Mitsubishi MSY-GL15NA-U1 Bedienungsanleitung
Mitsubishi
Airco
MSY-GL15NA-U1
Lesen Sie kostenlos die š deutsche Bedienungsanleitung fĆ¼r Mitsubishi MSY-GL15NA-U1 (33 Seiten) in der Kategorie Airco. Dieser Bedienungsanleitung war fĆ¼r 5 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet
Seite 1/33
EspaƱol
FranƧais
English
OPERATING INSTRUCTIONS For user
ā¢ī Toīuseīthisīunitīcorrectlyīandīsafely,ībeīsureītoīreadītheseīoperatingīin-
structionsībeforeīuse.
MANUAL DE INSTRUCCIONES Paraīlosīclientes
ā¢ī Paraī utilizarī estaī unidadī deī formaī correctaī yīsegura,ī leaī previamenteī
estasīinstruccionesīdeīfuncionamiento.
NOTICE DāUTILISATION Aīlāattentionīdesīclients
ā¢ī Pourī avoirī laī certitudeī dāutiliserī cetī appareilī correctementī etī enī touteī
sĆ©curitĆ©,īveuillezīlireīcetteīnoticeīdāinstructionsīavantīdeīmettreīleīclima-
tiseurīsousītension.
SPLIT-TYPE AIR CONDITIONERS
INDOOR UNIT
MSY-GL09NA MSY-GL12NA
MSY-GL15NA
En-1
ā OPERATING INSTRUCTIONS ā
ā¢ Since rotating parts and parts which could cause an electric shock are used
in this product, be sure to read these āSafety Precautionsā before use.
ā¢ Since the cautionary items shown here are important for safety, be sure to
observe them.
ā¢ After reading this manual, keep it together with the installation manual in a
handy place for easy reference.
ā¢ Be sure to receive a guarantee card from your dealer and check that the
purchased date and shop name, etc. are entered correctly.
Marks and their meanings
WARNING : Incorrect handling could cause serious hazard, such as
death, serious injury, etc. with a high probability.
CAUTION : Incorrect handling could cause serious hazard depending
on the conditions.
Meanings of symbols used in this manual
: Be sure not to do.
: Be sure to follow the instruction.
: Never insert your ļ¬ nger or stick, etc.
:
Never step onto the indoor/outdoor unit and do not put anything on them.
: Danger of electric shock. Be careful.
: Be sure to disconnect the power supply plug from the power outlet.
: Be sure to shut off the power.
SAFETY PRECAUTIONS
CONTENTS
ā SAFETY PRECAUTIONS 1
ā NAME OF EACH PART 3
ā PREPARATION BEFORE OPERATION 4
ā SELECTING OPERATION MODES 5
ā FAN SPEED AND AIRFLOW DIRECTION ADJUSTMENT 6
ā SMART SET OPERATION 6
ā ECONO COOL OPERATION 7
ā TIMER OPERATION (ON/OFF TIMER) 7
ā CLEANING 8
ā WHEN YOU THINK THAT TROUBLE HAS OCCURRED 9
ā WHEN THE AIR CONDITIONER IS NOT GOING TO BE USED FOR A LONG TIME 10
ā INSTALLATION PLACE AND ELECTRICAL WORK 10
ā SPECIFICATIONS 10
WARNING
Do not connect the power cord to an intermediate point,
use an extension cord, or connect multiple devices to a
single AC outlet.
ā¢ This may cause overheating, ļ¬ re, or electric shock.
Make sure the power plug is free of dirt and insert it se-
curely into the outlet.
ā¢ A dirty plug may cause ļ¬ re or electric shock.
Do not bundle, pull, or modify the power cord, and do not
apply heat or place heavy objects on it.
ā¢ This may cause ļ¬ re or electric shock.
Do not turn the breaker OFF/ON or disconnect/connect the
power plug during operation.
ā¢ This may create sparks, which can cause ļ¬ re.
ā¢ After the indoor unit is switched OFF with the remote con-
troller, make sure to turn the breaker OFF or disconnect the
power plug.
Do not expose your body directly to cool air for a prolonged
length of time.
ā¢ This could be detrimental to your health.
The unit should not be installed, relocated, disassembled,
altered, or repaired by the user.
ā¢ An improperly handled air conditioner may cause ļ¬ re, electric
shock, injury, or water leakage, etc. Consult your dealer.
ā¢ If the power supply cord is damaged, it must be replaced
by the manufacturer or its service agent in order to avoid a
hazard.
When installing, relocating, or servicing the unit, make
sure that no substance other than the speciļ¬ ed refrigerant
(R410A) enters the refrigerant circuit.
