Jøtul F 473 Bedienungsanleitung
Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Jøtul F 473 (108 Seiten) in der Kategorie Heizung. Dieser Bedienungsanleitung war für 39 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet
Seite 1/108
Jøtul F SHD Series 470
GB - Installation and Operating Instructions 2
FR - Manuel d’installation et d’utilisation 22
ES - Instrucciones para instalación 43
IT - Manuale di installazione ed uso 64
NL - Installatie- en montagehandleiding 85
Jøtul F SHD Series470
Manual Version P00
Jøtul F SHD Jøtul F SHD Jøtul F SHD Jøtul F SHD471 473 474 476
The manuals which are enclosed with the product must be kept throughout the product’s entire service life. Les manuels fournis avec le produit doivent être
conservés pendant toute la durée de vie du produit. Los manuales suministrados con este producto deben guardarse durante todo el ciclo de vida del producto.
I manuali inclusi con il prodotto vanno conservati per l’intera durata di vita del prodotto. De bij de haard meegeleverde handleidingen moeten gedurende de
volledige gebruiksduur van de haard bewaard blijven.
2
1.0 Technical data
Material: Cast iron
Finish: Black paint
Type of fuel: Wood
Max. log length: 30 cm
Smoke outlet: Top, rear
Flue pipe dimension: Ø 150 mm/min. 177 cm2
cross section
Outside air connection: Alu. flex - Ø 100 mm
Product weight:
Burn chamber: 117 kg
Base, cast iron 39 kg
Pedestal, cast iron 32 kg
Leg, cast iron 33 kg
Jøtul F SHD, F SHD and F SHD471 473 474
can be delivered with the following sides:
Cast iron sides 27 kg
Aluminium sides 3 kg
Glass sides 5.5 kg
Jøtul F SHD476 :
Soapstone side panels 150 kg
Optional extra Floor plates, Outside air
connection, Rotating set for
the Jøtul F SHD 473
Product dimensions, distances: See Fig. 1
Technical data in acc. with EN 13240
Nominal heat output: 6,0 kW
Flue gas mass flow: 6,0 g/s
Recommended chimney draught: 12 Pa
Efficiency: 75%@6 kW
CO emissions (13% O2): 0,08%
Flue gas temperature: 305oC
Dust: < 20 mg/m3n @ 13% O2
Burn time: 2.0 kg/h
Operational type: Intermittent
Intermittent combustion here means normal use of a fireplace,
i.e. add more fuel as soon as the fire has burned down to embers.
2.0 Relationship to the
authorities
• Installation of a fireplace must be carried out in compliance
with national laws and regulations. All local ordinances,
including those that refer to national and European standards,
must be complied with when products are installed.
• The installation can only be put into use after it has been
checked by a qualified inspector.
• Contact your local building authorities before installing a
new fireplace.
Table of contents
1.0 Technical data .............................................. 2
2.0 Relationship to the authorities ................... 2
3.0 Safety ............................................................ 3
4.0 Installation ..................................................8
5.0 Daily Use ..................................................... 16
6.0 Maintenance ...............................................17
7.0 Servicing ......................................................18
8.0 Optional Extras ............................................21
9.0 Recycling ......................................................21
10.0 Warranty .....................................................21
On all our products there is a label
indicating the serial number and
year. Write this number in the
place indicated in the installation
instructions.
Always quote this serial number
when contacting your retailer or Jøtul.
les combustibles recommandés.
Respectez les consignes d'utilisation. Utilisez uniquement
Verwenden Sie nur empfohlenen Brennstoffen.
Montage- und Bedienungsanleitung beachten.
Follow user`s instructions. Use only recommended fuels.
standard
Certificate/
The appliance can be used in a shared flue.
Minimum distance to adjacent combustible materials:
Emission of CO in combustion products
Serial no: Y-xxxx, Year: 200x
Manufacturer:
N-1602 Fredrikstad
Norway
Jøtul AS
POB 1441
Sweden
EUR Intermittent
Nominal heat output
Norway
Country
Operational type
Fuel type
Operation range
Efficiency
Klasse II
Classification
Standard
Flue gas temperature
Room heater fired by solid fuel
Product:
Jøtul
SP Sveriges Provnings- och
221546
Forskningsinstitut AB
SP Swedish National
Testing and Research
Institute
:
Approved by
:
:
:
:
:
:
:
Minimum distance to adjacent combustible materials:
OGC SP
EN
Serial no.
