Installation and User's
Manual for Remote Condenser Modular Cuber
E Series Model C2648R
C2648 E
Remote Condenser Models - User Manual
July 2018
Page 1
Introduction
The design of this modular remote cuber is the result
of years of experience with remote ice machine
refrigeration systems. Standard features of this
product include front accessible on-off switches,
always-visible indicator lights, mechanical assist ice
harvest for extra efîš¿ciency, automatically adjusting
water purge and a control system that optimizes
system operation.
This installation and user manual is divided into
three sections: Installation, Use and Operation and
Maintenance.
The Installation section provides the trade person with
the information needed to properly install and start
up this ice system. The Use and Operation section
provides the user with the information needed to use
the machine. The Maintenance section contains the
instructions and schedules for the sanitation and
cleaning of the machine.
Contents
Installation: Product Speciîš¿cations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 2
Model Number Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 3
Product Description and Electrical Requirements . . . . . . . . . . . . . . . . . . . . . Page 4
Ice Machine Layouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 5
Water . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 6
Panel Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7
Remote Condenser Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 8
For The Installer: Remote Condenser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 9
Line Set Routing and Brazing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 10
Plumbing Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 11
Electrical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 12
Final Check List: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 13
Initial Start Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 14
Adjustments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 15
Use and Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 16
Switch Panel Area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 17
Options and Other Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 18
Cleaning, Sanitation and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 19
Remote condenser and other maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . Page 21
What to do before calling for service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 22
Note the Caution and Warning symbols when they appear on the product or in this manual. They indicate
potential hazards.
Keep this manual for future reference.
C2648 E
Remote Condenser Models - User Manual
May 2017
Page 2
Installation: Product Speciîš¿cations
Location Limitations
This ice system is made up of three parts, the ice
making machine, or head; the remote condenser; and
the interconnecting tubing. The ice making machine
must be installed indoors, in a controlled environment.
Space must be provided near the machine for service
access. The remote condenser may be installed
above or below the ice machine, per the limits stated
later in this manual. The remote condenser may
be installed outdoors within the temperature limits
listed below. The interconnecting tubing must be
installed per the directions stated in this manual,
and the amount of tubing exposed to uncontrolled
temperatures must be minimized.
Space Limitations
Although the machine will function with no clearance
to the top and sides, some space must be allowed
for service access. Building the machine in with no
access will cause higher service cost, in many cases
this extra cost may not be covered by warranty.
Environmental Limitations, ice machine:
Minimum Maximum
Air temperature 50oF. 100oF.
Water
temperature
40oF. 100oF.
Water pressure 20 psi 80 psi
Remote condenser
Minimum Maximum
Air temperature -20oF. 120oF.
Power Supply
Minimum Maximum
208-230 volt
model
198 volts 253 volts
Warranty Information
The warranty statement for this product is provided
separately from this manual. Refer to it for applicable
coverage. In general warranty covers defects
in material and workmanship. It does not cover
maintenance, corrections to installations, or situations
when the ice machine is operated in circumstances
that exceed the limitations printed above.
Product Information
The machine is a specialized version of a modular
cuber. A modular cuber does not include any ice
storage, it is designed to be placed onto an ice
storage bin. Many installations only require the
matching bin, but some may need an adapter to be
placed between the ice machine and the bin.
Additionally, the machine must be connected to the
correct remote condenser and use the correct pre-
charged tubing. The machine is supplied with a full
refrigerant charge, îš¿eld charging is not required.
This product cannot be stacked.


Produktspezifikationen

Marke: Scotsman
Kategorie: Nicht kategorisiert
Modell: C2648R-E

Brauchst du Hilfe?

Wenn Sie Hilfe mit Scotsman C2648R-E benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Nicht kategorisiert Scotsman

Bedienungsanleitung Nicht kategorisiert

Neueste Bedienungsanleitung für -Kategorien-