Klein Tools ET270 Bedienungsanleitung


Lesen Sie kostenlos die đŸ“– deutsche Bedienungsanleitung fĂ¼r Klein Tools ET270 (36 Seiten) in der Kategorie Messgeräte. Dieser Bedienungsanleitung war fĂ¼r 3 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/36
INSTRUCTION MANUAL
ENGLISH
• AUTO-RANGING
WITH DATA HOLD
• AUDIBLE
CONTINUITY
• BATTERY TEST
• PERFORMS
STANDARD AND
GFCI WIRING
FAULT TESTS
• INDICATES
A CIRCUIT'S
BREAKER IN
FIND MODE
FRANÇAIS p. 25
ESPAĂ‘OL pg. 13
Multi-Tester DMM with
Receptacle Tester
ET270
2m
CAT III
600V
600V
40M
Ω
5001748
2
GENERAL SPECIFICATIONS
Klein Tools' ET270 is an auto-ranging digital multi-tester that measures
AC/DC voltage, resistance, continuity, and performs a battery test. It also
tests wiring conditions in standard 120V and GFCI electrical receptacles
and inspects North American GFCI devices.
• Environment:
Indoor. DO NOT expose to moisture, rain, or snow.
• Operating Altitude: 6562 ft. (2000m)
• Relative Humidity: <80% non-condensing
• Operating Temp: ° ° ° °32 F to 104 F (0 C to 40 C)
• Storage Temp: ° ° ° °14 F to 140 F (-10 C to 60 C)
• Accuracy: Values stated at 65°F to 83°F (18°C to 28°C)
• Temp Coef cient: °0.1 x (Quoted Accuracy) per C above
28 C or below 18 C, corrections are required when ambient ° °
working temp is outside of Accuracy Temp range
• Dimensions: 6.41" Ă— 3.13" Ă— 1.84" (162.7 Ă— 79.4 Ă— 46.6 mm)
• Weight: 8.9 oz. (250 g)
• Calibration: Accurate for one year
• Standards: Conforms to: UL STD 61010-1, 61010-2-033, 1436.
Certified to: CSA STD C22.2 # 61010-1,
61010-2-033, 160.
IEC EN 61010-1, 61010-2-033, 61326-1.
• Pollution degree: 2
• Accuracy: ± (% of reading + # of least significant digits)
• Drop Protection: 6.6 ft. (2 m)
• Safety Rating: CAT III 600V, Class 2, Double insulation
CAT III: Measurement category III is applicable to test and
measuring circuits connected to the distribution part of the
building’s low-voltage MAINS installation.
• Electromagnetic Environment: IEC EN 61326-1. This
equipment meets requirements for use in basic and controlled
electromagnetic environments like residential properties,
business premises, and light-industrial locations.
Specifications subject to change.
ENGLISH
3
ELECTRICAL SPECIFICATIONS
VOLTAGE (AUTO-RANGING)
Function Range Resolution Accuracy
AC Voltage
(V AC)
400.0V 100mV ±(1.2% + 5 digits)
600V 1V ±(1.2% + 3 digits)
DC Voltage
(V DC)
4000mV 1mV ±(1.0% + 5 digits)
40.00V 10mV
±(1.0% + 3 digits)400.0V 100mV
600V 1V
Input Impedance: 10MΩ
Frequency Range: 50 to 60Hz
Maximum Input: 600V AC RMS or 600V DC
RESISTANCE (AUTO-RANGING)
Range Resolution Accuracy
400.0Ω 0.1Ω
±(1.0% + 5 digits)
4.000kΩ 1Ω
40.00kΩ 10Ω
400.0kΩ 100Ω
4.000MΩ 1kΩ ±(1.2% + 5 digits)
40.00MΩ 10kΩ ±(3.0% + 5 digits)
Maximum Input: 600V DC or 600V AC RMS
BATTERY TEST
Voltage Resolution Accuracy
9V 10mV ±(1.0% + 5 digits)
1.5V 1mV
Test Current: 9V (11~22.5mA), 1.5V (8~18mA)
OUTLET* TEST
Voltage Resolution Accuracy
30V AC - 150 V AC 1V ±(2.0% + 2 digits)
*NOTE: For North American, 120V, 50-60Hz, 3-wire receptacles only.
• Audible signal <10ΩContinuity Check:
• 3 samples per secondSampling Frequency:
• "OL" indicated on display, overload protection Overload:
600V RMS in all settings
• "-" on display indicates negative polarityPolarity:
• 3-3/4 digit, 4000 Count LCDDisplay:


Produktspezifikationen

Marke: Klein Tools
Kategorie: Messgeräte
Modell: ET270

Brauchst du Hilfe?

Wenn Sie Hilfe mit Klein Tools ET270 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Messgeräte Klein Tools

Bedienungsanleitung Messgeräte

Neueste Bedienungsanleitung fĂ¼r -Kategorien-