INSTALLATION INSTRUCTIONS
33-00229EF-05
HE105, HE205
Whole Home Bypass Humidifier
APPLICATION
This kit contains your new HE105 or HE205 Humidifier,
H6062 Digital Humidity Control and all the accessories
required for installation.
How Your Humidifier Works
Your humidifier uses the principle that vapor (evaporated
water) is created when warm air blows over a water-soaked
area. As the vapor circulates, the relative humidity rises.
Your humidity control monitors the relative humidity and
activates the humidifier accordingly. The humidifier has a
water supply that dispenses water evenly over a humidifier
pad. The warm dry air from the furnace passes over the
humidifier pad and picks up the moist air to circulate it
throughout your home.
Humidified air feels warmer and more comfortable so you
may be able to lower your thermostat heating setpoint,
which saves money on your heating fuel bills. The end
result is that your humidifier gives you a comfortable
environment that is also energy efficient.
Need Help?
For assistance with this product please visit
http://honeywellhome.com or call Customer Care toll-free
at 1-800-468-1502.
PREPARING FOR THE
INSTALLATION
Be sure to identify all the required (Table 1) accessories
(included) and make sure the appropriate tools are
available before beginning the installation.
Included in the box:
• Humidifier
• H6062 Digital Humidity Control
• Transformer
Canadian “C” models also include:
• 6 in. dia. bypass ducting (24 in.)
• 18 gauge thermostat wire (20 ft.)
• 1/4 in. (6.35 mm) OD feed water tubing (20 ft.)
• 1/2 in. (12.7 mm) ID drain tubing (10 ft.)
• Saddle valve
Required Tools
Tools required for installation include:
• Tin snip
• Screwdriver
• Pliers
• Adjustable or open-end wrench
• Drill
• Level
• 3/4 in. (19 mm) sheet metal drill bit
SPECIFICATIONS
Model specific specifications are shown in Table 1.
Operating Ambient Temperature
:
41 to 113 °F (5 to 45 °C)
Power Supply: 24 VAC / 60 Hz.
Power Consumption: 7 Watts with 24 Vrms
Water Pressure: 40 to 120 psi.
Orifice Output: .02 in. (0.5 mm)
Flow Rate at Nozzle: 4.7 GPH (18 L/hr.) under 120 psi
M36294A
Table 1. Specifications.
Model
Size
length Ă— width Ă— depth
Duct Opening
H Ă— W Pad Size
Evaporation
Output
HE105 15.16 Ă— 16.57 Ă— 9.47 in.
(385 Ă— 421 Ă— 240 mm)
9.43 Ă— 9.28 in.
(240 Ă— 236 mm)
10 Ă— 9.5 Ă— 1.5 in.
(254 Ă— 241 Ă— 38.1 mm) 12 GPD
HE205 18.30 Ă— 17.11 Ă— 9.59 in.
(465 Ă— 434 Ă— 243 mm)
12.63 Ă— 9.68 in.
(321 Ă— 246 mm)
13.125 Ă— 10 Ă— 1.5 in.
(333 Ă— 254 Ă— 38.1 mm) 17 GPD
HE105, HE205 WHOLE HOME BYPASS HUMIDIFIER
33-00229EF—05 2
Safety Definitions
These safety terms identify information you must read
prior to installing or operating the humidifier.
WARNING
Indicates a hazardous situation which, if not
avoided, could result in death or serious injury.
CAUTION
Indicates a hazardous situation which, if not
avoided, could cause bodily injury or property
damage.
Safety Precautions
Make sure you read and understand the following safety
hazards before installing, using, or working with the
humidifier:
WARNING
Serious Personal Injury Hazard.
Can cause electrical shock and injury from
moving parts.
Disconnect power and shut off water supply before
removing cover.
WARNING
Hazardous Voltage
Can cause personal injury or equipment damage.
Do not cut or drill into any air conditioning or
electrical accessory.
CAUTION
Chemical Hazard.
Can cause personal injury or equipment damage.
Do not use any line connected to an air conditioner.
