Mitsubishi SRK35ZJX-S Bedienungsanleitung

Mitsubishi Klimaanlage SRK35ZJX-S

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Mitsubishi SRK35ZJX-S (222 Seiten) in der Kategorie Klimaanlage. Dieser Bedienungsanleitung war für 4 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/222
USERS MANUAL
AIR-CONDITIONER
RKY012A006A
SRK20ZJX-S
SRK25ZJX-S
SRK35ZJX-S
SRK50ZJX-S
SRK60ZJX-S
MANUEL DE L’UTILISATEUR
CLIMATISEUR
ANWENDERHANDBUCH
KLIMAGERA
¨T
ISTRUZIONI PER L’USO
CONDIZIONATORE D’ARIA
MANUAL DEL PROPIETARIO
ACONDICIONADOR DE AIRE
GEBRUIKERSHANDLEIDING
AIRCONDITIONING
MANUAL DO UTILIZADOR
APARELHO DE AR CONDICIONADO
РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ
КОНДИЦИОНЕР ВОЗДУХА
KULLANIM KILAVUZU
ENGLISH
DEUTSCH
ITALIANO
ESPAN
˜OL
NEDERLANDS
PORTUGUÊS
РУССКИЙ
TÜRKÇE
FRANÇAIS
ΟΔΗΓΙΕΣ ΧΡΗΣΗΣ
ΚΛΙΜΑΤΙΣΤΙΚΟ
ΕΛΛΗΝΙΚΑ
This air conditioner complies with Directive 2004/108/EC,EMC
LV Directive 2006/95/EC.
Ce climatiseur est conforme à la Directive 2004/108/EC, LVEMC:
Directive 2006/95/EC.
Dieses Kimagerät erfüllt die Direktiven 2004/108/EC, LVEMC
Direktiven 2006/95/EC.
Questo condizionatore d’aria è conforme alla Direttiva EMC: 2004/
108/EC, LV Direttiva 2006/95/EC.
Deze airconditioner voldoet aan Directive 2004/108/EC, LVEMC
Directive 2006/95/EC.
Este acondicionador de aire cumple con la directiva EMC: 2004/
108/EC, LV Directiva 2006/95/EC.
Este aparelho de ar condicionado está em conformidade com a
Directiva EMC 2004/108/EC e a Directiva LV 2006/95/EC.
∞˘Ùfi ÙÔ ÎÏÈÌ·ÙÈÛÙÈÎfi Â›Ó·È Û‡ÌʈÓÔ Ì ÙȘ ÚԉȷÁڷʤ˜ Ù˘
√‰ËÁ›·˜ EMC 2004/108/EK Î·È Ù˘ √‰ËÁ›·˜ LV 2006/95/EK.
–1–
Thank you for purchasing a MITSUBISHI HEAVY INDUSTRIES, LTD. Air-Conditioner. To
get the best long-lasting performance, please read and follow this User’s Manual carefully
before using your air-conditioner. After reading, please store the Manual in a safe place
and refer to it for operational questions or in the event of any irregularities.
This air-conditioner is intended for domestic use.
Do not vent R410A into the atmosphere: R410A is a fluorinated greenhouse gas,
covered by the Kyoto Protocol with a Global Warming Potential (GWP) = 1975.
contents
ENGLISH
Your Air Conditioning product may be marked with this symbol. It means
that waste electrical and electronic equipment (WEEE as in directive 2002/
96/EC) should not be mixed with general household waste. Air conditioners
should be treated at an authorized treatment facility for re-use, recycling
and recovery and not be disposed of in the municipal waste stream. Please
contact the installer or local authority for more information.
This symbol printed in the batteries attached to your Air Conditioning
product is information for end-users according to the EU directive 2006/66/
EC article 20 annex II.
Batteries, at their end-of-life, should be disposed of separately from general
household waste. If a chemical symbol is printed beneath the symbol
shown above, this chemical symbol means that the batteries contain a
heavy metal at a certain concentration. This will be indicated as follows:
Hg:mercury(0.0005%) , Cd:cadmium(0.002%) , Pb:lead(0.004%)
Please, dispose of batteries correctly at your local community waste
collection or the recycling center.
Safety precautions........................................... 2
Name of each part and its function ................. 4
Remote control handling ................................ 6
Operation failure with the remote control ...... 6
Temporary run operation ................................ 6
Operation and display section for remote
control ............................................................. 7
Current time setting ........................................ 7
AUTO mode operation ................................... 8
Temperature adjustment during AUTO.......... 8
FAN SPEED ................................................... 8
COOL/HEAT/DRY/FAN mode operation ..... 9
Air-conditioner operable
temperature setting ......................................... 9
Characteristics of HEAT mode operation ...... 9
Airflow direction adjustment ........................ 10
3D AUTO operation ..................................... 10
SLEEP TIMER operation ............................. 11
OFF-TIMER operation ................................. 11
ON-TIMER operation................................... 12
SLEEP TIMER + ON-TIMER operation ..... 12
PROGRAM TIMER operation ..................... 13
ALLERGEN CLEAR operation ................... 13
HIGH POWER/ECONOMY operation ........ 14
SELF CLEAN operation .............................. 15
