Pacific Energy Summit LE Pedestal Bedienungsanleitung

Pacific Energy Heizung Summit LE Pedestal

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Pacific Energy Summit LE Pedestal (28 Seiten) in der Kategorie Heizung. Dieser Bedienungsanleitung war für 5 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/28
MODEL(s): LESUMMIT ,
SUMMIT CLASSIC LE
140223-28 SUMMIT LE / SUMMIT CLASSIC LE 10 000030 2
OPERATING AND
INSTALLATION
INSTRUCTIONS
SAFETY NOTICE
If this stove is not properly installed, a
house re may result. For your safety,
follow the installation instructions.
Contact local building or re ofcials
about restrictions and installation
inspection requirements in your area.
IMPORTANT:
THESE INSTRUCTIONS ARE TO
REMAIN WITH THE HOMEOWNER
SERIAL #
Visit www.pacificenergy.net for the most recent version of this manual
TESTED and LISTED to CAN/ULC S627
AND UL 1482
Meets the Environmental Protection
Agency's 2020 Particulate Emission
Standards (Crib Wood).
Table of Contents
Contents
Table of Contents 2 ......................................................................
Rating Label 3 ..............................................................................
Efciency and BTU Output 3 .................................................
Safety 4 ........................................................................................
Chimney Smoke and Creosote Formation 4 .........................
Chimney Fires 4 ....................................................................
To Avoid a Chimney Fire..................................................... 5
In Case of a Chimney Fire 5 ..................................................
Curing of the Paint Finish 5 ...................................................
Operation 6 ...................................................................................
Wood Selection 6 ..................................................................
DO NOT BURN : 6 .................................................................
How to Test Your Wood 6 ......................................................
Lighting a re 7 ......................................................................
Normal Operation 7 ...............................................................
Restarting After Extended or Overnight Burns 8 ..................
Proper Draft 8 ........................................................................
Ash Removal 8 ......................................................................
Ash Cleanout system (optional): 8 .......................................
Disposal of Ashes............................................................... 8
Maintenance 9 ..............................................................................
Maintenance Checks 10 ...............................................................
Weekly: 10 .............................................................................
Monthly 10 ............................................................................
When Cleaning the Chimney System: 10 ..............................
Blower: 10 .............................................................................
Bafe: 10 ...............................................................................
Bafe Removal 10 ........................................................................
Dimensions 11 ..............................................................................
Assembly 12 .................................................................................
Crate Removal 12 .................................................................
Optional Ash Cleanout System -(Install rst) 12 ...................
Pedestal Ash Pan 12 .............................................................
Leg Ash Pan 12 .....................................................................
Legs 12 ..................................................................................
Floor Protector 13 ........................................................................
Residential Installation ............................................................. 14
Clearances: 14 ......................................................................
Chimney and Connector 15 ..................................................
When using a Double-Wall Connector 15 .............................
When using a Single-Wall (smoke pipe) Connector 15 .........
Installation Procedure 16 ......................................................
Combustion Air 16 ........................................................................
Through Wall Installations 19 ...............................................
Mobile Home Installation 21 .........................................................
Clearances 21 .......................................................................
Optional Blower 22 .......................................................................
Blower Operation 22 .............................................................
Trouble Shooting 23 .....................................................................
Replacement Parts - SUMMIT LE 24 ...........................................
Replacement Parts - SUMMIT CLASSIC LE 25 ...........................
Firebricks 26 .................................................................................
Firebrick Installation 27 ................................................................
HOT GLASS WILL CAUSE
BURNS.
DO NOT UCH GLASS UNTIL TO
COOLED.
NEVER ALLOW CHILDREN TO
TOUCH GLASS.
!
WARNING
PLEASE SAVE THESE INSTRUCTIONS
This manual describes the installation and operation of the SUMMIT LE or SUMMIT CLASSIC LE Freestanding
wood heater. This heater meets the 2020 U.S. Environmental Protection Agency's crib wood emission limits for
wood heaters sold after May 15, 2015. Under specific test conditions this heater has been shown to deliver heat
at rates ranging from 13,567 to 39,159 btu/hr.
NOTE: WE STRONGLY RECOMMEND THAT SMOKE AND CARBON MONOXIDE DETECTORS BE INSTALLED IN
THE AREA WHERE THE HEATER IS TO BE INSTALLED.
If smoke detectors have been previously installed, you may notice that they are operating more frequently. This may be
due to curing of stove paint or fumes caused by accidentally leaving the re door open. Do not disconnect the detectors.
