How-To:
Robin and WEBRelay
ROBIN
Tech Note
gf2
How-To: Robin and WEBRelayRobin Tech Note
Robin and WEBRelays
The Robin SmartView (SV) and Robin SIP s2 are equipped with one built-in relay, often used to
open doors and gates.
If one relay is not sufïŹcient for your needs you can use an IP-controlled external relay box. The
Robin SV and Robin SIP s2 are compatible with the WEBRelay products. The Quad-LS is equipped
with 4 relay switches and is powered by Power over Ethernet (PoE) or a separative power adapter.
This document explains how the Robin SV and SIP s2 can connect with the WEBRelay and how to
use ‘Events’ of the Robin to operate the relay switches of the WEBRelay.
gf3
How-To: Robin and WEBRelayRobin Tech Note
ConïŹguration of the WEBRelay and the Robin
The possibilities of the Robin and the WEBRelay are almost countless, but we’ll explain some of the
possibilities using the following example.
Connection example
This example shows how three Robin products can use one WEBRelay.
Relay 1
Relay 2
Relay 3
Relay 4
Ethernet with PoE
WEBRelay
IP address: 192.168.1.2
Power over Ethernet switch
IP address: 192.168.1.5 IP address: 192.168.1.6 IP address: 192.168.1.7
Robin SV
Robin SV
Robin SIP s2
1 The Robin SIP s2 with IP address 192.168.1.5 activates relay 1 of the WEBRelay when a
connection between the Robin and a telephone is established and on that telephone the
‘*1’ keys are pressed. It stays activated for the duration of 5 seconds.
2 The Robin SV with IP address 192.168.1.6 activates relay 2 of the WEBRelay every time
the unit makes a call to a telephone and deactivates when the call is disconnected.
3 The Robin SV with IP address 192.168.1.7 activates relay 3 of the WEBRelay every time
the camera in the unit detects motion. The relay stays activated for a minimum duration of
10 seconds.


Produktspezifikationen

Marke: Robin
Kategorie: Nicht kategorisiert
Modell: C01037
Produktfarbe: Mehrfarbig
Power over Ethernet (PoE): Ja
Anzahl Ethernet-LAN-AnschlĂŒsse (RJ-45): 1
StromstÀrke: 3 A
LED-Anzeigen: Ja
Anzahl an eingebauten Relais: 4