Mitsubishi MSZ-EF35VE3S-E1 Bedienungsanleitung

Mitsubishi Klimaanlage MSZ-EF35VE3S-E1

Lesen Sie kostenlos die ๐Ÿ“– deutsche Bedienungsanleitung fรผr Mitsubishi MSZ-EF35VE3S-E1 (46 Seiten) in der Kategorie Klimaanlage. Dieser Bedienungsanleitung war fรผr 3 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/46
Models
MSZ-EF18VEW/B/S
- E1
MSZ-EF22VEW/B/S
- E1
MSZ-EF25VEW/B/S
- E1
MSZ-EF35VEW/B/S
- E1
MSZ-EF42VEW/B/S
- E1
MSZ-EF50VEW/B/S
- E1
MSZ-EF18VE2W/B/S
- E1
MSZ-EF22VE2W/B/S
- E1
MSZ-EF25VE2W/B/S
- E1
MSZ-EF35VE2W/B/S
- E1
MSZ-EF42VE2W/B/S
- E1
MSZ-EF50VE2W/B/S
- E1
MSZ-EF18VE2W/B/S
- ER1
MSZ-EF22VE2W/B/S
- ER1
MSZ-EF25VE2W/B/S
- ER1
MSZ-EF35VE2W/B/S
- ER1
MSZ-EF42VE2W/B/S
- ER1
MSZ-EF50VE2W/B/S
- ER1
MSZ-EF18VE3W/B/S
- E1
MSZ-EF22VE3W/B/S
- E1
MSZ-EF25VE3W/B/S
- E1
MSZ-EF35VE3W/B/S
- E1
MSZ-EF42VE3W/B/S
- E1
MSZ-EF50VE3W/B/S
- E1
MSZ-EF22VE3W/B/S
- ER1
MSZ-EF25VE3W/B/S
- ER1
MSZ-EF35VE3W/B/S
- ER1
MSZ-EF42VE3W/B/S
- ER1
MSZ-EF50VE3W/B/S
- ER1
NOTE:
RoHS compliant products have <G> mark on the spec name plate.
INDOOR UNIT
SERVICE MANUAL No. OBH589
REVISED EDITION-E
PARTS CATALOG (OBB589)
MXZ-Dโˆ™VA Series (OBH626)
MXZ-8B Series (OCH480)
Outdoor unit service manual
MUZ-EFโˆ™VE(H) Series (OBH590)
MXZ-Cโˆ™VA Series (OB584)
MSZ-EF VEWโˆ™
MSZ-EF VEBโˆ™
MSZ-EF VESโˆ™
CONTENTS
1. TECHNICAL CHANGES ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท3
2. PART NAMES AND FUNCTIONS ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท5
3. SPECIFICATION ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท8
4. NOISE CRITERIA CURVES ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 10
5. OUTLINES AND DIMENSIONS ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 12
6. WIRING DIAGRAM ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 15
7. REFRIGERANT SYSTEM DIAGRAM ยทยทยทยทยทยทยทยทยทยทยท 17
8. SERVICE FUNCTIONS ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 18
9. MICROPROCESSOR CONTROL ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 20
10. TROUBLESHOOTING ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 28
11. DISASSEMBLY INSTRUCTIONS ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 42
Please void OBH589 REVISED EDITION-D.
Revision E:
โ€ข MSZ-EF18/22/25/35/42/50VE3W - E1 ,
MSZ-EF18/22/25/35/42/50VE3B - E1 ,
MSZ-EF18/22/25/35/42/50VE3S - E1 ,
MSZ-EF22/25/35/42/50VE3W - ER1 ,
MSZ-EF22/25/35/42/50VE3B - ER1 and
MSZ-EF22/25/35/42/50VE3S - ER1 have
been added.
2
<Preparation before the repair service>
Prepare the proper tools.
Prepare the proper protectors.
Provide adequate ventilation.
After stopping the operation of the air conditioner, turn off the power-supply breaker and remove the power plug.
Discharge the capacitor before the work involving the electric parts.
<Precautions during the repair service>
Do not perform the work involving the electric parts with wet hands.
Do not pour water into the electric parts.
Do not touch the refrigerant.
Do not touch the hot or cold areas in the refrigeration cycle.
When the repair or the inspection of the circuit needs to be done without turning off the power, exercise great caution not to
touch the live parts.
Use the speci๏ฌ ed refrigerant only
Never use any refrigerant other than that specified.
Doing so may cause a burst, an explosion, or fire when the unit is being used, serviced, or disposed of.
Correct refrigerant is specified in the manuals and on the spec labels provided with our products.
