SPLIT-TYPE AIR CONDITIONERS
English
OPERATING INSTRUCTIONS For user
• To use this unit correctly and safely, be sure to read these operating
instructions before use.
MSZ-GS25VFD MSZ-GS35VFD MSZ-GS50VFD
MSZ-GS60VFD MSZ-GS71VFD MSZ-GS80VFD
INDOOR UNIT
En-1
● OPERATING INSTRUCTIONS ●
CONTENTS
SAFETY PRECAUTIONS
n SAFETY PRECAUTIONS 1
n NAME OF EACH PART 3
n PREPARATION BEFORE OPERATION 4
n SELECTING OPERATION MODES 5
n FAN SPEED AND AIRFLOW DIRECTION ADJUSTMENT 6
n ECONO COOL OPERATION 6
n TIMER OPERATION (ON/OFF TIMER) 6
n DEMAND RESPONSE AND INDOOR UNIT OPERATION 7
n EMERGENCY OPERATION 7
n AUTO RESTART FUNCTION 7
n CLEANING 8
n WHEN YOU THINK THAT TROUBLE HAS OCCURRED 9
n WHEN THE AIR CONDITIONER IS NOT GOING TO BE USED FOR A LONG TIME 10
n INSTALLATION PLACE AND ELECTRICAL WORK 10
n SPECIFICATIONS 10
WARNING
Do not connect the power cord to an intermediate point, use an
extension cord, or connect multiple devices to a single AC outlet.
• Thismaycauseoverheating,re,orelectricshock.
Make sure the power plug is free of dirt and insert it securely
into the outlet.
• Adirtyplugmaycausereorelectricshock.
Do not bundle, pull, damage, or modify the power cord, and do
not apply heat or place heavy objects on it.
• Thismaycausereorelectricshock.
Do not turn the breaker OFF/ON or disconnect/connect the power
plug during operation.
• Thismaycreatesparks,whichcancausere.
• AftertheindoorunitisswitchedOFFwiththeremotecontroller,
makesuretoturnthebreakerOFFordisconnectthepowerplug.
• Sincerotatingpartsandpartswhichcouldcauseanelectricshockareused
inthisproduct,besuretoreadthese“SafetyPrecautions”beforeuse.
• Sincethecautionaryitemsshownhereareimportantforsafety,besureto
observethem.
• Afterreadingthismanual,keepittogetherwiththeinstallationmanualina
handyplaceforeasyreference.
• Besure toreceive aguaranteecard fromyour dealerandcheck thatthe
purchaseddateandshopname,etc.areenteredcorrectly.
Marks and their meanings
WARNING : Incorrect handling could causeserious hazard, such as
death,seriousinjury,etc.withahighprobability.
CAUTION : Incorrecthandlingcouldcauseserioushazarddepending
ontheconditions.
Meanings of symbols used in this manual
: Besurenottodo.
: Besuretofollowtheinstruction.
: Neverinsertyourngerorstick,etc.
:
Neverstepontotheindoor/outdoorunitanddonotputanythingonthem.
: Dangerofelectricshock.Becareful.
: Besuretodisconnectthepowersupplyplugfromthepoweroutlet.
: Besuretoshutoffthepower.
: Riskofre.
Meanings of symbols displayed on indoor unit and/or outdoor unit
WARNING
(Riskofre)
Thisunitusesaammablerefrigerant.
Ifrefrigerantleaksandcomesincontactwithreorheatingpart,itwillcreateharmfulgasandthereisriskofre.
ReadtheOPERATINGINSTRUCTIONScarefullybeforeoperation.
ServicepersonnelarerequiredtocarefullyreadtheOPERATINGINSTRUCTIONSandINSTALLATIONMANUALbeforeoperation.
FurtherinformationisavailableintheOPERATINGINSTRUCTIONS,INSTALLATIONMANUAL,andthelike.
Do not expose your body directly to cool air for a prolonged
length of time.
• Thiscouldbedetrimentaltoyourhealth.
The unit should not be installed, relocated, disassembled,
altered, or repaired by the user.
• An improperlyhandled air conditionermay cause re,electric
shock,injury,orwaterleakage,etc.Consultyourdealer.
• Ifthepowersupplycordisdamaged,itmustbereplacedbythe
manufactureroritsserviceagentinordertoavoidahazard.
When installing, relocating, or servicing the unit, make sure that
no substance other than the specied refrigerant (R32) enters
the refrigerant circuit.
• Anypresenceofforeignsubstancesuchasaircancauseabnormal
pressureriseandmayresultinexplosionorinjury.
