La Crosse Technology 515-1912 Bedienungsanleitung
La Crosse Technology
Uhr
515-1912
Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für La Crosse Technology 515-1912 (2 Seiten) in der Kategorie Uhr. Dieser Bedienungsanleitung war für 13 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet
Seite 1/2
Page 3 Page 4Page 2
S P L A S H P R O O F ATO M I C C LO C K
WITH OUT DOO R T EM PERAT URE / HUMIDIT Y
QUIC K START G UID E
MODEL: 5151912
DC: 021819
Full manual can be found under the Support tab here: bit.ly/515-1912
P O W E R U P
1. Insert 2-AA batteries into your Outdoor Sensor.
2. Insert 2-AA batteries into your Atomic Clock.
3. Configure basic Settings.
4. Once the sensor is reading to your clock, place sensor
outside in a shaded location.
Watch sensor mounting video: bit.ly/TH_SensorMounting
AA
AA
TX191TH
Outdoor Sensor
S E T T I N G S
AA
AA
• The clock will only search for the WWVB Atomic Time Signal at
UTC 7:00, 8:00, 9:00, 10:00, and 11:00.
• The Atomic Time Indicator will flash while searching, and will
remain solid on screen when connected.
• From the normal time display, press the SET button to search for
the WWVB Atomic Time Signal.
515-1912
Atomic Clock
ATO M I C TI M E SI G N A L - W W V B
1. Hold the SET button to enter the Settings Menu.
2. Press the + or - button to adjust the flashing values. Hold to
adjust quickly.
3. Press the SET button to confirm adjustments and move to the
next item.
4. Press the TIMER button at any time to exit.
Note: Weekday sets automatically when Year, Month and Date are
set.
Settings Order:
• Beep ON/OFF
• Atomic ON/OFF
• DST (Daylight Saving Time)
o DST ON
o DST OFF
o DST ALWAYS ON
• Time Zone
• Hour
• Minutes
• Year
• Month
• Date
• Fahrenheit/Celsius
TIME ZONES
AST = Atlantic
EST = Eastern
CST = Central
MST = Mountain
PST = Pacific
AKT = Alaska
HAT = Hawaii
DST ON- Clock gains 1 hour in spring
and loses 1 hour in the fall.
DST OFF- Clock remains in Standard
Time all year long.
DST ALWAYS ON- Clock remains in
Daylight Saving Time all year long.
C U S TOM D I S P L AY V I E W S
Press the MINUS (-) button to select between:
• Outdoor Temperature & Humidity
• Indoor Temperature and Seconds to display.
When Timer is active the Timer Icon and Timer Countdown will
show.
B U T TO N S
+-
TIMER SETMINUS (-)PLUS (+)
TimerOutdoor Temp/Humidity Indoor Temp & Seconds
P O SI T I O N
• Use the slot on the battery cover to mount your clock with a
screw, or insert the suction cup attachment into the slot and
mount on a clean, smooth surface.
• When using suction cup, occasionally press and hold the clock to
be sure it is secure.
Hang on a
screw or
with the
suction cup
DO NOT
place clock
in direct
contact with
water
Page 6Page 5 Page 7 Page 8
LO W B ATT E R Y I N D I CATOR
• When battery appears in Outdoor Temperature section, replace
batteries in your Outdoor Sensor.
• When battery appears next to the Time, replace batteries in your Atomic
Clock.
S P E C I F I C AT I O N S
S E N S O R W E AT H ER SH I E L D - N O T I N C LU D E D
• The Sensor Weather Shield is designed to
protect your outdoor sensor from rain and snow.
• This shield will oer limited protection from the sun’s
heat.
• Optional purchase at: http://bit.ly/925-1418
If you require additional support, call our friendly customer support
team based out of La Crosse, Wisconsin.
Phone: 1.608.782.1610
Or fill out our online support request form here:
bit.ly/contact_techsupport
Our knowledgeable customer support team is available:
Monday-Friday, 8am-6pm CST.
JOIN THE CONVERS AT ION
Ask questions, watch detailed setup videos, and provide feedback
on our social media outlets!
W E ’ R E H E R E TO H E L P !
Indoor Temperature Range: 32°F to 99°F (0°C to 37°C)
Outdoor Temperature Range: -40°F to 140°F (-40°C to 60°C)
Outdoor Humidity Range: 10% RH to 99%
Transmission Range: 330 feet (100 meters) open air RF 433MHz
Power Requirements:
Clock: 2-AA batteries not included
TX191TH sensor: 2-AA batteries not included
Battery Life:
Clock: Over 12 months
Tx191TH Sensor: Over 24 months
Dimensions:
Clock: 4.92” L x 1.36” W x 5.12” H (12.49cm L x 3.45cm W x 13cm H)
TX191TH Sensor: 1.57” L x 0.95” W x 4.49” H (4cm L x 2.4cm W x 11.4cm H)
T I M E R
Set Timer:
1. Hold the TIMER button until you see the Minutes begin to flash.
Press the + or – button to adjust the minutes (1-99).
2. Press the TIMER button to confirm and exit.
Timer Icon will show when Timer is active.
Start/Pause/Restart Timer:
• Timer will start automatically once it is set.
• Press the TIMER button to pause the timer. Timer Icon will flash.
• Press the TIMER button again to resume the timer countdown.
Stop Timer:
• While timer is showing, press any button except Timer button, to
stop the timer.
• The Timer will automatically return to the last countdown time
set. This value will show for 3 seconds then clock will default to
normal clock display with Temp/Humidity.
Timer Sounds
• When Timer Countdown reaches 0, the timer will sound 5 beeps
every 15 seconds for up to up to 1 minute. Press any button to
stop the sounding timer.
