Smeg SV564EB-4 Bedienungsanleitung

Smeg Ofen SV564EB-4

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Smeg SV564EB-4 (20 Seiten) in der Kategorie Ofen. Dieser Bedienungsanleitung war für 16 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/20
Contents
THESE INSTRUCTIONS ARE VALID ONLY FOR END USER COUNTRIES WHOSE
IDENTIFICATION SYMBOLS APPEAR ON THE COVER OF THIS MANUAL.
qualified
technician
Introduction
1. INSTRUCTIONS FOR SAFE AND PROPER USE
THIS MANUAL IS AN INTEGRAL PART OF THE APPLIANCE AND
THEREFORE MUST BE KEPT IN ITS ENTIRETY AND IN AN ACCESSIBLE
PLACE FOR THE WHOLE WORKING LIFE OF THE COOKING HOB. WE
ADVISE READING THIS MANUAL AND ALL THE INSTRUCTIONS THEREIN
BEFORE USING THE COOKING HOB. ALSO KEEP THE SERIES OF NOZZLES
SUPPLIED. INSTALLATION MUST BE CARRIED OUT BY QUALIFIED
PERSONNEL IN ACCORDANCE WITH THE REGULATIONS IN FORCE. THIS
APPLIANCE IS INTENDED FOR DOMESTIC USES AND CONFORMS TO
CURRENT REGULATIONS IN FORCE. THE APPLIANCE HAS BEEN BUILT TO
CARRY OUT THE FOLLOWING FUNCTIONS: COOKING AND HEATING-UP
OF FOOD. ALL OTHER USES ARE CONSIDERED IMPROPER.
THE MANUFACTURER DECLINES ALL RESPONSIBILITY FOR IMPROPER
USE.
DO NOT LEAVE THE PACKING IN THE HOME ENVIRONMENT. SEPARATE
THE VARIOUS WASTE MATERIALS AND TAKE THEM TO THE NEAREST
SPECIAL GARBAGE COLLECTION CENTRE.
IT IS OBLIGATORY FOR THE ELECTRICAL SYSTEM TO BE GROUNDED
ACCORDING TO THE METHODS REQUIRED BY SAFETY RULES.
THE PLUG TO BE CONNECTED TO THE POWER CABLE AND THE SOCKET
MUST BE THE SAME TYPE AND MUST CONFORM TO CURRENT
REGULATIONS.
THE SOCKET MUST BE ACCESSIBLE AFTER THE APPLIANCE HAS BEEN
BUILT IN.
NEVER UNPLUG BY PULLING ON THE CABLE.
IMMEDIATELY AFTER INSTALLATION CARRY OUT A BRIEF INSPECTION
TEST OF THE COOKING HOB, FOLLOWING THE INSTRUCTIONS BELOW.
SHOULD THE APPLIANCE NOT FUNCTION, DISCONNECT IT FROM THE
SUPPLY AND CALL THE NEAREST TECHNICAL ASSISTANCE CENTRE.
NEVER ATTEMPT TO REPAIR THE APPLIANCE.
ALWAYS CHECK THAT THE CONTROL KNOBS ARE IN THE POSITION
"ZERO" (OFF) WHEN YOU FINISH USING THE HOB.
Introduction
THE IDENTIFICATION PLATE, WITH TECHNICAL DATA, SERIAL NUMBER
AND MARKING IS CLEARLY VISIBLE UNDER THE CASING.
THE PLATE ON THE CASING MUST NOT BE REMOVED.
BEFORE CONNECTING THE DEVICE, MAKE SURE THAT IT HAS BEEN
REGULATED FOR THE TYPE OF GAS THAT WILL FEED IT, CHECKING THE
LABEL UNDER THE CASING.
DO NOT PUT PANS WITHOUT PERFECTLY SMOOTH AND FLAT BOTTOMS
ON THE COOKING HOB GRIDS.
DO NOT USE RECIPIENTS OR GRIDDLE PLATES THAT EXTEND BEYOND
THE EXTERNAL PERIMETER OF THE HOB.
THE HOB IS TO BE USED BY ADULTS ONLY. DO NOT LET UNSUPERVISED
CHILDREN PLAY WITH THE HOB.
THIS APPLIANCE IS MARKED ACCORDING TO THE EUROPEAN DIRECTIVE
2002/96/EC ON WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT
(WEEE).
THIS GUIDELINE IS THE FRAME OF A EUROPEAN-WIDE VALIDITY OF
RETURN AND RECYCLING ON WASTE ELECTRICAL AND ELECTRONIC
EQUIPMENT.
The manufacturer declines all responsibility for damage to persons
or things caused by non-observance of the above prescriptions or by
interference with any part of the appliance or by the use of non-original
spares.
Instructions for the installer
2. POSITIONING OF HOB
2.1.1 Attachment to support structure
Create an opening with the dimensions shown in the figure in the top
surface of the counter, keeping a minimum distance of 50 mm from the
rear border.
This appliance can therefore be mounted against walls higher than the
work surface on condition that a certain distance be kept between the
appliance and the wall as shown in the figure so as to avoid damage from
overheating.
Make sure there is a minimum of 750 mm between the hot plate flames
and any shelf that may be installed directly above them.
A (mm) B (mm) C (mm) D (mm) E (mm) L (mm) X (mm) Y (mm)
MOD.
30 min 150 min 460 min 750 min 50 20÷40 306 252÷255 478÷482
MOD.
60 min 150 min 460 min 750 min 50 20÷40 596 555÷560 478÷482
MOD.
90 min 150 min 460 min 750 min 50 20÷40 886 839÷844 478÷482
Instructions for the installer
Accurately position the gasket provided all around the outer edge of the
hole in the top surface as shown in the figures below, pressing it down so
as to make it adhere properly. For measurements, refer to the figure
depending on the hob model to be installed, bearing in mind that in both
models the front and rear sides must skim the hole. Secure the hob to the
