Trotec PAC 3550 PRO Bedienungsanleitung

Trotec Klimaanlage PAC 3550 PRO

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Trotec PAC 3550 PRO (24 Seiten) in der Kategorie Klimaanlage. Dieser Bedienungsanleitung war für 32 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/24
TRT-BA-PAC3550PRO-TC-001-EN
PAC 3550 PRO
EN
OPERATING MANUAL
LOCAL AIR CONDITIONER
1 EN
Operating manual – local air conditioner PAC 3550 PRO
Table of contents
Notes regarding the operating manual.................................1
Safety .....................................................................................2
Information about the device................................................3
Transport and storage...........................................................5
Assembly and installation.....................................................5
Operation ...............................................................................9
Errors and faults..................................................................13
Maintenance ........................................................................15
Technical annex...................................................................18
Disposal ...............................................................................20
Notes regarding the operating manual
Symbols
Warning of electrical voltage
This symbol indicates dangers to the life and health of
persons due to electrical voltage.
Warning!
This signal word indicates a hazard with an average
risk level which, if not avoided, can result in serious
injury or death.
Caution!
This signal word indicates a hazard with a low risk
level which, if not avoided, can result in minor or
moderate injury.
Note
This signal word indicates important information
(e.g. material damage), but does not indicate hazards.
Info
Information marked with this symbol helps you to carry
out your tasks quickly and safely.
Follow the manual
Information marked with this symbol indicates that the
operating manual must be observed.
The current version of the operating manual can be found at:
PAC 3550 PRO
http://download.trotec.com/?sku=1210002110&id=1
Legal notice
This release replaces all previous versions. No part of this
publication may be reproduced without written permission from
TrotecGmbH&Co.KG. The same applies for electronically
processing, duplicating or spreading the publication. Subject to
technical changes. All rights reserved. Trademarks are used
without guarantee that they may be used freely and primarily
following the spelling of the manufacturer. Product names are
registered.
Changes to construction in the interests of constant
improvements to the product, as well as changes to the shape
and colour are reserved.
The scope of delivery may vary from product images. This
document was created with all due care. TrotecGmbH&Co.KG
accepts no liability whatsoever for possible mistakes or
omissions.
© TrotecGmbH&Co.KG
EN 2
Operating manual – local air conditioner PAC 3550 PRO
Warranty and liability
The device complies with the fundamental health and safety
requirements of the applicable EU regulations and was tested at
the factory for perfect functionality multiple times.
However, if faults in the functionality occur and cannot be
remedied with the measures in the chapter Errors and faults,
please get in touch with your dealer or distributor.
When making a warranty claim, supply the device number (see
the rear of the device).
When manufacturer's instructions or legal regulations have not
been followed, or after unauthorised changes to the device are
made, the manufacturer is not responsible for the resulting
damages. Changes to the device or unauthorised replacement
of individual parts can drastically impact the electrical safety of
this product and will result in the loss of the warranty. Liability
does not extend to damages to people or property caused by the
device being used other than as described in the instructions in
this operating manual. Subject to changes to technical design
and model changes as part of constant development and
product improvement without prior notice.
No liability is accepted for damages resulting from improper
use. In such a case, any warranty claims will be voided also.
Safety
Read this manual carefully before starting or using the
device. Always store the manual in the immediate vicinity
of the device or its site of use!
• Do not use the device in potentially explosive rooms.
• Do not use the device in aggressive atmosphere.
• Set the device up in an upright and stable position.
• Let the device dry out after a wet clean. Do not operate it
when wet.
• Do not use the device with wet or damp hands.
• Do not expose the device to directly squirting water.
• Never insert any objects or limbs into the device.
• Do not cover or transport the device during operation.
• Do not sit on the device.
• This appliance is not a toy! Keep away from children and
animals. Do not leave the device unattended during
operation.
• Check accessories and connection parts for possible
damage prior to every use of the device. Do not use any
defective devices or device parts.
• Ensure that all electric cables outside of the device are
protected from damage (e.g. caused by animals). Never
use the device if electric cables or the power connection
are damaged!
• The electrical connection must correspond to the
specifications in chapter Technical data.
• Insert the mains plug into a properly secured mains
socket.
• Observe the technical data when selecting extensions to
the power cable. Completely unroll the extension cable.
Avoid electrical overload.
• Before carrying out maintenance, care or repair work on
the device, remove the mains plug from the mains socket.
Hold onto the mains plug while doing so.
• Switch the device off and disconnect the power cable from
the mains socket when the device is not in use.
• Do not under any circumstances use the device if you
detect damages on the mains plug or power cable.
Defective power cables pose a serious health risk.
• Observe the storage and operating conditions (see chapter
Technical data).
• Ensure that the air inlet and outlet are not obstructed.
• Ensure that the side of the device where the air inlet is
found is kept free of dirt and loose objects.
• Only transport the device in an upright position with an
emptied condensation tank or drain hose.
• Discharge the collected condensate before transport and
storage. Do not drink it. Health hazard!


Produktspezifikationen

Marke: Trotec
Kategorie: Klimaanlage
Modell: PAC 3550 PRO
Display-Typ: LED
Breite: 470 mm
Tiefe: 430 mm
Gewicht: 34000 g
Produktfarbe: Silber
Höhe: 840 mm
Lenkrollen: Ja
AC Eingangsspannung: 230 V
AC Eingangsfrequenz: 50 Hz
Eingebautes Display: Ja
Typ: Einteilige mobile Klimaanlage
Kabellänge: 1.8 m
Anschlusswert: 1300 W
Stromstärke: 10 A
Kältemittelart: R410A
Geräuschpegel: 62 dB
Kühlmittelgewicht: 685 g
Griff(e): Ja
Geeignet bis zu Zimmergrößen von: 115 m³
Geeignet für Räume bis zu: 45 m²
Klimaanlage Funktionen: Cooling, Dehumidifying, Ventilating
Kühlleistung (max): 12000 BTU/h
Kühlkapazität in Watt (nominal): - W
Kühlleistung in Watt (max): 3500 W
Heizkapazität in Watt (nominal): - W
Heizleistung in Watt (max): - W
Luftstrom (hohe Geschwindigkeit): 380 m³/h
Energieeffizienzklasse (Kühlen): A
Energieverbrauch pro Stunde (Kühlung): 1.3 kWh
Energieverbrauch pro Stunde (Heizung): - kWh
Jährlicher Energieverbrauch (Kühlung): - kWh
Schlauchlänge: 1.5 m
Schlauchdurchmesser: 150 mm
Schlafmodus: Ja
Kühlung Energieeffizienz: 2.7
Deshumidifizierende Kapazität: 1.3 l/h