S E A R C H F O R O U T D O O R SE N S O R
• If the Outdoor Sensor loses connection to the clock for any reason, the
clock will show after 30 minutes.NO
• The clock will search for 3 minutes every hour to reconnect with sensor.
• To manually search for the Outdoor Sensor, old the PLUS (+) button until
the Reception Icon begins to flash.
Set Timer Minutes
(1 to 99 minutes)
Timer
Countdown
WA R R A N T Y I N F O
La Crosse Technology, Ltd. provides a (from date of purchase) on this product 1-year limited time warranty
relating to manufacturing defects in materials & workmanship.
La Crosse Technology, Ltd
2830 S. 26th St.
La Crosse, WI 54601
For Full Warranty Details, Visit: www.lacrossetechnology.com/support
CA R E + M AI N T E N AN C E
• Do not mix old and new batteries.
• Do not mix Alkaline, Lithium, standard, or rechargeable batteries.
• Always purchase the correct size and grade of battery most suitable for intended use.
• Clean the battery contacts and also those of the device prior to battery installation.
• Ensure the batteries have with correct polarity (+ / -).
• Remove batteries from equipment that will not to be used for an extended period.
• Promptly remove expired batteries.
F CC STAT E M E N T
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant
to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause harmful interference to
radio communications. However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of
the following measures:
• Reorient or relocate the receiving antenna.
• Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected.
• Increase separation between equipment & receiver.
• Consult the dealer or an experienced radio/TV technician for help.
This device must not be co-located or operating in conjunction with any other antenna or transmitter.
Operation is subject to the following two conditions:
(1 ) This device may not cause harmful interference, and (2) This device must accept any interference received,
including interference that may cause undesired operation.
CAUTION!
The manufacturer is not responsible for any radio or TV interference caused by unauthorized changes or
modifications to this equipment. Such changes or modifications could void the user authority to operate the
equipment.
All rights reserved. This manual may not be reproduced in any form, even in part, or duplicated or processed
using electronic, mechanical or chemical process without the written permission
of the publisher.
This booklet may contain errors or misprints. The information it contains is regularly checked and corrections
are included in subsequent editions. We disclaim any responsibility for any technical error or printing error, or
their consequences. All trademarks and patents are recognized.
WARNING: This product can expose you to chemicals including styrene, which is known to the State of
California to cause cancer. For more information go to: www.P65Warnings.ca.gov
Produktspezifikationen
Marke: | La Crosse Technology |
Kategorie: | Uhr |
Modell: | 515-1912 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit La Crosse Technology 515-1912 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Uhr La Crosse Technology
4 Oktober 2024
4 Oktober 2024
2 Oktober 2024
2 Oktober 2024
30 September 2024
27 September 2024
24 September 2024
22 September 2024
21 September 2024
20 September 2024
Bedienungsanleitung Uhr
- Uhr Samsung
- Uhr Hama
- Uhr Nedis
- Uhr Profile
- Uhr Camry
- Uhr Velleman
- Uhr IKEA
- Uhr ADE
- Uhr Alecto
- Uhr Auriol
- Uhr Cresta
- Uhr Denver
- Uhr Dexford
- Uhr ECG
- Uhr Eurochron
- Uhr Gira
- Uhr Irox
- Uhr Jacob Jensen
- Uhr König
- Uhr MarQuant
- Uhr Mebus
- Uhr Sempre
- Uhr Techno Line
- Uhr Technoline
- Uhr TFA
- Uhr Trevi
- Uhr Weinberger
- Uhr Braun
- Uhr SEG
- Uhr Tronic
- Uhr Geemarc
- Uhr Muse
- Uhr Elro
- Uhr Livoo
- Uhr Jaguar
- Uhr Lotus
- Uhr Michael Kors
- Uhr Casio
- Uhr Citizen
- Uhr United Office
- Uhr Balance
- Uhr Fysic
- Uhr Karlsson
- Uhr Krontaler
- Uhr Mondaine
- Uhr Fisher-Price
- Uhr Lenovo
- Uhr Xiron
- Uhr Suunto
- Uhr Globaltronics
- Uhr Ascot
- Uhr Zuiver
- Uhr Hager
- Uhr Edox
- Uhr Lorus
- Uhr Huawei
- Uhr JUNG
- Uhr Lexon
- Uhr Ranex
- Uhr Kogan
- Uhr Audiovox
- Uhr Salter
- Uhr Davis
- Uhr Diesel
- Uhr Invicta
- Uhr Orient
- Uhr Zenith
- Uhr Vitek
- Uhr Elation
- Uhr RCA
- Uhr AV:link
- Uhr McIntosh
- Uhr ART
- Uhr Oregon Scientific
- Uhr Digi-tech
- Uhr Dormakaba
- Uhr Ecom
- Uhr Gingko
- Uhr Global Tronics
- Uhr Glunz
- Uhr Hermle
- Uhr IHome
- Uhr La Crosse
- Uhr Lydion
- Uhr QQ
- Uhr Taylor
- Uhr World Timer Chronograph
- Uhr TFA Dostmann
- Uhr Equity
- Uhr AcuRite
- Uhr DB Technologies
- Uhr Amplicom
- Uhr Electronics International
- Uhr Chacon
- Uhr Pyramid
- Uhr Focus Electrics
- Uhr Antelope Audio
- Uhr ASA
- Uhr CyberData Systems
- Uhr Antelope
- Uhr Accusplit
- Uhr Balance Time
- Uhr Valcom
- Uhr BBrain
- Uhr Bearware
Neueste Bedienungsanleitung für -Kategorien-
7 Oktober 2024
6 Oktober 2024
5 Oktober 2024
3 Oktober 2024
17 September 2024
16 September 2024
9 September 2024
7 September 2024
6 September 2024
6 September 2024