FEATURES:
ATOMIC CLOCK:
WWVB Radio controlled time with manual time setting
12/24 hour time display
Time display: hour, minute, second
Alarm setting with snooze function
Calendar display
Weekday display (3 languages to choose from: English, French and Spanish)
Time zone setting
Daylight savings time ON/OFF option (DST)
ºC or ºF temperature display selectable
Indoor temperature display
Outdoor temperature display via 433MHz transmission
Wall mount or freestanding
Current moon phase display
OUTDOOR TEMPERATURE TRANSMITTER:
Holder
Remote transmission of outdoor temperature to the atomic clock by 433 MHz signals
Wall mounting case
TO INSTALL AND REPLACE BATTERIES IN THE ATOMIC CLOCK
The atomic clock uses 2 x AA, 1.5V batteries. To install and replace the batteries, please follow the
steps below:
1. Insert finger or other solid object in the space at the bottom center of the battery compartment
and lift up to remove the cover.
2. Insert batteries observing the correct polarity (see marking inside battery compartment).
3. Replace compartment cover.
DO NOT SET THE CLOCK.
TO INSTALL AND REPLACE BATTERIES IN THE TEMPERATURE TRANSMITTER
The transmitter uses 2 x AA,1.5V batteries. To install and replace the batteries, please follow the
steps below:
1. Remove the cover.
2. Insert the batteries, observing the correct polarity (see marking inside battery compartment).
3. Replace the battery cover on the unit.
Alkaline batteries are recommended for use in both units. Avoid using rechargable batteries.
SETTING UP:
LCD2
display
Battery cover
Function keys
LCD1
display
Hanging holes
Foldable stand
Alkaline batteries are recommended for use in both units. Avoid using rechargable
batteries.
NOTE: Do not set the clock until the outdoor temperature is displayed.
1. Place batteries in the outdoor transmitter first, then into the atomic clock. DO NOT
PRESS ANY BUTTONS FOR 10 MINUTES.
2. After the 10 minutes both the Indoor and Outdoor areas on your clock should have a
temperature showing. If not, remove both sets of batteries, wait 10 minutes and repeat step
one.
3. After the clock receives the outdoor temperature the WWVB time code reception will
automatically start. This reception typically takes between 5-10 minutes in good conditions. If
after 10 minutes the WWVB time has not been received, use the “SET” key to manually enter
the set-up mode and change either the time or date in order to activate the WWVB reception
(see manual settings below). The clock will then automatically attempt to receive the WWVB
time from 12:00 am through 6:00 am each day (attempts WWVB reception every full hour within
this time frame). When this is successful, the received time will override the manually set time.
The date is also updated with the received time (Please refer to notes on “Radio controlled
time” and “Manual time setting”).
4. After the time signal has been received or the search mode has been manually stopped the
indoor temperature will be displayed.
Note:
In the event of changing batteries of the unit ensure that the batteries do not spring free from the
contacts. Always wait at least 10 minutes after removing the batteries before reinserting, otherwise
start up and transmission problems may occur.
FUNCTION KEYS
The atomic clock has four easy to use keys:
SET key : To enter into the set mode for the following functions: time zone, DST ON/OFF
(daylight saving time), language, hour, minute, year, month, day, weekday, 12/24
hour, ºC or ºF temperature display
+ key : To toggle between the second, temperature or weekday display
To change any values in manual set mode
ALM key : To enter into the alarm set mode
To set the alarm ON/OFF
SNZE key : To activate the snooze function during alarm
To display the alarm time in normal mode display
To exit the setting modes
ATOMIC CLOCK LCD SCREEN DESCRIPTIONS
The atomic clock's LCD is divided into 2 sections and once the batteries are inserted, all the
segments will light up briefly before displaying the information for time, date, indoor and outdoor
temperatures.
MANUAL SETTINGS
Note:
If the atomic clock has already successfully received the WWVB time signal and displays the
correct time and date, then the Manual settings can be skipped.
After completion of the above described procedures inSetting up the manual setting modes can
be entered by pressing and holding the SET key for 3 seconds. The following settings can now be
programmed:
Time zone setting
DST ON/OFF
Language display setting
Manual time setting
Year setting
Date
Outdoor temperature display
Radio reception icon
A
larm icon
WWVB time
Weekday
Indoor temperature
Month setting
Date setting
Weekday setting
12/24 hour time display setting
ºC or ºF setting
TIME ZONE SETTING
After entering the manual setting mode as descri can be set between the –1 bed above, the time zone
to –12 hour or Greenwich Mean Time (GMT) range in LCD2. To do this:
1. The time zone (LCD2) will start flashing (Default setting "-5h“). Select the desired time zone by
pressing and releasing the + key.
Note: The time zones from –4 to –10 hours will be displayed with 3 characters abbreviations:
-4 ATL (Atlantic time),
-5 EST (Eastern time; default time zone),
-6 CST (Central time),
-7 MST (Mountain time),
-8 PST (Pacific time),
-9 ALA (Alaska time),
-10 HAW (Hawaii time).
"GMT” will be displayed if set to GMT (0).
2. Press and release the SET key to enter the “DST Setting.
DST SETTING (daylight saving time)
1. The ON digit will start flashing on LCD1. Set the DST ON or OFF by pressing the + key.
2. Press and release the SET key to enter the “Language Setting“.
Note:
The DST default is “ON”, meaning that the WWVB will automatically change the time according to
Daylight Saving Time in the spring and fall. For areas that do not recognize DST changes (Arizona
and parts of Indiana) turn the DST “OFF”.
LANGUAGE SETTING
The weekdays can be displayed in LCD2 with the pre-set languages: US English, French and
Spanish.
1. Set the desired language for the weekday display in LCD 2 by use of the + key.
2. Press and release the SET key to enter the mode “Manual Time Setting”.
MANUAL TIME SETTING
In case the atomic clock is not able to detect the WWVB-signal (disturbances, transmitting distance,
etc.), the time can be manually set. The clock will then work as a normal Quartz clock.
Note: In 12 hours mode the time will be displayed with an additional “ ”PM for the time from 12:00
noon until 11:59.
1. The hour digits will start flashing on LCD1.
2. Set the desired hours by pressing and releasing the + key followed by pressing the SET key.
3. Now the minute digits will start flashing.
4. Set the desired minutes by pressing and releasing the + key . If the + key is held, the units will
increase by 5.
5. Press and release the SET key to move to the “Year Setting”.
Note:
The unit will still try and receive the signal every day despite it being manually set. When it does
receive the signal, it will change the manually set time into the received time. During reception
attempts the WWVB tower icon will flash. If reception has been unsuccessful, then the WWVB tower
icon will not appear but reception will still be attempted the following hour.
WWVB time reception takes place from 12:00 am through 6:00 am each day (attempts WWVB
reception every full hour within this time frame). When the time signal is received for example at 1:00
am, the atomic clock will not attempt to receive the WWVB signal for the remaining hours until 6:00
am. Therefore, the next signal attempt will take place between 12:00 am and 6:00 am the next day.
The other times WWVB reception takes place, are upon setup and after manual time set exiting
mode. Reception is generally not possible during daylight hours due to the interference of the sun.


Produktspezifikationen

Marke: La Crosse Technology
Kategorie: Uhr
Modell: WS-6118AL

Brauchst du Hilfe?

Wenn Sie Hilfe mit La Crosse Technology WS-6118AL benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Uhr La Crosse Technology

Bedienungsanleitung Uhr

Neueste Bedienungsanleitung für -Kategorien-