC or DC measurement, select °C or °F
5. Selector : used to select the desired function and range
6. 10A jack : input terminal for max. 10A current
7. INPUT jack : input terminal (exception: 10A)
8. COM jack
9. Backlight button ( ) : to illuminates the LCD for a few seconds
10. DATA HOLD button : Displayed data are held
11. MAX HOLD button : Max. measured value is held

DVM860BL VELLEMAN - 2 -
b. Display Symbols
Safety issue,
consult the manual
AC
Alternating current
DC
Direct current
Double insulation
(Protection class II)
AC or DC
Fuse
Earth ground
/
Battery / Battery low
conforms to EU directives
Diode
Continuity buzzer
Measurement with (optional)
clamp
MAX.H
Max. value is being held
DATA-H
Displayed data are held
AUTO
Automatic range selection
CATIII
Overvoltage category III,
pollution degree 2 (IEC1010-1)
4. Maintenance
• Do not remove the back cover while a voltage is being applied. Only a qualified technician should handle repairs.
•
Always disconnect the test leads from all current sources before opening the meter.
• Replace the batteries when the symbol is displayed.
• Replace blown fuses with an identical one or a fuse with identical voltage and current ratings: F 200mA/250V
(quick-acting).
• Use a damp cloth and a mild detergent to clean the device. Never apply abrasives or solvents to the meter
• Place the power switch in the OFF position when the device is not being used
• Remove the batteries to keep them from leaking if the device is to be stored for a long time.
5. Specifications
Max. accuracy is achieved during a one-year period after calibration. Ideal circumstances require a temperature of 18
to 28°C (64 to 82°F) and a max. relative humidity of 75%.
5.1 General Specifications
Sampling Time ±0.4sec.
Display LCD 16mm
Max. Display 1999 points (3 ½ digits)
Polarity Indication "-" indicates negative polarity
Overrange Indication "OL"
Displayed Measuring Unit Unit of electrical capacity
Battery-Low Indication " "-symbol is displayed
Maximum Altitude 7000ft (2000m)
Max. voltage between terminals and earth 600V DC or AC
Fuse Protection F 200mA/250V (quick-acting)
Automatic Power Off 15 minutes
Power Supply 3 x 1.5V AAA-battery
Operating Temperature 0°C to +40°C (+32 to +104°F)
Storage Temperature -10°C to +50°C (+10 to +122°F)
Dimensions 158 x 74 x 32mm
Weight ±250g (batteries included)

DVM860BL VELLEMAN - 3 -
5.2 Electrical Specifications
5.2.1. DC Voltage
Range Resolution Accuracy
200mV 0.1mV
2V 0.001mV
20V 0.01mV
200V 0.1mV
600V 1V
±0.7% of rdg + 2 digits
Input Impedance : 10M Ω
Overload Protection : 250V DC or rms AC for the 200mV-range, 600V DC or V rms AC for the ranges 2V to 600V
Max. Input Voltage : 600V DC
5.2.2. AC Voltage
Range Resolution Accuracy
200mV 0.1mV
2V 0.001mV
20V 0.01mV
200V 0.1mV
±0.8% of rdg + 3 digits
600V 1V ±1.0% of rdg + 3 digits
Input Impedance : 10M Ω
Overload Protection : 250V DC or rms AC for the 200mV-range, 600V DC or AC rms for the ranges 2V to 600V
Frequency Range : 40 to 400Hz
Response : average response, calibration in rms of a sine wave.
Max. Input Voltage : 600V rms AC
5.2.3. DC Current
Range Resolution Accuracy
200µ A 0.1µ A
2000µ A 1µ A
20.00mA 0.01mA
200.00mA 0.1mA
±1.2% of rdg + 3 digits
2.000A 0.001A
10.00A 0.01A
±2.0% of rdg + 10 digits
Overload Protection : F 200mA/250V fuse (quick-acting) for the µA, mA ranges. The 2A and 10A range are unfused.
Max. Input Current : INPUT jack: 200mA, 10A jack: 10A.
Voltage Drop : 200µV, 20mA, 2A: 20mV, 2000µA, 200mA, 10A-range: 200mV.
5.2.4. AC Current
Range Resolution Accuracy
200µ A 0.1µ A
2000µ A 1µ A
20.00mA 0.01mA
200.00mA 0.1mA
±1.5% of rdg + 5 digits
2.000A 0.001A
10.00A 0.01A
±3.0% of rdg + 10 digits
Produktspezifikationen
Marke: | Velleman |
Kategorie: | Multimeter |
Modell: | DVM860BL |
Gewicht: | 250 g |
Abmessungen (BxTxH): | 158 x 74 x 32 mm |
Hintergrundbeleuchtung: | Ja |
Temperaturmessbereich: | -20 - 1000 °C |
Kontinuitätscheck: | Ja |
Data-Hold: | Ja |
DC Spannungsrange: | 0.2 - 600 V |
AC Spannungsrange: | 0.2 - 600 V |
Widerstandsreichweite: | 200 - 20000000 Ohm |
AC Stromreichweite: | 0.0002 - 10 A |
DC Stromreichweite: | 0.0002 - 10 A |
Basic accuracy (AC Spannung): | ±(1.5%+5d), ±(3.0%+10d) |
Basic accuracy (DC Elektrizität): | ±(1.2%+3d), ±(2.0%+10d) |
Basic accuracy (Widerstand): | ±(1.0%±3d), ±(1.0%±1d), ±(1.0%±5d) |
Basic accuracy (DC Spannung): | ±(0.7%+2d) |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Velleman DVM860BL benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Multimeter Velleman