SAFETY NOTICE: If this stove is not properly installed, a house fire may result. For your safety, follow the instal-
lation instructions. Contact local building or fire officials about restrictions and installation inspection require-
ments in you area.
Please read this entire manual before you install and use your new room heater. Failure to follow instructions may result
in property damage, bodily injury, or even death.
WARNING: This product can expose you to
chemicals including ceramic bers, which are
known to the state of California to cause cancer,
and to carbon monoxide, which is known to the
state of California to cause birth defects or other
reproductive harm.
For more information, go to www.p65warnings.ca.gov.
This warning is applicable to all
PACIFIC ENERGY FIREPLACE PRODUCTS
!
SUMMIT-LE_140223
2
100000302
Rating Label
PLEASE SAVE THESE INSTRUCTIONS
This manual describes the installation and operation of
the Pacic Energy, SUMMIT LE / SUMMIT CLASSIC LE
Freestanding wood heater.
SAFETY NOTICE:
This wood heater needs periodic inspection and repair
for proper operation. It is against federal regulations to
operate this wood heater in a manner inconsistent with
the operating instructions in this manual.
EPA Certied Emissions 1.8 grams per hour
LHV Efciency 1 80%
HHV Tested Efciency 2 74%
EPA BTU Output 3 13,567 to 39,159 btu/hr
Maximum Wood Length 20 inches
Ideal Wood Length 16-18 inches
Fuel Seasoned Cord wood
1 Weighted Average Lower Heating Value (LHV) efciency as
tested using CSA B415 Performance testing of solid-fuel-
burning heating appliances. LHV assumes the moisture is
already in a vapour state so there is no loss of energy
2 Weighted Average Higher Heating Value (HHV) efciency
as tested using CSA B415 Performance testing of solid-fuel-
burning heating appliances. HHV includes the energy required
to vaporize the water in the fuel
3 The range of BTU outputs is based on efciency using CSA
B415 Performance testing of solid-fuel-burning heating appli-
ances and burn rates from the low and high EPA tests using
Douglas Fir dimensional lumber.
Efficiency and BTU Output
Experience will give you the right settings for proper combustion and efcient burning. Remember the correct air inlet
setting is affected by variables such as type of wood, outside temperature, chimney size and weather conditions. With
practice, you will become procient in operating your heater and will obtain the performance for which it was designed.
A.
16 in. / 406 mm 18 in. / 457 mm
B.
10 in. / 254 mm 10 in. / 254 mm
C.
N/A 8 in. / 203 mm
SUMMIT
D.
26 in. / 690 mm 28 in. / 693 mm
E.
15 in. / 381 mm 15 in. / 381 mm
F.
N/A 18.9 in. / 479 mm
ALDERLEA T6
D.
27.6 in. / 688 mm 29.6 in. /739 mm
E.
15.6 in. / 397 mm 15.6 in. / 397 mm
F.
N/A 19.1 in. / 486 mm
CERTIFIED FOR CANADA AND U.S.A. - MODEL / MODÈLE: SUMMIT SUMMIT CLASSIC LE ALDERLEA T6 LE LE
LISTED ROOM HEATER, SOLID FUEL TYPE. ALSO FOR USE IN MOBILE HOMES
CERTIFIED TO / CERTIFIÉ POUR: CAN/ULC S627-00 / UL 1482-2011
Refer to Intertek’s Directory of Building Products for detailed information
• INSTALL AND USE IN ACCORDANCE WITH THE MANUFACTURER’S INSTALLATION AND
OPERATING INSTRUCTIONS.
CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS, INSTALLATION PERMIT
AND INSPECTION IN YOUR AREA.
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
USE 6 INCH / 150MM DIAMETER MINIMUM 24 MSG BLACK OR LISTED CONNECTOR.
CAN BE CONNECTED TO A LINED MASONRY CHIMNEY SUITABLE FOR USE WITH SOLID FUELS.
DO NOT OBSTRUCT THE SPACE BENEATH THE HEATER.
SEE LOCAL BUILDING CODE AND MANUFACTURER'S INSTRUCTIONS FOR PRECAUTIONS
REQUIRED WHEN PASSING A CHIMNEY THROUGH A COMBUSTIBLE WALL OR CEILING.
DO NOT PASS A CHIMNEY CONNECTOR THROUGH A COMBUSTIBLE WALL OR CEILING.
