JennAir JMW2430LL Bedienungsanleitung

JennAir Herde JMW2430LL

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für JennAir JMW2430LL (104 Seiten) in der Kategorie Herde. Dieser Bedienungsanleitung war für 53 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/104
FOR SERVICE TECHNICIAN’S USE ONLY
Tech Manual Do not remove or destroy
W11405739A 08/20
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
DANGER
Electrical Shock Hazard
Only authorized technicians should
perform diagnostic voltage measurements.
After performing voltage measurements,
disconnect power before servicing.
Failure to follow these instructions can
result in death or electrical shock.
Voltage Measurement Safety Information
When performing live voltage measurements, you must do the following:
■ Verify the controls are in the off position so that the appliance does not start when energized.
■ Allow enough space to perform the voltage measurements without obstructions.
■ Keep other people a safe distance away from the appliance to prevent potential injury.
■ Always use the proper testing equipment.
■ After voltage measurements, always disconnect power before servicing.
FOR SERVICE TECHNICIAN’S USE ONLY
2
IMPORTANT: Electrostatic Discharge (ESD) Sensitive Electronics
ESD problems are present erywhere ESD may damage or weaken the electronic control assemblyev . . The new control
assembly may appear to work well after repair is finished, but failure may occur at a later date due to ESD stress.
■ Use an antistatic wrist strap. Connect wrist strap to green ground connection point or unpainted metal in the
appliance
-OR-
Touch your finger repeatedly to a green ground connection point or unpainted metal in the appliance.
■ Before removing the part from its package, touch the antistatic bag to a green ground connection point or
unpainted metal in the appliance.
■ Avoid touching electronic parts or terminal contacts; handle electronic control assembly by edges only.
■ When repackaging failed electronic control assembly in antistatic bag, observe above instructions.
3
PRECAUTIONS TO BE OBSERVED BEFORE
AND DURING SERVICING TO AVOID
POSSIBLE EXPOSURE TO EXCESSIVE
MICROWAVE ENERGY
a. Do not operate or allow the oven to be operated with the door open.
b. Make the following safety checks on all ens to be serviced before activating the magnetron or other ov
micr source, and make repairs as necessary:owave
1. Interlock Operation
2. Proper Door Closing
3. Seal and Sealing Surfaces (Arcing, Wear and Other Damage)
4. Damage to or Loosening of Hinges and Latches
5. Evidence of Dropping or Abuse
c. Before turning on micr power for any service test or inspection within the micr generating owave owave
compartments, check the magnetron, waveguide or transmission line, and cavity for proper alignment,
integrity and connections.
d. Any defective or misadjusted components in the interlock, monitor, door seal, and micr owave
generation and transmission systems shall be repaired, replaced, or adjusted procedures described by
in service manual before the en is released to the owner.ov
e. A micr leakage check to rify compliance with the CSA should be performed on each en prior owave ve ov
to release to the owner.
Do not attempt to operate the en if the door glass is broken.f. ov
FOR SERVICE TECHNICIAN’S USE ONLY
4
Diagnostics
IMPORTANT: Before powering microwave (MW) magnetron, be surethat a
load, such as a microwave-safe cup of water, is present in the microwave
oven cavity.
Unplug oven or disconnect power before performing thefollowing checks:
■A potential cause of a control not functioning is corrosion on connections.
Observe connections andcheck for continuity with an ohmmeter.
■All tests/checks should be made with a VOM or DVM having a sensitivity
of 20,000 Ί per volt DC or greater.
■Check all connections before replacing components, looking for broken
or loose wires, failed terminals, or wires not pressed into connectors far
enough. Damaged harness must be entirely replaced. Do not rework a
harness.
■Resistance checks must be made with power cord unplugged from outlet
and with wiring harness or connectors disconnected.
IMPORTANT: Do not replace the control if there is no evidence of any failure.
To Enter Diagnostics Mode:
Before proceeding with any corrective action, perform the following steps to
enter the Diagnostics mode:
1. Enter Diagnostics mode by pressing LOWER OVEN>LOWER
LIGHT>OVEN CANCEL (repeat 2more times).
TIP: You can also swipe your nger from left to right overthe keypads
3times.
NOTE: You do not need to wait for any audible or visual feedback from
the control between keypad presses.
2. If control does not enter Diagnostics mode, continue repeating the
keypad sequence from Step 1. All the keypads will light up when the
control enters Diagnostics mode.
3. From the Diagnostics menu, scroll to the desired selection using the
touch screen.
Error Diagnostics: View and clear the failure history.
Component Activation: Manually activate each relay.
Sensors & Switches: View the traditional oven cavity temperatures and
door/latch switch status.
System Information: View the model number, serial number, and
software versions.
Exit Diagnostics
General Procedure: Error Codes
NOTE: All failures are stored in the failure history. To check if the error code
is still present, start a cooking function and wait 1 minute to check if the error
appears.
1. Plug in oven or connect power.
2. Enter Diagnostics mode.
3. Touch or scroll to “Error Diagnostics” in the Diagnostics menu, and then
touch “OK.”
4. To clear error codes, touch “Clear History.”
5. If no failures are listed, the message “No Error” will appear on the screen.
5
General Procedure: Component Activation
1. Plug in oven or connect power.
2. Enter Diagnostics mode.
3. Touch or scroll to “Component Activation” in the Diagnostics menu, and
then touch “OK.”
4. Touching the following selections will activate/ deactivate corresponding
relay.
Selection Relay
MW Light MW Light Relay
MW Turntable MW Turntable Relay
MW Cooling Fan MW Cooling Fan Relay
MW Grill MW Broil Element Relay
MW Convection Element MW Convection ElementRelay
MW Convection Fan MW Convection fan Relay
MW Magnetron/Cooling Fan MW Magnetron and MWCooling Fan
Relay
Oven Bake Element Oven Bake Element Relay
Oven Broil Element Oven Broil Element Relay
Oven Convection Element Oven Convection ElementRelay
Oven Convection Fan Oven Convection Fan Relay
Oven Cooling FanHigh Speed Oven Cooling Fan High-SpeedRelay
Oven Cooling FanLowSpeed Oven Cooling Fan Low-SpeedRelay
Oven Light Oven Light Relay
Oven Door LatchMotor Oven Door Latch Motor Relay
General Procedure: Sensors & Switches
NOTE: This procedure is to view the current status of oven switches and
sensor readings.
Display Status
MW Door Switch Open or Closed
MW Cavity Temperature Degrees in Celsius
Oven Door Switch Open or Closed
Oven Latch Switch Open or Closed
Oven Cavity Temperature Degrees in Celsius
Oven Meat Probe Temperature Degrees in Celsius
1. Plug in oven or connect power.
2. Enter Diagnostics mode.
3. Touch or scroll to “Sensors & Switches” in the Diagnostics menu, and
then touch “OK.”
4. Touch or scroll through the Sensors & Switches menu to view the desired
status.
NOTE: Touching “Back” will return the display to the main Diagnostics
menu.
FOR SERVICE TECHNICIAN’S USE ONLY
6
General Procedure: System Information
NOTE: This procedure is to view the following system information:
System Information Display
Model # Model Information
Serial # Product Serial Number
UI Serial # User Interface Serial Number
Oven ACU Serial # Appliance Control UnitSerialNumber
UI Version User Interface Software Version
HMI Central SW HMI Central Board SoftwareVersion
HMI Left SW HMI Left Keyboard SoftwareVersion
HMI Left EE HMI Left Keyboard EEPROMVersion
HMI Right SW HMI Right Keyboard SoftwareVersion
HMI Right EE HMI Right Keyboard EEPROMVersion
Kernel Version HMI Central Board SoftwareVersion
Touch Calibration Version LCD/TP FPC Tail SoftwareVersion
Database Version HMI Central Board DatabaseStructure
Audio Version HMI Central Board SoftwareVersion
Oven ACU SW Oven Appliance Control UnitSoftware
Version
MWO ACU SW Microwave Oven Appliance Control
Unit Software Version
Diagnostics Entries Number of times Diagnostics menu has
been entered.
1. Plug in oven or connect power.
2. Enter Diagnostics mode.
3. Touch or scroll to “System Information” in the Diagnostics menu, and
then touch “OK.”
4. Touch or scroll through the System Information menu to view the desired
status.
NOTE: Touching “Back” will return the display to the main Diagnostics
menu.
General Procedure: Model Selection
NOTE: When a new User Interface (UI) is installed, you will beprompted to
select a new model number upon power-up. To change the model number on
an existing UI,follow the steps below.
1. Plug in oven or connect power.
2. Enter Diagnostics mode.
3. Touch or scroll to “System Information” in theDiagnostics menu, and
then touch “OK.”
4. Touch or scroll to “Model Number,” and then touch“OK.”
5. Touch or scroll to the correct model number inthelist, and then touch
“Select.”
7
Failure/Error Display Codes
No Display - control is blank Switch Mode Power Supply (SMPS), User
Interface (UI)
SUGGESTED CORRECTIVE ACTION PROCEDURE
NOTE: Before starting any test, cycle power to the oven(power off, wait
10seconds, and power on).
1. Unplug oven or disconnect power.
2. Remove plastic cover from UI. Check connection from display to UI.
3. Check wiring from main line to SMPS (CONN 7).
4. Check connection from wiring harness to UI (J15).
5. Check proper voltage input at J15-2 (GND) to J15-4 (14 VDC) on the UI
by completing the following steps.
6. Connect voltage measurement equipment to J15-2 and J15-4 on UI.
7. Plug in oven or reconnect power.
8. Measure voltage and conrm voltage reading is 14VDC. If voltage is
correct, unplug oven or disconnect power and go to Step 13. If voltage
isnotcorrect, go to Step 9.
9. Unplug oven or disconnect power. Replace theSMPS.
10. Reassemble all parts and panels before operating.
11. Plug in oven or reconnect power.
12. Check for control board display. If still no display, unplug oven or
disconnect power.
13. Replace HMI-Central/UI board.
14. Reassemble all parts and panels before operating.
15. Plug in oven or reconnect power. If the UI was replaced, follow the on-
screen prompts to select themodel number.
16. Verify operation is normal. If problem persists, replacethe Control Panel
Assembly and repeat steps14 through 16.
N L
2 L1
P1
1 2 3 4 5
WH
BK
BU
BR
YL
Oven
Appliance
Manager
User Interface
Microwave
Appliance
Manager
P26
OR
1 2 3 4 5
1 2 3 4
1
2
1
1
3
2
24
5
6
1
3
2
4
WH
P1
J8
BK
YL
BR OR
J5
J15
J7 HMI RightHMI Left J4J6
SMPS
14 V DC
15W
CONN2
CONN7
BK
WH OR
YLOR
52 BU
Cavity
Thermostat
42 H W
Line
20A Fuse
P34 41 H W
Line
Filter
P33
L1
P31
P32
Control Panel Assembly
FOR SERVICE TECHNICIAN’S USE ONLY
8
User Interface not reacting
to touch Control Panel Assembly
SUGGESTED CORRECTIVE ACTION PROCEDURE
NOTE: Before starting any test, cycle power to the oven(power off, wait
10seconds, and power on).
1. Enter the Diagnostics menu, and then touch POWER.
2. To reset Touch Calibration: unplug oven or disconnect power, wait
10seconds, and then pluginoven or reconnect power. If still no
response, go to Step 3.
3. Unplug oven or disconnect power.
4. Replace Control Panel Assembly.
5. Reassemble all parts and panels before operating.
6. Plug in oven or reconnect power.
7. Verify operation is normal.
No Sound Speaker, Control Panel Assembly
SUGGESTED CORRECTIVE ACTION PROCEDURE
NOTE: Before starting any test, cycle power to the oven(power off, wait
10seconds, and power on).
1. Verify sound is enabled. Touch the Tools menu, and then scroll to the
Sound menu. Conrm Key Press, Timer & Alert, and Power On & Off
actions are all turned on and set to the desired volume.
2. Unplug oven or disconnect power.
3. Conrm the speaker is rmly connected to the HMI-Central/UI board at
J8. If speaker is rmly connected, go to Step 4. If speaker connection
isloose, reconnect and proceed to Step 5.
4. Replace speaker.
5. Reassemble all parts and panels before operating.
6. Plug in oven or reconnect power.
7. Conrm operation of the speaker. If problem persists, unplug oven or
disconnect power, replace Control Panel Assembly, and repeat steps 5
through 7.
HMI-C
User Interface
Speaker
BK
RD 1
2J8
9
FAILURE ERROR LIKELY FAILURE CONDITION
F1
Internal E0 Oven user interface failure
SUGGESTED CORRECTIVE ACTION PROCEDURE
NOTE: Before starting any test, cycle power to the oven(power off, wait
10seconds, and power on).
PROCEDURE: Before proceeding, verify the error codeby entering the
Diagnostics mode and selecting “Error Diagnostics.”
NOTE: If other error codes are stored, troubleshoot those other error codes
rst.
1. Unplug oven or disconnect power.
2. Conrm the control panel assembly is grounded to the oven chassis. If it
is, go to Step 6. If it is not, x the connection.
3. Reassemble all parts and panels before operating.
4. Plug in oven or reconnect power and cycle power.
5. If error persists unplug oven or disconnect power.
6. Replace HMI-Central/UI board.
7. Reassemble all parts and panels before operating.
8. Plug in oven or reconnect power and cycle power.
9. If error persists after HMI-Central/UI board is replaced, unplug oven or
disconnect power and replace Control Panel Assembly.
10. Reassemble all parts and panels before operating.
11. Plug in oven or reconnect power. Follow the on-screen prompts for model
selection.
12. Verify operation is normal. Enter Diagnostics mode, select “Error
Diagnostics,” and clear the history. If the Control Panel Assembly was
replaced, there is noneed to clear the error history.
FAILURE ERROR LIKELY FAILURE CONDITION
F1 E1 Internal oven ACU error
SUGGESTED CORRECTIVE ACTION PROCEDURE
NOTE: Before starting any test, cycle power to the oven(power off, wait
10 seconds, and power on).
PROCEDURE: Before proceeding, verify the error codeby entering the
Diagnostics mode and selecting “Error Diagnostics.”
NOTE: If other error codes are stored, troubleshoot those other error codes
rst.
1. Unplug oven or disconnect power.
2. Replace the Copernicus Appliance Manager.
3. Reassemble all parts and panels before operating.
4. Plug in oven or reconnect power.
5. If error persists after Copernicus Appliance Manager is replaced, unplug
oven or disconnect power, and then go to Step 6. If not, go to Step 9.
6. Replace Control Panel Assembly.
7. Reassemble parts and panels before operating.
8. Plug in oven or reconnect power.
9. Follow the on-screen prompts to select the modelnumber
10. Verify operation is normal. Enter Diagnostics mode, select “Error
Diagnostics,” and clear the history. If the Control Panel Assembly was
replaced, there is noneed to clear the error history.