5 Oktober 2024

5 Oktober 2024

23 September 2024

28 August 2024

23 August 2024

15 August 2024

9 August 2024

8 August 2024

2 August 2024

1 August 2024
Bedienungsanleitung Multimeter
- Multimeter Basetech
- Multimeter Gembird
- Multimeter Brennenstuhl
- Multimeter Clas Ohlson
- Multimeter Profile
- Multimeter REV
- Multimeter Voltcraft
- Multimeter Bosch
- Multimeter Laserliner
- Multimeter Powerfix
- Multimeter Alecto
- Multimeter EMOS
- Multimeter TFA
- Multimeter FERM
- Multimeter Topcraft
- Multimeter Schneider
- Multimeter Tacklife
- Multimeter Abus
- Multimeter Elro
- Multimeter Stanley
- Multimeter Perel
- Multimeter Wago
- Multimeter Workzone
- Multimeter Somogyi
- Multimeter Amprobe
- Multimeter Metrix
- Multimeter Maxwell
- Multimeter Silverline
- Multimeter Yato
- Multimeter Brandson
- Multimeter Keithley
- Multimeter Hager
- Multimeter Kyoritsu
- Multimeter GW Instek
- Multimeter Monacor
- Multimeter Brüder Mannesmann
- Multimeter Milwaukee
- Multimeter JUNG
- Multimeter Testo
- Multimeter Elma
- Multimeter IDEAL
- Multimeter Digitus
- Multimeter Kingcraft
- Multimeter Testboy
- Multimeter Projecta
- Multimeter Greenlee
- Multimeter Multimetrix
- Multimeter Extech
- Multimeter BENNING
- Multimeter Metrel
- Multimeter Högert
- Multimeter APPA
- Multimeter Fluke
- Multimeter FLIR
- Multimeter Aldi
- Multimeter Gossen Metrawatt
- Multimeter Hubinont
- Multimeter Joy-it
- Multimeter Kewtech
- Multimeter Mastech
- Multimeter Megger
- Multimeter Micronta
- Multimeter PCE Instruments
- Multimeter Plieger
- Multimeter Sanwa
- Multimeter Skandia
- Multimeter Sonel
- Multimeter Steren
- Multimeter Uni-T
- Multimeter Wiha
- Multimeter Vimar
- Multimeter Owon
- Multimeter PeakTech
- Multimeter Amiko
- Multimeter Rigol
- Multimeter HT Instruments
- Multimeter Beha-Amprobe
- Multimeter Chauvin Arnoux
- Multimeter Aim TTi
- Multimeter Etekcity
- Multimeter Rohde & Schwarz
- Multimeter Strex
- Multimeter MBS
- Multimeter Kurth Electronic
- Multimeter Weidmüller
- Multimeter CEM
- Multimeter Klein Tools
- Multimeter Dasqua
- Multimeter Horex
- Multimeter Enovalab
- Multimeter Qian
- Multimeter Digi-tool
- Multimeter MGL Avionics
- Multimeter Cosinus
- Multimeter Weltron
- Multimeter EEVBlog
- Multimeter Caltek
- Multimeter Elworks
- Multimeter Bearware
- Multimeter Noyafa
Neueste Bedienungsanleitung für -Kategorien-

16 Oktober 2024

16 Oktober 2024

16 Oktober 2024

16 Oktober 2024

16 Oktober 2024

13 Oktober 2024

9 Oktober 2024

3 Oktober 2024

1 Oktober 2024

27 September 2024