•
Theuseofanyrefrigerantotherthanthatspeciedforthesystemwill
causemechanicalfailure,systemmalfunction,orunitbreakdown.In
theworstcase,thiscouldleadtoaseriousimpedimenttosecuring
productsafety.
En-2
SAFETY PRECAUTIONS
WARNING
Consult your dealer for installing the air conditioner.
• It should not be installed by the user since installation requires
specializedknowledgeandskills.Animproperlyinstalledaircon-
ditionermaycausewaterleakage,re,orelectricshock.
Provide a dedicated power supply for the air conditioner.
• Anon-dedicatedpowersupplymaycauseoverheatingorre.
Do not install the unit where ammable gas could leak.
• Ifgasleaksandaccumulatesaroundtheoutdoorunit,itmaycause
anexplosion.
Earth the unit correctly.
• Donotconnecttheearthwiretoagaspipe,waterpipe,lightning
rod,oratelephoneearthwire.Improperearthingmaycauseelectric
shock.
CAUTION
Install an earth leakage breaker depending on the installation
location of the air conditioner (such as highly humid areas).
• Ifanearthleakagebreakerisnotinstalled,itmaycauseelectric
shock.
Ensure that the drain water is properly drained.
• Ifthe drain passageisimproper, water maydripdown fromthe
indoor/outdoorunit,wettinganddamagingthefurniture.
In case of an abnormal condition
Immediatelystopoperatingtheairconditionerandconsultyourdealer.
For installation
This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental capabilities,
or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance
by a person responsible for their safety.
Children should be supervised to ensure that they do not play
with the appliance.
Do not insert your nger, a stick, or other objects into the air
inlet or outlet.
• This may cause injury, since the fan inside rotates at high speeds
duringoperation.
In case of an abnormal condition (such as a burning smell),
stop the air conditioner and disconnect the power plug or turn
the breaker OFF.
• Acontinuedoperationintheabnormalstatemaycauseamalfunc-
tion,re,orelectricshock.Inthiscase,consultyourdealer.
When the air conditioner does not cool or heat, there is a pos-
sibility of refrigerant leakage. If any refrigerant leakage is found,
stop operations and ventilate the room well and consult your
dealer immediately. If a repair involves recharging the unit with
refrigerant, ask the service technician for details.
• Therefrigerantusedintheairconditionerisnotharmful.Normally,
itdoesnotleak.However,ifrefrigerantleaksandcomesincontact
withreorheatingpartofsuchafanheater,keroseneheater,or
cookingstove,itwillcreateharmfulgasandthereisriskofre.
The user should never attempt to wash the inside of the indoor
unit. Should the inside of the unit require cleaning, contact
your dealer.
• Unsuitabledetergentmaycausedamagetoplasticmaterialinside
the unit, which may result in water leakage. Should detergent
comeincontactwithelectricalpartsorthemotor,itwillresultin
amalfunction,smoke,orre.
• The appliance shall be stored in a room without continuously
operatingignitionsources(forexample:openames,anoperating
gasapplianceoranoperatingelectricheater).
• Beawarethatrefrigerantsmaynotcontainanodour.
• Donotusemeanstoacceleratethedefrostingprocessortoclean
theappliance,otherthanthoserecommendedbythemanufac-
turer.
• Donotpierceorburn.
The indoor unit must be installed in rooms which exceed the
oor space specied. Please consult your dealer.
This appliance is intended to be used by expert or trained users
in shops, in light industry and on farms, or for commercial use
by lay persons.
CAUTION
Do not touch the air inlet or the aluminum ns of the indoor/
outdoor unit.
• Thismaycauseinjury.
Do not use insecticides or ammable sprays on the unit.
• Thismaycauseareordeformationoftheunit.
Do not expose pets or houseplants to direct airow.
• Thismaycauseinjurytothepetsorplants.
Do not place other electric appliances or furniture under the
indoor/outdoor unit.
• Watermaydripdownfromtheunit,whichmaycausedamageor
malfunction.
Do not leave the unit on a damaged installation stand.
• Theunitmayfallandcauseinjury.
Do not step on an unstable bench to operate or clean the unit.
• Thismaycauseinjuryifyoufalldown.
Do not pull the power cord.
• Thismaycauseaportionofthecorewiretobreak,whichmay
causeoverheatingorre.
Do not charge or disassemble the batteries, and do not throw
them into a re.
•
Thismaycausethebatteriestoleak,orcauseareorexplosion.
Do not operate the unit for more than 4 hours at high humidity
(80% RH or more) and/or with windows or outside door left open.
• This may cause the water condensation in the air conditioner,
whichmaydripdown,wettingordamagingthefurniture.
• Thewatercondensationintheairconditionermaycontributeto
growthoffungi,suchasmold.
