Honeywell FocusPRO TH6320 Bedienungsanleitung

Honeywell Thermostat FocusPRO TH6320

Lesen Sie kostenlos die đź“– deutsche Bedienungsanleitung fĂĽr Honeywell FocusPRO TH6320 (24 Seiten) in der Kategorie Thermostat. Dieser Bedienungsanleitung war fĂĽr 6 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/24
FocusPRO®
6000 Series
Installation
Instructions
Programmable
Digital
Thermostat
M29433
Wallplate installation
Remove the wallplate from the thermostat,
then follow directions below for mounting.
1. Remove battery holder.
2. Pull here to remove wallplate from new
thermostat.
3. Pull wires through wire hole.
4. Position wallplate on wall, level and mark
hole positions with pencil.
5. Drill holes at marked positions as shown
below, then tap in supplied wall anchors.
6. Place wallplate over anchors, insert and
tighten mounting screws.
7. Insert reference card.
Drill 7/32"
holes for
plaster.
Drill 3/16"
holes for
drywall.
Wire hole Mounting
screws
MCR29434
2
MCR29436
Power options
Wiring terminal designations
Shaded areas below apply to or as otherwise noted.only TH6320U/TH6220D
Keep wires in this
shaded
area
Connect C for primary AC power
(optional if batteries are installed).
Insert batteries for primary
or backup power.
Remove factory-
installed jumper
only for two-
transformer
systems.
Conventional Terminals:
Rc 24VAC power from cooling
transformer
R 24VAC power from heating
transformer
W Heat relay (stage 1)
W2 Heat relay (stage 2)
Y Compressor contactor (stage 1)
Y2 Compressor contactor (stage 2)
G Fan relay
C 24VAC common. For 2 transformer
systems, use common wire from
cooling transformer.
Heat Pump Terminals:
Rc 24VAC power from cooling
transformer
R 24VAC power from heating
transformer
O/B Changeover valve
Y Compressor contactor
Y2 Compressor contactor (stage 2)
-TH6320U only
G Fan relay
Aux/E Auxiliary/Emergency heat relay
L Sends output when set to Em. Heat
C 24VAC common
TH6110D
RcYWG RC
TH6220D
RcYWGW2Y2 RC
TH6320U
RcYWGW2Y2 RC
MCR29437A
TH6110D
RcYG RC
RcYG
L R
C
TH6220D
RcYGAux
E
Y2
L R
C
TH6320U
MCR29438A
Aux
E
3
Wiring conventional systems
Shaded areas below apply to or as otherwise noted.only TH6320U/TH6220D
1H/1C System
(1 transformer)
Rc [1]Power
R [R+Rc joined by jumper]
Y Compressor contactor
C 24VAC common [3]
W Heat relay
G Fan relay
Heat-only System
Rc [1]Power
R [R+Rc joined by jumper]
C 24VAC common [3]
W Heat relay
Heat-only System
(Series 20) [5]
Rc [R+Rc joined by jumper]
R [1]Series 20 valve terminal “R”
Y Series 20 valve terminal “W”
C 24VAC common [3]
W Series 20 valve terminal “B”
Heat-only System
(normally open zone
valve) [5]
Rc [R+Rc joined by jumper]
R [1]Power
Y Normally open zone valve
C 24VAC common [3]
1H/1C System
(2 transformers)
Rc Power (cooling transformer) [1, 2]
R Power (heating transformer) [1, 2]
Y Compressor contactor
C 24VAC common [3, 4]
W Heat relay
G Fan relay
Heat-only System
with Fan
Rc [1]Power
R [R+Rc joined by jumper]
C 24VAC common [3]
W Heat relay
G Fan relay
Cool-only System
Rc [1]Power
R [R+Rc joined by jumper]
Y Compressor contactor
C 24VAC common [3]
G Fan relay
2H/2C System
(1 transformer) [6]
Rc [1]Power
R [R+Rc joined by jumper]
Y Compressor contactor (stage 1)
C 24VAC common [3]
W Heat relay (stage 1)
G Fan relay
W2 Heat relay (stage 2)
Y2 Compressor contactor (stage 2)
2H/2C System
(2 transformers) [6]
Rc Power (cooling transformer) [1, 2]
R Power (heating transformer) [1, 2]
Y Compressor contactor (stage 1)
C 24VAC common [3, 4]
W Heat relay (stage 1)
G Fan relay
W2 Heat relay (stage 2)
Y2 Compressor contactor (stage 2)
RcYWG RC
RcW RC
RcYW RC
RcY RC
RcWG RC
RcYG RC
RcYWGW2Y2 RC
RcYWGW2Y2 RC
NOTES
Wire specifications:
Use 18- to 22-gauge thermostat wire.
Shielded cable is not required.
[1] Power supply. Provide disconnect means
and overload protection as required.
[2] Remove jumper for 2-transformer systems.
[3] Optional 24VAC common connection.
[4] Common connection must come from cool-
ing transformer.
[5] In Installer Setup, set system type to
Heat Only.
[6] In Installer Setup, set system type to
2Heat/2Cool Conventional.
[7] In Installer Setup, set changeover valve to
O or B.
[8] In Installer Setup, set system type to
2Heat/1Cool Heat Pump.
[9] In Installer Setup, set system type to
2Heat/2Cool Heat Pump.
[10] In Installer Setup, set system type to
3Heat/2Cool Heat Pump.
[11] L terminal sends a continuous output when
thermostat is set to Em. Heat. Connect
to Honeywell zoning panels to switch the
panel to Emergency Heat.


Produktspezifikationen

Marke: Honeywell
Kategorie: Thermostat
Modell: FocusPRO TH6320

Brauchst du Hilfe?

Wenn Sie Hilfe mit Honeywell FocusPRO TH6320 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Thermostat Honeywell

Bedienungsanleitung Thermostat

Neueste Bedienungsanleitung fĂĽr -Kategorien-