DVM6013 VELLEMAN 1
DVM6013 – DIGITAL CAPACITANCE METER
1. General
a) Introduction
Thank you for buying the DVM6013. This digital capacitance meter gives a direct reading of capacitance on a 3 ½-
digit LCD display. Nine ranges provide precise readings from 0.1pF to 20mF, which includes virtually all capacitors
used in maintenance services, schools, etc. The DVM6013’s limited weight and small size make it a user-friendly
device.
b) Features
• LCD display with character height 21mm, 1999 counts.
• 9 ranges from 200pF to 20mF
• very accurate measurements
• external zero adjuster : ±20pF
• dual-slope integration A/D converter
• overload indication : “1”
• safe test probes
• dimensions : 31.5 x 91 x 189mm (H x W x L)
• weight : 240g (battery included)
2. Specifications
Maximum accuracy is achieved during a one-year period after calibration. Ideal circumstances require an operating
temperature of 18 to 28°C (64 to 82°F).
Power Supply 9V-battery NEDA1604 or 6F22 006P
Battery-Low Indication the “ ” symbol is displayed
Fuse 200mA/250V
Excitation Voltage 2.8V peak MAX
Operating Temperature 0 to +40°C (+32 to +104°F)
Storage Temperature -10 to +50°C (+14 to +122°F)
Range Resolution Accuracy Test Frequency
200pF 0.1pF ± 0.5% of full scale ± 1 digit 800Hz
2nF 1pF ± 0.5% of full scale ± 1 digit 800Hz
20nF 10pF ± 0.5% of full scale ± 1 digit 800Hz
200nF 100pF ± 0.5% of full scale ± 1 digit 800Hz
2 F µ1000pF ± 0.5% of full scale ± 1 digit 800Hz
20 F µ0.01µ F ± 0.5% of full scale ± 1 digit 80Hz
200 F µ0.1µ F ± 0.5% of full scale ± 1 digit 8Hz
2000 F µ1µF ± 1.0% of full scale ± 1 digit 8Hz
20mF 10µ F ± 2.0% of full scale ± 2 digits 8Hz
DVM6013 VELLEMAN 2
3. Front Panel Description
1. LCD display
2. rotary switch
3. zero adjuster
4. input jacks
4. Operating Instructions
WARNING
• Make sure that the battery is correctly inserted into the battery compartment and connected to the battery snaps.
• Observe the polarity indications when connecting polarised capacitors. Discharge all capacitors fully.
• Do not apply any voltage to the test jacks because serious damage may ensue.
• Do not short the test leads together as this will increase the battery’s power consumption drastically. The LCD will
display an overrange indication for all ranges.
OPERATION
• If no capacitance value is displayed : start with the 200pF-range and select the next range until the overrange
indication is replaced by an actual measured value.
• A shorted capacitor generates an overrange indication on all ranges. A capacitor with a low leakage voltage will
generate either an overrange indication or an unusually high measured value. With an open capacitor, the display
will read “0” for every range (possibly just a few pF for the 200pF-range).
• Measure very low capacitances using very short leads or the capacitor-measuring socket above the input jacks on
the front panel. This will allow you to avoid introducing any stray capacitance.
• When using the optional test leads to measure small values, you should keep in mind that the leads may
introduce a small capacitive charge. Connect the leads and check the display. Subtract the displayed value from
the eventual measuring result. Obviously, it would be easier to use the zero adjuster on the front panel…
• Capacitors, and electrolytic capacitors in particular, are notorious for their great tolerance. You should not be
surprised, therefore, if the measured value is higher than the value on the capacitor, unless when using a
capacitor with low tolerance. However, only on the rarest of occasions will the measured value be much lower
than the rated value.
• You can locate a leaking capacity if the value changes considerably when you select a different scale. The effect
of the internal leakage resistance is limited in the lower ranges.
DVM6013 VELLEMAN 3
CAPACITANCE MEASUREMENTS
1. Select the desired range.
2. When selecting the 200pF-, 2nF- or 20nF range, you should adjust the zero prior to connecting the capacitor in
question but after connecting the test leads. The zero adjuster can make a max. adjustment of ± 20pF.
3. Connect the capacitor to the measuring socket through the alligator clips or insert it directly into the measuring
socket above the input jacks on the front panel.
4. The measured value is displayed directly on the LCD and the electrical unit is indicated (pF, nF, µ F, mF). The
number “1” indicates that the measured value is outside the selected range (“overrange indication”). If the
measured value has one or more leading zeros, you should select a lower range in order to improve the
resolution of the measurement.
5. Place the rotary adjustment in the OFF-position after use.
5. Maintenance
• Replace the battery when the “ ” symbol is displayed. Remove the screws on the back cover and open the
case. Insert a new 9V-battery (NEDA1604 or 6F22 006P) and close the battery compartment.
• The fuse only rarely needs to be replaced. A blown fuse is nearly always the result of an operator error. Open the
case, then take the PCB out from the front cover. Replace the blown fuse with a new one with the same ratings
(200mA/250V quick-acting).
• If any faults or abnormalities are observed, the meter cannot be used anymore and has to be checked out.
