Honeywell HUL570 series Bedienungsanleitung


Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Honeywell HUL570 series (28 Seiten) in der Kategorie Luftbefeuchter-Luftentfeuchter. Dieser Bedienungsanleitung war für 16 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/28
GETTING TO KNOW
YOUR COOL MIST
HUMIDFIER
Visible cool mist
With ultrasonic humidification,
a nebulizer vibrates at
ultrasonic frequency, breaking
water droplets into fine mist
Be careful not to over-humidify: Exceeding a
60% humidity level can cause condensation
around unit, on walls and on surfaces; if this
occurs, open a door and turn the humidifier
off or to a lower setting
Instruction Manual
HONEYWELL TOP FILL
COOL MIST HUMIDIFIER
MODEL HUL570 SERIES
Humidity Level
• The ideal indoor humidity level is 40-60%
Use a Honeywell Humidity Monitor
(not included) to check your indoor
humidity level
Demineralization Cartridge
A demineralization cartridge, designed to
fit in this humidifier, is available to help
reduce white dust in areas with hard water.
Save these instructions for future reference.
Visit www.HoneywellPluggedIn.com
or call 800-477-0457 for questions and
information about this humidifier
2 3
GETTING TO KNOW YOUR HUMIDIFIER
How It Works
Water is released into the Reservoir when the Float Paddle engages the Plunger at the bottom
of the Water Tank. A Nebulizer vibrates at ultrasonic frequency, breaking the water into a fine
mist. The mist is quietly propelled by a fan up a vertical Mist Chamber to the Mist Outlet where
the cool, visible mist enters the room. This humidifier will shut off when the water level is low
or when the tank is removed from the base.
IMPORTANT SAFETY
INSTRUCTIONS
READ AND SAVE THESE SAFETY
INSTRUCTIONS BEFORE USING
THIS HUMIDIFIER
When using electrical appliances, basic
precautions should always be followed to
reduce the risk of fire, electrical shock and
injury to people, including the following:
1. The humidifier should always be placed on a
firm, flat, waterproof surface at least four feet
(1.2m) away from bedside, 12 inches (30 cm)
from the wall and out of reach of patients,
children and pets. Be sure the humidifier is in
a stable position and the power cord is away
from heated surfaces and out of the way to
prevent the humidifier from being tipped over.
2. The humidifier should not be left unattended
in a closed room since air could become
saturated and leave condensation in front
of unit, on walls and furniture. Leave room
door partly open. Do not aim Mist Outlet
directly at children, walls or furniture.
3. Before using the humidifier, extend the cord
and inspect for any signs of damage. Do not
use the unit if the cord has been damaged.
Do not operate with power cord coiled or with
twist tie in place.
4. The humidifier has a polarized plug (one blade
is wider than the other) as a safety feature.
This plug will fit into a polarized outlet only
one way. If the plug does not fit fully into the
outlet, reverse the plug. If it still does not fit,
contact a qualified electrician. Do not attempt
to defeat this safety feature.
5. CAUTION: To avoid fire or shock
hazard, plug the humidifier directly into a
120V AC electrical outlet. To avoid risk of
fire, shock or personal injury do not use an
extension cord or power strip.
6. The humidifier should always be
unplugged and emptied when not in
operation or while being cleaned. Shut
off and unplug humidifier before moving.
Do not move or tilt humidifier while it is
in operation. Plug and unplug unit with
dry hands. Never pull by cord.
7. Do not operate the humidifier without
water. Turn off and unplug unit when
tank is empty.
8. Humidifier requires regular cleaning. Refer
to and follow cleaning instructions.
9. Do not operate outdoors; this humidifier
is intended for indoor residential use only.
10. Do not cover or insert objects into any
openings on the unit.
11. Do not block intake or output vents.
12. Do not attempt to repair or adjust any
electrical or mechanical functions on
this humidifier. Doing so will void your
warranty.
13. Do not place in direct sunlight, high
temperature areas or near computers or
sensitive electronic equipment.
14. Do not touch the nebulizer while the unit is
plugged in, as burns could result.
15. Do not add any medications (e.g. liquid
inhalant, Vicks VapoSteam® or oils)
into Mist Outlet, Water Reservoir or
Water Tank.
SAVE THESE INSTRUCTIONS
13 Demineralization
Cartridge
(included in some models)
14 Plunger
15 Tank Gasket
16 Float Paddle
17 Air Outlet
18 Water Reservoir
19 Nebulizer
