LG LKAEH188 Bedienungsanleitung

LG Klimaanlage LKAEH188

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für LG LKAEH188 (4 Seiten) in der Kategorie Klimaanlage. Dieser Bedienungsanleitung war für 8 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/4
1
ENGLISH
ENGLISH
ENGLISH
ENGLISHENGLISH ESPAÑOL
ELECTRIC HEATERS
INSTALLATION INSTRUCTIONS
Models: LKAEH098, LKAEH188, LKAEH368, LKAEH368L
• Please read this instruction sheet completely before installing the product.
• Installation work must be performed in accordance with national wiring standards by authorized
personnel only.
P/No.: 3828A30038F
2
Table 1 Accessory Heaters Electrical Data
Ton
6.25/7.5RT
8.5/10/12.5RT
15/17.5RT
20/25RT
Heater
Model No.
Heater
KW Rating
Control
Stages
26.0/27.2
37.5/39.5
60.5/64.5
42.0/43.2
53.5/55.5
76.5/80.5
79.4/95.3
100.2/120.3
108.6/130.4
380-415/50/3
380-415/50/3
380-415/50/3
380-415/50/3
380-415/50/3
380-415/50/3
380-415/50/3
380-415/50/3
380-415/50/3
LKAEH098
LKAEH188
LKAEH368
LKAEH098
LKAEH188
LKAEH368
LKAEH188
LKAEH368
LKAEH368L
7.5/9.0
15.1/18.0
30.2/36.0
7.5/9.0
15.1/18.0
30.2/36.0
15.1/18.0
30.2/36.0
30.2/36.0
1
1
2
1
1
2
1
2
2
60/60
60/60
80/80
60/60
70/70
100/100
125/125
150/150
150/150
60/60
60/60
80/80
60/60
70/70
100/100
125/125
150/150
150/150
31.0/32.2
42.5/44.5
65.5/69.5
47.0/48.2
58.5/60.5
81.5/85.5
85.4/101.3
106.2/126.3
114.6/136.4
60/60
60/60
80/80
60/60
80/80
100/100
125/125
150/150
150/150
60/60
60/60
80/80
60/60
80/80
100/100
125/125
150/150
150/150
Heater
Rated Volts
Standard indoor fan motor
M.C.A M.C.AM.F.S M.F.SM.C.B M.C.B
Oversized indoor motor
Note: Heater KW ratings are at 380/415V for 380/415V unit.
M.C.A; Minimum Circuit Ampere
M.F.S; Maximum Fuse Size
M.C.B; Maximum Circuit Breaker
* HACR type Circuit Breaker per NEC.
Installation
1. Loosen the screw that secures heater
compartment access panel. Lift up, pull
towards you and slide it down to remove.
2. Remove four(4) screws from block off panel
to expose heater cavity and heaterʼs back
support bracket. Save screws for installing
heater later.(See Figure 2.)
Heater Access Panel
Compressor Access Panel
Figure 1
Figure 2
: Open and lock unit disconnect
switch before installing this accessory to prevent
injury or death due to electrical shock or contact
with moving parts.
WARNING
Support
Bracket
Block off panel
Heater Cavity
ENGLISH
ENGLISH
ENGLISH
ENGLISHENGLISH
3
Heater and Control Box Assembly
3. Insert heater into the opening hole of heater
control box.
4. Align holes and secure screws to the control
box as shown in Figure 3.
Single Bank Heater Installation
-
LKAEH098, LKAEH188, LKAEH368L
5. Place the heater control assembly in the
heater cavity.
6. Secure the heater control assembly of
heater cavity using four(4) screws. (See
Figure 4.)
Important: Make sure the heater arm slides
into heaterʼs back support bracket.
Two Bank Heaters Installation
-
LKAEH368
7. For two heaters installation, align holes and
secure screws to the control box as shown
in Figure 3.
8. Secure the heater control assembly on
heater cavity using four(4) screws.(See
Figure 5)
Important: Make sure the heaterʼs arm slides
into heaterʼs back support bracket.
Heater Control Box
Heater
Figure 3
Figure 4
Figure 5


Produktspezifikationen

Marke: LG
Kategorie: Klimaanlage
Modell: LKAEH188

Brauchst du Hilfe?

Wenn Sie Hilfe mit LG LKAEH188 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Klimaanlage LG

Bedienungsanleitung Klimaanlage

Neueste Bedienungsanleitung für -Kategorien-