Operating Instructions
Air Conditioner
4-Way Cassette (U1 type)
Ceiling (T2 type)
Model No.
INDOOR UNIT
Ceiling (T2 type) 4-Way Cassette (U1 type)
S-60PT2R5A
S-71PT2R5A
S-100PT2R5A
S-125PT2R5A
S-140PT2R5A
S-60PU1R5A
S-71PU1R5A
S-100PU1R5A
S-125PU1R5A
S-140PU1R5A
Before operating the unit, read these operating instructions thoroughly and keep them for future reference.
Panasonic Corporation
1006 Kadoma, Kadoma City, Osaka, Japan
OUTDOOR UNIT
Single Split (Single-phase)
U-60PE1R5A
U-71PE1R5A
U-100PE1R5A
U-125PE1R5A
U-140PE1R5A
Single Split (3-phase)
U-100PE1R8A
U-125PE1R8A
U-140PE1R8A
F569618
2
Conîš¿rm to authorized dealer
or specialist on usage of
speciîš¿ed refrigerant type. Using
of refrigerant other than the
speciîš¿ed type may cause product
damage, burst and injury etc.
This air conditioner has no
ventilator for intaking fresh air
from outdoors. You must open
doors or windows frequently
when you use gas or oil heating
appliances in the same room,
which consume a lot of oxygen
from the air.
Otherwise there is a risk of
suffocation in an extreme case.
Never use or store gasoline or
other ammable vapor or liquid
near the air conditioner — it is
very dangerous.
Do not use this appliance in a
potentially explosive atmosphere.
Never touch the unit with wet hands.
Do not insert your îš¿ngers or
other objects into the air
conditioner indoor or
outdoor unit, rotating parts may
cause injury.
Refrigerant gas leakage may
cause îš¿re.
For safety, be sure to turn the
air conditioner off and also to
disconnect the power before
cleaning or servicing.
Pull off the power plug from
a receptacle, or switch off
the breaker, or switch off
the power disconnecting mean to
isolate the air conditioner from the
main power supply in case of
emergency.
Do not clean inside the indoor and
outdoor units by users. Engage
authorized dealer or specialist for
cleaning.
In case of malfunction of this
appliance, do not repair by
yourself. Contact to the sales
dealer or service dealer for a
repair.
WARNING
zSafety Precautions ........................................................... 2
zPrecautions for Use ......................................................... 4
zNames of Parts ................................................................. 5
•Operation Mechanism ................................................... 5
zAdjustingAirowDirection ............................................. 6
•Adjustingairowdirectionformultiple
indoor units .................................................................... 7
zMaintenance ..................................................................... 8
•Before Requesting Services ......................................... 8
zTroubleshooting ............................................................... 9
zSpeciîš¿cations ................................................................. 10
•Indoor unit .................................................................... 10
•Outdoor unit ................................................................. 11
Contents
Thank you for purchasing this Panasonic product.
This product is a commercial
air conditioner indoor unit.
Installation Instructions attached.
Safety Precautions
Product Information
If you have problems or questions concerning your Air
Conditioner, you will need the following information. Model
and serial numbers are on the nameplate on the bottom of the
cabinet.
Model No.
Serial No.
Date of purchase
Dealer’s address
Phone number
The following symbols used in this manual, alert you to
potentially dangerous conditions to users, service personnel or
the appliance:
WARNING This symbol refers to a hazard or
unsafe practice which can result in
severe personal injury or death.
CAUTION
This symbol refers to a hazard or
unsafe practice which can result
in personal injury or product or
property damage.
Prohibited matters Matters to be
observed
• Read these Operating Instructions carefully before using this
air conditioner. If you still have any difîš¿culties or problems,
consult your dealer for help.
• This air conditioner is designed to give you comfortable
room conditions. Use this only for its intended purpose as
described in these Operating Instructions.
3
This appliance is intended to be used
by expert or trained users in shops,in
light industry and on farms, or for
commercial use by lay persons.
This appliance is not intended for
use by persons (including children)
with reduced physical, sensory
or mental capabilities, or lack of
experience and knowledge, unless
they have been given supervision
or instruction concerning use of the
appliance by a person responsible
for their safety. Children should be
supervised to ensure that do not play
with the appliance.
Keep the îš¿re alarm and the air outlet
at least 1.5m away from the unit.
Do not cool or heat the room too
much if babies or invalids are
present.
Do not turn the air conditioner on
and off from the power mains switch.
Use the ON/OFF operation button.
Do not stick anything into the air
outlet of the outdoor unit. This
is dangerous because the fan
is rotating at high speed.
Do not touch the air inlet or the
sharp aluminum îš¿ns of the
outdoor unit. You may get
injured.
Do not stick any object
into the FAN CASE. You
may be injured and the
unit may be damaged.
Provide a power outlet to be used
exclusively for each unit, and a
power supply disconnect, circuit
breaker and earth leakage breaker
for overcurrent protection should be
provided in the exclusive line.
Provide a power outlet exclusively
for each unit, and full disconnection
means having a contact separation
in all poles must be incorporated in
the îš¿xed wiring in accordance with
the wiring rules.
To prevent possible hazards
from insulation failure, the unit
must be grounded.
Do not use modiîš¿ed
cord, joint cord,
extension cord or
unspeciîš¿ed cord to
prevent overheating and îš¿re.
Stop using the product when any
abnormality/failure occurs and
disconnect the power plug or turn
off the power switch and breaker.
(Risk of smoke/îš¿re/electric shock)
Examples of abnormality/failure
• The ELCB trips frequently.
• The product sometimes does not
start when turned on.
• The power is sometimes
disconnected when the cord is
moved.
• Burnt odor or abnormal noise is
detected during operation.
• The body is deformed or
abnormally hot.
• Water leaks from the indoor unit.
• Power cord or plug becomes
abnormally hot.
• Fan speed cannot be controlled.
• The unit stops running
immediately even if it is switched
on for operation.
• The fan does not stop even if the
operation is stopped.
Contact immediately your local
dealer for maintenance/repair.
CAUTION
• The compressor may occasionally stop during thunderstorms.
This is not a mechanical failure. The unit automatically
recovers after a few minutes.
NOTICE
Important Information Regarding
The Refrigerant Used
This product contains uorinated greenhouse gases covered
by the Kyoto Protocol. Do not vent gases into the atmosphere.
Refrigerant type: R410A
GWP(1) value: 1975
(1)
GWP = global warming potential
Periodical inspections for refrigerant leaks may be required
depending on European or local legislation. Please contact
your local dealer for more information.
Do not sit or step on the unit.
You may fall down
accidentally.


Produktspezifikationen

Marke: Panasonic
Kategorie: Klimaanlage
Modell: SU-125PT2R5A

Brauchst du Hilfe?

Wenn Sie Hilfe mit Panasonic SU-125PT2R5A benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Klimaanlage Panasonic

Bedienungsanleitung Klimaanlage

Neueste Bedienungsanleitung für -Kategorien-