Hikvision DS-PKA-WLM-433 Bedienungsanleitung


Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Hikvision DS-PKA-WLM-433 (1 Seiten) in der Kategorie Sicherheitszugangskontrollsystem. Dieser Bedienungsanleitung war für 44 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/1
3. Secure the mounng plate on the wall with four supplied
4. Rotate the keypad body clockwise to fasten the body on the
1. Loosen the set screws on boom of the keypad.
2. Rotate an-clockwise to remove the mounng plate.
It is required to insert the screw for tamper alarm.
5. Tighten the screw on the boom to fix the keypad on the mounng
plate and complete the installaon.
COPYRIGHT ©2019 Hangzhou Hikvision Digital Technology
Co., Ltd.
ALL RIGHTS RESERVED.
Any and all informaon, including, among others, wordings,
pictures, graphs are the properes of Hangzhou Hikvision
Digital Technology Co., Ltd. or its subsidiaries (hereinaer
referred to be “Hikvision”). This user manual (hereinaer
referred to be “the Manual”) cannot be reproduced,
changed, translated, or distributed, parally or wholly, by
any means, without the prior wrien permission of
Hikvision. Unless otherwise spulated, Hikvision does not
make any warranes, guarantees or representaons,
express or implied, regarding to the Manual.
About this Manual
This Manual is applicable to Alarm Keypad.
The Manual includes instrucons for using and managing
the product. Pictures, charts, images and all other
informaon hereinaer are for descripon and explanaon
only. The informaon contained in the Manual is subject to
change, without noce, due to firmware updates or other
reasons. Please find the latest version in the company
website (hp://overseas.hikvision.com/en/).
Please use this user manual under the guidance of
professionals.
Legal Disclaimer
TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW,
THE PRODUCT DESCRIBED, WITH ITS HARDWARE, SOFTWARE
AND FIRMWARE, IS PROVIDED “AS IS”, WITH ALL FAULTS AND
ERRORS, AND HIKVISION MAKES NO WARRANTIES, EXPRESS
OR IMPLIED, INCLUDING WITHOUT LIMITATION,
MERCHANTABILITY, SATISFACTORY QUALITY, FITNESS FOR A
PARTICULAR PURPOSE, AND NON-INFRINGEMENT OF THIRD
PARTY. IN NO EVENT WILL HIKVISION, ITS DIRECTORS,
OFFICERS, EMPLOYEES, OR AGENTS BE LIABLE TO YOU FOR
ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT
DAMAGES, INCLUDING, AMONG OTHERS, DAMAGES FOR
LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, OR
LOSS OF DATA OR
Trademarks Acknowledgement and other
Hikvision’s trademarks and logos are the properes of
Hikvision in various jurisdicons. Other trademarks and
logos menoned below are the properes of their
respecve owners.
DOCUMENTATION, IN CONNECTION WITH THE USE OF THIS
PRODUCT, EVEN IF HIKVISION HAS BEEN ADVISED OF THE
POSSIBILITY OF SUCH DAMAGES.
REGARDING TO THE PRODUCT WITH INTERNET ACCESS, THE
USE OF PRODUCT SHALL BE WHOLLY AT YOUR OWN RISKS.
HIKVISION SHALL NOT TAKE ANY RESPONSIBILITES FOR
ABNORMAL OPERATION, PRIVACY LEAKAGE OR OTHER
DAMAGES RESULTING FROM CYBER ATTACK, HACKER
ATTACK, VIRUS INSPECTION, OR OTHER INTERNET SECURITY
RISKS; HOWEVER, HIKVISION WILL PROVIDE TIMELY
TECHNICAL SUPPORT IF REQUIRED.
SURVEILLANCE LAWS VARY BY JURISDICTION. PLEASE CHECK
ALL RELEVANT LAWS IN YOUR JURISDICTION BEFORE USING
THIS PRODUCT IN ORDER TO ENSURE THAT YOUR USE
CONFORMS THE APPLICABLE LAW. HIKVISION SHALL NOT BE
LIABLE IN THE EVENT THAT THIS PRODUCT IS USED WITH
ILLEGITIMATE PURPOSES.
IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL
AND THE APPLICABLE LAW, THE LATER PREVAILS.
Enrollment
English
Diagram Reference
Product Information
Specification
Components and Indicaon
1
3
Installaon4
Operaon
5
Power On
2
1
2 4
5
3
Wireless Alarm Keypad
This product and - if applicable - the supplied
accessories too are marked with "CE" and comply
therefore with the applicable harmonized European
standards listed under the RE Direcve 2014/53/EU,
the EMC Direcve 2014/30/EU, the LVD Direcve
2014/35/EU, the RoHS Direcve 2011/65/EU.
2012/19/EU (WEEE direcve): Products marked
with this symbol cannot be disposed of as unsorted
municipal waste in the European Union. For proper
recycling, return this product to your local supplier
upon the purchase of equivalent new equipment, or
dispose of it at designated collecon points. For
more informaon see: www.recyclethis.info
The Input voltage should meet both the SELV (Safety
Extra Low Voltage) and the Limited Power Source
according to the IEC60950-1 standard. Please refer
to technical specificaons for detailed informaon.
Tamper Screw
1
2
3
4
5
2
3
1
1
3
21
Control
Panel
Power on the security control panel.
Make the control panel enter the
enrollment mode. Press the tamper