ENGLISH
3
3.0 Safety
NB! To guarantee optimal performance and safety, Jøtul
recommends that its stoves are fitted by a qualified installer (see
www.jotul.com for a complete list of dealers).
Any modifications to the product by the distributor, installer
or consumer may result in the product and safety features not
functioning as intended. The same applies to the installation of
accessories or optional extras not supplied by Jøtul. This may
also be the case if parts that are essential to the functioning
and safety of the fireplace have been disassembled or removed.
In all these cases, the manufacturer is not responsible or liable
for the product and the right to make a complaint becomes null
and void.
3.1 Fire Prevention Measures
There is a certain element of danger every time you use your
fireplace. The following instructions must therefore be followed:
• The minimum safety distances when installing and using the
fireplace are given in .fig. 1
• Ensure that furniture and other flammable materials are not
too close to the fireplace. Flammable materials should not be
placed within 1 metre of the fireplace.
• Allow the fire to burn out. Never extinguish the flames with
water.
• The fireplace becomes hot when lit and may cause burns if
touched.
• Only remove ash when the fireplace is cold. Ash can contain
hot embers and should therefore be placed in a non-
flammable container.
• Ash should be placed outdoors or be emptied in a place where
it will not present a potential fire hazard.
In case of chimney fire:
• Close all hatches and vents.
• Keep the firebox door closed.
• Check the loft and cellar for smoke.
• Call the fire service.
• Before use after a fire an expert must check the fireplace
and the chimney in order to ensure that it is fully functional.
3.2 Floor
Foundation
You need to make sure the foundation is suitable for a fireplace.
See “1.0 Technical Data” for specified weight.
We recommend the removal of any flooring that is not attached
to the foundation (“floating floors”) beneath the installation.
Requirements for protection of wooden
flooring beneath the fireplace
The product has integrated floor protection and may therefore
be placed directly on a wooden floor.
Any inflammable floor coverings, such as linoleum, carpets, etc.
must be removed from under the product.
Requirements for protection of inflammable
floors in front of the fireplace
The front plate must comply with national laws and regulations.
Contact your local building authorities regarding restrictions and
installation requirements.
3.3 Walls
Distance to walls made of combustible material - see fig. 1a for
Jøtul F 471 SHD, F SHD and F 473 474 SHD. See fig. 1b for Jøtul
F SHD476 .
Distance to combustible wall protected by firewall: See fig. 1c
for Jøtul F SHD, F SHD and F 471 473 474 SHD. See fig. 1d for
Jøtul F SHD476 .
The fireplace may be used with an uninsulated flue pipe
provided the distances between the fireplace and walls made
of combustible materials are as shown in .fig. 1
Ensure that furniture and other flammable materials are not too
close to the fireplace. Flammable materials should not be placed
within 1000 mm of the fireplace.
NB: Pay particular attention to this when using revolving
pedestal!
3.4 Ceiling
If the ceiling above the fireplace is made of a combustible
material, the minimum distance between the fireplace and
ceiling must be 1000 mm.
