For Sharp Carousel® Built-in Kit
Models RK49S27F or RK49S30F
S = STAINLESS
THIS KIT IS UL APPROVED TO ALLOW CERTAIN MICROWAVE
OVENS TO BE INSTALLED ABOVE ANY ELECTRIC WALL OVEN.
PLEASE SEE THE OPERATION MANUAL REGARDING APPROVED
BUILT-IN APPLICATIONS.
IMPORTANT:
This Built-in Kit is designed for and approved only for those
Sharp Microwave Ovens specifying Built-In Kit RK49S27F
or RK49S30F. Refer to operation manual for approved
models.
IMPORTANT NOTES TO THE INSTALLER
• PLEASE READ THESE INSTRUCTIONS THOROUGHLY
BEFORE BEGINNING INSTALLATION.
• Observe all governing codes, ordinances, and safety
instructions.
• Be sure to leave these instructions with the consumer.
• Be sure to DISCONNECT THE PLUG of the microwave
oven from the electrical outlet before installing the Built-in
Kit. Remove the Carousel turntable from the oven cavity.
• Because the kit includes metal parts, due caution should
be used in handling and installation to avoid the possibil-
ity of injury.
ITEM PART NAME QTY
A
FRONT FRAME
RK49S27F: FDECAB233MRK0
RK49S30F: FDECAB235MRK0
1
B
BACK FRAME
RK49S27F: FDECAB234MRK0
RK49S30F: FDECAB236MRK0 1
CEXHAUST DUCT ASSEMBLY
PDUC-B194MRP0 1
D SCREW D: XTSS740P20000 2
1
INSTALLATION INSTRUCTIONS
A B
D
F
C
E
V-cut
indicates
center of
duct
CL
ITEM PART NAME QTY
E SCREW E: XOPS740P16000 8
F
AIR DEFLECTOR
RK49S27F: PREF-B036MRP0
RK49S30F: PREF-B037MRP0
2
2
STEP 1 - CABINET OR WALL OPENING
The opening in the wall or cabinet must be within the
following dimensions:
OPENING RK49S27F RK49S30F
Height (A) 14
1/ " - 152
3/ " 4
(368.3 - 400 mm)
14
1/ " - 152
3/ " 4
(368.3 - 400 mm)
Width (B) 24
11
/ " - 25 16 5/ " 16
(627.1 - 643 mm)
24
13/ " - 26 16 3/ " 4
(630.2 - 679.5 mm)
Minimum
Depth (C) 20" (508 mm) 20" (508 mm)
Outlet should be in the shaded area as indicated in NOT
Figure 1.
A
B
4"
C
4"
FIGURE 1
NOTES
• Please allow minimum 3" wood gap between the
microwave oven cutout and the appliance cutout below
the microwave oven. See Figure 2.
3" Min.
Microwave cutout
Wall oven cutout
FIGURE 2
• If the dimension of DEPTH (C) is more than 21" (533.4
mm), the outlet location may be any area on the rear wall.
• The oor of the opening should be constructed of
plywood strong enough to support the weight of the
oven and oor load (about 100 pounds/45 kg). The oor
should be level and 90Ëš with the face of the cabinet for
proper installation and operation of the oven. Be sure to
check the local building code as it may require that the
opening be enclosed with sides, ceiling and rear partition.
The proper functioning of the oven does not require the
enclosure.
STEP 2 - EXHAUST DUCT ASSEMBLY INSTALLATION
1. Place the EXHAUST DUCT ASSEMBLY in the center of
the opening. Align the front edge of the duct with the front
of the cabinet.
2. Secure the EXHAUST DUCT ASSEMBLY with 2 SCREWS
D. See Figure 3.
Exhaust duct
assembly, align
to front edge of
cabinet
Screw D
Screw D
CL
FIGURE 3
STEP 3 - FRAME INSTALLATION
1. Place the oven adjacent to the wall or cabinet opening.
Plug the power cord into the electrical outlet.
2. Carefully guide the assembled oven into the prepared
opening. Slide the oven onto the EXHAUST DUCT
ASSEMBLY. See Figure 4. Avoid pinching the cord
between the oven and the wall. Adjust the position of
the oven so that the feet of the oven are tted into the
recesses of the EXHAUST DUCT ASSEMBLY and the
door opens properly. See Figure 5.
STANDARD INSTALLATION INSTRUCTIONS
3
FIGURE 4
Exhaust
duct
assembly
Foot
Duct recess
FIGURE 5
3. DISASSEMBLY: The FRONT FRAME and BACK FRAME
come pre-assembled with ball studs engaged in the
receivers. Separate the FRONT FRAME from the BACK
FRAME. Place the assembly facedown onto a protected
surface. At the location of the ball stud, insert a athead
screwdriver between the FRONT FRAME and the BACK
FRAME and gently pry up to disengage the ball stud from
the receiver. Repeat for each corner. See Figure 6.
FIGURE 6
STANDARD INSTALLATION INSTRUCTIONS
4. BACK FRAME INSTALLATION: Position back frame with
equal space top to bottom, side to side. Mark for 4 holes,
center punch and pre-drill the cabinet with
1/ " drill bit. 16
Secure frame with 4 SCREWS E. See Figure 7.
Equal gap top, bottom
Equal gap
side to side
Mounting holes
Mounting holes
Mounting holes
Mounting holes
Screw E
Screw E
Screw E
Screw E
FIGURE 7
5. FRONT FRAME INSTALLATION: Place the FRONT
FRAME onto the BACK FRAME and align ball studs
and receivers. Secure the FRONT FRAME to the BACK
FRAME by rmly pushing the front frame onto the
back frame, engaging the 4 snap attachments. See
Figures 8-9.
Snap
attachment
FIGURE 8
FIGURE 9


Produktspezifikationen

Marke: Sharp
Kategorie: magnetron
Modell: RK49S30F

Brauchst du Hilfe?

Wenn Sie Hilfe mit Sharp RK49S30F benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung magnetron Sharp

Bedienungsanleitung magnetron

Neueste Bedienungsanleitung für -Kategorien-