FOR SERVICE TECHNICIAN’S USE ONLY
10
FAILURE ERROR LIKELY FAILURE CONDITION
F1 E4 Microwave oven relay4903error
SUGGESTED CORRECTIVE ACTION PROCEDURE
NOTE: Before starting any test, cycle power to the oven (power off, wait
10 seconds, and power on). After powering on, be sure that a load, such as
a microwave-safe cup of water, is present in the microwave oven cavity, and
start a microwave cooking function. Wait 1minute, and then verify that the
failure happens again.
1. Make sure that all interlock switches work properly: when door is open,
microwave light is on; when dooris closed, microwave light is off.
2. Unplug oven or disconnect power.
3. Check the following on the Microwave ApplianceManager:
a. Wire connections to Relay 4903
b. Check if Relay 4903 is shorted. If so then gotoStep 7.
4. Reassemble all parts and panels before operating.
5. Plug in oven or reconnect power.
6. To check if the error code is still present, be sure that a load, such as a
microwave-safe cup of water, is present in the microwave oven cavity,
and start a cooking function in the microwave oven. Wait 1minute to
check if the error appears. If error remains, go to Step 7. If not, go to Step
10.
7. Unplug oven or disconnect power and replace the Microwave Appliance
Manager.
8. Reassemble all parts and panels before operating.
9. Plug in oven or reconnect power.
10. Verify operation is normal. Enter the Diagnostics menu, select “Error
Diagnostics,” and clear thehistory.
FAILURE ERROR LIKELY FAILURE CONDITION
F1 E5 Microwave oven inverter error
SUGGESTED CORRECTIVE ACTION PROCEDURE
NOTE: Before starting any test, cycle power to the oven (power off, wait
10seconds, and power on). After powering on, be sure that a load, such as
a microwave-safe cup of water, is present in the microwave oven cavity, and
start a microwave cooking function. Wait 1minute, and then verify that the
failure happens again.
1. Make sure that all interlock switches work properly: when door is open,
microwave light is on; when dooris closed, microwave light is off.
2. Unplug oven or disconnect power.
3. Check the following on the Microwave ApplianceManager:
a. Relay 4903
b. Connector P8
4. Check the following connections on the Inverterboard:
a. CN701
b. CN702
c. CN703
5. If the door works properly and all connections areokay, replace the
Microwave Inverter Board.
6. Reassemble all parts and panels before operating.
7. Plug in oven or reconnect power.
Line Fuse
20A
Primary
Interlock
Switch
In ervert
Micr Relayowave
4903
1
4
BR BU
CN702
L1
Magnetron
MW In rterve
PWM
To
MW
Relay
4903
P8
P354
WH
BU
12 3
CN701
E701
CN703
CN702
RD RD
YL/
GN
32 1
P355
11
8. To check if the error code is still present, be sure that a load, such as a
microwave-safe cup of water, is present in the microwave oven cavity,
and start a cooking function in the microwave oven. Wait 1minute to
check if the error appears. If error remains, then go to Step 9. If not, go to
Step 17.
9. Unplug oven or disconnect power.
10. Replace the Magnetron.
11. Reassemble all parts and panels before operating.
12. Plug in oven or reconnect power.
13. To check if the error code is still present, be sure that a load, such as a
microwave-safe cup of water, is present in the microwave oven cavity,
and start a cooking function in the microwave oven. Wait 1minute to
check if the error appears. If error remains, then go to Step 14. If not, go
to Step 17.
14. Unplug oven or disconnect power and replace theMicrowave ACU.
15. Reassemble all parts and panels before operating.
16. Plug in oven or reconnect power.
17. Verify operation is normal. Enter the Diagnostics menu, select “Error
Diagnostics,” and clear thehistory.
FAILURE ERROR LIKELY FAILURE CONDITION
F1 E6 Microwave generation error
SUGGESTED CORRECTIVE ACTION PROCEDURE
NOTE: Before starting any test, cycle power to the oven (power off, wait
10seconds, and power on). After powering on, be sure that a load, such as
a microwave-safe cup of water, is present in the microwave oven cavity, and
start a microwave cooking function. Wait 1minute, and then verify that the
failure happens again.
1. Make sure that all interlock switches work properly: when door is open,
microwave light is on; when dooris closed, microwave light is off.
2. Unplug oven or disconnect power.
3. Check the following on the Microwave ApplianceManager:
a. Relay 4903
4. If the door works properly and all connections areokay, replace the
Magnetron.
5. Reassemble all parts and panels before operating.
6. Plug in oven or reconnect power.
7. To check if the error code is still present, be sure that a load, such as a
microwave-safe cup of water, is present in the microwave oven cavity,
and start a cooking function in the microwave oven. Wait 1minute to
check if the error appears. If error remains, then go to Step 8. If not, go to
Step 16.
8. Unplug oven or disconnect power and replace theInverter Board.
9. Reassemble all parts and panels before operating.
10. Plug in oven or reconnect power.
11. To check if the error code is still present, be sure that a load, such as a
microwave-safe cup of water, is present in the microwave oven cavity,
and start a cooking function in the microwave oven. Wait 1minute to
check if the error appears. If error remains, then go to Step 12. If not, go
to Step 16.
12. Unplug oven or disconnect power.
13. Replace the Microwave ACU.
14. Reassemble all parts and panels before operating.
Line Fuse
20A
Primary
Interlock
Switch
In ervert
Micr Relayowave
4903
1
4
BR BU
CN702
L1
FOR SERVICE TECHNICIAN’S USE ONLY
12
15. Plug in oven or reconnect power.
16. Verify operation is normal. Enter the Diagnostics menu, select “Error
Diagnostics,” and clear thehistory.
FAILURE ERROR LIKELY FAILURE CONDITION
F2
Keypad
E0 Keypad disconnected
E1 Stuck/Shorted keypad
SUGGESTED CORRECTIVE ACTION PROCEDURE
NOTE: Before starting any test, cycle power to the oven(power off, wait
10seconds, and power on).
PROCEDURE: Before proceeding, verify the error codeby entering the
Diagnostics mode and selecting “Error Diagnostics.”
1. Unplug oven or disconnect power.
2. Check that connectors J4, J5, J6, and J7 are rmly connected. If they are
not, go to Step 3. If they are, go to Step 6.
3. Reconnect any loose connectors.
4. Reassemble all parts and panels before operating.
5. Plug in oven or reconnect power. If the failure is gone, go to Step 9. If the
failure is still present, unplug oven or disconnect power.
6. Replace the Control Panel Assembly.
7. Reassemble all parts and panels before operating.
8. Follow the on-screen prompts to select the model number.
9. Verify operation is normal. Enter the Diagnostics menu, select “Error
Diagnostics,” and clear the history. If the Control Panel Assembly was
replaced, there is no need to clear the error history.
HMI Right
J7J5
J15
User Interface
J4J6
HMI Left
1234 Control Panel Assembly
RD
BK
Speaker
J8
2 1
13
FAILURE ERROR LIKELY FAILURE CONDITION
F3
Sensors E0 Main oven sensor openorshorted
SUGGESTED CORRECTIVE ACTION PROCEDURE
NOTE: Before starting any test, cycle power to the oven(power off, wait
10seconds, and power on).
PROCEDURE: Before proceeding, verify the error codeby entering the
Diagnostics mode and selecting “Error Diagnostics.”
1. Unplug oven or disconnect power.
2. Disconnect connector P3 from Oven Appliance Manager, and measure
the resistance of the sensor between P3-1 and P3-2. Test for 1000 Ί to
1200 Ω at77°F (25°C). Check sensor for short to ground. If checks on
sensor are not correct, replace sensor andrepeat the checks.
3. Reassemble all parts and panels and plug in oven orreconnect power.
4. Enter Diagnostics mode and select “Sensors & Switches” to verify if the
temperature shown in the Cavity Temperature display is correct (ambient
temperature). If it is, go to Step 8. If not, unplug oven or disconnect
power.
NOTE: On the status screen, the unit of measurement is Celsius.
5. Replace the Copernicus Appliance Manager board.
6. Reassemble all parts and panels before operating.
7. Plug in oven or reconnect power.
8. Verify operation is normal. Enter Diagnostics mode, select “Error
Diagnostics,” and clear the history.
FAILURE ERROR LIKELY FAILURE CONDITION
F3
Sensors E3 Meat probe connector jack ormeat probe
shorted
SUGGESTED CORRECTIVE ACTION PROCEDURE
NOTE: Before starting any test, cycle power to the oven(power off, wait
10seconds, and power on).
PROCEDURE: Before proceeding, verify the error codeby entering the
Diagnostics mode and selecting “Error Diagnostics.”
1. Unplug oven or disconnect power.
2. Remove meat probe if connected.
3. Disconnect connector P3 from Copernicus ApplianceManager.
4. Check connector jack resistance between P3-3 and P3-4. If it is 0 Ί,
change the jack assembly, and then go to Step 5.
If it is not 0 Ί, the jack assembly is working properly. Go to Step 5.
5. Plug in the meat probe and check for short to ground or open. If checks
on meat probe are not correct, replace the meat probe. At 77°F (25°C) the
expected value is approximately 50 KΊ. If they are correct, replace the
Copernicus Appliance Manager.
6. Reassemble all parts and panels before operating.
7. Plug in oven or reconnect power.
8. Verify operation is normal. Enter Diagnostics mode, select “Error
Diagnostics,” and clear the history. Check the meat probe reading by
entering Diagnostics mode and selecting “Sensors & Switches.” The meat
probe should detect the ambient temperature.
Copernicus
Appliance Manager
Oven
T
emperature
Sensor
V
V1
2
3
4
5
6
7
8
9
10
P3
Copernicus
Appliance Manager
Meat Probe
Sensor
OR
GN
1
2
3
4
5
6
7
8
9
10
P3
FOR SERVICE TECHNICIAN’S USE ONLY
14
FAILURE ERROR LIKELY FAILURE CONDITION
F4 E1 Microwave cavity temperaturesensor error
SUGGESTED CORRECTIVE ACTION PROCEDURE
NOTE: Before starting any test, cycle power to the oven (power off, wait
10seconds, and power on). After powering on, be sure that a load, such as
a microwave-safe cup of water, is present in the microwave oven cavity, and
start a microwave cooking function that uses the temperature sensor, such as
a Convect cycle. Wait 1minute, and then verify that the failure happens again.
1. Unplug oven or disconnect power.
2. Check that the P22 connection of the Microwave Appliance Manager is
rmly connected. If it is, go to Step 3. If it is not, reconnect and go to
Step 5.
3. Disconnect connector P22 from the Microwave Appliance Manager, and
measure the resistance of the thermistor. It should be (approximately)
230kΩ at77°F ± 10°F (25°C ± 10°C).
4. Check thermistor for short to ground. If check on thermistor is not
correct, replace the thermistor. If thermistor check is correct, replace the
Microwave Appliance Manager.
5. Reassemble all parts and panels before operating.
6. Plug in oven or reconnect power.
7. Verify operation is normal. Enter the Diagnostics menu, select “Error
Diagnostics,” and clear the history.
FAILURE ERROR LIKELY FAILURE CONDITION
F4 E2 Magnetron temperature sensorerror
SUGGESTED CORRECTIVE ACTION PROCEDURE
NOTE: Before starting any test, cycle power to the oven (power off, wait
10seconds, and power on). After powering on, be sure that a load, such as
a microwave-safe cup of water, is present in the microwave oven cavity, and
start a microwave cooking function. Wait 1minute, and then verify that the
failure happens again.
1. Unplug oven or disconnect power.
2. Check that the P21 connection of the Microwave Appliance Manager is
rmly connected. If it is, go to Step 3. If it is not, reconnect and go to
Step 5.
3. Disconnect connector P21 from the Microwave Appliance Manager, and
measure the resistance of the thermistor. It should be (approximately)
10kΩ at77°F ± 10°F (25°C ± 10°C).
4. Check thermistor for short to ground. If check on thermistor is not
correct, replace the thermistor. If thermistor check is correct, replace the
Microwave Appliance Manager.
5. Reassemble all parts and panels before operating.
6. Plug in oven or reconnect power.
7. Verify operation is normal. Enter the Diagnostics menu, select “Error
Diagnostics,” and clear the history.
P22
vity
mistor
Appliance
Manager
P21
Microwave
Appliance
Manager
Magnetron
Ther
mistor
15
FAILURE ERROR LIKELY FAILURE CONDITION
F4 Inputs E4 Microwave oven humiditysensor error
SUGGESTED CORRECTIVE ACTION PROCEDURE
NOTE: Before starting any test, cycle power to the oven (power off, wait
10seconds, and power on). After powering on, be sure that a load, such as
a microwave-safe cup of water, is present in the microwave oven cavity, and
start a microwave cooking function that uses the humidity sensor, such as a
Steam cycle. Wait 1minute, and then verify that the failure happens again.
1. Unplug oven or disconnect power.
2. Check that the P23 connection of the Microwave Appliance Manager is
rmly connected. If it is, go toStep 3. If it is not, reconnect and go to
Step 5.
3. Disconnect connector P23 from Microwave Appliance Manager and
measure the resistance ofthe sensor:
Between pins 3 and 1. It should be approximately 2800 Ί at 77°F ¹ 10°F
(25°C ¹ 10°C).
Between pins 3 and 2. It should be approximately 2800 Ί at 77°F ¹ 10°F
(25°C ¹ 10°C).
4. Check sensor for short to ground. If checks on sensor are not correct,
replace the sensor. If sensor checks are correct, replace the Microwave
Appliance Manager.
5. Reassemble all parts and panels before operating.
6. Plug in oven or reconnect power.
7. Verify operation is normal. Enter the Diagnostics menu, select “Error
Diagnostics,” and clear the history.
FAILURE ERROR LIKELY FAILURE CONDITION
F4 E8 Inverter over temperature
SUGGESTED CORRECTIVE ACTION PROCEDURE
NOTE: Before starting any test, cycle power to the oven (power off, wait
10seconds, and power on). After powering on, be sure that a load, such as
a microwave-safe cup of water, is present in the microwave oven cavity, and
start a microwave cooking function. Wait 1minute, and then verify that the
failure happens again.
1. Unplug oven or disconnect power.
2. Check the following:
a. Cooling fan connection for any loose connectors
b. Oven installation and make sure there is no air blockage
3. Reassemble all parts and panels before operating.
4. Plug in oven or reconnect power.
5. To check if the cooling fan is stalled, be sure that a load, such as a
microwave-safe cup of water, is present in the microwave oven cavity,
and start a cooking function in the microwave oven. Make sure the fan is
running. If it is not, unplug oven or disconnect power, replace the fan, and
go to Step 8. Otherwise, go to Step 6.