ā¢ Any presence of foreign substance such as air can cause
abnormal pressure rise and may result in explosion or injury.
ā¢ The use of any refrigerant other than that speciļ¬ ed for the
system will cause mechanical failure, system malfunction,
or unit breakdown. In the worst case, this could lead to a
serious impediment to securing product safety.
This appliance is not intended for use by persons (includ-
ing children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concern-
ing use of the appliance by a person responsible for their
safety.
Children should be supervised to ensure that they do not
play with the appliance.
Do not insert your ļ¬ nger, a stick, or other objects into the
air inlet or outlet.
ā¢ This may cause injury, since the fan inside rotates at high
speeds during operation.
In case of an abnormal condition (such as a burning smell),
stop the air conditioner and disconnect the power plug or
turn the breaker OFF.
ā¢ A continued operation in the abnormal state may cause a
malfunction, ļ¬ re, or electric shock. In this case, consult your
dealer.
When the air conditioner does not cool or heat, there is
a possibility of refrigerant leakage. In this case, consult
your dealer. If a repair involves recharging the unit with
refrigerant, ask the service technician for details.
ā¢ The refrigerant used in the air conditioner is safe. Normally,
it does not leak. However, if refrigerant leaks and comes in
contact with a heat source such as a fan heater, kerosene
heater, or cooking stove, it will create a harmful gas.
The user should never attempt to wash the inside of the
indoor unit. Should the inside of the unit require cleaning,
contact your dealer.
ā¢ Unsuitable detergent may cause damage to plastic material
inside the unit, which may result in water leakage. Should
detergent come in contact with electrical parts or the motor,
it will result in a malfunction, smoke, or ļ¬ re.
En-2
SAFETY PRECAUTIONS
CAUTION
Do not touch the air inlet or the aluminum ļ¬ ns of the in-
door/outdoor unit.
ā¢ This may cause injury.
Do not use insecticides or ļ¬ ammable sprays on the unit.
ā¢ This may cause a ļ¬ re or deformation of the unit.
Do not expose pets or houseplants to direct airļ¬ ow.
ā¢ This may cause injury to the pets or plants.
Do not place other electric appliances or furniture under the
indoor/outdoor unit.
ā¢ Water may drip down from the unit, which may cause damage
or malfunction.
Do not leave the unit on a damaged installation stand.
ā¢ The unit may fall and cause injury.
Do not step on an unstable bench to operate or clean the
unit.
ā¢ This may cause injury if you fall down.
Do not pull the power cord.
ā¢ This may cause a portion of the core wire to break, which may
cause overheating or ļ¬ re.
Do not charge or disassemble the batteries, and do not
throw them into a ļ¬ re.
ā¢ This may cause the batteries to leak, or cause a ļ¬ re or explo-
sion.
Do not operate the unit for more than 4 hours at high hu-
midity (80% RH or more) and/or with windows or outside
door left open.
ā¢ This may cause the water condensation in the air conditioner,
which may drip down, wetting or damaging the furniture.
ā¢ The water condensation in the air conditioner may contribute
to growth of fungi, such as mold.
Do not use the unit for special purposes, such as storing
food, raising animals, growing plants, or preserving preci-
sion devices or art objects.
ā¢ This may cause deterioration of quality, or harm to animals
and plants.
Do not expose combustion appliances to direct airļ¬ ow.
ā¢ This may cause incomplete combustion.
Never put batteries in your mouth for any reason to avoid
accidental ingestion.
ā¢ Battery ingestion may cause choking and/or poisoning.
Before cleaning the unit, switch it OFF and disconnect the
power plug or turn the breaker OFF.
ā¢ This may cause injury, since the fan inside rotates at high
speeds during operation.
When the unit will be unused for a long time, disconnect the
power plug or turn the breaker OFF.
ā¢ The unit may accumulate dirt, which may cause overheating
or ļ¬ re.
Replace all batteries of the remote controller with new ones
of the same type.
ā¢ Using an old battery together with a new one may cause
overheating, leakage, or explosion.
If the battery ļ¬ uid comes in contact with your skin or clothes,
wash them thoroughly with clean water.
ā¢ If the battery ļ¬ uid comes in contact with your eyes, wash them
thoroughly with clean water and immediately seek medical
attention.
Ensure that the area is well-ventilated when the unit is oper-
ated together with a combustion appliance.
ā¢ Inadequate ventilation may cause oxygen starvation.
Turn the breaker OFF when you hear thunder and there is a
possibility of a lightning strike.
ā¢ The unit may be damaged if lightning strikes.
