Indesit PI 640 TC (IX) GB Kookplaat Bedienungsanleitung

Indesit Kochfelder PI 640 TC (IX) GB Kookplaat

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Indesit PI 640 TC (IX) GB Kookplaat (12 Seiten) in der Kategorie Kochfelder. Dieser Bedienungsanleitung war für 9 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/12
GB
HOB
PI 640 A GB
PI 640 TC GB
Contents
Installation, 2-6
Positioning
Electrical connections
Gas Connection
Technical data
Characteristic of the burners and nozzles
Description of the appliance, 7
Overall view
Start-up and use, 8
Practical Advise on Using the Burners
Precautions and tips, 9
General safety
Disposal
Maintenance and care, 10
Switching the appliance off
Cleaning the appliance
Greasing the Taps
Assistance, 11
Operating Instructions
English, 1
GB
2
GB
! Before operating your new appliance please read this
instruction booklet carefully. It contains important
information for safe use, installation and care of the
appliance.
! Please keep these operating instructions for future
reference. Pass them on to possible new owners of the
appliance.
Positioning
! Keep packaging material out of the reach of children. It
can become a choking or suffocation hazard (see
Precautions and tips).
! The appliance must be installed by a qualified person
according to the instructions provided. Incorrect
installation may damage property or cause harm to
people or animals.
! This unit may be installed and used only in
permanently ventilated rooms according to the British
Stancards Codes Of Practice: B.S.î‚ 6172 / B.S.î‚ 5440,
Par. 2 and B.S. 6891 Current Editions. The following
requirements must be observed:
î‚• The hob should not be installed in a bed sitting
room with a volume of less than 20m3. If it is
installed in a room of volume less than 5m3 an air
vent of effective area of 110cm2 is required, if it is
installed in a room of volume between 5m3 and
10m3 an air vent of effective airvent of 50cm2 is
required, while if the volume exceeds 11m3 no
airvent is required. However, if the room has a door
or a window which opens directly to the outside no
air vent is required even with the volume is between
5m3 and 11m3.
î‚• Intensive or prolonged use of the appliance could
mean that extra aeration is needed, such as the
opening of a window or a more powerful fan.
î‚• If there are other fuel burning appliances in the
same room, B.S. 5440 Part 2 Current Edition,
should be consulted to determine the requisite air
vent requirements.
Fitting the appliance
The appliance can be installed next to furniture units
which are no taller than the top of the cooker hob. The
wall in direct contact with the back panel of the cooker
must be made of non-flammable material. During
operation the back panel of the cooker could reach a
temperature of 50°C above room temperature. For
proper installation of the cooker, the following
precautions must be taken:
î‚• The hob may be located in a kitchen, a kitonen/diner
or bed sitting room, but not in a bathroom or shower
room.
î‚• The furniture standing next to the unit, that is higher
than the working boards, must be placed at least
600 mm from the edge of the board.
î‚• The minimum distance combustible material can be
fitted above the hob in line with the edges of the
hob is 420mm. If is fitted below 420mm a space of
50mm must be allowed from the edges of the hob.
The minimum distance combustible material
kitchen units can be fitted directly above the hob is
700mm.
î‚• The dimensions of the room for the furniture must
be those indicated in the figures. Fixing hooks are
provided which allow to place the hob plate on
work tops that measure from 20 to 40 mm in
thickness. To obtain a good fixing of the hob plate it
is advisable to use all the hooks supplied.
555 mm
55 mm
475 mm
Fastening Clamps - Assembly Diagram
20
30
Clamp Position for Clamp Position for
H=20mm H=30mm top top
Installation
Min. 600 mm.
HOOD
min. 6 0 mm. i 5 w th hood
min. 00 mm. i 7w tho tuhood
Min. 0 42 mm.
Min. 0 42 mm.
HOOD
min. 650 with hood
min. 00 witho t hood7 u
LESS T AN 42 H 0
LESS T AN 42 H 0
min. 50min. 50
GB
3
Front
40
Clamp Position for Back
H=40mm top
! Use the clamps contained in the "accessory kit."
î‚• In the event the cooktop is not installed above a
built-in oven, a wood panel must be inserted as
insulation. This panel must be placed at least 20
mm from the bottom of the cooktop itself.
Ventilation
When installing the cooktop above a built-in oven, the
oven should be placed on two wooden strips; in the
case of a joining cabinet surface, remember to leave a
space of at least 45 x 560 mm at the back (see
picture).
! The hob can only be installed above built-in
ovens provided with cooling ventilation.
Electrical connection
The cooktops fitted with a tripolar electrical supply
cord are designed to be be used with alternating
current according to the indications on the rating plate
located under the cooktop. The earthing wire can be
identified by its yellow-green colour.
In the case of installation over a built-in electric oven,
the electrical connections for the cooktop and oven
should be independent, not only for safety purposes,
but also to facilitate removal of one or both in the
future.
Electrical Connection for Gas Cooktop
Fit the supply cord with a standard plug for the
demand rate indicated on the rating plate or connect it
directly to the electrical mains. In the latter case, a
single pole switch must be placed between the
appliance and the mains, with a minimum opening
between the contacts of 3 mm in compliance with
current safety codes (the earthing wire must not be
interrupted by the switch). The power supply cord
must be positioned so that it does not reach a
temperature in excess of 50°C above room
temperature at any point.
! The installer must ensure that the correct electrical
connection has been made and that it is compliant
with safety regulations.
Before making the actual connection, make sure that:
î‚• The fuse and electrical system can withstand the
load required by the appliance;
î‚• That the electrical supply system is equiped with an
efficient earth hook-up according to the norms and
regulations prescribed by law;
î‚• That the plug or switch is easily accessible.
! The wires in the mains lead are coloured in
accordance with the following code:
Green & Yellow - Earth
Blue - Neutral
Brown - Live
As the colours of the wires in the mains lead may not
correspond with the coloured markings identifying the
terminals in your plug, proceed as follows:
Connect the Green & Yellow wire to the terminal
marked î‚“Eî‚” or or coloured Green or Green &
Yellow.
Connect the Brown wire to the terminal marked î‚“Lî‚” or
coloured Red.
Connect the Blue wire to the terminal marked î‚“Nî‚” or
coloured Black.
! The cable must not be bent or compressed.
! The cable must be checked regularly and replaced
by authorised technicians only (see Assistance).
! The manufacturer declines any liability should
these safety measures not be observed.
560 mm.
45 mm.


Produktspezifikationen

Marke: Indesit
Kategorie: Kochfelder
Modell: PI 640 TC (IX) GB Kookplaat

Brauchst du Hilfe?

Wenn Sie Hilfe mit Indesit PI 640 TC (IX) GB Kookplaat benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Kochfelder Indesit

Bedienungsanleitung Kochfelder

Neueste Bedienungsanleitung für -Kategorien-