6. Unplug oven or disconnect power.
7. Replace the inverter board.
8. Reassemble all parts and panels before operating.
9. Plug in oven or reconnect power.
10. Verify operation is normal. Enter the Diagnostics menu, select “Error
Diagnostics,” and clear the history.
Micr eowav
Appliance
Manager
Humidity
Sensor
1600
P23
FOR SERVICE TECHNICIAN’S USE ONLY
16
FAILURE ERROR LIKELY FAILURE CONDITION
F4 E9 Inverter and magnetron overtemperature
SUGGESTED CORRECTIVE ACTION PROCEDURE
NOTE: Before starting any test, cycle power to the oven (power off, wait
10seconds, and power on). After powering on, be sure that a load, such as
a microwave-safe cup of water, is present in the microwave oven cavity, and
start a microwave cooking function. Wait 1minute, and then verify that the
failure happens again.
1. Unplug oven or disconnect power.
2. Check the following:
a. Cooling fan connection for any loose connectors
b. Oven installation and make sure there is no air blockage
3. Reassemble all parts and panels before operating.
4. Plug in oven or reconnect power.
5. To check if the cooling fan is stalled, be sure that a load, such as a
microwave-safe cup of water, is present in the microwave oven cavity,
and start a cooking function in the microwave oven. Make sure the fan is
running. If it is not, unplug oven or disconnect power, replace the fan, and
go to Step 8. Otherwise, go to Step 6.
6. Unplug oven or disconnect power.
7. Replace the Magnetron and the inverter board.
8. Reassemble all parts and panels before operating.
9. Plug in oven or reconnect power.
10. Verify operation is normal. Enter the Diagnostics menu, select “Error
Diagnostics,” and clear the history.
FAILURE ERROR LIKELY FAILURE CONDITION
F5 Inputs E0 Door and latch switch donotagree
SUGGESTED CORRECTIVE ACTION PROCEDURE
NOTE: Before starting any test, cycle power to the oven(power off, wait
10seconds, and power on).
PROCEDURE: Before proceeding, verify the error codeby entering the
Diagnostics mode and selecting “Error Diagnostics.”
1. Enter the Diagnostics menu and select “Component Activation.” Touch or
scroll to “Door Latch Motor,” and then touch “OK.” Touch “Latch Door.”
Wait at least 15 seconds, and then check if latch status changes on
screen. If status does not change, unplug oven or disconnect power and
go to Step 2. If status changes, unplug oven or disconnect power and go
to Step 5.
2. If the oven door did not unlatch, unplug connector P3 and check for
continuity (on the latch wire) between P3-5 and P3-7.
3. Disconnect J8 connector from Copernicus Appliance Manager.
Copernicus
Appliance Manager
Motor Latch Switch
Door Switch
P3
BU TN
BR
OR/BK
1
2
3
4
5
6
7
8
9
10
17
4. Measure the resistance between connectors J8-2 and P5-1. It should be
500 Ί to 3000 Ί at 77°F (25°C).
5. If the resistance check is outside the range, replace the affected door
latch assembly. Verify that the error is gone.
6. Reassemble all parts and panels.
7. Plug in oven or reconnect power.
8. Enter the Diagnostics menu and select “Component Activation.” Check
the door status on the screen by opening and closing the oven door.
9. If status does not change, unplug the oven or disconnect power.
10. Check for continuity with door open and closed at P3-5 to P3-6. Door
open = innite resistance. Door closed = zero resistance.
11. If continuity check is not correct, replace the door latch assembly. If all
checks were correct, replace Copernicus Appliance Manager.
12. Reassemble all parts and panels before operating.
13. Plug in oven or reconnect power.
14. Verify operation is normal. Enter the Diagnostics menu, select “Error
Diagnostics,” and clear the history.
FAILURE ERROR LIKELY FAILURE CONDITION
F5 Inputs E1 Latch not operating
SUGGESTED CORRECTIVE ACTION PROCEDURE
NOTE: Before starting any test, cycle power to the oven(power off, wait
10seconds, and power on).
PROCEDURE: Before proceeding, verify the error codeby entering the
Diagnostics mode and selecting “Error Diagnostics.”
1. Enter the Diagnostics menu and select “Component Activation.” Touch or
scroll to “Door Latch Motor,” and then touch “OK.” Touch “Latch Door.”
Wait at least 15 seconds, and then check if latch status changes on
screen. If status does not change, go to Step 2. If status changes, unplug
oven or disconnect power, replace Copernicus Appliance Manager and
go to Step 6.
2. If latch status on screen is “open” unplug oven ordisconnect power and
check for loose harness connection between motor latch switch and P3-5
andP3-7.
3. Disconnect connector J8 from Copernicus ApplianceManager.
Copernicus
Appliance Manager
P5
J8
YL
WH
WH
N
Motor Door Latch
1
2
3
4
5
6
7
1
2
Copernicus
Appliance Manager
Motor Latch Switch
Door Switch
P3
BU TN
BR
OR/BK
1
2
3
4
5
6
7
8
9
10
FOR SERVICE TECHNICIAN’S USE ONLY
18
4. Measure the resistance between connectors J8-2 and P5-1. It should be
500 Ί to 3000 Ί at 77°F (25°C).
5. If the resistance check is outside the range, replace the door latch
assembly. Verify that the error is gone. If all checks were correct, replace
Copernicus Appliance Manager.
6. Reassemble all parts and panels before operating.
7. Plug in oven or reconnect power.
8. Verify operation is normal. Enter the Diagnostics menu, select “Error
Diagnostics,” and clear the history.
FAILURE ERROR LIKELY FAILURE CONDITION
F6
E0 Oven user interface - lostcommunication
E6 Oven appliance manager - lostcommunication
SUGGESTED CORRECTIVE ACTION PROCEDURE
NOTE: Before starting any test, cycle power to the oven(power off, wait
10seconds, and power on).
PROCEDURE: Before proceeding, verify the error codeby entering the
Diagnostics mode and selecting “Error Diagnostics.”
1. Unplug oven or disconnect power.
2. Check continuity of wirings between P1-4 and J15-3, then P1-5 and
J15-2.
3. Check for continuity between P1-1 and P1-2.
4. If all checks are correct, replace Copernicus Appliance Manager.
5. Reassemble all parts and panels before operating.
6. Plug in oven or reconnect power.
7. If the error appears again, unplug oven or disconnectpower.
8. Replace the HMI-Central/UI board.
9. Reassemble all parts and panels before operating.
10. Plug in oven or reconnect power.
11. Follow the on-screen prompts to select the model number if the UI was
replaced.
12. Verify operation is normal. Enter Diagnostics mode, select “Error
Diagnostics,” and clear the history.
Copernicus
Appliance Manager
P5
J8
YL
WH
WH
N
Motor Door Latch
1
2
3
4
5
6
7
1
2
YL
YL
BU
N L
2 L1
1
2
3
4
WH
BK
OR
OR
BR P1
Oven Appliance
Manager
SMPS
14V DC
15 W
CONN2
CONN7
HMI Right
J7J5
J15
User Interface
J4J6
HMI Left
6
5
1
2
1 2 3 4 5
1 2 3 4 Control nel Assem yPa bl
19
FAILURE ERROR LIKELY FAILURE CONDITION
F6 E1 Over temperature
SUGGESTED CORRECTIVE ACTION PROCEDURE
NOTE: Before starting any test, cycle power to the oven(power off, wait
10seconds, and power on).
PROCEDURE: Before proceeding, verify the error codeby entering the
Diagnostics mode and selecting “Error Diagnostics.”
1. Unplug oven or disconnect power.
2. Check for elements shorted to ground. Checkresistance of elements:
a. PX4-2 and PX3-2 to check Broil element (13.2 Ωto 14.6 Ω)
b. PX1-1 and PX3-2 to check Bake element (19 Ωto21 Ω)
c. PX1-3 and PX3-2 to check Upper Convect element (15.2 Ί to 17.3 Ί)
3. If any element is shorted to ground, replace theelement.
4. Check for shorted relays.
For Core Models: Disconnect PX1 and PX4 connectors
andcheckforshorts between:
a. PX1-1 and PX1-2 (Bake relay)
b. PX1-3 and PX1-4 (Up Convect relay)
c. PX4-1 and PX4-2 (Broil relay)
5. If there is a shorted relay, replace the Copernicus Appliance Manager
control. Go to Step 9.
6. If everything is correct, disconnect connector P3 from the Copernicus
Appliance Manager.
7. Measure the resistance of the oven sensor. It should be 1000 Ω to1200 Ω
at 77°F (25°C).
8. Check sensor for short to ground. If checks on sensor are not correct,
replace the sensor and repeat the checks.
9. Reassemble all parts and panels before operating.
10. Plug in oven or reconnect power.
11. Enter the Diagnostics menu and select “Sensors & Switches” to verify
that the corresponding oven temperature displayed is correct (ambient
temperature). If not, unplug oven or disconnect power, and replace the
Copernicus Appliance Manager board.
NOTE: On the status screen, the unit of measurementis Celsius.
12. Reassemble all parts and panels before operating.
13. Plug in oven or reconnect power.
14. Verify operation is normal. Enter Diagnostics mode, select “Error
Diagnostics,” and clear the history.
K11
K10
K2
K3
PX4
PX1
PX3
Copernicus Appliance Manager
BU
BU
RD
YL YL
BU
RD
RD RD
BK
BK
Broil - 4000W
Bake - 2800W
Convect - 3200W
Thermal Limiter
Oven Temperature 338°F (170°C)
RD/WH
N L2 L1
1
2
1
2
3
4
1
2
Copernicus
Appliance Manager
Oven
T
emperature
Sensor
V
V1
2
3
4
5
6
7
8
9
10
P3
FOR SERVICE TECHNICIAN’S USE ONLY
20
FAILURE ERROR LIKELY FAILURE CONDITION
F6 E4 User interface/Appliance manager state status
mismatch
SUGGESTED CORRECTIVE ACTION PROCEDURE
NOTE: Before starting any test, cycle power to the oven(power off, wait
10seconds, and power on).
PROCEDURE: Before proceeding, verify the error codeby entering the
Diagnostics mode and selecting “Error Diagnostics.”
NOTE: If other error codes are stored, troubleshoot those other error codes
rst.
1. Unplug oven or disconnect power.
2. Replace Copernicus Appliance Manager.
3. Reassemble all parts and panels before operating.
4. Plug in oven or reconnect power.
5. Cycle power. If error persists after the Copernicus Appliance Manager is
replaced, unplug oven or disconnect power. Go to Step 7.
6. If the error is gone, go to Step 10.
7. Replace the HMI-Central/UI board.
8. Reassemble parts and panels before operating.
9. Plug in oven or reconnect power, and follow the
on-screen prompts for model selection.
10. Verify operation is normal. If operation is normal, goto Step 14. If error
still exists, go to Step 11.
11. Unplug oven or disconnect power.
12. Replace the control panel assembly.
13. Plug in oven or reconnect power.
14. Follow the on-screen prompts for model selection.
15. Verify operation is normal. Enter Diagnostics mode, select “Error
Diagnostics,” and clear the history.
FAILURE ERROR LIKELY FAILURE CONDITION
F6 E8 Lost communications with microwave oven
appliance manager
SUGGESTED CORRECTIVE ACTION PROCEDURE
NOTE: Before starting any test, cycle power to the oven(power off, wait
10seconds, and power on).
PROCEDURE: Before proceeding, verify the error codeby entering the
Diagnostics mode and selecting “Error Diagnostics.”
1. Make sure the oven is plugged in. Open microwave door to check if light
comes on.
2. Ensure the Sabbath mode is disabled.
3. Unplug oven or disconnect power.
4. Check the connection between Oven User Interface Board J15-2 (yellow)
and J15-3 (orange) and Microwave Appliance Manager P26-3 (orange)
andP26-4 (yellow).
5. If harness is correct, replace the Microwave Appliance Manager.
6. Reassemble all parts and panels before operating.
7. Plug in oven or reconnect power.
8. If the error appears again, unplug or disconnect power and replace HMI-
Central/UI board.
9. Reassemble all parts and panels before operating.
10. Plug in oven or reconnect power.
User Interface
Micr eowav
Appliance Manager
P26
4321
543
21
YL
OR
J15
Wide/ wer NPo av
YL
OR
21
11. Follow the on-screen prompts to select the modelnumber if the UI was
replaced.
12. Verify operation is normal. Enter the Diagnostics menu, select “Error
Diagnostics,” and clear the history.
FAILURE
(Left-most 2
Clock digits)
ERROR
(Right-most 2
Clock digits)
LIKELY FAILURE CONDITION
F8
E0 Product not wired correctly
E1 Low fan speed overspeed
E2 High fan speed underspeed
E3 High fan speed overspeed
LOW FAN SPEED MESSAGE ON SINGLE/DOUBLE: The product
isexperiencing a problem and can no longer be used.
SUGGESTED CORRECTIVE ACTION PROCEDURE
1. Unplug oven or disconnect power.
2. Wait for at least 30 seconds.
3. Plug in oven or reconnect power.
4. Enter Diagnostics mode and navigate to the Component Activation list.
5. Turn on the Cooling Fan Low Speed.
6. Check for proper voltage input at P5-5 and neutral for high speed fan,
P5-4 and neutral for low speed fan when cooling fan should be running
by completing following steps.
7. Unplug oven or disconnect power.
8. Connect voltage measurement equipment.
9. Plug in oven or reconnect power. Measure voltage and conrm voltage
reading is 120 V. If it is not, unplug oven or disconnect power and go to
Step 13. If it is, go to Step 10.
10. Check for proper voltage input at P4-1 and P4-2 and conrm voltage
reading is 5 VDC. If it is not, unplug oven or disconnect power and go to
Step 13. If it is, go to Step 11.
11. Unplug oven or disconnect power.
12. Replace cooling fan. Go to Step 15.
13. Check integrity of all harness wires and connections between the oven
appliance manager and the cooling fan.
Ensure no shorted wires to chassis.
If the wiring is pinched or damaged, replace the cooling fan harness. Go
to Step 15.
If the wiring is good, go to Step 14.
14. Replace oven appliance manager. Go to Step 15
FOR SERVICE TECHNICIAN’S USE ONLY
22
15. Replace all parts and panels before operating.
16. Plug in oven or reconnect power.
17. Enter into Diagnostics mode and verify that fan speed is running within
oven. (High speed: 1000-3300, Low speed: 400-3000)
Once Fan Speed is completed, navigate back to the activation list and
activate the Cooling Fan High Speed and return to “More Information” screen
for fan speed.
FAILURE ERROR LIKELY FAILURE CONDITION
F9 E0 Product not wired correctly
SUGGESTED CORRECTIVE ACTION PROCEDURE
NOTE: Before starting any test, cycle power to the oven(power off, wait
10seconds, and power on).
