Hitachi RAC-63CHA3 Bedienungsanleitung

Hitachi Klimaanlage RAC-63CHA3

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Hitachi RAC-63CHA3 (26 Seiten) in der Kategorie Klimaanlage. Dieser Bedienungsanleitung war für 16 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/26
1
ENGLISH
SPLIT TYPE AIR CONDITIONER
INDOOR UNIT/OUTDOOR UNIT
MODEL
RAS-51CHA3/RAC-51CHA3
RAS-63CHA3/RAC-63CHA3
OUTDOOR UNIT INDOOR UNIT
RAS-51CHA3
RAS-63CHA3
Instruction manual Page 1~26
To obtain the best performance and ensure years of trouble free use, please read this instruction manual completely.
RAC-51CHA3
RAC-63CHA3
– – 2
!
SAFETY PRECAUTION
Please read the Safety Precaution carefully before operating the unit to ensure correct usage of the unit.“ ”
Pay special attention to signs of and . The section contains matters which,“ ” Warning “ ” Caution “ ”Warning
if not observed strictly, may cause death or serious injury. The section contains matters which may“ ”Caution
result in serious consequences if not observed properly. Please observe all instructions strictly to ensure safety.
The sign indicate the following meanings.
Please keep this manual after reading.
WARNING
PRECAUTIONS DURING INSTALLATION
Do not reconstruct the unit.
Water leakage, fault, short circuit or fire may occur if you reconstruct
the unit by yourself.
Please ask your sales agent or qualified technician for the installation
of your unit. Water leakage, short circuit or fire may occur if you install
the unit by yourself.
Please use earth line.
Do not place the earth line near water or gas pipes, lightning-conductor,
or the earth line of telephone. Improper installation of earth line may
cause electric shock.
A circuit breaker should be installed depending on the mounting site of
the unit. Without a circuit breaker, the danger of electric shock exists.
Do not install the unit near a location where there is flammable gas.
The outdoor unit may catch fire if ammable gas leaks around it.
Please ensure smooth flow of water when installing the drain hose.
CAUTION
!
!
PRECAUTIONS DURING SHIFTING OR MAINTENANCE
Should abnormal situation arises (like burning smell), please stop operating the unit
and turn off the circuit breaker. Contact your agent. Fault, short circuit or fire may
occur if you continue to operate the unit under abnormal situation.
Please contact your agent for maintenance. Improper self maintenance may cause
electric shock and fire.
Please contact your agent if you need to remove and reinstall the unit. Electric
shock or fire may occur if you remove and reinstall the unit yourself improperly.
!
Make sure to connect earth line.
Indicates the instructions that must be followed.
The sign in the figure indicates prohibition.
W
A
R
N
I
N
G
!
PRECAUTIONS DURING OPERATION
Avoid an extended period of direct air flow for your health.
W
A
R
N
I
N
G
!
Do not insert a nger, a rod or other objects into the air outlet or inlet. As the
fan is rotating at a high speed, it will cause injury. Before cleaning, be sure
to stop the operation and turn the breaker OFF.
During thunder storm, disconnect and turn off the circuit breaker.
Do not use any conductor as fuse wire, this could cause fatal accident.
This unit has UV LED which emits ultra violet light.
AVOID DIRECT EYE EXPOSURE.
!
– – 3
ENGLISH
PRECAUTIONS DURING OPERATION
Do not attempt to operate the unit with wet hands, this could cause fatal
accident.
When operating the unit with burning equipments, regularly ventilate the
room to avoid oxygen insufficiency.
Do not direct the cool air coming out from the air-conditioner panel to face
household heating apparatus as this may affect the working of apparatus
such as the electric kettle, oven etc.
Do not place plants directly under the air flow as it is bad for the plants.
Please ensure that outdoor mounting frame is always stable, firm and
without defect. If not, the outdoor unit may collapse and cause danger.
Do not splash or direct water to the body of the unit when cleaning it as this
may cause short circuit.
When operating the unit with the door and windows opened, (the room humidity is always above
80%) and with the air deflector facing down or moving automatically for a long period of time,
water will condense on the air deflector and drips down occasionally. This will wet your furniture.
Therefore, do not operate under such condition for a long time.
If the amount of heat in the room is above the cooling or heating capability of the unit (for
example: more people entering the room, using heating equipments and etc.), the preset room
temperature cannot be achieved.
Do not climb on the outdoor unit or put objects on it.
Please switch off the unit and turn off the circuit breaker during cleaning, the
high-speed fan inside the unit may cause danger.
Turn off the circuit breaker if the unit is not to be operated for a long period.
C
A
U
T
I
O
N
!
The product shall be operated under the manufacturer specification and
not for any other intended use.
Do not put water container (like vase) on the indoor unit to avoid water
dripping into the unit. Dripping water will damage the insulator inside the unit
and causes short-circuit.
Do not use any aerosol or hair sprays near the indoor unit. This chemical
can adhere on heat exchanger fin and blocked the evaporation water ow
to drain pan. The water will drop on tangential fan and cause water splashing
out from indoor unit.


Produktspezifikationen

Marke: Hitachi
Kategorie: Klimaanlage
Modell: RAC-63CHA3

Brauchst du Hilfe?

Wenn Sie Hilfe mit Hitachi RAC-63CHA3 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Klimaanlage Hitachi

Bedienungsanleitung Klimaanlage

Neueste Bedienungsanleitung für -Kategorien-