Samsung AM080BXMDGH Bedienungsanleitung
Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Samsung AM080BXMDGH (65 Seiten) in der Kategorie Airco. Dieser Bedienungsanleitung war für 9 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet
Seite 1/65
2
Contents
· Selecting solderless ring terminal .................... 36
· Connecting the power terminal ....................... 36
· Installing grounding wire ..................................... 38
Air tightness test and vacuum drying 40 ...........................
· Air Tightness ................................................................ 40
· Vacuum drying pipes and indoor units ....... 41
Charging refrigerant 42 .............................................................
· Important information regulation regarding
the refrigerant used ................................................ 42
· Charging refrigerant .............................................. 43
Pipe insulation ......................................................................... 44
· Insulating the refrigerant pipes and branch
joints ................................................................................. 44
· Selecting the refrigerant pipe insulator 44 ......
· Insulate the refrigerant pipe .............................. 45
· Insulate the distribution header ..................... 46
· Insulating the pipe located inside of the
outdoor unit ................................................................ 47
Basic segment display .......................................................... 48
Setting outdoor unit option switch and key
function .....................................................................................49
· Setting outdoor unit key function ................. 49
· Setting key operation and checking the view
mode with tact switch ....................................... 54
Things to check after completing the installation .. 57
Inspection & test operation ................................................59
· Checklist before auto trial operation ............ 59
· Auto trial operation ................................................. 60
Inspection & trial operation ................................................61
Automatic refrigerant amount detection function
..........................................................................................................62
Safety precautions ..................................................................... 3
Preparations for Installation .................................................. 6
· Outdoor unit classication ...................................... 6
· Accessories ....................................................................... 6
· Optional accessories ................................................... 7
Selecting installation location .............................................. 7
· Space requirements ................................................. 10
· Moving the outdoor unit ........................................13
Basic construction and installation of the outdoor unit
.......................................................................................................... 14
· Installation of Outdoor unit ................................. 14
Installation of Air-conditioner 17 ...........................................
· Refrigerant pipe work 17 ..............................................
· Selecting refrigerant pipe ..................................... 18
· Keeping refrigerant pipe ........................................ 21
· Temper grade and minimum thickness of the
refrigerant pipe ........................................................... 21
· Refrigerant pipe welding and safety
information .................................................................... 22
· Cutting or aring the pipes ................................. 23
· Connecting the ared pipes ............................... 24
· Pipe installation for an outdoor unit ............. 25
· Connecting the drain hose to the outdoor unit .
............................................................................................. 26
· Examples of refrigerant pipe installation .... 27
· Allowable length of the refrigerant pipe and
the installation examples ...................................... 28
· Installation of refrigerant Y-joint ....................... 30
· Installation of the distribution header .......... 32
Wiring work 33 ................................................................................
· Specication of the circuit breaker and power
cable ................................................................................. 33
· Specication of the protection tube ............... 34
· Power wiring Diagram ............................................ 35
For information on Samsung s environmental commitments and product-specic regulatory obligations, ’
e.g. REACH, visit: www.samsung.com/uk/aboutsamsung/sustainability/environment/our-commitment/
data/
3
ENGLISH
WARNING • Hazards or unsafe practices that may result in severe personal injury or death.
CAUTION • Hazards or unsafe practices that may result in minor personal injury (to installer/user) or property
damage.
SEVERE WARNING SIGNS
Consult qualied installer or dealer for installation.
When installation is done by unqualied person, problems such as water leakage, electric shock or re may occur.
Wear protective equipment (such as safety gloves, goggles, and headgear) during installation and maintenance works.
Installation/repair technicians may be injured if protective equipment is not properly equipped.
Installation work must be done properly according to this installation manual.
When installation is not done properly, it may cause water leakage, electric shock or re.
When installing the unit in a small room, take measure to keep the refrigerant concentration from exceeding allowable
safety limits in case of refrigerant leakage. Consult the dealer for precautionary measure before the installation.
When refrigerant leaks and exceed dangerous concentration level, it may cause suffocation accidents.
If any gas or impurities, except R-410A refrigerant, come into the refrigerant pipe, serious problem may occur and it may
cause injury.
Use the supplied accessories, specied components and tools for the installation.
Do not use the pipe and the installation product used for the R-22 refrigerant.
Failure to use the specied components can cause product fall down, water leakage, electrical shock, and re. (The pipe
and are components used for R-22 refrigerant must not be used)
Install the outdoor unit on a hard and even place that can support its weight.
If the place cannot support its weight, the outdoor unit may fall down and it may cause injury.
Safety precautions
Please follow the following safety information for safety of the installer and the user.
DVM S ECO air conditioner uses R-410A refrigerant.
• When using R-410A, moisture or foreign substances may affect the performance and reliability of the product.
Safety precautions must be obeyed when installing the refrigerant pipe.
• The designed maximum pressure of the system is 4.1MPa and therefore select appropriate material and thickness
according to the regulations.
• R-410A is a quasi-azeotrope of two refrigerants and it has to be charged in liquid phase when lling the refrigerant.
(If you charge vapor refrigerant, it may change the blend of the refrigerant and cause product malfunction.)
You must connect the indoor units for R-410A refrigerant. Refer to product catalog to nd out the models names
for connectable indoor units. (If you connect the indoor units that are not designed for R-410A, it cannot operated
normally.)
After completing the installation and trial operation, explain to the user how to use and maintain the product. Also,
hand over this installation manual so that it can be stored by the user.
Manufacturer is not responsible for the incidents occurred by improper installation. Installer is responsible for any
installation related claims from the user occurred by neglecting warnings and cautions stated in this manual. (Installer
will be responsible for any service charges that may occur)
Generally, system air conditioners should not be relocated after installation. But when it has to be relocated for
inevitable reasons, please contact Samsung’s qualied dealers for system air conditioners.