PROCEDURE: Before proceeding, verify the error codeby entering the
Diagnostics mode and selecting “Error Diagnostics.”
1. Unplug oven or disconnect power.
2. Access the electrical wiring from the house power supply to the oven.
3. Check house wiring to the product. Check to see ifthe neutral connection
is switched with L1 or L2(refer to the installation instructions for
productwiring).
4. Reassemble all parts and panels before operating.
5. Plug in oven or reconnect power.
6. Verify operation is normal by running a cooking function. Enter
Diagnostics mode, select “Error Diagnostics,” and clear the history.
K4
K6
K7
K8 P5
YL
OR
GY
GY/BK
HS Cooling Fan
LS Cooling Fan
Convect Fan
Motor Door Latch
1
2
3
4
5
6
7
Hall Effect
Sensor
(Cooling Fan)
Copernicus
Appliance
Manager
3
2
1
P1
P2
P3 GY GY
YL
YL
GN GN
P4
23
Microwave Oven Components
Component Locations
Upper Microwave Oven
AB
C
D
EF
I
J
K
L
M
N
O
P
Q
R
S
U
V
T
H
G
A. Convect motor
B. Convect thermostat (behind cover)
C. Convect element
D. Line lter
E. Humidity sensor
F. Magnetron fan motor
G. Copernicus appliance manager (lower oven)
H. Switch mode power supply (SMPS)
I. Secondary interlock switch
J. Turntable motor
K. Broil element
L. Microwave appliance manager
M. Cavity halogen lamp
N. Primary interlock switch
O. Monitor interlock switch
P. Magnetron thermistor
Q. Magnetron
R. Microwave light transformer
S. Microwave inverter
T. Cavity temperature sensor
U. Grill thermostat
V. Cavity thermostat
Not shown: Monitor fuse, 20 A line fuse
FOR SERVICE TECHNICIAN’S USE ONLY
24
Lower Oven
A
I
J
G
H
F
B
F
C
D
E
A. HMI-Central/UI board
B. Cooling fan
C. Oven temperature sensor
D. Convection assembly
E. Temperature limiter
F. Light assembly
G. Bake element (hidden)
H. Broil element
I. Door lock assembly
J. Control panel assembly
25
Cooling Fan Relay Logic
Oven High-Speed
Blower (Main/Upper or
Lower)
Oven Low-Speed
Blower (Main/
Upper or Lower)
Oven Cooking - Cold - O
Oven Cooking - Warm - O
Oven Cooking - Hot O -
Oven Self-Clean O -
LEGEND
Cold Cavity Temperature is less than 212°F (100°C).
Warm Cavity Temperature is between 212°F and 599°F (100°C and
315°C).
Hot Cavity Temperature is greater than 599°F (315°C).
Mode Bake Broil
Convect
Ring
Convect
Fan
Convect Frozen Pizza C C C O
Convect Pastry C C C C
Convect Slow Roast 12 hrs C C C O
Convect Slow Roast 8 hrs C C C O
Convect Slow Roast 4 hrs C C C O
Convect Roast C C C O
Convect Broil - C - C
Convect Bake C C C C
Convect Bake- Rapid Preheat C C C C
Bake C C C C
Broil - C - -
Keep Warm C C - C
Rapid Proof C C - -
Proof C C - -
Self Clean C C - -
LEGEND
Relay Off Relay Cycles Relay On Not Available
- C O NA
FOR SERVICE TECHNICIAN’S USE ONLY
26
Component Testing Chart - Oven
To properly check for voltage, complete the following steps:
1. Unplug oven or disconnect power.
2. Connect voltage measurement equipment tocheckpoints.
3. Plug in oven or reconnect power and conrmvoltagereading.
4. Unplug oven or disconnect power.
Component Serviceable Side Check Points Copernicus Results-Resistance Results-Voltage
Lights Front P7-1 to L1 (J8-1) 0-40 Ί 120 V
Latch Switch Front P3-7 to P3-5 Open circuit
Door Switch Front P3-6 to P3-5 Closed circuit with oven door closed
Latch Motor Front P5-1 to N (J8-2) 500-3000 Ί 120 V motor running
Oven Temperature Sensor Front P3-1 to P3-2 1075 Ί at 68°F (20°C) DLB
Meat Probe Side P3-3 to P3-4 9876-10075 Ί
Blower Motor - HighSpeed Rear P5-5 to N (P7-1) 15-23 Ω 120 V motor running
Blower Motor - LowSpeed Rear P5-4 to N (J8-2) 15-23 Ω 120 V motor running
Thermal Limiter Rear PX3-1 to L2 (Main line) Closed circuit 0 V closed, N/A open
Convection Fan* Rear P5-3 to N (J8-2) 16-20 Ί 120 V motor running
Convection Element* Front PX1-3 to PX3-2 16.63-18.38 Ί 240 V Convection cycle
operating
Bake Element Rear PX1-1 to PX3-2 19.0-21.6 Ί 240 V Bake cycle
operating
Broil Element Front PX4-2 to PX3-2 13.5-14.92 Ί 240 V Broil cycle operating
27
Component Serviceable Side Check Points Copernicus Results-Resistance Results-Voltage
User Interface Board Front J15-2 to J15-4 N/A 14 VDC
Copernicus Appliance Manager Side (Combo) P1-2 to P1-5 N/A 14 VDC
* NOTES:
■Disconnect the harness from the board before performing measurements.
■See the following table for connector pin identication.
Copernicus Appliance Manager Harness Connector Pin Copernicus Appliance Manager Pin
PX3
Pin 1 Pin 1 Pin 1 Pin 1 PX4
PX1-4
PX1-4
PX1-3
PX1-2
PX1-1
Pin 1
Pin 1
Pin
1
Pin
1
K3 P6 P7 K11
K9 K9A
K1 K1A
K2 K2A
K10 K10A
K4
K5
K6
K7
K8
P5
J8
P1 P3 P4
Pin 1
PX1-1 J12
PX1-2 J16
PX1-3 J13
PX1-4 J17
FOR SERVICE TECHNICIAN’S USE ONLY
28
Component Testing Chart - Microwave
Component Serviceable
Side Procedure Results - Resistance Component
Location
Appliance Manager Check wiring to MW appliance manager:Top
1. Unplug microwave oven or disconnect power.
2. Visually inspect connectors on the microwave appliance
manager, P1, P2, P8, P21, P22, P23, P26, P354, P355,
and the top connectors (relays 4903, 4904, and 4905) to
see whether there are signs of overheating or any signs
of failure due to loose wires, bad crimping, etc.
3. Reassemble all parts and panels before operating.
4. Plug in microwave oven or reconnect power.
G
Cavity Thermostat Unplug microwave oven or disconnect power. Top 1.
2. Remove wire leads.
3. Measure resistance.
4. Replace wire leads.
5. Reassemble all parts and panels before operating.
6. Plug in microwave oven or reconnect power.
Normal = Continuity
Abnormal = Innite
V
Magnetron Fan
Motor
Top 1. Unplug microwave oven or disconnect power.
2. Remove wire leads.
3. Measure resistance (ohmmeter scale: Rx1).
4. Replace wire leads.
5. Reassemble all parts and panels before operating.
6. Plug in microwave oven or reconnect power.
Normal = 15 Ί
Abnormal = Innite
F
Turntable Motor Bottom Unplug microwave oven or disconnect power. 1.
2. Remove wire leads.
3. Measure resistance (ohmmeter scale: Rx1).
4. Replace wire leads.
5. Reassemble all parts and panels before operating.
6. Plug in microwave oven or reconnect power.
Normal =2500 Ί (approximately)
Abnormal = Innite
J
29
Component
Serviceable
Side Procedure Results - Resistance
Component
Location
Monitor Fuse Unplug microwave oven or disconnect power. Top 1.
2. Remove wire leads.
3. Measure resistance.
4. Replace wire leads.
5. Reassemble all parts and panels before operating.
6. Plug in microwave oven or reconnect power.
Normal = Continuity
Abnormal = Innite
Not shown
MW Light
Transformer
Top 1. Unplug microwave oven or disconnect power.
2. Remove wire leads.
3. Measure resistance (ohmmeter scale: Rx1).
4. Replace wire leads.
5. Reassemble all parts and panels before operating.
6. Plug in microwave oven or reconnect power.
Primary Winding = 40 Ί
(approximately)
Secondary Winding = 0.4 Ί
(approximately)
R
Line Fuse Unplug microwave oven or disconnect power. Top 1.
2. Remove wire leads.
3. Measure resistance.
4. Replace wire leads.
5. Reassemble all parts and panels before operating.
6. Plug in microwave oven or reconnect power.
Normal = Continuity
Abnormal = Innite
Not shown
FOR SERVICE TECHNICIAN’S USE ONLY
30
Component Serviceable
Side Procedure Results - Resistance Component
Location
Primary Interlock
Switch
Top Test 1:
1. Unplug microwave oven or disconnect power.
2. Disconnect the wires at the Primary Interlock Switch.
3. Check from the common terminal (brown wire) to the
normally open terminal (yellow wire).
4. Reconnect the wires at the Primary Interlock Switch.
5. Reassemble all parts and panels before operating.
6. Plug in microwave oven or reconnect power.
Test 1:
Door Open = Innite
Door Closed = Continuity
N
Test 2:
1. Unplug microwave oven or disconnect power.
2. Disconnect the wires at the Primary Interlock Switch.
3. Check from the common terminal (brown wire) to the
normally closed terminal (blue wire).
4. Reconnect the wires at the Primary Interlock Switch.
5. Reassemble all parts and panels before operating.
6. Plug in microwave oven or reconnect power.
Test 2:
Door Open = Continuity
Door Closed = Innite
Secondary Interlock
Switch
Top 1. Unplug microwave oven or disconnect power.
2. Disconnect the wires at the Secondary Interlock Switch.
3. Check from the common terminal (blue wire) to the
normally open terminal (white wire).
4. Reconnect the wires at the Secondary Interlock Switch.
5. Reassemble all parts and panels before operating.
6. Plug in microwave oven or reconnect power.
Door Open = Continuity
Door Closed = Innite
I
Monitor Interlock
Switch
Top 1. Unplug microwave oven or disconnect power.
2. Disconnect the wires at the Monitor Interlock Switch.
3. Check from the common terminal (yellow wire) to the
normally closed terminal (blue wire).
4. Reconnect the wires at the Monitor Interlock Switch.
5. Reassemble all parts and panels before operating.
6. Plug in microwave oven or reconnect power.
Door Open = Continuity
Door Closed = Innite
O
31
Component
Serviceable
Side Procedure Results - Resistance
Component
Location
Halogen Light Unplug microwave oven or disconnect power. Top 1.
2. Remove wire leads.
3. Measure resistance.
4. Replace wire leads.
5. Reassemble all parts and panels before operating.
6. Plug in microwave oven or reconnect power.
Normal = approximately 3 Ί
Abnormal = Innite
M
Inverter Check wiring to MW inverter:Top
1. Unplug microwave oven or disconnect power.
2. Visually inspect 4 connectors on the MW inverter
boards, CN701, CN702, CN703, and E701 to see
whether there are signs of overheating or any signs of
failure due to loose wires, bad crimping, etc.
3. Reassemble all parts and panels before operating.
4. Plug in microwave oven or reconnect power.
S
Magnetron Unplug microwave oven or disconnect power. Top 1.
2. Remove wire leads. Check that the seal is in good
condition.
3. Measure resistance.
4. Replace wire leads.
5. Reassemble all parts and panels before operating.
6. Plug in microwave oven or reconnect power.
Filament Terminals Normal =
<1W
Filament to Chassis Normal =
Innite
Q
Line Filter Unplug microwave oven or disconnect power. Top 1.
2. Remove wire leads.
3. Measure resistance.
4. Replace wire leads.
5. Reassemble all parts and panels before operating.
6. Plug in microwave oven or reconnect power.
P31 to P32, P33toP34 Normal
>/= 300 kΊ
Abnormal
</= 100 kΊ
P31 to P34, P32 to P33 Normal
= 0 Ί
Abnormal
>/= 100 kΊ
D
FOR SERVICE TECHNICIAN’S USE ONLY
32
Component Serviceable
Side Procedure Results - Resistance Component
Location
Humidity Sensor Unplug microwave oven or disconnect power. Top 1.
2. Remove the 3-pin connector from MW Appliance
Manager.
3. Measure resistance across pins 1 and 3 andacross pins
2 and 3.
4. Replace the 3-pin connector from MWAppliance
Manager.
5. Reassemble all parts and panels before operating.
6. Plug in microwave oven or reconnect power.
Normal = 2.8 kΊ (approximately)
at 77°F ± 10°F (25°C± 10°C)
Abnormal = Innite
E
Magnetron
Thermistor
1. Unplug microwave oven or disconnect power.
2. Remove wire leads.
3. Measure resistance.
4. Replace wire leads.
5. Reassemble all parts and panels before operating.
6. Plug in microwave oven or reconnect power.
Normal = 10 kΊ (approximately)
at 77°F ± 10°F (25°C± 10°C)
Abnormal = Innite
P
Grill Thermostat Unplug microwave oven or disconnect power. Top 1.
2. Remove wire leads.
3. Measure resistance.
4. Replace wire leads.
5. Reassemble all parts and panels before operating.
6. Plug in microwave oven or reconnect power.
Normal = Continuity
Abnormal = Innite
U
Convect Thermostat Rear Unplug microwave oven or disconnect power. 1.
2. Remove wire leads.
3. Measure resistance.
4. Replace wire leads.
5. Reassemble all parts and panels before operating.
6. Plug in microwave oven or reconnect power.
Normal = Continuity
Abnormal = Innite
B
33
Component
Serviceable
Side Procedure Results - Resistance
Component
Location
Broil Element Rear Unplug microwave oven or disconnect power. 1.
2. Remove wire leads.
3. Measure resistance.
4. Replace wire leads
5. Reassemble all parts and panels before operating.
6. Plug in microwave oven or reconnect power.
Normal = 9 Ί
Abnormal = Innite
K
Convect Element Rear Unplug microwave oven or disconnect power. 1.
2. Remove wire leads.
3. Measure resistance.
4. Replace wire leads.
5. Reassemble all parts and panels before operating.
6. Plug in microwave oven or reconnect power.
Normal = 12 Ί
Abnormal = Innite
C
Cavity Temperature
Sensor
Rear Unplug microwave oven or disconnect power.1.
2. Remove wire leads.
3. Measure resistance.
4. Replace wire leads.
5. Reassemble all parts and panels before operating.
6. Plug in microwave oven or reconnect power.
Normal = 230 KΊ
(approximately) at77°F ± 10°F
(25°C ¹ 10°C)
Abnormal = Innite
T
Convect Fan Motor Rear Unplug microwave oven or disconnect power.1.
