Owner’s Manual
English: Page 1
Mode d’emploi
Français : Page 6
Manual de Uso
Español: Página 11
T87N/T87K
The Round®
® U.S. Registered Trademark. U.S. Patents 7,159,789;
7,159,790; 7,476,988 and other patents pending.
Copyright © 2009, Honeywell International Inc.
All rights reserved.
69-1958EFS-02
The Round®
Check package contents:
• Thermostat
• Wallanchors&screws(2each)
Before you begin, make sure
you have:
• No.2Phillips&smallpocketscrewdrivers
• Hammer
• Level(optional)
• Pencil
• Drillandbit(3/16”fordrywall,7/32”
forplaster)
MERCURY NOTICE
Ifthisproductisreplacingacontrolthatcontainsmercuryinasealedtube,donot
placetheoldcontrolinthetrash.Contactyourlocalwastemanagementauthorityfor
instructions regarding recycling and proper disposal.
CAUTION: ELECTRICAL HAZARD
Cancauseelectricalshockorequipmentdamage.Disconnectpowerbefore
beginninginstallation.
Must be installed by a trained, experienced technician
Readtheseinstructionscarefully.Failuretofollowtheseinstructions
can damage the product or cause a hazardous condition.
Pre-installation checklist
Thismanualcoversthefollowingmodels:
ThisthermostatcontainsaLithiumbatterywhichmaycontainPerchloratematerial.
Perchlorate Material—special handling may apply,
Seewww.dtsc.ca.gov/hazardouswaste/perchlorate
• Heat-onlyT87K • HeatandCoolT87N
T87N/T87K • Owner's Manual
69-1958EFS—02 2
System Types
• Gasoroilheat(T87K)
• Gas,oil,orelectricheatwithair
conditioning(T87N)
• Warmair,hotwater,high-efficiency
furnaces,heatpumps,steam,gravity
• Heatonly
• Heatonlywithfan(T87N)
• Heatonly,2-wire,and3-wirehot-water
valve(poweropenandclosevalves)
(T87K)
• Coolonly(T87N)
System Settings (T87N)
• Heat,Off,Cool
Fan Settings (T87N)
• Auto,On
Specifications
Temperature Range
• 40°to90°F(4.5°to32°C)
Shipping Temperature
• -20°to120°F(-28.9°to48.9°C)
Operating Relative Humidity
• 5%to90%(non-condensing)
Electrical Ratings
• Voltage:20–30VAC
• Runningcurrent:0.02–1.0A
Installthethermostatabout5feet(1.5m)abovethefloorinanarea
with good air circulation at average temperature.
Do not install in locations where the thermostat can be affected by:
• Draftsordeadspotsbehinddoorsandincorners
• Hotorcoldairfromducts
• Sunlightorradiantheatfromappliances
• Concealedpipesorchimneys
• Unheated/uncooledareassuchasanoutsidewallbehindthethermostat
NO
NO NO
Installation tips
Product application
Thisthermostatprovideselectroniccontrolof:
• 24VACheatingsystems(T87K)
• 24VACheatingandcoolingsystems(T87N)
English: Page 1 • Français : Page 6 • Español: Página 11
3 69-1958EFS—02
1. Pull wires through wire
hole. Position wallplate on
wall, level, and mark hole
positions.
2. Drillholes(3/16”fordrywall,
7/32”forplaster)andtapin
supplied wall anchors.
3. Pullwirethroughwallplate,
position over anchors, then
insert and tighten mounting
screws.Checklevelif
desired.
1. Loosenscrewterminals,insertwiresintoterminalblock,thenre-tightenscrews.
2. Pushexcesswirebackintothewallopening.
3. Plugthewallopeningwithnonflammableinsulationtopreventdraftsfromaffecting
thermostat operation.
Wiring
NOTES
R & Rc terminals (T87N)
Insingle-transformersystem,leavemetal
jumperinplacebetweenR&Rc. Remove
metaljumperiftwo-transformersystem.
Heat pump systems (T87N)
Ifwiringtoaheatpump,useasmallpiece
ofwire(notsupplied)toconnectterminalsW
and Y.
Wire specifications
Use18-gaugethermostatwire.Shieldedcable
is not required.
Wallplate installation
Terminal DesignationsT87N
W Heat relay.
Y Compressor contactor.
G Fanrelay.
O Heat pump changeover valve
energized in cooling.
Rc Cooling power. Connect to secondary
sideofcoolingsystemtransformer.
R Heating power. Connect to secondary
sideofheatingsystemtransformer.
B Heat pump changeover valve
energized in heating.
Terminal DesignationsT87K
W Heat relay.
R Power.Connecttosecondarysideof
heatingsystemtransformer.
Y Thisterminalcanbeusedforsome3-
wirehot-watervalvesystems(power
openandclosevalves).
R
W
Y


Produktspezifikationen

Marke: Honeywell
Kategorie: Thermostat
Modell: T87N The Round

Brauchst du Hilfe?

Wenn Sie Hilfe mit Honeywell T87N The Round benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Thermostat Honeywell

Bedienungsanleitung Thermostat

Neueste Bedienungsanleitung für -Kategorien-