MINIMUM CLEARANCE BETWEEN SINGLE WALL CHIMNEY CONNECTOR AND COMBUSTIBLE
MATERIALS-18INCHES/455MM. CLEARANCE MAY BE REDUCED BY THE USE OF LISTED PIPE
SHIELDS, WALL PROTECTORS OR OTHER MEANS APPROVED BY LOCAL BUILDING OR FIRE
OFFICIALS.
COMPONENTS REQUIRED FOR MOBILE HOME AND ALCOVE INSTALLATION: OUTSIDE AIR KIT.
BOTH CHIMNEY SYSTEM AND CONNECTOR MUST BE LISTED TO:
IN CANADA - ULC S-641 LISTED CONNECTOR
IN CANADA - ULC S-641 LISTED CONNECTOR
IN CANADA - ULC S-641 LISTED CONNECTOR
IN CANADA - ULC S-641 LISTED CONNECTOR AND ULC-S-629 LISTED CHIMNEY
AND ULC-S-629 LISTED CHIMNEY
AND ULC-S-629 LISTED CHIMNEY
AND ULC-S-629 LISTED CHIMNEY
IN CANADA - ULC S-641 LISTED CONNECTOR AND ULC-S-629 LISTED CHIMNEY
IN USA - UL-103 HT LISTED CONNECTOR
IN USA - UL-103 HT LISTED CONNECTOR
IN USA - UL-103 HT LISTED CONNECTOR
IN USA - UL-103 HT LISTED CONNECTOR AND CHIMNEY
AND CHIMNEY
AND CHIMNEY
AND CHIMNEY
IN USA - UL-103 HT LISTED CONNECTOR AND CHIMNEY
USE COMPONENTS SPECIFIED IN PACIFIC ENERGY INSTALLATION INSTRUCTIONS.
APPLIANCE MUST BE INSTALLED WITH PEDESTAL OR LEG KIT ATTACHED.
OPTIONAL COMPONENTS - FAN KIT, FAN ELECTRICAL RATING: 115V, 60HZ, 1.0 AMP.
DO NOT ROUTE POWER CORD BENEATH HEATER.
CAUTION: RISK OF EXCESSIVE TEMPERATURES - KEEP ASH DUMP CLOSED DURING FIRING OF
THE HEATER. • OPERATE ONLY WITH FEED DOOR CLOSED. OPEN TO FEED FIRE ONLY.
KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIALS WELL AWAY FROM HEATER.
REPLACE GLASS ONLY WITH CERAMIC GLASS.
HORIZONTAL CONNECTOR NOT PERMITTED IN MOBILE HOMES
* AS TESTED - PIPE SHIELD MAY BE REQUIRED BY LOCAL AUTHORITIES.
** COMBUSTIBLE ALCOVE SIZE:
DEPTH - 3 FT. / .91 M MAX., HEIGHT 7 FT. / 2.1 M MIN.,
COMBUSTIBLE FLOOR MUST BE PROTECTED BY A CONTINUOUS NON-COMBUSTIBLE MATERIAL
EXTENDED TO THE FRONT, SIDES AND BACK AS INDICATED.
• THIS WOOD HEATER NEEDS PERIODIC INSPECTION AND REPAIR FOR PROPER OPERATION. -
CONSULT THE OWNER’S MANUAL FOR FURTHER INFORMATION.
• IT IS AGAINST FEDERAL REGULATIONS TO OPERATE THIS WOOD HEATER IN A MANNER
INCONSISTANT WITH THE OPERATING INSTRUCTIONS IN THE OWNER’S MANUAL
MINIMUM CLEARANCES TO
COMBUSTIBLE MATERIALS/
DÉGAGEMENTS MINIMALES AUX
MATÉRIAUX COMBUSTIBLES
DO NOT REMOVE THIS LABEL
RESIDENTIAL INSTALLATION
USING DOUBLE WALL CONNECTOR /
INSTALLATION RÉSIDENTIELLE AVEC
DÉGAGEMENT MINIMAL, UTILISANT UN
RACCORD DE MUR DOUBLE
** ALCOVE INSTALLATION
USING DOUBLE WALL
CONNECTOR/
* INSTALLATION
EN ALCÔVE UTILISANT UN
RACCORD DE MUR DOUBLE
SN#
RESIDENTIAL INSTALLATION
USING SINGLE WALL CONNECTOR/
INSTALLATION RÉSIDENTIELLE UTILISANT
UN RACCORD DE MUR SIMPLE
IN CANADA G. 18 INCHES / 455 MM
AU CANADA
H. 8 INCHES / 200 MM
I. 8 INCHES / 200 MM
IN U.S.A. G. 16 INCHES / 405 MM
H. 5 INCHES / 127 MM
I. 0 INCHES / 0 MM
MOBILE
HOME INSTALLATION
USING DOUBLE WALL
CONNECTOR/
INSTALLATION
EN MAISON MOBILE UTILISANT
UN RACCORD DE MUR DOUBLE
C#4001507
INSTALLEZ ET UTILISEZ SELON LES INSTRUCTIONS D’INSTALLATION ET D’OPÉRATION FOURNI AVEC L’APPAREIL..