counter with brackets A (supplied). Carefully trim any excess from border
B of the gasket. The distances in the following drawing refer to the hole
on the inner side of the gasket.
In case of installation on a hollow compartment with doors, a separating
panel has to be placed under the hob. Keep a minimum distance of 20
mm between the bottom of the unit and the panel surface. The panel
has to be easily removable to allow access in the event of technical
service.
Instructions for the installer
4. GAS CONNECTION
Connection to the gas mains may be made with a rigid copper pipe or
with a flexible pipe and conforming to the provisions defined by standard
regulations in force.
To facilitate connection, fitting A on the rear of the appliance may be
adjusted laterally. For this purpose, loosen hexagon nut B, turn fitting A
to the desired position, (tightness is ensured and retighten hexagon nut B
by a biconical brass ring). Use a soapy solution to check for proper
tightness. Never use a free flame.
The hob has been inspected for G20 (2H) natural gas at a pressure of
20 mbar. For use with other types of gases, see Section “5.
ADAPTATION TO DIFFERENT TYPES OF GAS”. The gas intake fitting
is ½” gas external threaded (ISO 228-1).
Connection with rigid copper pipe:
the connection to the gas mains must
not provoke stress of any kind on the
hob.
Connection may be made by using
biconical adapter with insertion of D
gasket C (supplied).
Connection with flexible pipe: use
only flexible pipes conforming to
standard regulations in force, inserting
gasket C (supplied) between fitting A
and flexible pipe E.
Instructions for the installer
4.1 Connection to LPG
Use a pressure regulator and make the connection to the tank according
to the provisions of standards regulations in force. Make sure that feed
pressure conforms to the levels shown in the table in paragraph “5.2
Regulation for LPG”.
4.2 Ventilation of rooms
The hob may be installed only in rooms with permanent ventilation, as
required by standards regulations in force. The room in which the hob is
installed must have sufficient air flow to satisfy the requirements of
normal gas combustion and of necessary air exchange in the room. The
air intakes, protected by screens, must be appropriately sized
(regulations in force) and placed so as not to be blocked in any way.
The room where the oven is installed should be suitably ventilated to
avoid overheating or excess humidity produced by cooking, and in the
case of lengthy use a window should be opened or the speed of any
ventilators should be increased.
4.3 Discharge of combustion products
Discharge of combustion products must be guaranteed by means of
hoods connected to a natural draught flue with certain efficiency, or by
means of forced aspiration.
An efficient aspiration system requires careful planning by a specialist
capable of installing it, respecting the positions and distances prescribed
by standards. After installation, the installer must issue a certificate of
conformity.
Instructions for the installer
5. ADAPTATION TO DIFFERENT TYPES OF GAS
Before performing any cleaning or maintenance work, detach the
appliance from the electrical socket.
The hob has been inspected for G20 (2H) natural gas at a pressure of
20 mbar. For functioning with other types of gas the nozzles must be
replaced and the primary air adjusted.
To replace the nozzles and regulate the burners, you have to remove the
top as described in the following paragraph.
5.1 Removing the hob
1. Remove all the knobs, the grids, the burner caps and the flame-caps;
2. remove the screws and the nuts A that secure the burner supports;
3. lift the hob from its seat;
4. replace the burner nozzles in accordance with the reference gas
chart;
5. regulate the primary air as described in paragraph “5.2 Regulation
for LPG”.
Instructions for the installer
5.2 Regulation for LPG
Loosen screw A and push support B all the way. Use a double head
wrench to remove nozzle C and assemble the suitable one, following the
instructions indicated in the reference charts, with respect to the type of
gas to use. The screwing torque of the nozzle should never exceed
3 Nm. Reposition support B C so that nozzle is covered perfectly.
Move the Venturi tube D to regulate the air flow until distance "X" is