ENGLISH
Produktspezifikationen
Marke: | Jøtul |
Kategorie: | Heizung |
Modell: | F 473 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Jøtul F 473 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Heizung Jøtul
10 April 2024
6 März 2024
1 März 2024
27 Januar 2024
8 Dezember 2023
16 November 2022
Bedienungsanleitung Heizung
- Heizung Aduro
- Heizung AFK
- Heizung Infiniton
- Heizung Clatronic
- Heizung Domo
- Heizung Emerio
- Heizung Tristar
- Heizung Nedis
- Heizung SilverCrest
- Heizung Profile
- Heizung Quigg
- Heizung Adler
- Heizung Camry
- Heizung Guzzanti
- Heizung Trisa
- Heizung Bosch
- Heizung Vonroc
- Heizung AEG
- Heizung Ardes
- Heizung Bauknecht
- Heizung Concept
- Heizung Electrolux
- Heizung Fagor
- Heizung Jata
- Heizung Klarstein
- Heizung Solis
- Heizung Bomann
- Heizung H.Koenig
- Heizung Melissa
- Heizung Steba
- Heizung Taurus
- Heizung Tefal
- Heizung Cresta
- Heizung Thomson
- Heizung Black And Decker
- Heizung Trotec
- Heizung Blaupunkt
- Heizung Eldom
- Heizung Koenig
- Heizung Prime3
- Heizung Solac
- Heizung Wilfa
- Heizung Eureka
- Heizung Candy
- Heizung DeWalt
- Heizung Einhell
- Heizung Midea
- Heizung NABO
- Heizung Svan
- Heizung King
- Heizung Pelgrim
- Heizung Philco
- Heizung Eurom
- Heizung Elro
- Heizung Olympia
- Heizung Orion
- Heizung Livoo
- Heizung Stanley
- Heizung Easy Home
- Heizung Tectro
- Heizung Güde
- Heizung Perel
- Heizung Bimar
- Heizung Stadler Form
- Heizung Rowenta
- Heizung DeLonghi
- Heizung Reer
- Heizung Maxwell
- Heizung Fakir
- Heizung Kalorik
- Heizung Rotel
- Heizung Scarlett
- Heizung Cecotec
- Heizung Zephir
- Heizung Vaillant
- Heizung Qlima
- Heizung Haverland
- Heizung Honeywell
- Heizung Remko
- Heizung Suntec
- Heizung Zibro
- Heizung Dedra
- Heizung MPM
- Heizung ROWI
- Heizung Imetec
- Heizung Team
- Heizung Burley
- Heizung Remeha
- Heizung Stiebel Eltron
- Heizung Truma
- Heizung Toolland
- Heizung Heller
- Heizung Proline
- Heizung Dimplex
- Heizung Sonnenkönig
- Heizung Noirot
- Heizung Aktobis
- Heizung Toyotomi
- Heizung CasaFan
- Heizung Baxi
- Heizung Tesy
- Heizung Tepro
- Heizung EWT
- Heizung Kogan
- Heizung Innoliving
- Heizung Argo
- Heizung Casaya
- Heizung Master
- Heizung Dovre
- Heizung Invicta
- Heizung Olimpia Splendid
- Heizung Sygonix
- Heizung Vitek
- Heizung AKO
- Heizung Danby
- Heizung Danfoss
- Heizung Kent
- Heizung Real Flame
- Heizung Hark
- Heizung Ferroli
- Heizung Zibro Kamin
- Heizung Blumfeldt
- Heizung Wamsler
- Heizung Trumatic
- Heizung Sun Joe
- Heizung Noveen
- Heizung Swan
- Heizung Soler & Palau
- Heizung Mill
- Heizung Harvia
- Heizung Orbegozo
- Heizung Napoleon
- Heizung Dantherm
- Heizung Haas+Sohn
- Heizung Defy
- Heizung Ecoteck
- Heizung Fuave
- Heizung Handson
- Heizung Heatstrip
- Heizung Jocel
- Heizung Justus
- Heizung Kago
- Heizung Kenmore
- Heizung Nefit
- Heizung Nefit-Bosch
- Heizung Nobo
- Heizung Solamagic
- Heizung Grunkel
- Heizung Vornado
- Heizung Zodiac
- Heizung WAGAN
- Heizung WestBend
- Heizung AstralPool
- Heizung Argoclima
- Heizung Lasko
- Heizung Hatco
- Heizung Cadel
- Heizung Becken
- Heizung Rinnai
- Heizung Blaze
- Heizung Hubbell
- Heizung Escea
- Heizung Ravanson
- Heizung Pacific Energy
- Heizung XPower
- Heizung Jindara
- Heizung Flama
- Heizung Brivis
- Heizung Chauvet
- Heizung Creda
- Heizung IXL
- Heizung JANDY
- Heizung Martec
- Heizung Regency
- Heizung Braemar
- Heizung HeatStar
- Heizung PAX
- Heizung Bromic
- Heizung Scandia
- Heizung Pureheat
- Heizung Sunheat
- Heizung DCS
- Heizung Quadra-Fire
- Heizung VIESTA
Neueste Bedienungsanleitung für -Kategorien-
18 April 2024
17 April 2024
17 April 2024
16 April 2024
16 April 2024
15 April 2024
15 April 2024
15 April 2024
15 April 2024
15 April 2024