CONTACTEZ LES OFFICIELS DE LA CONSTRUCTION OU DE SERVICE D’INCENDIE POUR DES INFORMATIONS QUANT AUX
RESTRICTIONS. PERMIS D’INSTALLATION ET INSPECTIONS DANS VOTRE RÉGION.
NE RELIEZ PAS CET APPAREIL À UN CONDUIT DE CHEMINÉE DESSERVANT DÉJÀ UN AUTRE APPAREIL .
UTILISEZ UN RACCORDEMENT NOIR OU CLASSÉ DE 24 MSG ET AVEC UN DIAMÈTRE D’AU MOINS 6 POUCES / 150 mm.
PEUT ÊTRE CONNECTÉ À UNE CHEMINÉE DE MAÇONNERIE ALIGNÉE PRÊTE À L’EMPLOI AVEC DES COMBUSTIBLES
SOLIDES.
N’OBSTRUEZ PAS LESPACE SOUS LE CAISSON DU POÊLE
CONSULTEZ LE CODE LOCAL DE CONSTRUCTION ET LES INSTRUCTIONS DU FABRICANT QUANT AUX PRÉCAUTIONS À
PRENDRE LORSQUE VOUS FAITES PASSER UNE CHEMINÉE À TRAVERS D’UN MUR OU D’UN PLAFOND COMPOSÉS DE MATÉ-
RIAUX COMBUSTIBLES.
NE FAITES PAS PASSER UN RACCORDEMENT DE CHEMINÉE À TRAVERS D’UN MUR OU D’UN PLAFOND COMPOSÉS DE MATÉ-
RIAUX
DÉGAGEMENT MINIMAL ENTRE UN RACCORDEMENT DE CHEMINÉE À UN MUR SIMPLE ET TOUT MATÉRIEL COMBUSTIBLE
- 18 POUCES / 455 mm. CE DÉGAGEMENT PEUT ÊTRE RÉDUIT EN UTILISANT DES PROTECTEURS DE TUYAUX CLASSÉS,
PROTECTEURS DE MUR OU AUTRES MOYENS APPROUVÉS PAR LES OFFICIELS DE LA CONSTRUCTION OU DU SERVICE
D’INCENDIE DE VOTRE RÉGION.
CONNECTEUR HORIZONTAL NON PERMIS DANS MAISONS MOBILES
L’APPARIEL DOIT COMPORTER UN ENSEMBLE POUR PIEDSTABLE OU SUR PATTES.
PIÈCES REQUISES POUR INSTALLATION EN MAISON MOBILE OU EN ALCÔVE: NÉCESSAIRE D’APPROVI-
SIONNEMENT D’AIR EXTÉRIEUR ET L’UN DES RACCORDS SUIVANTS: EN COMBINAISON AVEC L’UN DES
SYSTÈMES DE CHEMINÉE COMPATIBLES SUIVANTS:
AU CANADA - LE ULC S-641 CONNECTEUR ENUMERES ET ULC-S-629 ONT ENUMERE CHEMINEE
PIÈCES EN OPTION - NÉCESSAIRES DE SOUFFLERIE, INDICES ÉLECTRIQUES DE SOUFFLERIE: 115V, 60HZ, 1.0 AMP. LE FIL
ÉLECTRIQUE NE DOIT PAS ÊTRE PLACÉ SOUS LE POÈTE.
LE FIL ÉLECTRIQUE NE DOIT PAS ÊTRE PLACÉ SOUS LE POÊLE
ATTENTION: RISQUE DE TEMPÉRATURES EXCESSIVES - GARDES LE TIROIR DE CENDRES FERMÉ PENDANT L’ALLUMAGE DU
POÈTE.
OPÉREZ SEULEMENT LORSQUE LA PORTE D’ALIMENTATION EST FERMÉE. • OUVREZ SEULEMENT POUR ALIMENTER LE FEU.