switch (on the board) of the keypad. The
paron indicators flashes 4 mes when
the keypad is enrolled and ready for
work.
Note: The distance between the security
control panel and the keypad should be
less than 50 cm.
1. Loosen the set screws on boom of the keypad.
2. Remove the mounng plate.
3. Install four AA baeries according to the polarity mark.
Note: Do not reverse the polarity of the baery.
Check Signal Strength
Enter the signal checking mode by operang on the control panel.
Trigger the tamper alarm.
Power indicator flashes 3 mes - Strong Signal
Fault indicator flashes 3 mes - Weak Signal
Buzzer
1. Indicator
2. Tag Area
3. TAMPER Switch (on the board)
Power
Indicator Green
Blue
Orange
Red
Keypad Backlight White Keypad locked: flashes 2 times
Turn off if no operation for 5 s, turn on when touched
Normal Battery: Solid green for 2s (keypad waked up)
Low Battery:Flashing green flashes 3 times (keypad waked up)
Weak Signal Strength:Flashes 3 times
Strong Signal Strength:Flashes 3 times
Armed: Related LED flashes once, and light on 2 s while
the keypad is waked up
Disarmed/Alarm Cleared:Related LED flashes twice
Operation failed: Related LED flashes 3 times
Alarm: Related LED flashes 30s
Enrolled and Strats work: 4 LEDs flashes 4 times together
Patrol card presented: Power and Fault LEDs flashes 2 times
Patrol card presented: Power and Fault LEDs flashes 2 times
Zone/ Fire Alarm Triggered:Flashes 30s
No Alarm or Alarm Restored:Off
Partition
Indicator
Fault
Indicator
Alarm
Indicator
Present Tag/Tap Key/Armed
Disarmed
Operation Failed
Keypad Tampered
Card Enrolled
Zone Tampered
Fire Alarm
Beep Beep Beep
Beep Beep Beep Beep Beep
Beep
Beep
Long Beep (30 s)
Long Beep (30 s)
Beep Beep
Formang
Remove the baery. Hold the TAMPER buon (with slend rod) and power
the keypad on at the same me. The power, alarm, fault indicators flashes
4 me aer the formang is completed.
Operation
All Partition
1 Enter the user password.
2. Tab the stay/away/disarm key.
Specified
Partition
1. Tab the user password.
2. Tab the √ key.
3.
Enter the partition No.(1/2/3/4).
4. Tab the stay/away/disarm key.
Partition
Keypad
Fire Alarm
Panic Alarm
Confirm
1.Enter the user password.
2.Tab the stay/away/disarm key.
Stay/Away Arming
Disarming
Global Keypad
Hold the fire alarm key for 3 s.
R ee 10.0 4.8F sp d kbps/ bps
R re uenc 433 H 8 8 HF f q y M z/ 6 M z
R metho 2G SF d F K
Tr n m on t nce 800m o en rea s issi dis a ( p a a)
Po er 10 mw dB
T m er roo 1 t m er tch, ront n re r ta p -p f a p sw f a d a am erp -p froo
Wi l ss M d l i a s wi l pa lre e o u e Commun c te th contro ne
Tag ad pp s s a da d re er Su ort t n r IC c ra d
B zzu er 1
Ser ort 1, re er eial p s v d
In c tordi a
3
t tu n c tor o er s a s i di a s: p w (g )reen , u t , n rm refa l ( )orange a d ala ( d)
4 r on n c tor rme rme uepa  i di a s: a d/disa d (bl )
Ba klig g pc ht 1 rou
N i k yumer c e 10, 0 to 9
F k y 6 fi away a i g s ay a i g dia i g d l  gunc on e , re, rm n , t rm n , rm n , e e n , n Oa d K
E ectr c & erl i al Ba y w Ba i s D y a s s a dbyPo er 4 AA er e 3V C 3 ,≥ e r t n
O er on hum t 10 to 90p a idi y % %
O er on tem er ture 10 to +55p a p a ﹣ ℃
Co or h te cl W i /Bla k
In t on moun n th cres alla Wall g wi s ws
Wi l ss K ypadre e e
RF
Interface n Com onenta d p
Others
Do not mix baeries of
different brands.
Do not mix old and new
baeries.
EN50131-1:2006+A2:2017
EN50131-3:2009E
N50131-5-3:2017
Security Grade 2
Environmental Class II
1. Log in to the Search for APP Store.
“Hik-Connect” .Download and install the
client to your phone. Run the client.
2. Power on the security control panel.
3. Log in the client and tap the icon “+”
to add the ontrol panel. Scan the QR
code or input the device serial No. to
add the device( in the registraon
mode).
4. Tap the “+” icon on the device page
to add the peripherals. .
Local Enrollment APP Enrollment
Present
Beep
Tag Sensed
Present Remove
Beep
Tag Sensed
Hold 3s,
remove aer a beep
1
2
Present
Beep
Tag Sensed
3System
Armed
Remove
Operang illegal tag
(unregistered tag)
more than 3 mes,
the device will be
locked for 90s.
Refer to the Components
and Indicaon
secon for indicator and
buzzer descripon.
1Away Arming
Other
Operaon
Tag Operaon 2Stay Arming 3Disarming
Delete Delete the latest key operation


Produktspezifikationen

Marke: Hikvision
Kategorie: Sicherheitszugangskontrollsystem
Modell: DS-PKA-WLM-433

Brauchst du Hilfe?

Wenn Sie Hilfe mit Hikvision DS-PKA-WLM-433 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Sicherheitszugangskontrollsystem Hikvision

Bedienungsanleitung Sicherheitszugangskontrollsystem

Neueste Bedienungsanleitung für -Kategorien-