• Never use the meter unless the back cover is in place and fully fastened.
• Do not use abrasives or solvents on the meter, use only a damp cloth and a mild detergent.
6. Accessories
The DVM6013 is supplied with test leads, a 9V-battery (NEDA 1604 or 6F22 006P), a manual and a holster. The
holster can be used to place the device upright on a table or to hang it from a nail in the wall.
DVM6013 – DIGITALE CAPACITEITSMETER
1. Algemeen
a) Inleiding
Dank u voor uw aankoop ! Deze digitale capaciteitsmeter heeft een 3 ½-digits LCD waarop u het resultaat van uw
metingen kunt aflezen. Dankzij z’n 9 bereiken voor precisiemetingen van 0.1pF tot 20mF is dit toestel geschikt voor
bijna elk type van condensator dat wordt gebruikt in scholen, onderhoudsdiensten, enz. Dit is een
gebruikersvriendelijk toestel dankzij het lichte gewicht en de kleine afmetingen.
b) Kenmerken
• LCD display met karakterhoogte 21mm, 1999 punten.
• 9 bereiken van 200pF tot 20mF
• zeer precieze metingen
• externe nulregeling : ±20pF
Produktspezifikationen
Marke: | Velleman |
Kategorie: | Multimeter |
Modell: | DVM6013 |
Gewicht: | 240 g |
Abmessungen (BxTxH): | 31.5 x 91 x 189 mm |
Hintergrundbeleuchtung: | Nein |
Data-Hold: | Nein |
Kapazitätsreichweite: | 0.2 - 20000000 nF |
Basic accuracy (Kapazität): | ± 0.5% |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Velleman DVM6013 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Multimeter Velleman
5 Oktober 2024
5 Oktober 2024
23 September 2024
28 August 2024
23 August 2024
15 August 2024
9 August 2024
8 August 2024
2 August 2024
1 August 2024
Bedienungsanleitung Multimeter
- Multimeter Basetech
- Multimeter Gembird
- Multimeter Brennenstuhl
- Multimeter Clas Ohlson
- Multimeter Profile
- Multimeter REV
- Multimeter Voltcraft
- Multimeter Bosch
- Multimeter Laserliner
- Multimeter Powerfix
- Multimeter Alecto
- Multimeter EMOS
- Multimeter TFA
- Multimeter FERM
- Multimeter Topcraft
- Multimeter Schneider
- Multimeter Tacklife
- Multimeter Abus
- Multimeter Elro
- Multimeter Stanley
- Multimeter Perel
- Multimeter Wago
- Multimeter Workzone
- Multimeter Somogyi
- Multimeter Amprobe
- Multimeter Metrix
- Multimeter Maxwell
- Multimeter Silverline
- Multimeter Yato
- Multimeter Brandson
- Multimeter Keithley
- Multimeter Hager
- Multimeter Kyoritsu
- Multimeter GW Instek
- Multimeter Monacor
- Multimeter BrĂĽder Mannesmann
- Multimeter Milwaukee
- Multimeter JUNG
- Multimeter Testo
- Multimeter Elma
- Multimeter IDEAL
- Multimeter Digitus
- Multimeter Kingcraft
- Multimeter Testboy
- Multimeter Projecta
- Multimeter Greenlee
- Multimeter Multimetrix
- Multimeter Extech
- Multimeter BENNING
- Multimeter Metrel
- Multimeter Högert
- Multimeter APPA
- Multimeter Fluke
- Multimeter FLIR
- Multimeter Aldi
- Multimeter Gossen Metrawatt
- Multimeter Hubinont
- Multimeter Joy-it
- Multimeter Kewtech
- Multimeter Mastech
- Multimeter Megger
- Multimeter Micronta
- Multimeter PCE Instruments
- Multimeter Plieger
- Multimeter Sanwa
- Multimeter Skandia
- Multimeter Sonel
- Multimeter Steren
- Multimeter Uni-T
- Multimeter Wiha
- Multimeter Vimar
- Multimeter Owon
- Multimeter PeakTech
- Multimeter Amiko
- Multimeter Rigol
- Multimeter HT Instruments
- Multimeter Beha-Amprobe
- Multimeter Chauvin Arnoux
- Multimeter Aim TTi
- Multimeter Etekcity
- Multimeter Rohde & Schwarz
- Multimeter Strex
- Multimeter MBS
- Multimeter Kurth Electronic
- Multimeter WeidmĂĽller
- Multimeter CEM
- Multimeter Klein Tools
- Multimeter Dasqua
- Multimeter Horex
- Multimeter Enovalab
- Multimeter Qian
- Multimeter Digi-tool
- Multimeter MGL Avionics
- Multimeter Cosinus
- Multimeter Weltron
- Multimeter EEVBlog
- Multimeter Caltek
- Multimeter Elworks
- Multimeter Bearware
- Multimeter Noyafa
Neueste Bedienungsanleitung fĂĽr -Kategorien-
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
13 Oktober 2024
9 Oktober 2024
3 Oktober 2024
1 Oktober 2024
27 September 2024