GARDEZ LES MEUBLES ET AUTRES MATÉRIAUX COMBUSTIBLES BIEN ÉLOIGNÉS DU POÊLE.
REMPLACES LA VITRE AVEC UNIQUEMENT DE LA VITRE CÉRAMIQUE.
*
TEL QUO ÉPROUVÉ UN PROTECTEUR DE TUYAU PEUT ÊTRE REQUIS PAR LES AUTORITÉS LOCALES
**
DIMENSION D’ALCOVE COMBUSTIBLE: PROFONDEUR - 3 PIEDS / .91M, HAUTEUR 7 PIEDS/2.1M, LARGEUR 4 PIEDS/1.2M
MINIMUM.
LE PLANCHER COMBUSTIBLE DOIT ÊTRE PROTÉGÉ PAR UN MATÉRIEL NON-COMBUSTIBLE TOUT D’UNE PIÈCE QUI DOIT
S’ÉTENDRE DE PAR LE DEVANT, LES COTÉS ET L’ARRIÈRE TEL QU’INDIQUÉ.
CET APPRAREIL DE CHAUFFAGE AU BOIS DOIT FAIRE L’OBJETD’ENTRETIENS ET D’INSPECTIONS P
É
RIODIQUES
POUR UN FONCTIONNEMENT AD
É
QUAT. CONSULTEZ LE MANUEL D’UTILISATION POUR PLUS D’INFORMATION.
A. SIDEWALL TO UNIT/
MUR DE CÔTE / APPAREIL
B. BACKWALL TO UNIT/
M
UR DE FOND / APPAREIL
C. CORNER TO UNIT/
COIN / APPAREIL
D. SIDEWALL TO CONNECTOR/
MUR DE CÔTE / RACCORD
E. BACKWALL TO CONNECTOR/
MUR DE FOND / RACCORD
F. CORNER TO CONNECTOR/
COIN / RACCORD
BACK I
HEATER
G
SIDE
H
FRONT
SIDE
H
COTE
COTE
DEVANT
POELE
DOS
MADE IN CANADA/
FABRIQUÉ AU CANADA
100001329261018
MANUFACTURED BY/
FABRIQUÉ PAR:
PACIFIC ENERGY FIREPLACE PRODUCTS LTD.
2975 ALLENBY RD., DUNCAN, BC V9L 6V8
ADJACENT WALL
BACK WALL
D
A
SIDE WALL
BE
ADJACENT WALL
F
C
MUR COTE
MUR ARRIERE
MUR ADJACENT
MUR ADJACENT
1.8 g/hr
U.S. ENVIRONMENTAL PROTECTION AGENCY.
Certifi ed to comply with 2020 CRIB WOOD PARTICULATE EMISSION
STANDARDS, using Method 28R//
Certifi é conforme aux normes sur les
émissions de particules de 2020.
DATE OF MANUFACTURE
A.
14 in. / 356 mm
B.
9 in. / 229 mm
C.
6 in. / 152 mm
SUMMIT
D.
24 in. / 610 mm
E.
*14.5 in. / 368 mm
F.
*16.9 in. / 429 mm
ALDERLEA T6
D.
25.6 in. / 650 mm
E.
*14.6 in. / 371 mm
F.
*17.1 in. / 435 mm
A.
13 in. / 330 mm
B.
7.5 in. / 191 mm
C.
5 in. / 127 mm
SUMMIT
D.
23 in. / 584 mm
E.
13 in. / 330 mm
F.
15.9 in. / 403 mm
ALDERLEA T6
D.
24.6 in. / 612 mm
E.
13.1 in. / 333 mm
F.
16.1 in. / 410 mm
Figure 1: Rating Label, SUMMIT LE .
This heater meets the 2020 U.S. Environmental Protection
Agency's crib wood emission limits for wood heaters sold
after May 15, 2020 using Method 28R.
Model SUMMIT LE / SUMMIT CLASSIC LE: 1.8 g/hr..
Under specic test conditions this heater has been shown
to deliver heat at rates ranging from 13,567 to 39,159 btu/
hr.
SAMPLE
SUMMIT-LE_140223 3100000302


Produktspezifikationen

Marke: Pacific Energy
Kategorie: Heizung
Modell: Summit LE Pedestal

Brauchst du Hilfe?

Wenn Sie Hilfe mit Pacific Energy Summit LE Pedestal benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Heizung Pacific Energy

Bedienungsanleitung Heizung

Neueste Bedienungsanleitung für -Kategorien-