After the air conditioner is used for several seasons, per-
form inspection and maintenance in addition to normal
cleaning.
ā¢ Dirt or dust in the unit may create an unpleasant odor, con-
tribute to growth of fungi, such as mold, or clog the drain pas-
sage, and cause water to leak from the indoor unit. Consult
your dealer for inspection and maintenance, which require
specialized knowledge and skills.
Do not operate switches with wet hands.
ā¢ This may cause electric shock.
Do not clean the air conditioner with water or place an object
that contains water, such as a ļ¬ ower vase, on it.
ā¢ This may cause ļ¬ re or electric shock.
Do not step on or place any object on the outdoor unit.
ā¢ This may cause injury if you or the object falls down.
For installation
WARNING
Consult your dealer for installing the air conditioner.
ā¢ It should not be installed by the user since installation requires
specialized knowledge and skills. An improperly installed air
conditioner may cause water leakage, ļ¬ re, or electric shock.
Provide a dedicated power supply for the air conditioner.
ā¢ A non-dedicated power supply may cause overheating or ļ¬ re.
Do not install the unit where ļ¬ ammable gas could leak.
ā¢ If gas leaks and accumulates around the unit, it may cause an
explosion.
Ground the unit correctly.
ā¢ Do not connect the ground wire to a gas pipe, water pipe,
lightning rod, or a telephone ground wire. Improper grounding
may cause electric shock.
CAUTION
Install a Ground Fault Interrupt (GFI) circuit breaker depend-
ing on the installation location of the air conditioner (such
as highly humid areas).
ā¢ If the Ground Fault Interrupt (GFI) breaker is not installed, it
may cause electric shock.
Ensure that the drain water is properly drained.
ā¢ If the drain passage is improper, water may drip down from
the indoor/outdoor unit, wetting and damaging the furniture.
In case of an abnormal condition
Immediately stop operating the air conditioner and consult your dealer.
IMPORTANT
Dirty ļ¬ lters cause condensation in the air conditioner which will con-
tribute to the growth of fungi such as mold. It is therefore recommended
to clean air ļ¬ lters every 2 weeks.
Produktspezifikationen
Marke: | Mitsubishi |
Kategorie: | Airco |
Modell: | MSY-GL15NA-U1 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Mitsubishi MSY-GL15NA-U1 benƶtigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Airco Mitsubishi
4 Oktober 2024
2 Oktober 2024
30 September 2024
30 September 2024
23 September 2024
22 September 2024
22 September 2024
19 September 2024
18 September 2024
18 September 2024
Bedienungsanleitung Airco
- Airco Samsung
- Airco Infiniton
- Airco Domo
- Airco Emerio
- Airco G3 Ferrari
- Airco Tristar
- Airco Sanyo
- Airco Manta
- Airco Medion
- Airco Nedis
- Airco Panasonic
- Airco Profile
- Airco LG
- Airco Adler
- Airco Bestron
- Airco Camry
- Airco Guzzanti
- Airco Trisa
- Airco AEG
- Airco Ardes
- Airco Siemens
- Airco Bauknecht
- Airco Concept
- Airco Electrolux
- Airco Gorenje
- Airco Klarstein
- Airco Koenic
- Airco Teesa
- Airco Unold
- Airco Whirlpool
- Airco Bomann
- Airco Essentiel B
- Airco Korona
- Airco Listo
- Airco Melissa
- Airco Russell Hobbs
- Airco Taurus
- Airco Vox
- Airco Mesko
- Airco Thomson
- Airco Black And Decker
- Airco Trotec
- Airco Mestic
- Airco BEKO
- Airco Blaupunkt
- Airco Eldom
- Airco Heinner
- Airco Home Electric
- Airco Hotpoint
- Airco Inventum
- Airco Prime3
- Airco Primo
- Airco Sharp
- Airco Wilfa
- Airco Dometic
- Airco Ansonic
- Airco Aspes
- Airco Brandt
- Airco Candy
- Airco Comfee
- Airco Einhell
- Airco Daewoo
- Airco Everglades
- Airco Finlux
- Airco GE
- Airco Haier
- Airco Hisense
- Airco Kelvinator
- Airco Midea
- Airco Frigidaire
- Airco Svan
- Airco Philco
- Airco Eurom
- Airco Avidsen
- Airco ArƧelik
- Airco Hitachi
- Airco Hyundai
- Airco Orava
- Airco TCL
- Airco Toshiba
- Airco DCG
- Airco Tectro
- Airco Bimar
- Airco Rowenta
- Airco Sencor
- Airco DeLonghi
- Airco Element
- Airco Kalorik
- Airco Rotel
- Airco Tripp Lite
- Airco Anslut
- Airco Calor
- Airco Cecotec
- Airco Vaillant
- Airco Climadiff
- Airco Qlima
- Airco Amcor
- Airco Honeywell
- Airco Meaco
- Airco Remko
- Airco Suntec
- Airco Wood's
- Airco Zibro
- Airco Sigma
- Airco Moa
- Airco Carson
- Airco Broan
- Airco Elba
- Airco MPM
- Airco White Knight
- Airco Team
- Airco Be Cool
- Airco Saunier Duval
- Airco Truma
- Airco Orima
- Airco Dimplex
- Airco Sonnenkƶnig
- Airco Fujitsu
- Airco Heylo
- Airco Toyotomi
- Airco Proklima
- Airco Westinghouse
- Airco Baxi
- Airco Amana
- Airco Carrefour Home
- Airco Vivax
- Airco Profilo
- Airco Sauber
- Airco Zelmer
- Airco Meireles
- Airco Kogan
- Airco Royal Sovereign
- Airco Innoliving
- Airco Argo
- Airco HQ
- Airco Master
- Airco Sanus
- Airco Carrier
- Airco Edy
- Airco Milectric
- Airco Be Quiet!