Auto restart function ..................................... 15
Tips for effective operation .......................... 15
Installation location setting........................... 16
Maintenance.................................................. 17
Proper installation .........................................19
Troubleshooting ............................................ 19
Notice ........................................................... 20
Contact your dealer....................................... 21
About the Multiple Air-conditioner.............. 21
Self diagnosis function ................................. 22
–2–
Safety precautions
Before starting to use the system, please read these “Safety precautions” carefully to ensure proper operation of the system.
The safety precautions are classified as “ DANGER” and “ CAUTION”. Precautions as shown in the column DANGER” indicate that
improper handling could lead to drastic result like death, serious injury, etc. Even precautions as shown in the column CAUTION” might pose
a serious problem, depending on the circumstances. Please observe these precautions with great care, since they are essential to your safety.
Symbols which appear frequently in the text have the following meaning:
When you have read this instruction manual, please keep it without missing. If someone else takes over as operator, make certain that the manual is
also passed on to the new operator.
Strictly prohibited Provide proper earthing
Observe instructions with
great care
INSTALLATION PRECAUTIONS
OPERATION PRECAUTIONS
DANGER
Make sure that the system has been
properly earthed.
Depending on the place of installation,
an earth leakage breaker may be neces-
sary.
Do not install it where flammable gas
may leak.
Make sure to install the drain hose
properly so that all the water is
drained out.
The system is for domestic, residential
etc. use.
The system must be installed by your
dealer or a qualified professional.
If used in severer environments, such
as a n engin eering workpla ce, the
equipment may function poorly.
It is not advisable to install the system
by yourself, as faulty handling may
cause leakage of water, electric shock
or fire.
Gas leaks may cause fire. If you do not install an earth leakage
breaker, you may get an electric shock.
Improper installation may lead to
water drop in the room resulting in
wet furniture.
Earth cables should never be connected
to a gas pipe, water pipe, lightning con-
ductor or telephone earth cable. Incor-
rect installation of the earth cable may
produce an electric shock.
Do not expose yourself to the cooling
air for a long period.
Store the remote control out of reach
of infants.
Do not swing from the indoor unit.
This could affect your physical condi-
tion and cause health problems.
This may cause injury, as the inter-
nal fan rotates at high speed.
Failure to observe this may result in
the batteries being swa llowed or
other accidents.
Use of steel or copper wire instead of
an approved fuse is strictly prohib-
ited, as it may cause a breakdown or
fire.
This may cause an electric shock. If the indoor unit falls down,
you may get injured.
Do not wash the air-conditioner with wa-
ter.
You should not expose any combus-
tion appliance directly to the air
stream of the air-conditioner.
Do not place a flammable insecticide or
paint spray near the blower, nor spray it
directly on the system.
This may result in a fire. The appliance may then work inad-
equately.
This could cause an electric shock.
Do not insert anything into the air inlet.
Do not handle the switches with wet
hands.
Only use approved fuses.
CAUTION
CAUTIONDANGER
Do not place anything containing wa-
ter, like vases, on top of the unit.
The system should only be used for its original purpose
and not for anything else like, for instance, preservation of
food, plants or animals, precision devices or works of art.
Do not install the system where the
airflow direction is aimed directly at
plants or animals.
The system is only intended for use in
ordinary domestic rooms. Any other
use of the system may damage the
quality of food, etc.
Water entering the unit could dam-
age the insulation and therefore
cause an electric shock.
This will damage their health.


Produktspezifikationen

Marke: Mitsubishi
Kategorie: Klimaanlage
Modell: SRK35ZJX-S

Brauchst du Hilfe?

Wenn Sie Hilfe mit Mitsubishi SRK35ZJX-S benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Klimaanlage Mitsubishi

Bedienungsanleitung Klimaanlage

Neueste Bedienungsanleitung für -Kategorien-