Jøtul F SHD Series 470
GB - Installation and Operating Instructions 2
FR - Manuel d’installation et dutilisation 22
ES - Instrucciones para instalación 43
IT - Manuale di installazione ed uso 64
NL - Installatie- en montagehandleiding 85
Jøtul F SHD Series470
Manual Version P00
Jøtul F SHD Jøtul F SHD Jøtul F SHD Jøtul F SHD471 473 474 476
The manuals which are enclosed with the product must be kept throughout the product’s entire service life. Les manuels fournis avec le produit doivent être
conservés pendant toute la durée de vie du produit. Los manuales suministrados con este producto deben guardarse durante todo el ciclo de vida del producto.
I manuali inclusi con il prodotto vanno conservati per l’intera durata di vita del prodotto. De bij de haard meegeleverde handleidingen moeten gedurende de
volledige gebruiksduur van de haard bewaard blijven.
2
1.0 Technical data
Material: Cast iron
Finish: Black paint
Type of fuel: Wood
Max. log length: 30 cm
Smoke outlet: Top, rear
Flue pipe dimension: Ø 150 mm/min. 177 cm2
cross section
Outside air connection: Alu. flex - Ø 100 mm
Product weight:
Burn chamber: 117 kg
Base, cast iron 39 kg
Pedestal, cast iron 32 kg
Leg, cast iron 33 kg
Jøtul F SHD, F SHD and F SHD471 473 474
can be delivered with the following sides:
Cast iron sides 27 kg
Aluminium sides 3 kg
Glass sides 5.5 kg
Jøtul F SHD476 :
Soapstone side panels 150 kg
Optional extra Floor plates, Outside air
connection, Rotating set for
the Jøtul F SHD 473
Product dimensions, distances: See Fig. 1
Technical data in acc. with EN 13240
Nominal heat output: 6,0 kW
Flue gas mass flow: 6,0 g/s
Recommended chimney draught: 12 Pa
Efficiency: 75%@6 kW
CO emissions (13% O2): 0,08%
Flue gas temperature: 305oC
Dust: < 20 mg/m3n @ 13% O2
Burn time: 2.0 kg/h
Operational type: Intermittent
Intermittent combustion here means normal use of a fireplace,
i.e. add more fuel as soon as the fire has burned down to embers.
2.0 Relationship to the
authorities
Installation of a fireplace must be carried out in compliance
with national laws and regulations. All local ordinances,
including those that refer to national and European standards,
must be complied with when products are installed.
The installation can only be put into use after it has been
checked by a qualified inspector.
Contact your local building authorities before installing a
new fireplace.
Table of contents
1.0 Technical data .............................................. 2
2.0 Relationship to the authorities ................... 2
3.0 Safety ............................................................ 3
4.0 Installation ..................................................8
5.0 Daily Use ..................................................... 16
6.0 Maintenance ...............................................17
7.0 Servicing ......................................................18
8.0 Optional Extras ............................................21
9.0 Recycling ......................................................21
10.0 Warranty .....................................................21
On all our products there is a label
indicating the serial number and
year. Write this number in the
place indicated in the installation
instructions.
Always quote this serial number
when contacting your retailer or Jøtul.
les combustibles recommandés.
Respectez les consignes d'utilisation. Utilisez uniquement
Verwenden Sie nur empfohlenen Brennstoffen.
Montage- und Bedienungsanleitung beachten.
Follow user`s instructions. Use only recommended fuels.
standard
Certificate/
The appliance can be used in a shared flue.
Minimum distance to adjacent combustible materials:
Emission of CO in combustion products
Serial no: Y-xxxx, Year: 200x
Manufacturer:
N-1602 Fredrikstad
Norway
Jøtul AS
POB 1441
Sweden
EUR Intermittent
Nominal heat output
Norway
Country
Operational type
Fuel type
Operation range
Efficiency
Klasse II
Classification
Standard
Flue gas temperature
Room heater fired by solid fuel
Product:
Jøtul
SP Sveriges Provnings- och
221546
Forskningsinstitut AB
SP Swedish National
Testing and Research
Institute
:
Approved by
:
:
:
:
:
:
:
Minimum distance to adjacent combustible materials:
OGC SP
EN
Serial no.
ENGLISH
3
3.0 Safety
NB! To guarantee optimal performance and safety, Jøtul
recommends that its stoves are fitted by a qualified installer (see
www.jotul.com for a complete list of dealers).
Any modifications to the product by the distributor, installer
or consumer may result in the product and safety features not
functioning as intended. The same applies to the installation of
accessories or optional extras not supplied by Jøtul. This may
also be the case if parts that are essential to the functioning
and safety of the fireplace have been disassembled or removed.
In all these cases, the manufacturer is not responsible or liable
for the product and the right to make a complaint becomes null
and void.
3.1 Fire Prevention Measures
There is a certain element of danger every time you use your
fireplace. The following instructions must therefore be followed:
The minimum safety distances when installing and using the
fireplace are given in .fig. 1
Ensure that furniture and other flammable materials are not
too close to the fireplace. Flammable materials should not be
placed within 1 metre of the fireplace.
Allow the fire to burn out. Never extinguish the flames with
water.
The fireplace becomes hot when lit and may cause burns if
touched.
Only remove ash when the fireplace is cold. Ash can contain
hot embers and should therefore be placed in a non-
flammable container.
Ash should be placed outdoors or be emptied in a place where
it will not present a potential fire hazard.
In case of chimney fire:
Close all hatches and vents.
Keep the firebox door closed.
Check the loft and cellar for smoke.
Call the fire service.
Before use after a fire an expert must check the fireplace
and the chimney in order to ensure that it is fully functional.
3.2 Floor
Foundation
You need to make sure the foundation is suitable for a fireplace.
See “1.0 Technical Data” for specified weight.
We recommend the removal of any flooring that is not attached
to the foundation (“floating floors”) beneath the installation.
Requirements for protection of wooden
flooring beneath the fireplace
The product has integrated floor protection and may therefore
be placed directly on a wooden floor.
Any inflammable floor coverings, such as linoleum, carpets, etc.
must be removed from under the product.
Requirements for protection of inflammable
floors in front of the fireplace
The front plate must comply with national laws and regulations.
Contact your local building authorities regarding restrictions and
installation requirements.
3.3 Walls
Distance to walls made of combustible material - see fig. 1a for
Jøtul F 471 SHD, F SHD and F 473 474 SHD. See fig. 1b for Jøtul
F SHD476 .
Distance to combustible wall protected by firewall: See fig. 1c
for Jøtul F SHD, F SHD and F 471 473 474 SHD. See fig. 1d for
Jøtul F SHD476 .
The fireplace may be used with an uninsulated flue pipe
provided the distances between the fireplace and walls made
of combustible materials are as shown in .fig. 1
Ensure that furniture and other flammable materials are not too
close to the fireplace. Flammable materials should not be placed
within 1000 mm of the fireplace.
NB: Pay particular attention to this when using revolving
pedestal!
3.4 Ceiling
If the ceiling above the fireplace is made of a combustible
material, the minimum distance between the fireplace and
ceiling must be 1000 mm.