2. Remove wire leads.
3. Measure resistance.
4. Replace wire leads.
5. Reassemble all parts and panels before operating.
6. Plug in microwave oven or reconnect power.
Normal = 48 Ί
Abnormal = Innite
A
À L’USAGE DU TECHNICIEN DE MAINTENANCE SEULEMENT
Manuel technique Ne pas enlever ou dĂŠtruire
W11405739A 08/20
AVERTISSEMENT
Risque de choc ĂŠlectrique
DĂŠconnecter la source de courant
ĂŠlectrique avant l'entretien.
Replacer pièces et panneaux avant de faire
la remise en marche.
Le non-respect de ces instructions peut
causer un dÊcès ou un choc Êlectrique.
DANGER
Risque de choc ĂŠlectrique
Seul un technicien autorisĂŠ est habilitĂŠ Ă 
effectuer des mesures de tension aux fins
de diagnostic.
Après avoir effectuÊ des mesures de
tension, dĂŠconnecter la source de courant
ĂŠlectrique avant toute intervention.
Le non-respect de ces instructions peut
causer un dÊcès ou un choc Êlectrique.
Mesures de tension — Information de sécurité
Lors des mesures de tension, observer les prĂŠcautions suivantes :
■ Vérifier que les commandes sont à la position d’interruption de l’alimentation, pour que l’appareil
ne puisse se mettre en marche dès le raccordement à une source d’énergie.
■ Ménager un espace adéquat pour l’exécution des mesures de tension.
■ Maintenir toute personne présente à distance de l’appareil, pour éviter tout risque de blessure.
■ Toujours utiliser les instruments et outils de test appropriés.
■ Après les mesures de tension, veiller toujours à interrompre l’alimentation électrique de l’appareil
avant toute intervention sur l’appareil.
À L’USAGE DU TECHNICIEN DE MAINTENANCE SEULEMENT
36
IMPORTANT:
Circuits ĂŠlectroniques sensibles aux dĂŠcharges ĂŠlectrostatiques
Le risque de dĂŠcharge ĂŠlectrostatique est per Une dĂŠcharge ĂŠlectrostatique peut dĂŠtmanent. ruire ou dĂŠtĂŠriorer les
circuits Êlectroniques de la machine. La nouvelle carte peut sembler fonctionner correctement après la rÊparation,
mais une dĂŠcharge ĂŠlectrostatique peut lui it subir des contraintes qui pr oqueront une dĂŠfavoir fa ov a .illance plus tard
■
Utiliser un bracelet de dĂŠcharge ĂŠlectrostatique. Connecter le bracelet de dĂŠcharge ĂŠlectrostatique au point vert
de raccordement Ă  la terre ou Ă  une surface mĂŠtallique non peinte Ă  l'intĂŠrieur de l'appareil.
-OU-
Toucher plusieurs fois de suite avec le doigt un point vert de raccordement Ă  la terre ou une surface mĂŠtallique
non peinte Ă  l'intĂŠrieur de l'appareil.
■
Avant de retirer la pièce de son emballage, placer le sachet antistatique en contact avec un point vert de
raccordement Ă  la terre ou une surface mĂŠtallique non peinte Ă  l'intĂŠrieur de l'appareil.
■
Éviter de toucher les composants électroniques ou les broches de contact; manipuler les circuits électroniques de
la machine uniquement par les bords
.
■
Lors du remballage de circuits ĂŠlectroniques dĂŠfectueux dans le sachet antistatique, observer les instructions ci-
dessus
.
37
PRÉCAUTIONS À OBSERVER ANT ET AV
DURANT LES RÉPARATIONS POUR ÉVITER
UNE EXPOSITION EXCESSIVE À L’ÉNERGIE
DES MICRO-ONDES
a. Ne pas laisser fonctionner le four lorsque la porte est ouverte.
b. Sur chaque four, ant d’alimenter le magnétron ou une autre source de micro-ondes, écuter les av ex
contrĂ´les de sĂŠcuritĂŠ suivants et effectuer les rĂŠparations nĂŠcessaires:
1. Système d’interverrouillage – fonctionnement correct
2. rte – rmeture correctePo fe
3. Joint et surfaces de scellement (formation d’arcs, usure et autres détériorations)
4. Charnières et loquets – détérioration ou ajustement déficient (desserrage)
5. Indices de dĂŠtĂŠrioration par chute ou emploi abusif
c. ant de dĂŠclencher la production de micro-ondes pour des opĂŠrations de test ou inspection dans les Av
compartiments de génération de micro-ondes, contrôler magnétron, guide d’ondes/canal de
transmission et cavité–contrôler/vérifier alignement correct, intégrité, connexions.
d. ant de remettre le four Ă  son propriĂŠtaire, toute dĂŠfectuositĂŠ ou dĂŠficience d'ajustement de Av
composant affectant interverrouillage, moniteur, joint de porte et gĂŠnĂŠration/transmission des micro-
ondes devra ĂŞtre ĂŠliminĂŠe par rĂŠparation/remplacement/rĂŠglage conformĂŠment aux procĂŠdures
dĂŠcrites dans ce manuel.
e. ant de remettre le four Ă  son propriĂŠtaire, effectuer un contrĂ´le des fuites du four Ă  micro-ondes pour Av
vĂŠrifier la conformitĂŠ aux prescriptions de la norme fĂŠdĂŠrale de performance.
Ne pas tenter de faire fonctionner le four si le hublot de la porte est brisĂŠ.f.
À L’USAGE DU TECHNICIEN DE MAINTENANCE SEULEMENT
38
Diagnostic
IMPORTANT: Avant de mettre sous tension le magnétron du four à micro-
ondes (MO), s’assurer qu’une charge, par exemple une tasse d’eau allant
auxmicro-ondes, est présente dans la cavité du four à micro-ondes.
DĂŠbrancher le four ou dĂŠconnecter la source de courant ĂŠlectrique avant
d’exécuter les contrôles suivants:
■La corrosion des pièces de connexion est une cause potentielle
de dĂŠfaillance du fonctionnement des commandes. Inspecter les
connexionset contrôler la continuité des circuits à l’aide d’un ohmmètre.
■Exécuter tous les tests ou contrôles à l’aide d’un voltmètre ou multimètre
à résistance interne de 20000Ω par VCC ou plus.
■Contrôler toutes les connexions avant de remplacer des composants;
rechercher les conducteurs brisĂŠs ou mal branchĂŠs, les connexions
mal réalisées ou les ls insufsamment engagés dans les connecteurs.
Unfaisceau de câblage endommagé doit être remplacé dans son
intÊgralitÊ. Ne pas rÊparer un faisceau de câblage.
■Exécuter les mesures de résistance après avoir débranché le cordon
d’alimentation de la prise de courant et déconnecté les connecteurs
oulefaisceau de câblage.
IMPORTANT: Ne pas remplacer le module de commande en l’absence de
preuve d’une défaillance.
Pour accéder au mode de diagnostic:
Avant d’entreprendre toute action corrective, exécuter le processus décrit
ci-dessous pour accéder au mode de diagnostic:
1. AccĂŠder au mode de diagnostic en appuyant sur LOWER OVEN>LOWER
LIGHT>OVEN CANCEL (four infĂŠrieur>lampe infĂŠrieure>annulation du
four) – répéter 2 autres fois.
CONSEIL: Il est aussi possible de glisser le doigt 3 fois de la gauche
vers la droite sur les touches.
REMARQUE: Il n’est pas nécessaire d’attendre pour une rétroaction
audible ou visuelle de la commande après chaque appui sur les touches.
2. Si la commande ne passe pas en mode de diagnostic, continuer
à répéter la séquence des touches à partir de l’étape1. Toutes les
touchess’allumeront lorsque la commande passe en mode de diagnostic.
3. À partir du menu de diagnostic, faire déler la liste jusqu’à la sélection
souhaitée en utilisant l’écran tactile.
Error Diagnostics (diagnostic d’erreur): Afcher et effacer l’historique
des dĂŠfaillances.
Component Activation (activation composant) : Activer manuellement
chaque relais.
Sensors & Switches (capteurs et contacteurs) : Afcher les températures
de la cavitĂŠ du four traditionnel et le statut du contacteur de porte/loquet.
System Information (informations système): Afcher le numéro de
modèle, le numÊro de sÊrie et les versions de logiciel.
Sortir Diagnostics
Procédure générale: Codes d’erreur
REMARQUE: Toutes les défaillances sont mémorisées dans l’historique des
défaillances. Pour vérier si le code d’erreur est toujours présent, lancer une
fonction de cuisson et patienter 1 minute.
1. Brancher le four ou reconnecter la source de courant ĂŠlectrique.
2. AccĂŠder au mode de diagnostic.
3. Appuyer sur ou faire déler la liste jusqu’à l’élément “Error Diagnostics”
dans le menu de diagnostic, puis appuyer sur “OK”.
4. Pour effacer les codes d’erreur, appuyer sur “Clear History” (effacer
l’historique).
5. Si aucune défaillance n’est répertoriée, le message “No Error” (aucune
erreur) s’afche à l’écran.
39
Procédure générale: Activation composant
1. Brancher le four ou reconnecter la source de courant ĂŠlectrique.
2. AccĂŠder au mode de diagnostic.
3. Appuyer sur ou faire déler la liste jusqu’à l’élément “Component
Activation” (activation composant) dans le menu de diagnostic, puis
appuyer sur “OK”.
4. Appuyer sur les sĂŠlections suivantes activer/dĂŠsactiver les relais
correspondants.
SĂŠlection Relais
MW Light (lampe du MO) Relais de la lampe MO
MW Turntable (plateau rotatif du MO) Relais du plateau rotatif MO
MW Cooling Fan (ventilateur de
refroidissement du MO)
Relais du ventilateur de
refroidissement MO
MW Grill (gril du MO) Relais de l’élément du gril MO
MW Convection Element (ĂŠlĂŠment de
convection du four Ă  micro-ondes)
Relais de l’élément de convection
MO
MW Convection Fan (ventilateur de
convection du MO)
Relais du ventilateur de convection
MO
MW Magnetron/Cooling Fan (ma-
gnĂŠtron/ventilateur de refroidisse-
ment du four Ă  micro-ondes)
Relais du magnĂŠtron et du
ventilateur de refroidissement MO
Oven Bake Element (ĂŠlĂŠment de
cuisson du four)
Relais de l’élément de cuisson du
four
Oven Broil Element (ĂŠlĂŠment de
grillage du four)
Relais de l’élément de grillage du
four
Oven Convection Element (ĂŠlĂŠment
de convection du four)
Relais de l’élément de convection
du four
Oven Convection Fan (ventilateur de
convection du four)
Relais du ventilateur de convection
du four
Oven Cooling Fan High Speed
(ventilateur de refroidissement du
four – vitesse élevée)
Relais de vitesse ĂŠlevĂŠe du
ventilateur de refroidissement du four
SĂŠlection Relais
Oven Cooling Fan Low Speed
(ventilateur de refroidissement
dufour – vitesse basse)
Relais de vitesse basse du
ventilateur de refroidissement
dufour
Lampe du four Relais de la lampe du four
Oven Door Latch Motor (moteur du
loquet de porte du four)
Relais du moteur du loquet de porte
du four
Procédure générale: Capteurs et contacteurs
REMARQUE: Cette procédure est utile pour afcher le statut actuel des
contacteurs du four et des lectures du capteur.
Afchage État
MW Door Switch (contacteur porte MO) Ouvert ou FermĂŠ
MW Cavity TempĂŠrature (tempĂŠrature cavitĂŠ MO) DegrĂŠs en Celsius
Oven Door Switch (contacteur porte four) Ouvert ou FermĂŠ
Oven Latch Switch (contacteur loquet four) Ouvert ou FermĂŠ
Oven Cavity TempĂŠrature (tempĂŠrature cavitĂŠ
four) DegrĂŠs en Celsius
Oven Meat Probe TempĂŠrature (tempĂŠrature de la
sonde de cuisson du four) DegrĂŠs en Celsius
1. Brancher le four ou reconnecter la source de courant ĂŠlectrique.
2. AccĂŠder au mode de diagnostic.
3. Appuyer sur ou faire déler la liste jusqu’à l’élément “Sensors &
Switches” (capteurs et contacteurs) dans le menu de diagnostic, puis
appuyer sur “OK”.
4. Appuyer sur ou faire déler le menu Sensors & Switches (capteurs et
contacteurs) pour afcher l’état désiré.
REMARQUE: Appuyer sur “Back” pour revenir au menu de diagnostic
principal.
À L’USAGE DU TECHNICIEN DE MAINTENANCE SEULEMENT
40
Procédure générale: Informations système
REMARQUE: Cette procédure est utile pour afcher les informations
système suivantes:
Informations système Afchage
No de modèle Information sur le modèle
NumĂŠro de sĂŠrie NumĂŠro de sĂŠrie du produit
Numéro de série IU Numéro de série de l’interface utilisateur
numĂŠro de sĂŠrie du MCA du four NumĂŠro de sĂŠrie du module de
commande de l’appareil
Version IU Version logiciel d’interface utilisateur
HMI Central SW (VL HMI centrale) Version de logiciel de carte HMI centrale
HMI Left SW (VL HMI gauche) Version logiciel de clavier HMI gauche
HMI Left EE (EE HMI gauche) Version EEPROM de clavier HMI gauche
HMI Right SW (VL HMI droit) Version logiciel de clavier HMI droit
HMI Right EE (EE HMI droit) Version EEPROM de clavier HMI droit
Version noyau Version de logiciel de carte HMI centrale
Appuyer sur la version de calibrage Version logiciel ACL/ĂŠcran tactile FPC
rĂŠcursion terminale
Database Version (version de la
base de donnĂŠes)
Structure de la base de donnĂŠes de
carte HMI centrale
Audio Version (version audio) Version de logiciel de carte HMI centrale
Oven ACU SW (version de logiciel
MCA du four)
Version logiciel du module de
commande du four
MWO ACU SW (version de
logiciel du module de commande
du four Ă  micro-ondes)
Version de logiciel du module de
commande du four Ă  micro-ondes
EntrĂŠes de diagnostic Nombre de fois oĂš le menu de
diagnostic a ĂŠtĂŠ ouvert.
1. Brancher le four ou reconnecter la source de courant ĂŠlectrique.
2. AccĂŠder au mode de diagnostic.
3. Appuyer sur ou faire déler la liste jusqu’à l’élément “System Information”
(informations du système) dans le menu de diagnostic, puis appuyer sur
“OK”.
4. Appuyer sur ou faire déler le menu System Information (information
système) pour afcher l’état désiré.
REMARQUE: Appuyer sur “Back” pour revenir au menu de diagnostic
principal.
Procédure générale: sélection du modèle
REMARQUE: Lorsqu’une nouvelle interface utilisateur (IU) est installée, une
demande de sélection du numéro de modèle s’afche à l’écran dès la mise
sous tension. Pour changer le numéro de modèle sur l’interface utilisateur
existante, suivre les ĂŠtapes ci-dessous.
