3-8. Mounting
(1) To install the indoor unit, mount the indoor unit
onto the 2 tabs on the upper part of the rear plate.
(2) Hold down the air discharge outlet and press the
lower part of the indoor unit until it clicks to
securely fasten to the 2 tabs on the lower part of
the rear plate. (Fig. 33)
For tubing, choose either the right or left tubing direc-
tion and follow the steps below. This work can be made
easier by placing padding material (such as styrofoam)
at the rear right side of the indoor unit. (Fig. 34a)
Or extend the support on the back of the indoor unit as
a stand to make your work easier. (Fig. 34b)
IRight-side tubing
(1) Shape the refrigerant tubing so that it can easily
go into the wall hole. (Fig. 35a or 35b)
(2) Push the wiring, refrigerant tubing, and drain hose
through the hole in the wall. Adjust the indoor unit
so it is securely seated on the rear panel. (Fig. 36)
(3) Carefully bend the tubing (if necessary) to run
along the wall in the direction of the outdoor unit
and then tape as far as the fittings. (See Caution
on page 10 or 15 in the outdoor unit installation
manual.) The drain hose should come straight
down the wall to a point where water runoff won’t
stain the wall.
(4) Connect the refrigerant tubing to the outdoor unit.
(After performing a leak test on the connecting
part, insulate it with the tubing insulation. (Fig. 37))
Also, refer to Section 3-6. Tubing connections in
the outdoor unit installation manual.
(5) Assemble the refrigerant tubing, drain hose, and
inter-unit wiring as shown in Fig. 37.
NOTE
Cover
Refrigerant
tubing
Rear panel
Drain hose
Inter-unit
wiring
Fig. 35a
Fig. 36
Fig. 33
P hus
Insulation
Paddi materialng
Fig. 34a
Rear panel
(SAP-KRV96)
(SAP-KMRV74, KMRV94, KMRV124)
(SAP-KMRV76, KMRV96, KMRV126)
(SAP-KRV184, KRV244)
(SAP-KRV186, KRV246)
Fig. 34b
Fig. 37
Wall cap
Tab
Rear pa eln
Refri era tg n
t biu ng
Inter- itun
wiring
Drai hon se
Fig. 35b
(SAP-KMRV74, KMRV94, KMRV124)
(SAP-KMRV76, KMRV96, KMRV126)
(SAP-KRV184, KRV244)
(SAP-KRV186, KRV246)
(SAP-KRV96)
17
English
Hole i walln
Be t partn
Narrow t beu
Wide t beu
Rear pa eln
Fig. 38a
Drai capn
Drai ho en s
Fig. 39a
ILeft-side tubing
(SAP-KMRV74EH, KMRV94EH, KMRV124EH,
KMRV76EH, KMRV96EH, KMRV126EH,
KRV184EH, KRV244EH, KRV186EH, KRV246EH)
(1) Lead the tubing and drain hose through the wall,
allowing sufficient length for connection. Then
bend the tubing using a tube bender to make the
attachment. (Fig. 38a)
(2) Switch the drain hose and drain cap.
Switching drain hose and drain cap
(a) Locate the drain hose and the drain cap.
(Fig. 39a)
(b) Remove the screws fastening the drain hose
on the right side, and pull out the drain hose
to remove it. (Fig. 39a)
(c) Apply moderate force to pull off the drain cap
on the left side. (If you cannot pull it off by
hand, use a long-nose pliers.)
(d) Reattach the drain hose to the left side and
the drain cap to the right side. (Fig. 40a)
Drain hose
Slide the drain hose fully onto the drain pan outlet
until the drain hose edge is pushed into the insu-
lation. Check that the screw holes in the drain
bracket and the drain pan outlet are aligned and
securely in contact, then fasten them with the
screw. (After attaching the drain hose, check that
it is attached securely.) (Fig. 40c)
Drain cap
Use a Phillips screwdriver to push the drain cap in
firmly. (If it is difficult to push in, wet the cap with
water first.)
(3) Install the indoor unit on the rear panel.
(4) Connect the tubing and wiring led inside from out-
doors.
(5) After completing a leak test, bundle the tubing
together with armoring tape and store it inside the
tubing storage area at the back of the indoor unit
and hold it with clamps. (Figs. 40a and 41a)
Fig. 40a
Fig. 40bFig. 40c
Fig. 41a
Refri era t t big n u ng
I ter- it wirin un ng
Screw
Drai ho en s
Drai pa o tletn n u
Screw hole
Drai bracketn
Drai capn
Clamp
Drai ho en s
Drai ho en s
Drai bracketn
I lationsu n
English
ILeft-side tubing
(SAP-KRV96EHDS)
(1) Lead the tubing and drain hose through the wall,
allowing sufficient length for connection. Then
bend the tubing using a tube bender to make the
attachment. (Fig. 38b)
(2) Switch the drain hose and drain cap.
Switching drain hose and drain cap
(a) Grasp the corners of the bottom left and right
indoor unit covers, and press down on the
bottom while lifting each cover up to remove
it. (Fig. 39b)
(b) Locate the drain hose and the drain cap.
(Fig. 39c)
(c) When disconnecting the drain hose, remove
the drain fitting from the stopper, then check
the position of the drain fitting on the end of
the hose, and turn the hose while pulling to
remove it. (Fig. 39d)
(d) Screw the drain hose all the way inside. Turn
the hose so that the protruding part of the
drain fitting comes below the stopper as
shown in the figure. It will be easy to insert
when water is added. (Fig. 39d)
(e) Align the tabs of the removed cover with the
grille tabs, and then lower the cover to install
it.
Drain cap
Use a Phillips screwdriver to push the drain cap in
firmly. (If it is difficult to push in, wet the cap with
water first.)
(3) Install the indoor unit on the rear panel.
(4) Connect the tubing and wiring led inside from out-
doors.
(5) After completing a leak test, bundle the tubing
together with armoring tape and store it inside the
tubing storage area at the back of the indoor unit
and hold it with clamps. (Figs. 40d and 41b)
Fig. 38b
Bottom left cover
Fig. 39b
Fig. 39d
Fig. 41b
Refri era t t big n u ng
I ter- it wirin un ng
Drai capn
Drai capn
Clamp
Drai hon se
Hole i walln
Rear pa eln
Be t partn
Wide t beu
Narrow t beu
Fig. 40d
Stopper
Drai fittin ng
Drai ho en s
Stopper Drai ho en s
Drai fittin ng
Drai capn
Drai hon se
Fig. 39c
18


Produktspezifikationen

Marke: Sanyo
Kategorie: Klimaanlage
Modell: SAP-KMRV94EH

Brauchst du Hilfe?

Wenn Sie Hilfe mit Sanyo SAP-KMRV94EH benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Klimaanlage Sanyo

Bedienungsanleitung Klimaanlage

Neueste Bedienungsanleitung für -Kategorien-