Do not use the unit for special purposes, such as storing food,
raising animals, growing plants, or preserving precision devices
or art objects.
• Thismaycausedeteriorationofquality,orharmtoanimalsand
plants.
Do not expose combustion appliances to direct airow.
• Thismaycauseincompletecombustion.
Never put batteries in your mouth for any reason to avoid ac-
cidental ingestion.
• Batteryingestionmaycausechokingand/orpoisoning.
Before cleaning the unit, switch it OFF and disconnect the power
plug or turn the breaker OFF.
• This may cause injury, since the fan inside rotates at high speeds
duringoperation.
When the unit will be unused for a long time, disconnect the
power plug or turn the breaker OFF.
• Theunitmayaccumulatedirt,whichmaycauseoverheatingor
re.
Replace all batteries of the remote controller with new ones of
the same type.
• Usinganoldbatterytogetherwithanewonemaycauseoverheat-
ing,leakage,orexplosion.
If the battery uid comes in contact with your skin or clothes,
wash them thoroughly with clean water.
•
If the battery uid comes in contact with your eyes, wash them
thoroughlywithcleanwaterandimmediatelyseekmedicalattention.
Ensure that the area is well-ventilated when the unit is operated
together with a combustion appliance.
• Inadequateventilationmaycauseoxygenstarvation.
Turn the breaker OFF when you hear thunder and there is a
possibility of a lightning strike.
• Theunitmaybedamagediflightningstrikes.
After the air conditioner is used for several seasons, perform
inspection and maintenance in addition to normal cleaning.
• Dirtordustintheunitmaycreateanunpleasantodor,contribute
togrowthoffungi,suchasmold,orclogthedrainpassage,and
causewatertoleakfromtheindoorunit.Consultyourdealerfor
inspectionandmaintenance,whichrequirespecializedknowledge
andskills.
Do not operate switches with wet hands.
• Thismaycauseelectricshock.
Do not clean the air conditioner with water or place an object
that contains water, such as a ower vase, on it.
• Thismaycausereorelectricshock.
Do not step on or place any object on the outdoor unit.
• Thismaycauseinjuryifyouortheobjectfallsdown.
IMPORTANT
Dirty lters cause condensation in the air conditioner which will contribute
to the growth of fungi such as mold. It is therefore recommended to clean air
lters every 2 weeks.
Produktspezifikationen
Marke: | Mitsubishi |
Kategorie: | Airco |
Modell: | MSZ-GS50VFD |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Mitsubishi MSZ-GS50VFD benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Airco Mitsubishi
4 Oktober 2024
2 Oktober 2024
30 September 2024
30 September 2024
23 September 2024
22 September 2024
22 September 2024
19 September 2024
18 September 2024
18 September 2024
Bedienungsanleitung Airco
- Airco Samsung
- Airco Infiniton
- Airco Domo
- Airco Emerio
- Airco G3 Ferrari
- Airco Tristar
- Airco Sanyo
- Airco Manta
- Airco Medion
- Airco Nedis
- Airco Panasonic
- Airco Profile
- Airco LG
- Airco Adler
- Airco Bestron
- Airco Camry
- Airco Guzzanti
- Airco Trisa
- Airco AEG
- Airco Ardes
- Airco Siemens
- Airco Bauknecht
- Airco Concept
- Airco Electrolux
- Airco Gorenje
- Airco Klarstein
- Airco Koenic
- Airco Teesa
- Airco Unold
- Airco Whirlpool
- Airco Bomann
- Airco Essentiel B
- Airco Korona
- Airco Listo
- Airco Melissa
- Airco Russell Hobbs
- Airco Taurus
- Airco Vox
- Airco Mesko
- Airco Thomson
- Airco Black And Decker
- Airco Trotec
- Airco Mestic
- Airco BEKO
- Airco Blaupunkt
- Airco Eldom
- Airco Heinner
- Airco Home Electric
- Airco Hotpoint
- Airco Inventum
- Airco Prime3
- Airco Primo
- Airco Sharp
- Airco Wilfa
- Airco Dometic
- Airco Ansonic
- Airco Aspes
- Airco Brandt
- Airco Candy
- Airco Comfee
- Airco Einhell
- Airco Daewoo
- Airco Everglades
- Airco Finlux
- Airco GE
- Airco Haier
- Airco Hisense
- Airco Kelvinator
- Airco Midea
- Airco Frigidaire
- Airco Svan
- Airco Philco
- Airco Eurom
- Airco Avidsen
- Airco Arçelik
- Airco Hitachi
- Airco Hyundai
- Airco Orava
- Airco TCL
- Airco Toshiba
- Airco DCG
- Airco Tectro
- Airco Bimar
- Airco Rowenta
- Airco Sencor
- Airco DeLonghi
- Airco Element
- Airco Kalorik
- Airco Rotel
- Airco Tripp Lite
- Airco Anslut
- Airco Calor
- Airco Cecotec
- Airco Vaillant
- Airco Climadiff
- Airco Qlima
- Airco Amcor
- Airco Honeywell
- Airco Meaco
- Airco Remko
- Airco Suntec
- Airco Wood's
- Airco Zibro
- Airco Sigma
- Airco Moa
- Airco Carson
- Airco Broan
- Airco Elba
- Airco MPM
- Airco White Knight
- Airco Team
- Airco Be Cool
- Airco Saunier Duval
- Airco Truma
- Airco Orima
- Airco Dimplex
- Airco Sonnenkönig
- Airco Fujitsu
- Airco Heylo
- Airco Toyotomi
- Airco Proklima
- Airco Westinghouse
- Airco Baxi
- Airco Amana
- Airco Carrefour Home
- Airco Vivax
- Airco Profilo
- Airco Sauber
- Airco Zelmer
- Airco Meireles
- Airco Kogan
- Airco Royal Sovereign
- Airco Innoliving
- Airco Argo
- Airco HQ
- Airco Master
- Airco Sanus
- Airco Carrier
- Airco Edy
- Airco Milectric
- Airco Be Quiet!