1. Brancher le four ou reconnecter la source de courant ĂŠlectrique.
2. AccĂŠder au mode de diagnostic.
3. Appuyer sur ou faire déler la liste jusqu’à l’élément System Information
(informations du système) dans le menu de diagnostic, puis appuyer sur
“OK”.
4. Appuyer sur ou faire déler la liste jusqu’à l’élément “Model Number”
(numéro de modèle), puis appuyer sur “OK”.
5. Appuyer sur ou faire déler la liste jusqu’au numéro de modèle correct
dans la liste, puis appuyer sur “Select” (sélectionner).
41
Codes de défaillance/d’erreur présentés sur l’afcheur
Pas d’afchage – panneau de
commande vide Alimentation Ă  dĂŠcoupage (SMPS),
interface utilisateur (UI)
ACTION CORRECTIVE SUGGÉRÉE
REMARQUE: Avant de commencer un test, couper l’alimentation du four et
la rétablir (éteindre, patienter 10secondes et rallumer).
1. Débrancher le four ou couper l’alimentation électrique.
2. Retirer le couvercle en plastique de l’interface utilisateur UI. Vérier la
connexion de l’afcheur à l’interface utilisateur.
3. Vérier le câblage entre la ligne principale et l’alimentation à découpage
SMPS (CONN7).
4. Vérier la connexion entre le faisceau de câblage et l’interface utilisateur
UI (J15).
5. Vérier que la tension d’entrée entre J15-2 (TERRE) et J15-4 (14V CC)
sur l’IU est correcte en procédant aux étapes suivantes.
6. Connecter l’appareil de mesure de tension entre J15-2 et J15-4 sur l’UI.
7. Brancher le four ou reconnecter la source de courant ĂŠlectrique.
8. Mesurer la tension et conrmer que la tension afchée est bien de
14VCC. Si la tension est correcte, débrancher le four ou déconnecter
la source de courant électrique et passer à l’étape13. Si la tension n’est
pas correcte, passer à l’étape9.
9. Débrancher le four ou couper l’alimentation électrique.
Remplacerl’alimentation SMPS.
10. RÊinstaller les pièces et panneaux avant de faire la mise en marche.
11. Brancher le four ou reconnecter la source de courant ĂŠlectrique.
12. Contrôler l’afchage de la carte de commande. Si l’afchage reste vierge,
dĂŠbrancher le four ou dĂŠconnecter la source de courant ĂŠlectrique.
13. HMI-central/carte IU.
14. RÊinstaller les pièces et panneaux avant de faire la mise en marche.
15. Brancher le four ou reconnecter la source de courant ĂŠlectrique.
Sil’interface utilisateur a été remplacée, suivre les instructions à l’écran
pour sÊlectionner le numÊro de modèle.
16. Vérier que le fonctionnement est normal. Si le problème persiste,
remplacer le tableau de commande et répéter les étapes14 à 16.
N L2 L1
P1
1 2 3 4 5
BL
N
BL
MAR
J
Gestionnaire
du four
Interface
utilisateur
Gestionnaire
d’appareil du four
Ă  micro-ondes
P26
O
1 2 3 4 5
1 2 3 4
1
2
1
1
3
2
24
5
6
1
3
2
4
BL
P1
J8
N
J
MAR O
J5
J15
J7 HMI Right
(HMI droit)
HMI Left
(HMI gauche)
J4J6
SMPS
14 V DC
15W
CONN2
CONN7
N
BL O
J
O
52 BL
Thermostat
de la cavitĂŠ
42 BL
Fusible en sĂŠrie
(20A)
P34 41 BL
Filtre
de ligne
P33
L1
P31
P32
Tableau de commande
À L’USAGE DU TECHNICIEN DE MAINTENANCE SEULEMENT
44
DÉFAILLANCE ERREUR DÉFAILLANCE PROBABLE
F1 E4 Erreur du relais4903 du four à micro-ondes
ACTION CORRECTIVE SUGGÉRÉE
REMARQUE: Avant de commencer un test, couper l’alimentation du four et
la rétablir (éteindre, patienter 10secondes et rallumer). Après la mise sous
tension, s’assurer qu’une charge, par exemple une tasse d’eau allant aux
micro-ondes, est prĂŠsente dans la cavitĂŠ du four Ă  micro-ondes et dĂŠmarrer
une fonction de cuisson. Attendre 1 minute avant de vérier que la défaillance
se reproduit.
1. Vérier que le contacteur de porte fonctionne correctement: lorsquela
porte est ouverte, la lampe du four Ă  micro-ondes est allumĂŠe, et
lorsqu’elle est fermée, la lampe est éteinte.
2. Débrancher le four ou couper l’alimentation électrique.
3. Vérier les éléments suivants sur le gestionnaire du four à micro-ondes:
a. Connexions vers le relais4903
b. Vérier si le relais4903 est court-circuité. Si tel est le cas, passer à
l’étape7.
4. RÊinstaller les pièces et panneaux avant de faire la mise en marche.
5. Brancher le four ou reconnecter la source de courant ĂŠlectrique.
6. Pour vérier si le code d’erreur est toujours présent, s’assurer qu’une
charge, par exemple une tasse d’eau allant aux micro-ondes, est
prĂŠsente dans la cavitĂŠ du four Ă  micro-ondes et dĂŠmarrer une fonction
de cuisson dans le four à micro-ondes. Patienter 1 minute pour vérier si
la défaillance se produit. Si l’erreur persiste, passer à l’étape7. Si tel n’est
pas le cas, passer à l’étape10.
7. DĂŠbrancher le four ou dĂŠconnecter la source de courant ĂŠlectrique et
remplacer le gestionnaire du four Ă  micro-ondes.
8. RÊinstaller les pièces et panneaux avant de faire la mise en marche.
9. Brancher le four ou reconnecter la source de courant ĂŠlectrique.
10. Vérier que le fonctionnement est normal. Accéder au menu de diagnostic
sélectionnerError Diagnostics(diagnostic d’erreur) et effacer l’historique.
DÉFAILLANCE ERREUR DÉFAILLANCE PROBABLE
F1 E5 Erreur de l’onduleur du four à micro-ondes
ACTION CORRECTIVE SUGGÉRÉE
REMARQUE: Avant de commencer un test, couper l’alimentation du four et
la rétablir (éteindre, patienter 10secondes et rallumer). Après la mise sous
tension, s’assurer qu’une charge, par exemple une tasse d’eau allant aux
micro-ondes, est prĂŠsente dans la cavitĂŠ du four Ă  micro-ondes et dĂŠmarrer
une fonction de cuisson. Attendre 1 minute avant de vérier que la défaillance
se reproduit.
1. Vérier que le contacteur de porte fonctionne correctement: lorsque
la porte est ouverte, la lampe du four Ă  micro-ondes est allumĂŠe, et
lorsqu’elle est fermée, la lampe est éteinte.
2. Débrancher le four ou couper l’alimentation électrique.
3. Vérier les éléments suivants sur le gestionnaire du four à micro-ondes:
a. Relais4903
b. ConnecteurP8
4. Vérier les connexions suivantes sur le circuit onduleur:
a. CN701
b. CN702
c. CN703
5. Si la porte fonctionne correctement et toutes les connexions sont
correctes, remplacer le circuit onduleur du four Ă  micro-ondes.
6. RÊinstaller les pièces et panneaux avant de faire la mise en marche.
7. Brancher le four ou reconnecter la source de courant ĂŠlectrique.
Fusible en sĂŠrie
(20A)
Contacteur
d’interverrouillage
primaire
Onduleur
Relais du micro-ondes
4903
1
4
MAR BL
CN702
L1
MagnĂŠtron
Onduleur du four
Ă  micro-ondes
INTERFACE MLI
Vers relais
MO 4903
P8
P354
BL
BL
123
CN701
E701
CN703
CN702
R R
J/TERRE
32 1
P355
45
8. Pour vérier si le code d’erreur est toujours présent, s’assurer qu’une
charge, par exemple une tasse d’eau allant aux micro-ondes, est
prĂŠsente dans la cavitĂŠ du four Ă  micro-ondes et dĂŠmarrer une fonction
de cuisson dans le four à micro-ondes. Patienter 1 minute pour vérier si
la défaillance se produit. Si l’erreur persiste, passer à l’étape9. Si tel n’est
pas le cas, passer à l’étape17.
9. Débrancher le four ou couper l’alimentation électrique.
10. Remplacer le magnĂŠtron.
11. RÊinstaller les pièces et panneaux avant de faire la mise en marche.
12. Brancher le four ou reconnecter la source de courant ĂŠlectrique.
13. Pour vérier si le code d’erreur est toujours présent, s’assurer qu’une
charge, par exemple une tasse d’eau allant aux micro-ondes, est
prĂŠsente dans la cavitĂŠ du four Ă  micro-ondes et dĂŠmarrer une fonction
de cuisson dans le four à micro-ondes. Patienter 1 minute pour vérier si
la défaillance se produit. Si l’erreur persiste, passer à l’étape14.
Si tel n’est pas le cas, passer à l’étape17.
14. DĂŠbrancher le four ou dĂŠconnecter la source de courant ĂŠlectrique et
remplacer le module de commande du four Ă  micro-ondes.
15. RÊinstaller les pièces et panneaux avant de faire la mise en marche.
16. Brancher le four ou reconnecter la source de courant ĂŠlectrique.
17. Vérier que le fonctionnement est normal. Accéder au menu de diagnostic
sélectionnerError Diagnostics(diagnostic d’erreur) et effacer l’historique.
DÉFAILLANCE ERREUR DÉFAILLANCE PROBABLE
F1 E6 Erreur de gĂŠnĂŠration des micro-ondes
ACTION CORRECTIVE SUGGÉRÉE
REMARQUE: Avant de commencer un test, couper l’alimentation du four et
la rétablir (éteindre, patienter 10secondes et rallumer). Après la mise sous
tension, s’assurer qu’une charge, par exemple une tasse d’eau allant aux
micro-ondes, est prĂŠsente dans la cavitĂŠ du four Ă  micro-ondes et dĂŠmarrer
une fonction de cuisson. Attendre 1 minute avant de vérier que la défaillance
se reproduit.
1. Vérier que le contacteur de porte fonctionne correctement: lorsque
la porte est ouverte, la lampe du four Ă  micro-ondes est allumĂŠe, et
lorsqu’elle est fermée, la lampe est éteinte.
2. Débrancher le four ou couper l’alimentation électrique.
3. Vérier les éléments suivants sur le gestionnaire du four à micro-ondes:
a. Relais4903
4. Si la porte fonctionne correctement et toutes les connexions sont
correctes, remplacer le magnĂŠtron.
5. RÊinstaller les pièces et panneaux avant de faire la mise en marche.
6. Brancher le four ou reconnecter la source de courant ĂŠlectrique.
7. Pour vérier si le code d’erreur est toujours présent, s’assurer qu’une
charge, par exemple une tasse d’eau allant aux micro-ondes, est
prĂŠsente dans la cavitĂŠ du four Ă  micro-ondes et dĂŠmarrer une fonction
de cuisson dans le four à micro-ondes. Patienter 1 minute pour vérier si
la défaillance se produit. Si l’erreur persiste, passer à l’étape8. Si tel n’est
pas le cas, passer à l’étape16.
8. DĂŠbrancher le four ou dĂŠconnecter la source de courant ĂŠlectrique et
remplacer le circuit onduleur.
9. RÊinstaller les pièces et panneaux avant de faire la mise en marche.
10. Brancher le four ou reconnecter la source de courant ĂŠlectrique.
Fusible en sĂŠrie
(20A)
Contacteur
d’interverrouillage
primaire
Onduleur
Relais du micro-ondes
4903
1
4
MAR BL
CN702
L1
47
DÉFAILLANCE ERREUR DÉFAILLANCE PROBABLE
CapteurF3 E0 Capteur du four principal ouvert ou court-
circuitĂŠ
ACTION CORRECTIVE SUGGÉRÉE
REMARQUE: Avant de commencer un test, couper l’alimentation du four et
la rétablir (éteindre, patienter 10secondes et rallumer).
MÉTHODE: Avant de poursuivre, vérier le code d’erreur en entrant le mode
de diagnostic et sélectionnant “Error Diagnostics” (diagnostic d’erreur).
1. Débrancher le four ou couper l’alimentation électrique.
2. Débrancher le connecteurP3 du gestionnaire du four et mesurer la
rĂŠsistance du capteur entre P3-1 et P3-2. La mesure doit ĂŞtre entre
1000Ω et 1200Ω à 77°F (25°C). Vérier que le capteur n’est pas
court-circuitĂŠ Ă  la masse. Si les contrĂ´les sur le capteur ne sont pas
corrects, le remplacer et effectuer de nouveau les contrĂ´les.
3. RÊassembler les pièces et panneaux et brancher le four ou reconnecter
lasource de courant électrique.
4. Entrer le mode de diagnostic et sélectionner “Sensors & Switches”
(capteurs et contacteurs) pour vérier si la température indiquée sur
l’afcheur de température de la cavité du four est correcte (température
ambiante). Si tel est le cas, passer à l’étape8. Sinon, débrancher le four
ou dĂŠconnecter la source de courant ĂŠlectrique.
REMARQUE: Sur l’écran de l’état, l’unité de mesure est en Celsius.
5. Remplacer le gestionnaire de l’appareil Copernicus.
6. RÊinstaller les pièces et panneaux avant de faire la mise en marche.
7. Brancher le four ou reconnecter la source de courant ĂŠlectrique.
8. Vérier que le fonctionnement est normal. Accéder au mode de
diagnostic, sélectionner “Error Diagnostics” (diagnostic d’erreur)
eteffacer l’historique.
DÉFAILLANCE ERREUR DÉFAILLANCE PROBABLE
CapteurF3 E3 Sonde de cuisson ou prise de connecteur de
sonde de cuisson court-circuitĂŠe
ACTION CORRECTIVE SUGGÉRÉE
REMARQUE: Avant de commencer un test, couper l’alimentation du four et
la rétablir (éteindre, patienter 10secondes et rallumer).
MÉTHODE: Avant de poursuivre, vérier le code d’erreur en entrant le mode
de diagnostic et sélectionnant “Error Diagnostics” (diagnostic d’erreur).
1. Débrancher le four ou couper l’alimentation électrique.
2. Retirer la sonde de cuisson Ă  viande si celle-ci est connectĂŠe.
3. Débrancher le connecteurP3 du gestionnaire de l’appareil Copernicus.
4. Vérier la continuité de la prise des câblages entre P3-3 et P3-4.
Si elle indique 0Ω, remplacer la prise et passer à l’étape5.
Si elle n’indique pas 0Ω, la prise fonctionne correctement.