We will not be held responsible for mechanical failure, system malfunction, unit breakdown or accidents caused by
failure to follow the instructions.
Revision A:
โ€ข Airflow in the Silent mode in the cooling operation has been changed.
โ€ข "TROUBLESHOOTING" has been corrected (10-2, 10-4).
Revision B:
โ€ข MSZ-EF18VEW - E1 , MSZ-EF18VEB - E1 and MSZ-EF18VES - E1 have been added.
Revision C:
โ€ข MSZ-EF18/22/25/35/42/50VE2W - E1 , ER1 , MSZ-EF18/22/25/35/42/50VE2B - E1 , ER1 and MSZ-EF18/22/25/35/42/50VE2S
- E1 , ER1 have been added.
Revision D:
โ€ข The descriptions of the dimensions for MSZ-EF18/22/25/35/42/50VE2W - E1 , ER1 , MSZ-EF18/22/25/35/42/50VE2B - E1 ,
ER1 and MSZ-EF18/22/25/35/42/50VE2S - E1 , ER1 have been modified.
Revision E:
โ€ข MSZ-EF18/22/25/35/42/50VE3W -
E1
, MSZ-EF18/22/25/35/42/50VE3B -
E1
, MSZ-EF18/22/25/35/42/50VE3S -
E1
, MSZ-
EF22/25/35/42/50VE3W -
ER1
, MSZ-EF22/25/35/42/50VE3B -
ER1
and MSZ-EF22/25/35/42/50VE3S -
ER1
have been added.
OBH589E
3
TECHNICAL CHANGES
1
MSZ-EF18VEW - E1 MSZ-EF22VEW - E1 MSZ-EF25VEW - E1
MSZ-EF35VEW - E1 MSZ-EF42VEW - E1 MSZ-EF50VEW - E1
MSZ-EF18VEB - E1 MSZ-EF22VEB - E1 MSZ-EF25VEB - E1
MSZ-EF35VEB - E1 MSZ-EF42VEB - E1 MSZ-EF50VEB - E1
MSZ-EF18VES - E1 MSZ-EF22VES - E1 MSZ-EF25VES - E1
MSZ-EF35VES - E1 MSZ-EF42VES - E1 MSZ-EF50VES - E1
1. New model
MSZ-EF18VEW - E1 MSZ-EF18VE2W - E1
MSZ-EF22VEW - E1 MSZ-EF22VE2W - E1
MSZ-EF25VEW - E1 MSZ-EF25VE2W - E1
MSZ-EF35VEW - E1 MSZ-EF35VE2W - E1
MSZ-EF42VEW - E1 MSZ-EF42VE2W - E1
MSZ-EF50VEW - E1 MSZ-EF50VE2W - E1
MSZ-EF18VEB - E1 MSZ-EF18VE2B - E1
MSZ-EF22VEB - E1 MSZ-EF22VE2B - E1
MSZ-EF25VEB - E1 MSZ-EF25VE2B - E1
MSZ-EF35VEB - E1 MSZ-EF35VE2B - E1
MSZ-EF42VEB - E1 MSZ-EF42VE2B - E1
MSZ-EF50VEB - E1 MSZ-EF50VE2B - E1
MSZ-EF18VES - E1 MSZ-EF18VE2S - E1
MSZ-EF22VES - E1 MSZ-EF22VE2S - E1
MSZ-EF25VES - E1 MSZ-EF25VE2S - E1
MSZ-EF35VES - E1 MSZ-EF35VE2S - E1
MSZ-EF42VES - E1 MSZ-EF42VE2S - E1
MSZ-EF50VES - E1 MSZ-EF50VE2S - E1
1. Front panel has been changed.
2. Panel assembly has been changed.
3. Remote controller has been changed.
MSZ-EF18VE2W - ER1 MSZ-EF22VE2W - ER1 MSZ-EF25VE2W - ER1
MSZ-EF35VE2W - ER1 MSZ-EF42VE2W - ER1 MSZ-EF50VE2W - ER1
MSZ-EF18VE2B - ER1 MSZ-EF22VE2B - ER1 MSZ-EF25VE2B - ER1
MSZ-EF35VE2B - ER1 MSZ-EF42VE2B - ER1 MSZ-EF50VE2B - ER1
MSZ-EF18VE2S - ER1 MSZ-EF22VE2S - ER1 MSZ-EF25VE2S - ER1
MSZ-EF35VE2S - ER1 MSZ-EF42VE2S - ER1 MSZ-EF50VE2S - ER1
1. New model
The following models are compatible with the outdoor units with low standby power control.
Connecting the following models to the MUZ-EFยทVE(H) series outdoor units enables the low standby power control. Refer to
the technical guide (OBT17) about the low standby power control.
The following models may be connected to the MUZ-EFยทVE(H) series after once connected to the MXZ series and operated,
for example because of relocation. In that case, the MUZ-EFยทVE(H) series outdoor units will not operate without taking a step.
Follow the procedure "Deleting the memorized abnormal condition" described in 10-2.1.
OBH589E


Produktspezifikationen

Marke: Mitsubishi
Kategorie: Klimaanlage
Modell: MSZ-EF35VE3S-E1

Brauchst du Hilfe?

Wenn Sie Hilfe mit Mitsubishi MSZ-EF35VE3S-E1 benรถtigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Klimaanlage Mitsubishi

Bedienungsanleitung Klimaanlage

Neueste Bedienungsanleitung fรผr -Kategorien-