Do not use gas line.
CAUTION
Temperature and Static Pressure Hazard.
Can cause property or equipment damage.
Locate humidifier where ambient temperature is
between 41 and 113 °F (5 to 45 °C).
Do not install humidifier where freezing
temperatures could occur.
Be sure supply plenum static pressure is no greater
than 0.4 in. wc and water pressure is no greater
than 120 psi.
CAUTION
Sharp Edges Installation Hazard.
Can cause personal injury.
Wear gloves and safety glasses.
IMPORTANT
Read and save these instructions.
Determining Best Location for Humidifier
• Select a location for the humidifier on the supply (warm
air stream) duct. See Fig. 1 for examples. Return duct
mounting is acceptable if there are space restrictions
on the supply duct. If you are mounting the humidifier
on the return duct, simply swap “return duct” for
“supply duct” throughout these instructions.
• Select a location that cannot damage the air
conditioner A-coil during installation.
• Do not locate the humidifier on the furnace body.
• Mount the humidifier in a conditioned space to prevent
freezing.
• Mount the humidifier at least 3 in. (78 mm) above the
furnace body to allow adequate space for the solenoid
valve and drain line.
Fig. 1. Typical humidifier installation locations.
M12248D
HORIZONTAL
DOWN
FLO
LOWBOY
HIGHBOY
HUMIDIFIER
BYPASS
COLLAR
HE105, HE205 WHOLE HOME BYPASS HUMIDIFIER
3 33-00229EF—05
Fig. 2. Typical humidifier installation locations.
Selecting Location for Humidistat
• Select a location for the humidistat on the return
plenum or on the wall in the living space.
• Mounting on the return plenum is the easiest
installation for the control wiring circuit.
• Make sure that the thermostat wire is adequate to
reach from the humidifier to the humidistat, and also
from the humidifier to the transformer. See “Wiring” on
page 5 for more information.
IMPORTANT
The humidistat must be mounted upstream from
the humidifier or bypass duct to ensure it is
properly sensing the relative humidity of the living
space. Locate the control at least 8 in. (203 mm)
upstream from the humidifier in the return air
duct. (See Fig. 3.)
Fig. 3. Selecting duct location for humidistat.
INSTALLATION
1. Turn off power to the air handling system at the
circuit breaker.
2. Draw a level line on the plenum in the selected
location.
IMPORTANT
Be sure the mounting template is level before
marking. Use of a small level is recommended.
3. Locate the template (form number 33-00210,
included in the box). For the HE105 model, cut out
the template along the dotted line. For the HE205
model, use the entire sheet as a template.
4. Tape the template in position and trace around the
template.
5. Remove the template and carefully cut the
rectangular opening using tin snips.
6. Disassemble the humidifier; remove the cover and
take out the humidifier pad assembly. See Fig. 4.
Fig. 4. Disassembling humidifier.
CHOOSE A LOCATION IN A CONDITIONED
SPACE THAT HAS ACCESS TO A WATER SUPPLY
PIPE. COLD OR HOT WATER CAN BE USED.
SELECT A SURFACE ON THE HVAC SUPPLY OR
RETURN DUCT WITH CLEARANCE FOR THE
SOLENOID VALVE, DRAIN LINE AND COVER
REMOVAL.
LOCATION MUST ALSO HAVE ACCESS TO 120
VAC POWER.
ENSURE THE LOCATION IS NEAR A DRAIN.
CONSULT LOCAL PLUMBING CODES FOR
PROPER DRAINAGE.
M33410
ALTERNATE
LOCATION
RETURN
AIR RETURN
AIR
6 IN (152 MM)
MINIMUM
15 IN (381 MM)
MINIMUM
BEST
LOCATION
RETURN
AIR DUCT M34579A
M31022B
WATER
FEED NOZZLE
FRAME
HUMIDIFIER
HOUSING
WATER
FEED TUBE
HUMIDIFIER
PAD ASSEMBLY
COVER
SIDEWALL
BY-PASS SIDEWALL