Passer à l’étape5.
5. Brancher la sonde de cuisson et vérier si elle est ouverte ou court-
circuitĂŠe vers la terre. Si les contrĂ´les sur la sonde de cuisson ne sont
pas corrects, remplacer la sonde de cuisson. À 77°F (25°C), la valeur
attendue doit être d’environ 50kΩ. Si les contrôles sont corrects,
remplacer le gestionnaire de l’appareil Copernicus.
6. RÊinstaller les pièces et panneaux avant de faire la mise en marche.
7. Brancher le four ou reconnecter la source de courant ĂŠlectrique.
8. Vérier que le fonctionnement est normal. Accéder au mode de
diagnostic, sélectionner “Error Diagnostics” (diagnostic d’erreur) et
effacer l’historique. Vérier la lecture de la sonde à viande en entrant le
mode de diagnostic et sélectionnantSensors & Switches (capteurs et
contacteurs). La sonde Ă  viande devrait dĂŠtecter la tempĂŠrature ambiante.
Gestionnaire de
l’appareil Copernicus
Capteur
tempĂŠrature
du four
V
V1
2
3
4
5
6
7
8
9
10
P3
Gestionnaire de
l’appareil Copernicus
Capteur
de la sonde
de cuisson
O
TERRE
1
2
3
4
5
6
7
8
9
10
P3
À L’USAGE DU TECHNICIEN DE MAINTENANCE SEULEMENT
48
DÉFAILLANCE ERREUR DÉFAILLANCE PROBABLE
F4 E1 Erreur du capteur de tempĂŠrature de la cavitĂŠ
du four Ă  micro-ondes
ACTION CORRECTIVE SUGGÉRÉE
REMARQUE: Avant de commencer un test, couper l’alimentation du four et
la rétablir (éteindre, patienter 10secondes et rallumer). Après la mise sous
tension, s’assurer qu’une charge, par exemple une tasse d’eau allant aux
micro-ondes, est prĂŠsente dans la cavitĂŠ du four Ă  micro-ondes et dĂŠmarrer
une fonction de cuisson qui utilise un capteur de température, telle qu’un
programme Convect (convection). Attendre 1 minute avant de vérier que
ladéfaillance se reproduit.
1. Débrancher le four ou couper l’alimentation électrique.
2. Vérier que le connecteurP22 du gestionnaire du four à micro-ondes est
fermement connecté. Si tel est le cas, passer à l’étape3. Dans le cas
contraire, l’engager fermement et passer à l’étape5.
3. Débrancher le connecteurP22 du gestionnaire du four à micro-ondes et
mesurer la résistance de la thermistance. Elle doit valoir environ 230kΩ
à77°F ± 10°F (25°C ± 10°C).
4. Vérier que la thermistance n’est pas court-circuitée à la masse.
Si les contrĂ´les de la thermistance ne sont pas corrects, la remplacer.
Si le contrĂ´le de la thermistance est correct, remplacer le gestionnaire du
four Ă  micro-ondes.
5. RÊinstaller les pièces et panneaux avant de faire la mise en marche.
6. Brancher le four ou reconnecter la source de courant ĂŠlectrique.
7. Vérier que le fonctionnement est normal. Accéder au menu de
diagnostic sélectionner “Error Diagnostics” (diagnostic d’erreur) et
effacerl’historique.
DÉFAILLANCE ERREUR DÉFAILLANCE PROBABLE
F4 E2 Erreur du capteurde température du
magnĂŠtron
ACTION CORRECTIVE SUGGÉRÉE
REMARQUE: Avant de commencer un test, couper l’alimentation du four et
la rétablir (éteindre, patienter 10secondes et rallumer). Après la mise sous
tension, s’assurer qu’une charge, par exemple une tasse d’eau allant aux
micro-ondes, est prĂŠsente dans la cavitĂŠ du four Ă  micro-ondes et dĂŠmarrer
une fonction de cuisson. Attendre 1 minute avant de vérier que la défaillance
se reproduit.
1. Débrancher le four ou couper l’alimentation électrique.
2. Vérier que le connecteurP21 du gestionnaire du four à micro-ondes est
fermement connecté. Si tel est le cas, passer à l’étape3. Dans le cas
contraire, l’engager fermement et passer à l’étape5.
3. Débrancher le connecteurP21 du gestionnaire du four à micro-ondes et
mesurer la résistance de la thermistance. Elle doit valoir environ 10kΩ à
77°F ± 10°F (25°C ± 10°C).
4. Vérier que la thermistance n’est pas court-circuitée à la masse.
Si les contrĂ´les de la thermistance ne sont pas corrects, la remplacer.
Si le contrĂ´le de la thermistance est correct, remplacer le gestionnaire du
four Ă  micro-ondes.
5. RÊinstaller les pièces et panneaux avant de faire la mise en marche.
6. Brancher le four ou reconnecter la source de courant ĂŠlectrique.
7. Vérier que le fonctionnement est normal. Accéder au menu de
diagnostic sélectionner “Error Diagnostics” (diagnostic d’erreur) et
effacerl’historique.
P22
Ther
mistance
de la ca
vitĂŠ
Gestionnaire
dÊappareil
du four Ă 
micro-ondes P21
Ther
mistance
du magnĂŠtron
Gestionnaire
d’appareil du
four Ă 
micro-ondes
49
DÉFAILLANCE ERREUR DÉFAILLANCE PROBABLE
EntréesF4 E4 Erreur du capteur d’humidité du four à micro-
ondes
ACTION CORRECTIVE SUGGÉRÉE
REMARQUE: Avant de commencer un test, couper l’alimentation du four
et la rétablir (éteindre, patienter 10secondes et rallumer). Après la mise
sous tension, s’assurer qu’une charge, par exemple une tasse d’eau allant
aux micro-ondes, est prĂŠsente dans la cavitĂŠ du four Ă  micro-ondes et
démarrer une fonction de cuisson qui utilise un capteur d’humidité, telle
qu’un programme Steam (vapeur). Attendre 1 minute avant de vérier que
ladéfaillance se reproduit.
1. Débrancher le four ou couper l’alimentation électrique.
2. Vérier que le connecteurP23 du gestionnaire du four à micro-ondes est
fermement connecté. Si tel est le cas, passer à l’étape3. Dans le cas
contraire, l’engager fermement et passer à l’étape5.
3. Débrancher le connecteurP23 du gestionnaire du four à micro-ondes et
mesurer la résistance du capteur:
Entre les broches3 et 1. Elle doit valoir environ 2800Ω à 77°F ± 10°F
(25°C ± 10°C).
Entre les broches3 et 2. Elle doit valoir environ 2800Ω à 77°F ± 10°F
(25°C ± 10°C).
4. Vérier que le capteur n’est pas court-circuité à la masse. Si les contrôles
du capteur ne sont pas corrects, le remplacer. Si les contrĂ´les du capteur
sont corrects, remplacer le gestionnaire du four Ă  micro-ondes.
5. RÊinstaller les pièces et panneaux avant de faire la mise en marche.
6. Brancher le four ou reconnecter la source de courant ĂŠlectrique.
7. Vérier que le fonctionnement est normal. Accéder au menu de
diagnostic sélectionner “Error Diagnostics” (diagnostic d’erreur) et
effacerl’historique.
DÉFAILLANCE ERREUR DÉFAILLANCE PROBABLE
F4 E8 Surchauffe de l’onduleur
ACTION CORRECTIVE SUGGÉRÉE
REMARQUE: Avant de commencer un test, couper l’alimentation du four et
la rétablir (éteindre, patienter 10secondes et rallumer). Après la mise sous
tension, s’assurer qu’une charge, par exemple une tasse d’eau allant aux
micro-ondes, est prĂŠsente dans la cavitĂŠ du four Ă  micro-ondes et dĂŠmarrer
une fonction de cuisson. Attendre 1 minute avant de vérier que la défaillance
se reproduit.
1. Débrancher le four ou couper l’alimentation électrique.
2. Vérier ce qui suit:
a. Connexion du ventilateur de refroidissement pour tout connecteur
mal branchĂŠ
b. Installation du four; assurez-vous également qu’il n’y ait aucune
obstruction d’air
3. RÊinstaller les pièces et panneaux avant de faire la mise en marche.
4. Brancher le four ou reconnecter la source de courant ĂŠlectrique.
5. Pour vérier si le ventilateur de refroidissement est installé, s’assurer
qu’une charge, par exemple une tasse d’eau allant aux micro-ondes, est
prĂŠsente dans la cavitĂŠ du four Ă  micro-ondes et dĂŠmarrer une fonction
de cuisson dans le four à micro-ondes. S’assurer que le ventilateur
fonctionne. Si ce n’est pas le cas, débrancher le four ou déconnecter
la source de courant ĂŠlectrique, remplacer le ventilateur et passer Ă 
l’étape8. Sinon, passer à l’étape6.
6. Débrancher le four ou couper l’alimentation électrique.
7. Remplacer le circuit de l’onduleur.
8. RÊinstaller les pièces et panneaux avant de faire la mise en marche.
9. Brancher le four ou reconnecter la source de courant ĂŠlectrique.
10. Vérier que le fonctionnement est normal. Accéder au menu de
diagnostic sélectionner “Error Diagnostics” (diagnostic d’erreur) et
effacerl’historique.
Gestionnaire
dÊappareil d
u
four Ă 
micro-ondes
Capteur
dÊhumidité
1600
P23
À L’USAGE DU TECHNICIEN DE MAINTENANCE SEULEMENT
52
4. Mesurer la résistance entre les connecteursJ8-2 et P5-1. Elle doit être
comprise entre 500Ω et 3000Ω à 77°F (25°C).
5. Si la mesure de résistance est en dehors de l’intervalle, remplacer le
loquet de porte. Vérier que l’erreur a disparu. Si tous les contrôles
étaientcorrects, remplacer le gestionnaire de l’appareil Copernicus.
6. RÊinstaller les pièces et panneaux avant de faire la mise en marche.
7. Brancher le four ou reconnecter la source de courant ĂŠlectrique.
8. Vérier que le fonctionnement est normal. Accéder au menu de
diagnostic sélectionner “Error Diagnostics” (diagnostic d’erreur) et effacer
l’historique.
DÉFAILLANCE ERREUR DÉFAILLANCE PROBABLE
F6 E0 Interface utilisateur du four – perte de
communication
E6 Gestionnaire du four – perte de communication
ACTION CORRECTIVE SUGGÉRÉE
REMARQUE: Avant de commencer un test, couper l’alimentation du four et
la rétablir (éteindre, patienter 10secondes et rallumer).
MÉTHODE: Avant de poursuivre, vérier le code d’erreur en entrant le mode
de diagnostic et sélectionnant “Error Diagnostics” (diagnostic d’erreur).
1. Débrancher le four ou couper l’alimentation électrique.
2. Vérier la continuité des câblages entre P1-4 et J15-3, puis P1-5 et J15-2.
3. Vérier la continuité entre les brochesP1-1 et P1-2.
4. Si tous les contrôles sont corrects, remplacer le gestionnaire de l’appareil
Copernicus.
5. RÊinstaller les pièces et panneaux avant de faire la mise en marche.
6. Brancher le four ou reconnecter la source de courant ĂŠlectrique.
7. Si l’erreur se reproduit, débrancher le four ou déconnecter la source de
courant ĂŠlectrique.
8. Remplacer la carte HMI-central/IU.
9. RÊinstaller les pièces et panneaux avant de faire la mise en marche.
10. Brancher le four ou reconnecter la source de courant ĂŠlectrique.
11. Suivre les instructions à l’écran pour sélectionner le numéro de modèle si
l’interface utilisateur a été remplacée.
12. Vérier que le fonctionnement est normal. Accéder au mode de diagnostic,
sélectionner “Error Diagnostics” (diagnostic d’erreur) et effacer l’historique.
Gestionnaire de
l’appareil Copernicus
P5
J8
J
BL
BL
N
Moteur du loquet de porte
1
2
3
4
5
6
7
1
2
J
J
BL
N L
2 L1
1
2
3
4
BL
N
O
O
MAR P1
Gestionnaire
du four
SMPS
14V DC
15 W
CONN2
CONN7
HMI Right
(HMI droit)
J7J5
J15
Interface utilisateur
J4J6
HMI Left
(HMI gauche)
6
5
1
2
1 2 3 4 5
1 2 3 4 Tableau de commande
53
DÉFAILLANCE ERREUR DÉFAILLANCE PROBABLE
F6 E1 Surchauffe
ACTION CORRECTIVE SUGGÉRÉE
REMARQUE: Avant de commencer un test, couper l’alimentation du four et
la rétablir (éteindre, patienter 10secondes et rallumer).
MÉTHODE: Avant de poursuivre, vérier le code d’erreur en entrant le mode
de diagnostic et sélectionnant “Error Diagnostics” (diagnostic d’erreur).
1. Débrancher le four ou couper l’alimentation électrique.
2. Vérier si des éléments sont court-circuités. Vérier la résistance des éléments:
a. PX4-2 et PX3-2 – vérier l’élément de cuisson au gril (13,2Ωà 14,6Ω)
b. PX1-1 et PX3-2 – vérier l’élément de cuisson au four (19Ωà 21Ω)
c. PX1-3 et PX3-2 – vérier l’élément de convection supérieur (15,2Ω à
17,3Ω)
3. S’il existe un élément court-circuité à la terre, remplacer l’élément.
4. Vérier les éventuels courts-circuits dans les relais.
Pour les modèles principaux: Débrancher les connecteursPX1 et PX4
et vérier les éventuels courts-circuits entre:
a. PX1-1 et PX1-2 (relais de cuisson au four)
b. PX1-3 et PX1-4 (relais de convection)
c. PX4-1 et PX4-2 (relais de cuisson au gril)
5. En cas de relais court-circuitĂŠ, remplacer le module de commande du
gestionnaire de l’appareil Copernicus. Passer à l’étape9.
6. Si tout est correct, débrancher le connecteurP3 du gestionnaire de
l’appareil Copernicus.
7. Mesurer la rĂŠsistance du capteur du four. Elle doit ĂŞtre comprise entre
1000Ω et 1200Ω à 77°F (25°C).
8. Vérier que le capteur n’est pas court-circuité à la masse. Si les contrôles
sur le capteur ne sont pas corrects, le remplacer et reprendre les contrĂ´les.
9. RÊinstaller les pièces et panneaux avant de faire la mise en marche.
10. Brancher le four ou reconnecter la source de courant ĂŠlectrique.
11. Accéder au menu de diagnostic et sélectionner “Sensors & Switches”
(capteurs et contacteurs) pour vérier si la température du four
correspondante sur l’afcheur est correcte (température ambiante). Sielle
ne l’est pas, débrancher le four ou déconnecter la source de courant
électrique et remplacer la carte du gestionnaire de l’appareil Copernicus.
