Technical information Internal unit
Supply voltage adapter: 230VAC/15VDC 1A
Working current: 170 mA + 50mA
Operating temperature: -10°C to 60°C
Max relative humidity: 85%
Total dimensions: 265(L) x 94(B) x 45(H) mm
Technical information External unit
Working current: < 300mA
Temperature for use: -20°C / +50°C
Total dimensions: 120 (L) x 41 (B) x 45 (H) mm
Technical requirements for connections
Use either the cable supplied measuring 10 metres
or own wiring measuring 0.6 - 0.8mm² with a max.
length of 25 metres.
You need a plug socket that is max. 1.5m from the
internal unit.
Required wiring without door lock: 3
Required wiring with door lock: 5
Parts
Internal unit with receiver
External unit
Protective cover for external unit
Mounting bracket internal unit
Fixing screws
Connecting cable 10 m
Safety instructions
The internal/external unit may never be cleaned
with detergents. Only clean with soap and a damp
cloth.
The power wiring may never be cut through nor
extended; this renders the guarantee invalid!
The internal unit may not be placed close to
magnetic fields such as next to a TV or thick power
cables.
Water may never be poured over the internal and
external unit. The external unit is only splashproof.
Assembly instructions
1. If there is not yet any wiring:
The position of the internal unit is determined as
follows: the height amounts to approximately 165
cm, and is max. 150 cm from a plug socket where
the adapter will be plugged in. The connecting
cable between the internal unit and external unit
must therefore come out of the wall behind the
internal unit. Provide a tube so the cable can move
freely. If possible also provide a tube with a
sufficiently large diameter (20-25mm).
Determine the position of the external unit
outside at the door. The ideal installation height
is 155 to 165 cm.
Insert the cable from the external unit to the
internal unit from outside to inside; the cable is
moulded.
Connect the wiring according to the diagram
below. We again emphasise that the power supply
wiring may not be extended or cut through: this
causes the appliance to work poorly and
invalidates the guarantee.
Cut off the cables with 2 cores without door lock.
If a door lock is to be connected, its connection
must be from the outside unit as shown on the
diagram above. The lock may consume no more
than 300 mA and must have a memory function
(the lock remains free until just before the door is
pushed open). The 2 wires are already provided in
a moulded cable (4m)
2. If there is already wiring present (max. 25m):
The wire diameter must be between 0.6 and 0.8
mm². Only 3 wires have to be connected. The
yellow video connection is not used so does not
have to be connected.
Shorten the moulded cables to the desired length
and strip the wires approximately 1cm. If an
electrical door lock is used: also strip the 2-core
cable over a length of 1cm.
The door lock is connected from the external unit
with the moulded cable with two wires. The lock
may consume no more than 300 mA and must
have a memory function (the lock remains in a free
position as long as the door is not pushed open).
Provide a recess behind the external unit in the
wall or door frames, connect the wiring using the
connecting blocks and push this into the recess. If
you cannot do this the wires must be twisted
together and insulated with insulation tape.
Use:
A. Having a normal conversation
1. Ringing on the external unit
2. Take the receiver and speak to the visitor.
Outdoor
unit
Profile Intercom EN - 2
PAC-206
3. The door lock can be operated with the key for
that purpose.
4. Replace the receiver after the conversation.
B. Changing functions
The volume can be adjusted using the slider
button. The volume has 3 different levels.
C. Calendar and thermometer function
1. Pressure the SET button for 2 seconds.
2. Then press the SET button again to select a
menu choice: calendar, year, month, day,
hour, minute, second.
3. Press the UP key to increase the value of each
option.
4. Press the C/F key to decrease the value of
each option.
5. You can also change the temperature unit from
Celsius to Fahrenheit using the C/F key. This
can only be done when you are not in the
setup menu.
Guarantee conditions
The guarantee period for the PAC-206 amounts to 2
years and commences on the date of purchase.
During this guarantee period Eltra NV will repair any
defects attributable to material or production faults.
Eltra nv may choose to either repair or replace a
defective appliance.
ELTRA NV is not obliged to repair or replace
appliances if they have become defective as a result of
damage, inappropriate use, or modifications or
adaptations made after the purchase date.
Take any defective appliance together with the original
receipt back to the shop where the appliance was sold.
Always add a note with a description of the problem.
Damage
Eltra nv can under no circumstances whatsoever be
held responsible for damage of whatever nature if the
appliance was not correctly installed according to the
specified installation instructions, nor for damage as a
result of unforeseen circumstances such as natural
disasters, lightening strike, etc. All such resulting costs
are consequently at the expense of the buyer and are
not covered by the guarantee conditions.
www.profile.eu
Eltra nv, Pachtgoedstraat 2, 9140 Temse, BELGIUM
Eltra DIYeuronet, Frontstraat 14, 5405 AM Uden,
THE NETHERLANDS
Produktspezifikationen
Marke: | Profile |
Kategorie: | Sicherung |
Modell: | PAC-206 Classic Parlofoon |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Profile PAC-206 Classic Parlofoon benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Sicherung Profile
18 April 2023
18 April 2023
18 April 2023
18 April 2023
18 April 2023
18 April 2023
18 April 2023
Bedienungsanleitung Sicherung
- Sicherung Trust
- Sicherung Cobra
- Sicherung Somfy
- Sicherung Essecca
- Sicherung Microtech
- Sicherung Muller
- Sicherung Provision ISR
- Sicherung Storage Options
Neueste Bedienungsanleitung für -Kategorien-
11 Mai 2023
11 Mai 2023
4 Mai 2023