Panasonic CU-V12CTP5 Bedienungsanleitung

Panasonic Klimaanlage CU-V12CTP5

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Panasonic CU-V12CTP5 (104 Seiten) in der Kategorie Klimaanlage. Dieser Bedienungsanleitung war für 3 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/104
OPERATING INSTRUCTIONS
Room Air Conditioner
ENGLISH ...................... P. 1 P. 9
PORTUGUÊS ............... P. 10 P. 18
DEUTSCH ..................... P. 19 P. 27
FRANÇAIS.................... P. 28 P. 36
NEDERLANDS ............. P. 37 P. 45
ITALIANO ..................... P. 46 P. 54
GREEK ......................... P. 55 P. 63
ESPAÑOL ..................... P. 64 P. 72
RUSSIAN ...................... P. 73 P. 82
TURKISH ...................... P. 83 P. 91
dw ÆÆÆÆÆÆÆÆÆÆÆÆÆÆÆÆÆÆÆÆÆÆÆÆ π≤ π≤
π≤ π≤
π≤
±∞∞±∞∞
±∞∞±∞∞
±∞∞
Before using your air-conditioner, please read
this operating instructions carefully and keep it
for future reference.
F567398
PANASONIC HA AIR-CONDITIONING (M) SDN. BHD.
LOT 2, PERSIARAN TENGKU AMPUAN, SECTION 21,
SHAH ALAM INDUSTRIAL SITE, 40300 SHAH ALAM,
SELANGOR, MALAYSIA
HEAT-PUMP MODEL :-
(Refrigerant : R22)
Indoor Outdoor
S-A12CTP U-A12CTP5
S-A18CTP U-A18CTP5
S-A24CTP U-A24CTP5
COOLING MODEL :-
(Refrigerant : R410A)
Indoor Outdoor
CS-V12CTP CU-V12CTP5
CS-V18CTP CU-V18CTP5
CS-V24CTP CU-V24CTP5
ME67
12CTP5-cover 24/12/09, 3:46 PM1
ENGLISH
1
Thank you for purchasing our Panasonic Room Air
Conditioner.
CONTENTS
:Features ..................................................... 1
:Safety Precautions ................................... 2
Installation Precautions
Operation Precautions
:Name of Each Part ................................ 3~4
Indoor Unit
Outdoor Unit
Accessories
Remote Control
:Preparation Before Operation ................. 5
Indoor Unit
:How to Operate ..................................... 5~6
:Setting the Timer ...................................... 7
:Convenience Operation ........................... 7
Sleep Mode Operation
:Care and Maintenance ......................... 7~8
Cleaning the Indoor Unit and Remote Control
Cleaning the Air Filter
Pre-season Inspection
When the Air Conditioner is Not Used for an
Extended Period of Time
Recommended Inspection
:Helpful information ................................... 8
:Energy Saving and Operation Hints ....... 8
:Troubleshooting ....................................... 9
Normal Operation
Abnormal Operation
Call the Dealer Immediately
Note:
Before using your air conditioner, please read
this operating instructions carefully and keep it
for future reference.
FEATURES
Illuminating Button
For your convenience to operate in the dark.
(Refer page 4)
Automatic Operation
Sense indoor temperature to select the
optimum mode.
(Refer page 5)
Comfortable Airflow Operation
(Vertical Airflow Direction)
Minute airflow direction control creates a pleasant
room environment.
(Refer page 6)
ON / OFF Dual Setting Timer
To program the room air conditioner to turn itself on
and to ensure you maximum comfort when sleeping.
(Refer page 7)
Sleep Mode
Prevent the room from getting too hot or too
cold while you are sleeping.
(Refer page 7)
Auto Restart Control
Restart the unit automatically after power failure.
(Refer page 8)
Enviromental Friendly
(For Refrigerant : R410A Models)
Zero ozone depleting potential and low global warming
potential by using R410A refrigerant.
! Warning
1)
If the supply cord is damaged or needed to be replaced,
it must be replaced by the manufacturer or its service agent
or a similarly qualified person in order to avoid a hazard.
2)
Remove power plug or disconnect from the main before
servicing this appliance.
3)
Do not repair by yourself.
In case of malfunction of this appliance, do not repair by
yourself. Contact the sales dealer or service dealer for a
repair.
4)
Turn off the power (Isolation from main power supply). Pull
off the power plug from the receptacle, or switch off the
breaker, or switch off the power disconnecting mean to
isolate the equipment from the main power supply in case of