reached indicated in the chart in paragraph "5.5 Regulation of primary air”
and then secure the tube by means of screw A. After the regulations
have been carried out, restore the seals with sealing wax or equivalent
material.
Burner
Rated
heating
capacity
(kW)
LPG – G30/G31 28/37 mbar
Nozzle
diameter
1/100 mm
By-pass
mm
1/100
Reduced
flowrate
(W)
Flowrate
g/h G30
Flowrate
g/h G31
Auxiliary (1) 33 (*)1.05 48 30 380 76 75
Semi-rapid (2) 33 (*)1.65 62 30 380 120 118
Rapid (3) 3.1 85 43 750 225 222 45 (*)
Ultra rapid (4) 3.3 87 55 1200 240 236 65 (*)
Double crown internal (5) 1.15 48 30 380 76 75 33 (*)
external (5) 3.8 92 55 1200 240 236 65 (*)
Fish pan (6) 2.9 82 43 800 211 207 45 (*)
(*) By-pass value for valveless appliances.
Instructions for the installer
5.3 Regulation for natural gas
The hob has been inspected for G20 (2H) natural gas at a pressure of
20 mbar. To allow the unit to work with this type of gas, perform the same
operations described in paragraph “5.2 Regulation for LPG”, but choose
the nozzles and regulate the primary air for natural gas, as shown in the
following table and in paragraph "5.5 Regulation of primary air”. After the
regulations have been carried out, restore the seals with sealing wax or
equivalent material.
Burner
Rated
heating
capacity
(kW)
Natural gas – G20 20 mbar
Nozzle diamete
r
1/100 mm
Reduced flowrate
(W)
Auxiliary (1) 1.05 73 380
Semi-rapid (2) 1.65 92 380
Rapid (3) 3.1 126 750
Ultra rapid (4) 3.3 130 1200
Double crown internal (5) 1.05 73 380
external (5) 3.9 140 1200
Fish pan (6) 2.9 123 800
5.4 Regulation for town gas
To allow the unit to work with this type of gas, perform the same
operations described in paragraphErrore. L'origine riferimento non è
stata trovata. Regulation for LPG”, but choose the nozzles and regulate
the primary air for town gas, as shown in the following table and in
paragraph Errore. L'origine riferimento non è stata trovata.
Regulation of primary air”.
Attention! Only units with safety valves can be used with town gas
G110.
Bruciatore
Portata
termica
nominale
(kW)
Gas città – G110 8 mbar
Diametro ugello
1/100 mm
Portata ridotta
(W)
Ausiliario (1) 1.05 132 380
Semirapido (2) 1.65 165 380
Rapido (3) 3.1 240 800
Ultra rapido (4) 3.3 250 1200
Doppia corona interna (5) 1.05 132 380
esterna (5) 3.9 290 1200
Pescera (6) 2.9 230 800
Instructions for the installer
5.5 Regulation of primary air
Referred to distance “X” in mm.
To identify the burners on your hob, refer to the drawings in point “6.3
Arrangement of burners on hob “
BURNER G20
20 mbar
G30/G31
28/37 mbar
G110
8 mbar
Auxiliary (1) 1.5 1.0 0.5
Semi-rapid (2) 1.5 1.5 0.5
Rapid (3) 1.0 1.5 1.0
Ultra rapid (4) 2.0 2.5 1.5
Double crown internal (5) 3.0 6.0 1.0
external (5) 3.0 5.010.0
Fish pan (6) 2.0 2.5 1.0
Instructions for the installer
6. FINAL OPERATIONS
Having carried out the above adjustments, reassemble the appliance
following, backwards, the instructions in paragraph “5.1 Removing the
hob”.
6.1 Regulation of minimum for natural gas
Replace the components on the burner and slide
the knobs on the gas tap pins.
Light the burner and set it at minimum position.
Remove the knob and turn the regulation screw
inside or next to the gas tap pin (depending on
the model) until you get a suitable minimum
flame.
Replace the knob and check burner flame
stability: (rapidly turning the knob from maximum
to minimum position, the flame should not go
out).
6.2 Regulation of minimum for LPG
To regulate the minimum for LPG, completely tighten (clockwise) the
screw inside or next to the gas tap pin (depending on the model).
The diameters of the by-passes for each burner are given in table “5.2
Regulation for LPG”.
Instructions for the installer
6.3 Arrangement of burners on hob
BURNERS
1 Auxiliary
2 Semi-rapid
3 Rapid
4 Ultra rapid
5 Double crown
6 Fish pan
6.4 Lubrication of gas taps
After a while, the gas tap may become hard to turn or lock. If this
happens, it has to be cleaned inside and re-greased.
This must be done by a qualified technician.


Produktspezifikationen

Marke: Smeg
Kategorie: Ofen
Modell: SV564EB-4

Brauchst du Hilfe?

Wenn Sie Hilfe mit Smeg SV564EB-4 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Ofen Smeg

Bedienungsanleitung Ofen

Neueste Bedienungsanleitung für -Kategorien-