- Airco Insignia
- Airco Alpatec
- Airco Artrom
- Airco D-Let
- Airco Gree
- Airco Gutfels
- Airco Olimpia Splendid
- Airco TOSOT
- Airco SereneLife
- Airco Danby
- Airco APC
- Airco Ariston Thermo
- Airco Evolar
- Airco RCA
- Airco Daikin
- Airco Esatto
- Airco Orbegozo
- Airco Dantherm
- Airco Furrion
- Airco General Electric
- Airco Ridgid
- Airco Daitsu
- Airco Defy
- Airco Edgestar
- Airco Emerson
- Airco Fairland
- Airco Firstline
- Airco Fral
- Airco Fronius
- Airco Fuave
- Airco Fuji Electric
- Airco Jocel
- Airco Just Fire
- Airco Kenmore
- Airco Maiko
- Airco Maxicool
- Airco Mistral
- Airco MundoClima
- Airco Prem-i-air
- Airco Protector
- Airco SMC
- Airco SPT
- Airco Stirling
- Airco Tarrington House
- Airco Teco
- Airco Trilec
- Airco Tronix
- Airco Whynter
- Airco Argoclima
- Airco Elgin
- Airco Kunft
- Airco Becken
- Airco Rinnai
- Airco Ravanson
- Airco Godrej
- Airco Friedrich
- Airco NewAir
- Airco Klimaire
- Airco EcoFlow
- Airco Brivis
- Airco Geist
- Airco Monzana
- Airco Simplicity
- Airco Kaden
- Airco Equation
- Airco Daizuki
- Airco Braemar
- Airco Equator
- Airco Khind
- Airco Krone
- Airco American Comfort
- Airco Riffel
- Airco Bonaire
- Airco MRCOOL
- Airco Arcoaire
- Airco Companion
- Airco SEEGER
- Airco Heat Controller
- Airco LERAN
- Airco IFB
- Airco ActronAir
- Airco Consul
- Airco HTW
- Airco B-Air
- Airco Mabe
- Airco House & Luft
- Airco DEXP
- Airco Evapcool
- Airco Ocean Breeze
- Airco Commercial Cool
- Airco Kaco
- Airco InAlto
- Airco Climachill
- Airco Create
- Airco Bodin
- Airco ARCTIC WIND
- Airco JHS
- Airco Keystone
- Airco FREONIC
- Airco Big Ass Fans
- Airco Electroline
- Airco Omega Altise
- Airco TURBRO
- Airco Norpole
- Airco Kubo
- Airco KDK
- Airco Hokkaido
- Airco Evapolar
- Airco Liebert
- Airco Céliera
- Airco AFINTEK
- Airco Avallon
- Airco Columbia Vac
- Airco Vostok
- Airco Quirky
- Airco KwiKool
- Airco Senville
- Airco Goodwe
- Airco Swegon
- Airco BOSFOR
- Airco Aconatic
- Airco AireMax
- Airco VänEE
- Airco Mayer
- Airco Perfect Aire
- Airco Koldfront
Neueste Bedienungsanleitung für -Kategorien-
6 Oktober 2024
6 Oktober 2024
6 Oktober 2024
5 Oktober 2024
5 Oktober 2024
5 Oktober 2024
5 Oktober 2024
4 Oktober 2024
4 Oktober 2024
4 Oktober 2024