Produktspezifikationen
Marke: | Samsung |
Kategorie: | Airco |
Modell: | AM080BXMDGH |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Samsung AM080BXMDGH benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Airco Samsung
6 September 2024
6 September 2024
6 September 2024
6 September 2024
6 September 2024
6 September 2024
6 September 2024
6 September 2024
6 September 2024
6 September 2024
Bedienungsanleitung Airco
- Airco Infiniton
- Airco Domo
- Airco Emerio
- Airco G3 Ferrari
- Airco Tristar
- Airco Sanyo
- Airco Manta
- Airco Medion
- Airco Nedis
- Airco Panasonic
- Airco Profile
- Airco LG
- Airco Adler
- Airco Bestron
- Airco Camry
- Airco Guzzanti
- Airco Trisa
- Airco AEG
- Airco Ardes
- Airco Siemens
- Airco Electrolux
- Airco Gorenje
- Airco Klarstein
- Airco Koenic
- Airco Unold
- Airco Whirlpool
- Airco Bomann
- Airco Essentiel B
- Airco Korona
- Airco Listo
- Airco Melissa
- Airco Taurus
- Airco Vox
- Airco Mesko
- Airco Thomson
- Airco Trotec
- Airco BEKO
- Airco Blaupunkt
- Airco Eldom
- Airco Heinner
- Airco Home Electric
- Airco Hotpoint
- Airco Inventum
- Airco Primo
- Airco Sharp
- Airco Wilfa
- Airco Dometic
- Airco Aspes
- Airco Brandt
- Airco Comfee
- Airco Einhell
- Airco Daewoo
- Airco Everglades
- Airco Mitsubishi
- Airco GE
- Airco Haier
- Airco Hisense
- Airco Kelvinator
- Airco Midea
- Airco Frigidaire
- Airco Svan
- Airco Philco
- Airco Eurom
- Airco Avidsen
- Airco Arçelik
- Airco Hitachi
- Airco TCL
- Airco Toshiba
- Airco DCG
- Airco Rowenta
- Airco Sencor
- Airco DeLonghi
- Airco Element
- Airco Kalorik
- Airco Rotel
- Airco Tripp Lite
- Airco Anslut
- Airco Calor
- Airco Cecotec
- Airco Vaillant
- Airco Climadiff
- Airco Qlima
- Airco Amcor
- Airco Honeywell
- Airco Meaco
- Airco Suntec
- Airco Wood's
- Airco Zibro
- Airco Sigma
- Airco Moa
- Airco Carson
- Airco Broan
- Airco White Knight
- Airco Team
- Airco Be Cool
- Airco Saunier Duval
- Airco Truma
- Airco Orima
- Airco Dimplex
- Airco Fujitsu
- Airco Heylo
- Airco Proklima
- Airco Westinghouse
- Airco Baxi
- Airco Amana
- Airco Carrefour Home
- Airco Vivax
- Airco Profilo
- Airco Sauber
- Airco Zelmer
- Airco Meireles
- Airco Kogan
- Airco Royal Sovereign
- Airco Innoliving
- Airco Argo
- Airco HQ
- Airco Master
- Airco Sanus
- Airco Carrier
- Airco Edy
- Airco Milectric
- Airco Be Quiet!
- Airco Alpatec
- Airco Gree
- Airco Gutfels
- Airco Olimpia Splendid
- Airco TOSOT
- Airco SereneLife
- Airco Danby
- Airco APC
- Airco Ariston Thermo
- Airco Evolar
- Airco RCA
- Airco Daikin
- Airco Orbegozo
- Airco Furrion
- Airco General Electric
- Airco Ridgid
- Airco Daitsu
- Airco Defy
- Airco Edgestar
- Airco Emerson
- Airco Fairland
- Airco Firstline
- Airco Fuave
- Airco Fuji Electric
- Airco Jocel
- Airco Just Fire
- Airco Kenmore
- Airco Maxicool
- Airco MundoClima
- Airco Prem-i-air
- Airco Protector
- Airco SPT
- Airco Stirling
- Airco Tarrington House
- Airco Tronix
- Airco Argoclima
- Airco Elgin
- Airco Kunft
- Airco Becken
- Airco Rinnai
- Airco Ravanson
- Airco Godrej
- Airco Friedrich
- Airco NewAir
- Airco Klimaire
- Airco EcoFlow
- Airco Brivis
- Airco Geist
- Airco Simplicity
- Airco Equation
- Airco Daizuki
- Airco Braemar
- Airco Khind
- Airco Krone
- Airco Riffel
- Airco Bonaire
- Airco MRCOOL
- Airco Arcoaire
- Airco Companion
- Airco SEEGER
- Airco LERAN
- Airco IFB
- Airco ActronAir
- Airco Consul
- Airco HTW
- Airco B-Air
- Airco Mabe
- Airco House & Luft
- Airco DEXP
- Airco Evapcool
- Airco Kaco
- Airco Climachill
- Airco Bodin
- Airco Keystone
- Airco Electroline
- Airco Norpole
- Airco KDK
- Airco Hokkaido
- Airco Evapolar
- Airco Liebert
- Airco Céliera
- Airco AFINTEK
- Airco Avallon
- Airco Quirky
- Airco KwiKool
- Airco Senville
- Airco Aconatic
- Airco AireMax
- Airco Perfect Aire
- Airco Koldfront
Neueste Bedienungsanleitung für -Kategorien-
8 September 2024
8 September 2024
8 September 2024
7 September 2024
7 September 2024
7 September 2024
6 September 2024
6 September 2024
6 September 2024
6 September 2024