Product and Cabinet Opening Dimensions
237/ "8
(606 mm)
30"
(762 mm)
31/ " - 421/ "2
(88 mm - 106 mm)
331/ "2
(851 mm)
min. with
wheels
removed
241/ "2
(622 mm)
B
3/ "4
(19 mm)
A
30"
(762 mm)
33/ "4
(94 mm)
21"
(533 mm)
C
24"
(620 mm)
E
24"
(620 mm)
34"
(864 mm)
D
3"
(76 mm)
13/ "4
(44 mm)
63/ "4
(172 mm)
21/ "4
(64 mm)
21/ "4
(64 mm)
2"
(51 mm)
61
/ "4
(159 mm)
101/ "2
(267 mm)
4"
(102 mm)
A. Insulation may be compressed (not used on all models).
B. For panel-ready models, dishwasher depth is 24" (610 mm),
not including the 3/4" (19 mm) custom door panel.
C. Door handles may protrude forward of the face of the
dishwasher, varies by model.
For 4" (100 mm) toe kick, height of cabinet opening is 341/2" (863 mm).
Check that all surfaces have no protrusions
that would prohibit dishwasher installation.
D. Measured from the lowest point on the underside
of the countertop. May be reduced to 331/2"
(851 mm) by removing the wheels and perforated
area of insulation (blanket) on dishwasher.
E. Minimum, measured from narrowest point
of opening
NOTE: Shaded areas
of cabinet walls
show where utility
connections may
be installed.
8
ELECTRICAL REQUIREMENTS
Be sure that the electrical connection and wire size are
adequate and in conformance with the National Electrical
Code, ANSI/NFPA 70 - latest edition, and all local codes
and ordinances.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
You Must Have:
ā– 
120-volt, 60 Hz, AC-only, 15- or 20-amp, fused
electrical supply
ā– Copper wire only
ā– A maximum of 2 ļ¬eld wiring supply conductors
(12 AWG largest size) plus 1 grounding conductor
are permitted in the terminal box.
We Recommend:
ā– 
A time-delay fuse or circuit breaker
ā– A separate circuit
If Connecting Dishwasher with a Power Cord:
ā– Use UL Listed power cord kit marked for
use with dishwasher. See the ā€œTools and
Partsā€ section at the front of the guide for
part details and orders.
ā– 
Plug into a grounded 3 prong outlet. Outlet must
meet all local codes and ordinances.
If Connecting Dishwasher with Direct Wiring:
ā– Use ļ¬‚exible, armored, or nonmetallic
sheathed copper wire with grounding
wire that meets the wiring requirements
for your home and local codes and ordinances.
ā– 
Use a UL Listed/CSA Approved metallic strain relief.
See the ā€œTools and Partsā€ section at the front of the
guide for part details and orders.
DRAIN REQUIREMENTS
ā– 
A new drain hose is supplied with your dishwasher.
If drain hose is not long enough, use a new drain hose with a
maximum length of 12 ft (3.7 m) that meets all current AHAM/
IAPMO test standards, is resistant to heat and detergent, and
ļ¬ts the 1" (25 mm) drain connector of the dishwasher. See
the ā€œTools and Partsā€ section at the front of the guide for part
details and orders.
NOTE: Do not connect multiple drain hoses together.
ā– Make sure to connect drain hose to waste tee or disposer
inlet above drain trap in house plumbing and 20" (508 mm)
minimum above the ļ¬‚oor. It is recommended that the drain
hose either be looped up and securely fastened to the
underside of the counter or be connected to an air gap.
ā– Make sure to use an air gap if the drain hose is connected
to house plumbing lower than 20" (508 mm) above
subļ¬‚oor or ļ¬‚oor.
ā– 
If required, the air gap should be installed in accordance
with the air gap installation instructions. When you are
connecting the air gap, a rubber hose (not provided) will
be needed to connect to the waste tee or disposer inlet.
ā– Use 1/2" minimum I.D. drain line ļ¬ttings.
WATER SUPPLY REQUIREMENTS
ā– This dishwasher has a water heating feature and also
requires a connection to a hot water supply line.
ā– A hot water line with 20 to 120 psi (138 to 862 kPa)
water pressure can be veriļ¬ed by a licensed plumber.
ā– 120Ā°F (49Ā°C) water at dishwasher
ā– 3/8" O.D. copper tubing with compression ļ¬tting or ļ¬‚exible
braided water supply line. See the ā€œTools and Partsā€ section
at the front of the guide for part details and orders.
NOTE: 1/2" minimum plastic tubing is not recommended.
ā– A 90Ā° elbow with 3/4" hose connection with rubber washer.
See the ā€œTools and Partsā€ section at the front of the guide
for part details and orders.
ā– Do not solder within 6" (152 mm) of the water inlet valve.
ā– If installed in new construction, make sure the house
water supply lines have been ļ¬‚ushed prior to connecting
the dishwasher to remove any debris that may exist in
the supply line.
NOTE: If replacing an existing dishwasher, it is recommended
to install a new water line (see the ā€œTools and Partsā€ section at
the front of the guide for part details) and drain hose (supplied)
with the new dishwasher.
Use of air gap
Air gap


Produktspezifikationen

Marke: KitchenAid
Kategorie: SpĆ¼lmaschine
Modell: KDPE334G

Brauchst du Hilfe?

Wenn Sie Hilfe mit KitchenAid KDPE334G benƶtigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung SpĆ¼lmaschine KitchenAid

Bedienungsanleitung SpĆ¼lmaschine

Neueste Bedienungsanleitung fĆ¼r -Kategorien-