SPECIFICATIONS
Model: LS1019 LS1019L
Blade diameter European countries 260 mm
Countries other than Europe 255 mm - 260 mm
Hole diameter European countries 30 mm
Countries other than Europe 25.4 mm
Max. kerf thickness of the saw blade 3.2 mm
Max. miter angle Right 60°, Left 60°
Max. bevel angle Right 48°, Left 48°
No load speed (RPM) 3,200 min-1
Laser type Red Laser 650 nm, Maximum -
output 1.6mW ( Laser
Class 2M )
Dimensions (L x W x H) 805 mm x 644 mm x 660 mm
Net weight 26.1 kg 26.3 kg
Cutting capacities (H x W)
Miter angle Bevel angle
45° (left) 45° (right)0°
0° 42 mm x 310 mm
58 mm x 279mm
68 mm x 310 mm
91 mm x 279 mm
29 mm x 310 mm
43 mm x 279 mm
45° (right and left) 42 mm x 218 mm
58 mm x 197 mm
68 mm x 218 mm
91 mm x 197 mm
29 mm x 218 mm
43 mm x 197 mm
60° (right and left) 68 mm x 155 mm-
91 mm x 139 mm
-
Cutting capacities for special cuttings
Type of cutting Cutting capacity
Crown molding 45° type
(with crown molding stopper used)
168 mm
Base board
(with horizontal vise used)
133 mm
• Duetoourcontinuingprogramofresearchanddevelopment,thespecicationshereinaresubjecttochange
without notice.
• Specicationsmaydifferfromcountrytocountry.
• WeightaccordingtoEPTA-Procedure01/2014
Symbols
The following show the symbols used for the equip-
ment. Be sure that you understand their meaning before
use.
Read instruction manual.
DOUBLE INSULATION
Toavoidinjuryfromyingdebris,keep
holding the saw head down, after making
cuts, until the blade has come to a com-
plete stop.
Whenperformingslidecut,rstpullcar-
riage fully and press down handle, then
push carriage toward the guide fence.
Donotplacehandorngersclosetothe
blade.
Never look into the laser beam. Direct laser
beammayinjureyoureyes.
Only for EU countries
Do not dispose of electric equipment
together with household waste material! In
observance of the European Directive, on
Waste Electric and Electronic Equipment
and its implementation in accordance with
national law, electric equipment that have
reached the end of their life must be col-
lected separately and returned to an envi-
ronmentally compatible recycling facility.
Intended use
The tool is intended for accurate straight and miter
cutting in wood. With appropriate saw blades, aluminum
can also be sawed.
3 ENGLISH
Power supply
The tool should be connected only to a power supply of
the same voltage as indicated on the nameplate, and
can only be operated on single-phase AC supply. They
are double-insulated and can, therefore, also be used
from sockets without earth wire.
Noise
The typical A-weighted noise level determined accord-
ing to 62841-3-9:
Model LS1019
Sound pressure level (L
pA) : 91 dB(A)
Sound power level (L
WA) : 101 dB (A)
Uncertainty (K) : 3 dB(A)
Model LS1019L
Sound pressure level (L
pA) : 91 dB(A)
Sound power level (L
WA) : 101 dB (A)
Uncertainty (K) : 3 dB(A)
WARNING: Wear ear protection.
Vibration
The vibration total value (tri-axial vector sum) deter-
mined according to 62841-3-9:
Model LS1019
Vibration emission (a
h):2.5m/s2 or less
Uncertainty(K):1.5m/s
2
Model LS1019L
Vibration emission (a
h):2.5m/s2 or less
Uncertainty(K):1.5m/s
2
NOTE: The declared vibration emission value has
been measured in accordance with the standard test
method and may be used for comparing one tool with
another.
NOTE: The declared vibration emission value
may also be used in a preliminary assessment of
exposure.
WARNING: The vibration emission during actual
use of the power tool can differ from the declared
emission value depending on the ways in which the
tool is used.
WARNING: Be sure to identify safety measures
to protect the operator that are based on an estima-
tion of exposure in the actual conditions of use (taking
account of all parts of the operating cycle such as
the times when the tool is switched off and when it is
running idle in addition to the trigger time).
EC Declaration of Conformity
For European countries only
The EC declaration of conformity is included as Annex A
to this instruction manual.
SAFETY WARNINGS
General power tool safety warnings
WARNING: Read all safety warnings, instruc-
tions, illustrations and speciî‚¿cations provided
with this power tool. Failure to follow all instructions
listedbelowmayresultinelectricshock,reand/or
seriousinjury.
Save all warnings and instruc-
tions for future reference.
The term "power tool" in the warnings refers to your
mains-operated (corded) power tool or battery-operated
(cordless) power tool.
Work area safety
1. Keep work area clean and well lit. Cluttered or
dark areas invite accidents.
2. Do not operate power tools in explosive atmo-
spheres, such as in the presence of ammable
liquids, gases or dust. Power tools create sparks
which may ignite the dust or fumes.
3. Keep children and bystanders away while
operating a power tool. Distractions can cause
you to lose control.
Electrical Safety
1. Power tool plugs must match the outlet. Never
modify the plug in any way. Do not use any
adapter plugs with earthed (grounded) power
tools. Unmodiedplugsandmatchingoutletswill
reduce risk of electric shock.
2. Avoid body contact with earthed or grounded
surfaces, such as pipes, radiators, ranges and
refrigerators. There is an increased risk of elec-
tric shock if your body is earthed or grounded.
3. Do not expose power tools to rain or wet con-
ditions. Water entering a power tool will increase
the risk of electric shock.
4. Do not abuse the cord. Never use the cord for
carrying, pulling or unplugging the power tool.
Keep cord away from heat, oil, sharp edges
or moving parts. Damaged or entangled cords
increase the risk of electric shock.
5. When operating a power tool outdoors, use an
extension cord suitable for outdoor use. Use of
a cord suitable for outdoor use reduces the risk of
electric shock.
6. If operating a power tool in a damp location
is unavoidable, use a residual current device
(RCD) protected supply. Use of an RCD reduces
the risk of electric shock.
7. Use of power supply via an RCD with a rated
residual current of 30 mA or less is always
recommended.
Personal Safety
1. Stay alert, watch what you are doing and use
common sense when operating a power tool.
Do not use a power tool while you are tired or
under the inuence of drugs, alcohol or med-
ication. A moment of inattention while operating
powertoolsmayresultinseriouspersonalinjury.


Produktspezifikationen

Marke: Makita
Kategorie: Säge
Modell: LS1019

Brauchst du Hilfe?

Wenn Sie Hilfe mit Makita LS1019 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Säge Makita

Bedienungsanleitung Säge

Neueste Bedienungsanleitung für -Kategorien-