Taylor 5329 Bedienungsanleitung


Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Taylor 5329 (1 Seiten) in der Kategorie Thermometer. Dieser Bedienungsanleitung war für 7 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/1
COMPLETE ONE YEAR LIMITED WARRANTY
www.taylorusa.com
# 5329
©2018 Taylor Precision Products
Oak Brook, IL 60523
5329_4.26.18
Made in China
Place
Sticker
Here
INDOOR / OUTDOOR
THERMOMETER WITH HYGROMETER
Large, easy-to-read numbers
Humidity and temperature readings from inside
Indoor & outdoor temperature range: -50°F to 120°F / -45°C to 50°C
Indoor humidity range: 10%-80%
EXPOSURE:
Do not mount in direct sunlight, near a heat source, or near a large body of
water as these situations could affect the proper air temperature reading.
Ultraviolet light from sunlight can prematurely weather the product.
SEPARATED FLUID:
Under normal shipping conditions, the Permacolo
liquid in this thermometer may become separated. When
this occurs, the thermometer will not read accurately.
Should one of the tubes read substantially lower than the
other, it may be due to the fact that the liquid has
become separated, and is at the extreme top of the tube.
Such separation does not represent defect or damage.
The column may be reunited as follows:
1. Hold thermometer as shown in Fig. 2, supporting the
coil of tubing
2. Tap edge of thermometer lightly against palm of other
hand
3. Continue to tap lightly until column is reunited
MOUNTING INSTRUCTIONS:
Choose a window near which the thermometer is to be
installed, and where the bulb will be shielded from the
sun's rays. (North side is preferable for true air
temperature readings).
The tubing which connects the bulb to the outdoor
scale is liquid filled. Do not cut, disconnect or sharply
bend in a manner which may restrict the flow of liquid.
Make certain location chosen will permit ample tubing
to run along the window casing and over the frame as
illustrated (Fig. 1). For maximum accuracy, exactly 12"
(30.5cm) of tubing should be exposed to the outside
temperature.
Use the template guide at right to locate position for
mounting screws. Hold template against wall at location
selected for thermometer. Punch through cardboard at both dots until heads are
about 1/8" (2.8mm) from surface. Hang thermometer by means of keyhole slots in
backplate.
Form tubing over window casing as illustrated in Fig. 1, avoiding sharp bending.
Select either an upper or lower corner. Closing of the window must not crush the
tubing; if sufficient clearance does not exist, a small notch or groove should be
made with saw or file to provide for this. The same provision for clearance should be
made in storm sash of either permanent or removable type.
Using small screws , fasten outside bulb bracket and insert bulb.
FIG. 1
FIG. 2
REJOINING
SEPARATED FL UID
MOUNTING SCREWS TEMPL AT E - 4 1/2 INCHES
BLACK


Produktspezifikationen

Marke: Taylor
Kategorie: Thermometer
Modell: 5329

Brauchst du Hilfe?

Wenn Sie Hilfe mit Taylor 5329 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Thermometer Taylor

Bedienungsanleitung Thermometer

Neueste Bedienungsanleitung für -Kategorien-