1. Package Contents
Check the following contents of your package:
GSD-504HP User's Manual
55V Power Adapter Power Cord Rubber Feet x 4
If any of these are missing or damaged, please contact your
dealer immediately; if possible, retain the carton including the
original packing material, and use them again to repack the
product in case there is a need to return it to us for repair.
 Switching
îš„Hardware-based 10/100/1000Mbps, auto-negotiation and
auto MDI/MDI-X
îš„Flow control for full duplex operation and back pressure
for half duplex operation
îš„Integrates address look-up engine, supporting 2K absolute
MAC addresses
îš„Automatic address learning and address aging
 Hardware
îš„LED indicators for PoE ready/activity and LINK/ACT
îš„One 55V DC power jack
îš„Fanless design
3. Switch Front Panel
Figure 3-1 shows the front panel of the PoE Switch.
5PWR41 2
Uplink
3
PoE++ PoE+
PoE-in-Use
LNK ACT
10/100/1000
Legacy
Standard
Figure 3-1: Front Panel
Note
When choosing a location, please keep in mind the
environmental restrictions discussed in Chapter 8
-- Product Specifications.
Step 4: Connect your PoE Switch to network devices.
A. Connect one end of a standard network cable to
RJ45 port 5 on the front panel of the PoE Switch.
B. Connect the other end of the cable to a network
device, such as NVR, workstation or router.
Step 5: Connect your PoE Switch to PoE PD devices.
A. Connect one end of a standard network cable to
an RJ45 port (Choose from ports 1 to 4) on the
front panel of the PoE Switch.
B. Connect the other end of the cable to an 802.3af/
at/bt PD.
4 PoE IP Cameras
Power
PoE PoE PoE PoE
4-channel NVR
GSD-504UP
1000BASE-T UTP
PoE
1000BASE-T UTP with PoE
Power Line
PoE++ PoE++ PoE+ PoE+
5. Switch Rear Panel
Figure 5-1 shows the rear panel of the PoE Switch.
50-56V
Figure 5-1: Rear Panel
Power
Notice
1. The device is a power-required device, meaning
it will not work till it is powered. If your
networks should be active all the time, please
consider using UPS (Uninterrupted Power Supply)
for your device. It will prevent you from network
data loss or network downtime.
2. In some areas, installing a surge suppression
device may also help to protect your GSD-504UP
from being damaged by unregulated surge or
current to the GSD-504UP or the power adapter.
2. Product Features
 RJ45 Interface
îš„5 10/100/1000BASE-T RJ45 ports
 Power over Ethernet
îš„Complies with IEEE 802.3af/at/bt Power over Ethernet
end-span PSE
îš„2 ports for IEEE 802.3bt PDs and 2 ports for IEEE
8020.3af/at PDs
îš„Supports PoE power up to 90 watts for PoE port 1 to port
2, 30 watts for PoE port 3 to port 4
îš„Each port supports 55V DC power to PoE PD
îš„120-watt PoE budget
îš„Auto detects PD
îš„Circuit protection prevents power interference between
ports
îš„Supports PoE in Standard and Legacy mode
4. LED Indicators
îš„System
LED Color Function
PWR Orange Lights: Indicates the Switch has power.
The LED is shown on Port 5
îš„Per 10/100/1000Mbps Port
LED Color Function
LNK Green
Lights: Indicates the link through that
port is successfully established at
10/10/1000Mbps.
Blinks: Indicates that the Switch is actively
sending or receiving data over that
port.
îš„PoE-in-Use Port
LED Color Function
PWR Orange Lights: Indicates the port is providing 55V
DC in-line power.
6. DIP Switch
Standard/Legacy Mode
Standard To provide power to the PD devices that follow the
IEEE 802.3af/at/bt standard.
Legacy
To provide power to the PD devices that do not
fully follow the IEEE 802.3af/at/bt standard.
Besides, the Legacy mode supports PoH and Ultra
PoE.