REMARQUE: Sur l’écran de l’état, l’unité de mesure est en Celsius.
12. RÊinstaller les pièces et panneaux avant de faire la mise en marche.
13. Brancher le four ou reconnecter la source de courant ĂŠlectrique.
14. Vérier que le fonctionnement est normal. Accéder au mode de
diagnostic, sélectionner “Error Diagnostics” (diagnostic d’erreur) et
effacer l’historique.
K11
K10
K2
K3
PX4
PX1
PX3
Gestionnaire de l’appareil Copernicus
BL
BL
R
JYL
BU
RD
R R
N
N
Cuisson au gril – 4 000 W
Cuisson au four – 2 800 W
Cuisson convection – 3 200 W
Limiteur thermique
TempÊrature four 338 °F (170 °C)
ROJ/BL
N L2 L1
1
2
1
2
3
4
1
2
Gestionnaire de
l’appareil Copernicus
Capteur
tempĂŠrature
du four
V
V1
2
3
4
5
6
7
8
9
10
P3
À L’USAGE DU TECHNICIEN DE MAINTENANCE SEULEMENT
54
DÉFAILLANCE ERREUR DÉFAILLANCE PROBABLE
F6 E4 Non-concordance de statut d’état entre
interface utilisateur et gestionnaire de l’appareil
ACTION CORRECTIVE SUGGÉRÉE
REMARQUE: Avant de commencer un test, couper l’alimentation du four et
la rétablir (éteindre, patienter 10secondes et rallumer).
MÉTHODE: Avant de poursuivre, vérier le code d’erreur en entrant le mode
de diagnostic et sélectionnant “Error Diagnostics” (diagnostic d’erreur).
REMARQUE: Si d’autres codes d’erreur sont stockés, s’occuper d’abord de
ces autres codes d’erreur.
1. Débrancher le four ou couper l’alimentation électrique.
2. Remplacer le gestionnaire de l’appareil Copernicus.
3. RÊinstaller les pièces et panneaux avant de faire la mise en marche.
4. Brancher le four ou reconnecter la source de courant ĂŠlectrique.
5. Couper puis relancer l’alimentation. Si l’erreur est toujours présente après
avoir remplacé le gestionnaire de l’appareil Copernicus, débrancher le
four ou déconnecter la source de courant électrique. Passer à l’étape7.
6. Si l’erreur a disparu, passer à l’étape10.
7. Remplacer la carte HMI-central/IU.
8. RÊinstaller les pièces et panneaux avant de faire la mise en marche.
9. Brancher le four ou reconnecter la source de courant ĂŠlectrique et suivre
les messages à l’écran pour la sélection du modèle.
10. Vérier que le fonctionnement est normal. Si tel n’est pas le cas, passer à
l’étape14. Si l’erreur est toujours présente, passer à l’étape11.
11. Débrancher le four ou couper l’alimentation électrique.
12. Remplacer le tableau de commande.
13. Brancher le four ou reconnecter la source de courant ĂŠlectrique.
14. Suivre les messages à l’écran pour la sélection du modèle.
15. Vérier que le fonctionnement est normal. Accéder au mode de
diagnostic, sélectionner “Error Diagnostics” (diagnostic d’erreur) et
effacer l’historique.
DÉFAILLANCE ERREUR DÉFAILLANCE PROBABLE
F6 E8 Perte de communication avec le gestionnaire
du four Ă  micro-ondes
ACTION CORRECTIVE SUGGÉRÉE
REMARQUE: Avant de commencer un test, couper l’alimentation du four et
la rétablir (éteindre, patienter 10secondes et rallumer).
MÉTHODE: Avant de poursuivre, vérier le code d’erreur en entrant le mode
de diagnostic et sélectionnant “Error Diagnostics” (diagnostic d’erreur).
1. S’assurer que le four est branché. Ouvrir la porte du four à micro-ondes
pour vérier si la lampe s’allume.
2. S’assurer que le mode Sabbat est désactivé.
3. Débrancher le four ou couper l’alimentation électrique.
4. Vérier la connexion entre la carte de l’interface utilisateur broche J15-2
(jaune) et J15-3 (orange) et le gestionnaire du four Ă  micro-ondes broche
P26-3 (orange) et P26-4 (jaune).
5. Si le faisceau est correct, remplacer le gestionnaire du four Ă  micro-ondes.
6. RÊinstaller les pièces et panneaux avant de faire la mise en marche.
7. Brancher le four ou reconnecter la source de courant ĂŠlectrique.
8. Si l’erreur se reproduit, débrancher le four ou déconnecter la source de
courant ĂŠlectrique et remplacer la carte HMI-central/IU.
9. RÊinstaller les pièces et panneaux avant de faire la mise en marche.
Interface utilisateur
Gestionnaire
dÊappareil du four à
micro-ondes
P26
4321
543
21
J
OJ15
Comm. WIDE alim.
J
O
55
10. Brancher le four ou reconnecter la source de courant ĂŠlectrique.
11. Suivre les instructions à l’écran pour sélectionner le numéro de modèle si
l’interface utilisateur a été remplacée.
12. Vérier que le fonctionnement est normal. Accéder au menu de diagnostic
sélectionner “Error Diagnostics” (diagnostic d’erreur) et effacer l’historique.
ANOMALIE
(les 2 chiffres
les plus Ă 
gauche sur
l’horloge)
ERREUR
(les 2 chiffres
les plus Ă 
droite de
l’horloge)
DÉFAILLANCE PROBABLE
F8
E0 Le produit n’est pas branché correctement
E1 Vitesse trop ĂŠlevĂŠe de la vitesse basse du
ventilateur
E2 Vitesse trop lente de la vitesse ĂŠlevĂŠe du
ventilateur
E3 Vitesse trop ĂŠlevĂŠe de la vitesse ĂŠlevĂŠe du
ventilateur
MESSAGE DE VITESSE BASSE DU VENTILATEUR SUR LE FOUR
SIMPLE/DOUBLE: Le produit a rencontré un problème et ne peut plus être
utilisĂŠ.
ACTION CORRECTIVE SUGGÉRÉE
1. Débrancher le four ou couper l’alimentation électrique.
2. Attendre au moins 30 secondes.
3. Brancher le four ou reconnecter la source de courant ĂŠlectrique.
4. Accéder au mode de diagnostic et naviguer jusqu’à la liste d’activation de
composants.
5. Activer la vitesse basse du ventilateur de refroidissement.
6. Vérier la tension d’entrée aux brochesP5-5 et neutre pour la vitesse
élevée du ventilateur, puis aux brochesP5-4 et neutre pour la vitesse
basse du ventilateur pendant que le ventilateur de refroidissement
fonctionne en effectuant les ĂŠtapes suivantes.
7. Débrancher le four ou couper l’alimentation électrique.
8. Brancher l’appareil de mesure de tension.
9. Brancher le four ou reconnecter la source de courant ĂŠlectrique. Mesurer
la tension et conrmer que la lecture de tension est de 120V. Si ce n’est
pas le cas, dĂŠbrancher le four ou dĂŠconnecter la source de courant
électrique et passer à l’étape13. Si tel est le cas, passer à l’étape10.
10. Vérier que la tension d’entrée aux brochesP4-1 et P4-2 est de 5 VCC.
Si ce n’est pas le cas, débrancher le four ou déconnecter la source
de courant électrique et passer à l’étape13. Si tel est le cas, passer à
l’étape11.
À L’USAGE DU TECHNICIEN DE MAINTENANCE SEULEMENT
56
11. Débrancher le four ou couper l’alimentation électrique.
12. Remplacer le ventilateur de refroidissement. Passer à l’étape15.
13. Contrôler l’intégrité de tous les conducteurs du câblage et des
connexions entre le gestionnaire du four et le ventilateur de
refroidissement. Vérier qu’il n’y a aucun court-circuit entre un
conducteur et le châssis. Si le câblage est coincÊ ou endommagÊ,
remplacer le faisceau de câblage du ventilateur de refroidissement.
Passer à l’étape15. Si le câblage est en bon état, passer à l’étape14.
14. Remplacer le gestionnaire du four. Passer à l’étape15.
15. Replacer pièces et panneaux avant de faire la mise en marche.
16. Brancher le four ou reconnecter la source de courant ĂŠlectrique.
17. Accéder au mode de diagnostic et vérier que la vitesse du ventilateur
fonctionne dans le four. (Vitesse élevée: 1000 à 3300, vitesse basse:
400 à 3000)
Une fois la vérication de vitesse du ventilateur terminée, retourner à la liste
d’activation, activer la vitesse élevée du ventilateur de refroidissement, puis
retourner à l’écran “More Information” (plus d’informations) pour connaître la
vitesse du ventilateur.
DÉFAILLANCE ERREUR DÉFAILLANCE PROBABLE
F9 E0 Le produit n’est pas branché correctement
ACTION CORRECTIVE SUGGÉRÉE
REMARQUE: Avant de commencer un test, couper l’alimentation du four et
la rétablir (éteindre, patienter 10secondes et rallumer).
MÉTHODE: Avant de poursuivre, vérier le code d’erreur en entrant le mode
de diagnostic et sélectionnant “Error Diagnostics” (diagnostic d’erreur).
1. Débrancher le four ou couper l’alimentation électrique.
2. Accéder au câblage électrique depuis la source d’alimentation électrique
du domicile vers le four.
3. Vérier que le câblage du domicile est correct. Vérier si la connexion
neutre est connectĂŠe avec L1 ou L2 (consulter les instructions
d’installation pour le câblage du produit).
4. RÊinstaller les pièces et panneaux avant de faire la mise en marche.
5. Brancher le four ou reconnecter la source de courant ĂŠlectrique.
6. Vérier que le fonctionnement est normal en lançant une fonction
de cuisson. Accéder au mode de diagnostic, sélectionner “Error
Diagnostics” (diagnostic d’erreur) et effacer l’historique.
K4
K6
K7
K8 P5
J
O
GR
GR/N
Ventilateur de refroidissement VÉ
Ventilateur de refroidissement VB
Ventilateur de convection
Moteur du loquet de porte
1
2
3
4
5
6
7
Capteur Ă 
effet Hall
(ventilateur de
refroidissement)
Gestionnaire
de l’appareil
Copernicus
3
2
1
P1
P2
P3 GR GY
J
YL
T ERR E GN P4
À L’USAGE DU TECHNICIEN DE MAINTENANCE SEULEMENT
58
Four infĂŠrieur
A
I
J
G
H
F
B
F
C
D
E
A. HMI-Central/carte IU
B. Ventilateur de refroidissement
C. Capteur thermomĂŠtrique du four
D. Ensemble de convection
E. Limiteur thermique
F. Lampe
G. Élément de cuisson (non visible)
H. Élément de cuisson au gril
I. Loquet de porte
J. Tableau de commande
59
Logique du relais du ventilateur de refroidissement
Ventilateur du four
Ă  vitesse ĂŠlevĂŠe
(principal/supĂŠrieur
ou infĂŠrieur)
Ventilateur du four
Ă  vitesse faible
(principal/supĂŠrieur
ou infĂŠrieur)
Cuisson au four – froid – O
Cuisson au four – chaud – O
Cuisson au four –
trèschaud O –
Autonettoyage du four O –
LÉGENDE
Cold
(froide) Température du four inférieure à 212°F (100°C).
Faire
chauffer Température comprise entre 212°F et 599°F (100°C et 315°C).
Très
chaud Température du four supérieure à 599°F (315°C).
Mode
Cuisson
au four
Cuisson
au gril
Anneau de
convection
Ventilateur de
convection
Cuisson par convection
de pizza surgelĂŠe C C C O
Cuisson de pâtisseries
par convection C C C C
RĂ´tissage lent par
convection, 12 heures C C C O
RĂ´tissage lent par
convection, 8 heures C C C O
RĂ´tissage lent par
convection, 4 heures C C C O
RĂ´tissage par convection
C C C O
Cuisson au gril par
convection – C – C
Cuisson au four par
convection C C C C
Cuisson au four
par convection –
PrĂŠchauffage rapide C C C C
Cuisson au four C C C C
Cuisson au gril – C – –
Maintien au chaud C C – C
Levée rapide C C – –
Levée C C – –
Autonettoyage C C – –
LÉGENDE
Relais
inactif Relais actif/inactif
en alternance Relais
actif Non disponible
– C O N. D.
À L’USAGE DU TECHNICIEN DE MAINTENANCE SEULEMENT
60
Tableau de test des composants – Four
Pour mesurer correctement la tension, procéder aux étapes suivantes:
1. Débrancher le four ou couper l’alimentation électrique.
2. Brancher l’instrument de mesure de la tension aux points de contrôle.
3. Brancher le four ou reconnecter la source de courant électrique et vérier
la tension.
4. Débrancher le four ou couper l’alimentation électrique.
Composant Côté accessible Résultats – résistance Résultats – tensionPoints de contrôle Copernicus
Lampes Avant P7-1 à L1 (J8-1) 0-40 Ω 120V
Contacteur de loquet Avant P3-7 Ă  P3-5 Circuit ouvert
Contacteur porte Avant P3-6 Ă  P3-5 Circuit fermĂŠ avec la porte du four
ouverte
Moteur du loquet Avant P5-1 à N (J8-2) 500-3 000Ω 120 V – le moteur fonctionne
Capteur température du four Avant P3-1 à P3-2 1075Ω à 68°F (20°C), relais disj. bipol.
Sonde de cuisson Côté P3-3 à P3-4 9 876-10 075Ω
Moteur de ventilateur –
Vitesse élevée Arrière P5-5 à N (P7-1) 15-23 Ω 120 V – le moteur fonctionne
Moteur de ventilateur –
Vitesse basse Arrière P5-4 à N (J8-2) 15-23 Ω 120 V – le moteur fonctionne
Limiteur thermique Arrière PX3-1 à L2 (ligne principale) Circuit fermé 0 V – fermé, N.D. ouvert
Ventilateur de convection* Arrière P5-3 à N (J8-2) 16-20 Ω 120 V – le moteur fonctionne
Élément de convection* Avant PX1-3 à PX3-2 16,63-18,38Ω 240 V – programme de
cuisson par convection
enfonction
Élément de cuisson au four Arrière PX1-1 à PX3-2 19,0-21,6Ω 240 V – programme de
cuisson au four en fonction
Élément de cuisson au gril Avant PX4-2 à PX3-2 13,5-14,92Ω 240 V – programme de
cuisson au gril en fonction


Produktspezifikationen

Marke: JennAir
Kategorie: Herde
Modell: JMW2430LL

Brauchst du Hilfe?

Wenn Sie Hilfe mit JennAir JMW2430LL benĂśtigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Herde JennAir

Bedienungsanleitung Herde

Neueste Bedienungsanleitung fĂźr -Kategorien-