an emergency.
! Caution
DISCONNECT THE MAIN PLUG FROM THE SUPPLY
SOCKET WHEN NOT IN USE, WHERE SUPPLY
CONNECTION IS VIA MAIN PLUG.
Airborne noise.
A-weighted sound pressure level of this appliance is less than
70dB (A) under the JIS C 9612 test conditions.
Maximum cooling operation
1 m from the unit
IMPORTANT
Replacement or installation of power plugs shall be performed
by authorised/qualified personnel only.
The wires in this main lead are coloured in accordance with the
following code:
Green and Yellow : Earth
Blue : Neutral
Brown : Live
“As the colours of the wires in the main lead of this
appliance may not correspond with the coloured markings
identifying the terminals in your plug, proceed as follow:
The wire which is coloured green and yellow must be
connected to the terminal in the plug which is marked by the
letter E or by safety earth symbol ! or coloured green or green
and yellow.
The wire which is coloured blue must be connected to the
terminal which is marked with letter N or coloured black.
The wire which is coloured brown must be connected to the
terminal which is marked with letter L or coloured red.”
Please remember to record the following:
Model Number
Serial Number
Dealer’s Name
Date Purchased
Note
12CTP5-01EN(01-09) 12/24/09, 11:29 AM1
2
Installation Precautions
! Warning
Do not install, remove and reinstall the unit by
yourself.
Improper installation will cause leakage, electric
shock or fire. Please engage an authorized dealer
or specialist for the installation work.
This equipment must be earthed and installed
with ELCB.
It may cause electrical shock or fire in case
of malfunction.
OFF
OFF
Operation Precautions
! Warning
This sign warns of death or serious injury.
Do not share outlet.
Do not insert plug to operate the unit. Do not
pull out plug to stop the unit.
Do not operate with wet hands.
Do not damage or modify the power cord.
Do not insert finger or other objects into the
indoor or outdoor units.
Do not expose directly to cold air for a long period.
Plug in properly.
Use specified power cord.
If abnormal condition (burnt smell, etc.)
occurs, switch off and unplug the power
supply.
! Caution
This sign warns of injury.
Do not pull the cord to disconnect the plug.
Do not wash the unit with water.
Do not use for other purposes such as
preservation.
Do not use any combustible equipment at
airflow direction.
Do not sit or place anything on the indoor or
outdoor unit.
Switch off the power supply before cleaning.
Ventilate the room regularly.
Pay attention as to whether the installation
rack is damaged after long period of usage.
Switch off the power supply if the unit is not
used for a long period.
SAFETY PRECAUTIONS
Before operating, please read the following
“Safety Precautions” carefully.
To prevent personal injury, injury to others and
property damage, the following instructions must be
followed.
Incorrect operation due to failure to follow instructions
will cause harm or damage, the seriousness of which
is classified as follow:
! Warning
This sign warns of death or serious injury.
! Caution
This sign warns of damage to property.
The instructions to be followed are classified by the
following symbols:
This symbol (with a white background) denotes an
action that is PROHIBITED.
These symbols (with a black background) denote
actions that are COMPULSORY.
OFF
This room air conditioner must be
earthed.
Improper grounding could cause
electric shock.
Ensure that the drainage piping is
connected properly.
Otherwise, water will leak out.
Do not install the unit in a
potentially explosive atmosphere.
Gas leak near the unit could cause
fire.
! Caution
12CTP5-01EN(01-09) 12/24/09, 11:29 AM2


Produktspezifikationen

Marke: Panasonic
Kategorie: Klimaanlage
Modell: CU-V12CTP5

Brauchst du Hilfe?

Wenn Sie Hilfe mit Panasonic CU-V12CTP5 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Klimaanlage Panasonic

Bedienungsanleitung Klimaanlage

Neueste Bedienungsanleitung für -Kategorien-