7. Installing the Switch
This part describes how to install your PoE Switch and make
connections to it. Please follow the procedures:
Desktop Installation
To install the PoE Switch on desktop, simply follow the
following steps:
Step 1: Attach the rubber feet to the recessed areas on the
bottom of the PoE Switch.
Step 2: Place the PoE Switch on desktop near AC power
source for its power adapter.
Step 3: Keep enough ventilation space between the PoE
Switch and the surrounding objects.
Note
Cable Distance for Switch
The cable distance between the GSD-504UP and
PC/PD devices should not exceed 100 meters for
UTP/STP cable.
Note
Make sure the wiring is correct
Category 3/4/5 cable can be used for 10/100Mbps
operation. To reliably operate your network at
1000Mbps, you must use an unshielded twisted-
pair (UTP) Category 5/5e cable, or better data
grade cabling. While a Category 3 or 4 cable may
initially seem to work, it will soon cause data loss.
Step 6: Supply power to the PoE Switch.
A. Connect one end of the power core to the Switch.
B. Connect the power plug to a standard wall outlet.
When the PoE Switch receives power, the power LED should
remain solid orange.
- 9 -
- 10 -
- 11 -
- 12 - - 13 -
Wall-mounted installation
Step 1: Find the wall that you want the GSD-504UP to be
mounted on.
Step 2: Please refer to the picture below and screw the two
screws into the marked areas of the wall.
122
Step 3: Hang the GSD-504UP on the screws from the wall.
Step 4: Repeat step 6 for the desktop Installation of the
power supply to the GSD-504UP.
Note
Before mounting the device to the wall, please
check the location of the electrical outlet and the
length of the Ethernet cable.
Power
Requirements 55V DC, 2.8A
Surge
Protection
Dierence Mode: ±4KV;
Common mode: ±6KV
ESD Protection Contact 4KV; air 6KV
Power
Consumption Max. 136 watts, 464.05 BTU
Dimensions
(W x D x H) 168 x 93 x 32 mm
Weight 414g
Power over Ethernet
PoE Standard
IEEE 802.3at Power over Ethernet Plus/PSE
IEEE 802.3bt Power over Ethernet Plus Plus/
PSE
PoE Power
Supply Type
Port 1-2: End-span + Mid-span
Port 3-4: End-span
Power Pin
Assignment
Port 1-2: 4 pairs 1/2 (-), 3/6 (+) and
4/5 (+), 7/8 (-)
Port 3-4: 2 pairs 1/2 (-), 3/6 (+)
PoE Power
Output
Port 1-2: 90W max.;
Port 3-4: 30W max.
Total PoE
Power Budget 120 watts
8.ProductSpecications
Model
GSD-504UP
2-Port 10/100/1000T 802.3bt PoE + 2-Port
10/100/1000T 802.3at PoE + 1-Port Gigabit
Desktop Switch
Hardware Speciîš¿cations
Network
Connector
5 10/100/1000BASE-T RJ45 auto MDI/MDIX
ports
PoE Inject
Port
2 ports with 802.3bt PoE++ injector function
(Ports 1 to 2)
2 ports with 802.3af/at PoE+ injector
function (Ports 3 to 4)
LED Display
System: PWR (Orange)
Per PoE port: PoE (Orange, port 1 to port 4)
Ethernet port: LNK (Green)
Thermal Fan Fanless design
Switch
Architecture Store and Forward
MAC Address
Table
2K MAC address table with auto learning
function
Switch Fabric 10Gbps
Switch
Throughput 7.44Mpps @64 bytes
Jumbo Packet 9K bytes
Flow Control Back pressure for half duplex. IEEE 802.3x
pause frame for full duplex
Standard Conformance
EMI Safety FCC Part 15 Class A, CE
Standard
Compliance
IEEE 802.3 10BASE-T
IEEE 802.3u 100BASE-TX
IEEE 802.3ab Gigabit 1000BASE-T
IEEE 802.3x Flow Control and Back Pressure
IEEE 802.3af Power over Ethernet
IEEE 802.3at Power over Ethernet Plus
IEEE 802.3bt Power over Ethernet Plus Plus
Environment
Operating
Environment 0 ~ 50 degrees C
Storage
Environment -10 ~ 70 degrees C
Operating
Humidity 5 ~ 95%, relative humidity, non-condensing
Storage
Humidity 5 ~ 95%, relative humidity, non-condensing
9. Customer Support
Thank you for purchasing PLANET products. You can browse
our online FAQ resource on PLANET Website îš¿rst to check if it
could solve your issue. If you need more support information,
please contact PLANET support team.