1 Mist Outlet
2 Outlet Gasket
3 Outlet Cover
4 Tank Handle
5 Tank Opening
6 Tank Cover
7 Water Tank
8 Auto Shut-Off Float
9 Housing
10 Base
11 Power Knob
12 Mist Chamber
Unpack the Humidifier
Keep this instruction manual for reference.
1. Remove packaging
materials. Locate
Float Paddle (A)
and set aside.
This is required for
operation.
2. Locate the Demineralization Cartridge (B) (included with some models) and set aside.
This is optional for operation.
3. Remove twist tie and extend power cord. Place on a firm, level, water resistant surface
a minimum of 12 inches (30 cm) from walls.
SETTING UP YOUR HUMIDIFIER
Components
MAX
MAX
10
1
2
3
4
9
7
6
5
14
13
8
17
12
19
18
16
15
11
Step 2 Step 1 Step 3
A
B
4 5
MAX
FILLING/REFILLING THE WATER TANK
SETTING UP YOUR HUMIDIFIER (CONTINUED) SETTING UP YOUR HUMIDIFIER (CONTINUED)
Option 2
This humidifier uses a float system to regulate the water flow from the Tank to the Reservoir.
The Float Paddle must be properly installed for the unit to operate. If not properly installed,
water may not flow into the Reservoir or it may leak from the Base. The Float Paddle is
designed to be easy to install and remove.
CAUTION: Improper placement of the Float Paddle could result in leaking or water
not feeding to the Reservoir.
1. Remove Water Tank.
2. Line up Float Paddle with the float paddle shape on the bottom of the Reservoir.
3. Place Float Rod over both Brackets and press firmly until you hear it click into
both Brackets.
4. Pull gently up on the Float Rod to be sure it doesn’t pop out of the Brackets.
5. Replace Tank in Base.
If using the optional demineralization cartridge, see next section Installing
Demineralization Cartridge.
Float Paddle Installation – required for humidifier to operate
High mineral content in your water, also known as hard water, may cause a white mineral
residue to accumulate on surfaces in the room near the humidifier. This mineral residue is
commonly referred to as white dust. The higher the mineral content (hardness) of your water,
the greater the potential that an ultrasonic humidifier may produce white dust.
White dust is not a result of a defect or flaw in the humidifier. It is a result of the amount of
minerals suspended in the water you are using.
Hard Water and White Dust
If you live in a hard water area, the use of distilled water or a demineralization cartridge
with tap water will help minimize the production of white dust. A Honeywell demineralization
cartridge (HDC500) is included with some humidifier models. To install it:
1. Remove Tank Cover.
2. Press the Cartridge into the recessed area inside the Water Tank and twist to secure.
3. Fill Tank with water according to instructions in the next section, Filling/Refilling the Water Tank.
Note: With a new, dry cartridge, there may be a delay of a few minutes while the water begins to
pass through the cartridge.
For best results, replace your Demineralization Cartridge every 20-30 fillings, or when you
begin to notice white dust forming. For your convenience, write the month and day you
installed the new cartridge on the top with a permanent marker.
To replace, twist the Cartridge and lift to remove. Dispose of in household trash. Replace with a
new Honeywell HDC500 or Protec TWT500 Demineralization Cartridge (not available in Canada).
Installing Demineralization Cartridge – optional
Top Le Haut
Step 2
Step 5
Step 4
This humidifier holds a maximum of 1.25 gallons (4.7 liters) of water.
The Tank Cover is removable. You can fill the Tank with the Cover in place or with the Cover
removed. Be sure to replace the Cover before using the humidifier to keep objects and debris
out of the water.
The Tank can be filled in two ways:
Option 1: At the Humidifier Option 2: At the Sink
$
MAX
MAX
Step 3
Top Le Haut
“Click”
$
MAX
MAX
MAX
Step 2
Step 1 Step 3
$
Both filling options can be performed with or without the Tank Cover in place.
Note:
Ensure the Float Paddle has been placed correctly in the Reservoir before filling.
See Float Paddle Installation instructions if necessary
Manufacturer will not accept responsibility for property damage caused by water spillage.
Float
Rod
Float
Paddle
Brackets
Option 1
MAX
Step 1


Produktspezifikationen

Marke: Honeywell
Kategorie: Luftbefeuchter-Luftentfeuchter
Modell: HUL570 series

Brauchst du Hilfe?

Wenn Sie Hilfe mit Honeywell HUL570 series benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Luftbefeuchter-Luftentfeuchter Honeywell

Bedienungsanleitung Luftbefeuchter-Luftentfeuchter

Neueste Bedienungsanleitung für -Kategorien-