SERVICE MANUAL
CONTENTS
1. TECHNICAL CHANGES ··································· 3
2. PART NAMES AND FUNCTIONS ····················· 4
3. SPECIFICATION ················································ 5
4. NOISE CRITERIA CURVES ······························ 6
5. OUTLINES AND DIMENSIONS ························ 8
6. WIRING DIAGRAM ············································ 9
7. REFRIGERANT SYSTEM DIAGRAM ··············11
8. PERFORMANCE CURVES ····························· 13
9. ACTUATOR CONTROL ··································· 27
10. SERVICE FUNCTIONS ···································· 28
11. TROUBLESHOOTING ····································· 28
12. DISASSEMBLY INSTRUCTIONS ···················· 45
Models
SPLIT-TYPE AIR CONDITIONERS
NOTE:
RoHS compliant products have <G> mark on the spec name plate.
HFC
utilized
R410A
No. OBH629
REVISED EDITION-A
OUTDOOR UNIT
Indoor unit service manual
MSZ-SF•VE Series (OBH600)
PARTS CATALOG (OBB629)
MUZ-SF25VE MUZ-SF25VEH
MUZ-SF35VE MUZ-SF35VEH
MUZ-SF42VE MUZ-SF42VEH
MUZ-SF25VE - E1 MUZ-SF42VE - E1
MUZ-SF25VE - E2 MUZ-SF42VE - E2
MUZ-SF25VEH - E1 MUZ-SF42VEH - E1
MUZ-SF35VE - E1 MUZ-SF50VE - E1
MUZ-SF35VE - E2 MUZ-SF50VEH - E1
MUZ-SF35VEH - E1
Revision A:
• MUZ-SF25/35/42VE - E2 have been added.
Please void OBH629.
2
<Preparation before the repair service>
Prepare the proper tools.
Prepare the proper protectors.
Provide adequate ventilation.
After stopping the operation of the air conditioner, turn othe power-supply breaker and remove the power plug.
Discharge the capacitor before the work involving the electric parts.
<Precautions during the repair service>
Do not perform the work involving the electric parts with wet hands.
Do not pour water into the electric parts.
Do not touch the refrigerant.
Do not touch the hot or cold areas in the refrigeration cycle.
When the repair or the inspection of the circuit needs to be done without turning off the power, exercise great caution not to
touch the live parts.
Use the speci ed refrigerant only
Never use any refrigerant other than that specified.
Doing so may cause a burst, an explosion, or fire when the unit is being used, serviced, or disposed of.
Correct refrigerant is specified in the manuals and on the spec labels provided with our products.
We will not be held responsible for mechanical failure, system malfunction, unit breakdown or accidents caused by
failure to follow the instructions.
Revision A:
• MUZ-SF25/35/42VE - E2 have been added.
OBH629A
3
MUZ-SF25VE - E1 MUZ-SF25VEH - E1
MUZ-SF35VE - E1 MUZ-SF35VEH - E1
MUZ-SF42VE - E1 MUZ-SF42VEH - E1
MUZ-SF50VE - E1 MUZ-SF50VEH - E1
1. New model
MUZ-SF25VE - E1 MUZ-SF25VE - E2
MUZ-SF35VE - E1 MUZ-SF35VE - E2
MUZ-SF42VE - E1 MUZ-SF42VE - E2
1. Condenser net has been changed. (Material: Plastic Steel wire)
TECHNICAL CHANGES