PLANET online FAQs:
https://www.planet.com.tw/en/support/faq?method=category&c1=1
Support team mail address:
support@planet.com.tw
Copyright © PLANET Technology Corp. 2022
Contents are subject to revision without prior notice.
PLANET is a registered trademark of PLANET Technology Corp.
All other trademarks belong to their respective owners.
FCC Warning
This device has been tested and found to comply with
the limits for a Class A digital device, pursuant to Part 15
of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the
Instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential
area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own
expense
CE Mark Warning
This is a Class A product. In a domestic environment, this
product may cause radio interference, in which case the user
may be required to take adequate measures.
WEEE Warning
To avoid the potential eects on the environment and
human health as a result of the presence of
hazardous substances in electrical and electronic
equipment, end users of electrical and electronic
equipment should understand the meaning of the crossed-out
wheeled bin symbol. Do not dispose of WEEE as unsorted
municipal waste and have to collect such WEEE separately.
Produktspezifikationen
Marke: | Planet |
Kategorie: | Schalter |
Modell: | GSD-504UP |
Breite: | 168 mm |
Tiefe: | 93 mm |
Gewicht: | 414 g |
Produktfarbe: | Blau |
Höhe: | 32 mm |
DC input Spannung: | 55 V |
Betriebstemperatur: | 0 - 50 °C |
Relative Luftfeuchtigkeit in Betrieb: | 5 - 95 % |
Netzstandard: | IEEE 802.3, IEEE 802.3ab, IEEE 802.3af, IEEE 802.3at, IEEE 802.3bt, IEEE 802.3u, IEEE 802.3x |
Zertifizierung: | FCC Part 15 Class A, CE |
Vollduplex: | Ja |
Power over Ethernet (PoE): | Ja |
Warentarifnummer (HS): | 85176990 |
Stromverbrauch (max.): | 136 W |
LED-Anzeigen: | Ja |
Temperaturbereich bei Lagerung: | -10 - 70 °C |
Luftfeuchtigkeit bei Lagerung: | 5 - 95 % |
Switch-Typ: | Unmanaged |
Anzahl der basisschaltenden RJ-45 Ethernet Ports: | 5 |
Basic Switching RJ-45 Ethernet Ports-Typ: | Gigabit Ethernet (10/100/1000) |
Auto MDI/MDI-X: | Ja |
MAC-Adressentabelle: | 2000 Eintragungen |
Routing-/Switching-Kapazität: | 10 Gbit/s |
Durchgang: | 7.44 Mpps |
Jumbo Frames Unterstützung: | Ja |
Eingangsstrom: | 2.8 A |
Store-and-Forward: | Ja |
Jumbo-Frames: | 9000 |
Wärmeableitung: | 464.05 BTU/h |
Gesamtleistung Power over Ethernet (PoE): | 120 W |
Halb-Duplex: | Ja |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Planet GSD-504UP benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Schalter Planet
24 Juni 2024
24 Juni 2024
24 Juni 2024
24 Juni 2024
24 Juni 2024
24 Juni 2024
24 Juni 2024
24 Juni 2024
24 Juni 2024
24 Juni 2024
Bedienungsanleitung Schalter
- Schalter Asus
- Schalter Basetech
- Schalter Belkin
- Schalter Hama
- Schalter HP
- Schalter Manhattan
- Schalter Nedis
- Schalter SilverCrest
- Schalter Brennenstuhl
- Schalter Cotech
- Schalter Profile