- Airco Insignia
- Airco Alpatec
- Airco Artrom
- Airco D-Let
- Airco Gree
- Airco Gutfels
- Airco Olimpia Splendid
- Airco TOSOT
- Airco SereneLife
- Airco Danby
- Airco APC
- Airco Ariston Thermo
- Airco Evolar
- Airco RCA
- Airco Daikin
- Airco Esatto
- Airco Orbegozo
- Airco Dantherm
- Airco Furrion
- Airco General Electric
- Airco Ridgid
- Airco Daitsu
- Airco Defy
- Airco Edgestar
- Airco Emerson
- Airco Fairland
- Airco Firstline
- Airco Fral
- Airco Fronius
- Airco Fuave
- Airco Fuji Electric
- Airco Jocel
- Airco Just Fire
- Airco Kenmore
- Airco Maiko
- Airco Maxicool
- Airco Mistral
- Airco MundoClima
- Airco Prem-i-air
- Airco Protector
- Airco SMC
- Airco SPT
- Airco Stirling
- Airco Tarrington House
- Airco Teco
- Airco Trilec
- Airco Tronix
- Airco Whynter
- Airco Argoclima
- Airco Elgin
- Airco Kunft
- Airco Becken
- Airco Rinnai
- Airco Ravanson
- Airco Godrej
- Airco Friedrich
- Airco NewAir
- Airco Klimaire
- Airco EcoFlow
- Airco Brivis
- Airco Geist
- Airco Monzana
- Airco Simplicity
- Airco Kaden
- Airco Equation
- Airco Daizuki
- Airco Braemar
- Airco Equator
- Airco Khind
- Airco Krone
- Airco American Comfort
- Airco Riffel
- Airco Bonaire
- Airco MRCOOL
- Airco Arcoaire
- Airco Companion
- Airco SEEGER
- Airco Heat Controller
- Airco LERAN
- Airco IFB
- Airco ActronAir
- Airco Consul
- Airco HTW
- Airco B-Air
- Airco Mabe
- Airco House & Luft
- Airco DEXP
- Airco Evapcool
- Airco Ocean Breeze
- Airco Commercial Cool
- Airco Kaco
- Airco InAlto
- Airco Climachill
- Airco Create
- Airco Bodin
- Airco ARCTIC WIND
- Airco JHS
- Airco Keystone
- Airco FREONIC
- Airco Big Ass Fans
- Airco Electroline
- Airco Omega Altise
- Airco TURBRO
- Airco Norpole
- Airco Kubo
- Airco KDK
- Airco Hokkaido
- Airco Evapolar
- Airco Liebert
- Airco CĆ©liera
- Airco AFINTEK
- Airco Avallon
- Airco Columbia Vac
- Airco Vostok
- Airco Quirky
- Airco KwiKool
- Airco Senville
- Airco Goodwe
- Airco Swegon
- Airco BOSFOR
- Airco Aconatic
- Airco AireMax
- Airco VƤnEE
- Airco Mayer
- Airco Perfect Aire
- Airco Koldfront
Neueste Bedienungsanleitung fĆ¼r -Kategorien-
6 Oktober 2024
6 Oktober 2024
6 Oktober 2024
5 Oktober 2024
5 Oktober 2024
5 Oktober 2024
5 Oktober 2024
4 Oktober 2024
4 Oktober 2024
4 Oktober 2024