- Schalter Quigg
- Schalter ZyXEL
- Schalter Bosch
- Schalter Buffalo
- Schalter Yamaha
- Schalter Velleman
- Schalter Powerfix
- Schalter Linksys
- Schalter Netgear
- Schalter Alecto
- Schalter Gira
- Schalter Renkforce
- Schalter Trotec
- Schalter Schneider
- Schalter Worx
- Schalter Pyle
- Schalter Kaiser
- Schalter Jabra
- Schalter One For All
- Schalter Sennheiser
- Schalter Abus
- Schalter Elro
- Schalter Perel
- Schalter Wago
- Schalter Nexa
- Schalter Tork
- Schalter GEV
- Schalter Goobay
- Schalter Lindy
- Schalter Tripp Lite
- Schalter Ansmann
- Schalter Marmitek
- Schalter Honeywell
- Schalter TRENDnet
- Schalter Globaltronics
- Schalter TP-Link
- Schalter Kathrein
- Schalter Flamingo
- Schalter Black Box
- Schalter Techly
- Schalter Theben
- Schalter GAO
- Schalter Kopp
- Schalter Hager
- Schalter Monoprice
- Schalter Monacor
- Schalter Toolcraft
- Schalter Chamberlain
- Schalter Huawei
- Schalter JUNG
- Schalter Ei Electronics
- Schalter Edimax
- Schalter Totolink
- Schalter D-Link
- Schalter QNAP
- Schalter Digitus
- Schalter DataVideo
- Schalter Lancom
- Schalter LevelOne
- Schalter APC
- Schalter Grandstream
- Schalter Grässlin
- Schalter EVE
- Schalter Comet
- Schalter Elektrobock
- Schalter Tenda
- Schalter CyberPower
- Schalter IFM
- Schalter Intertechno
- Schalter Ubiquiti Networks
- Schalter Unify
- Schalter Kramer
- Schalter Intellinet
- Schalter AV:link
- Schalter Hikvision
- Schalter Vemer
- Schalter EnGenius
- Schalter Finder
- Schalter Mikrotik
- Schalter Shimano
- Schalter Homematic IP
- Schalter Heidemann
- Schalter Berker
- Schalter Emerson
- Schalter Intermatic
- Schalter Inverto
- Schalter Mercury
- Schalter Merlin Gerin
- Schalter Paladin
- Schalter Suevia
- Schalter AMX
- Schalter Triax
- Schalter Ubiquiti
- Schalter UPM
- Schalter Adder
- Schalter Vimar
- Schalter Siig
- Schalter Iogear
- Schalter StarTech.com
- Schalter Smart-AVI
- Schalter Shelly
- Schalter Dahua Technology
- Schalter PAC
- Schalter Gefen
- Schalter Avocent
- Schalter Legrand
- Schalter Eltako
- Schalter CYP
- Schalter H-Tronic
- Schalter ATen
- Schalter Noble
- Schalter SmartAVI
- Schalter Rule
- Schalter Kraus & Naimer
- Schalter Chacon
- Schalter Phoenix Contact
- Schalter OSD Audio
- Schalter BZBGear
- Schalter Crestron
- Schalter ORNO
- Schalter Atlona
- Schalter Krone
- Schalter Lightware
- Schalter Roline
- Schalter Wallair
- Schalter Adviti
- Schalter MFA
- Schalter Matrox
- Schalter Blustream
- Schalter Vivolink
- Schalter IB Connect
- Schalter Ernitec
- Schalter Raritan
- Schalter Seuthe
- Schalter Gigahertz Solutions
- Schalter ConnectPro
- Schalter SEADA
- Schalter IPGARD
- Schalter Doepke
- Schalter Micro Connect
- Schalter Epiphan
- Schalter Baco
- Schalter Pizzato Elettrica
- Schalter Upvel
Neueste Bedienungsanleitung für -Kategorien-
20 August 2024
12 Juli 2024
11 Juli 2024
9 Juli 2024
8 Juli 2024
5 Juli 2024
4 Juli 2024
28 Juni 2024
28 Juni 2024
28 Juni 2024