Hatco FR-9 Bedienungsanleitung

Hatco Heizung FR-9

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Hatco FR-9 (4 Seiten) in der Kategorie Heizung. Dieser Bedienungsanleitung war für 14 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/4
© 2012 Hatco Corporation
Sanitizing Sink Heaters and
Food Rethermalizers/Bain-Marie Heaters
3CS and FR Series
Installation and Operating Manual
P/N 07.04.114.00
POWER
ON
LOW WATER
REFILL & RESET
PARTS & SERVICE
ASSIST ANCE
www.hatcocorp.com
800-558-0607
Fil l sin k befor e turn ing power on.
Disc onnect power before servicin g heat er.
RESET
ON
OFF
WATER HEATER
HA TCO CORP. MILWA UKEE, WI U.S. A
U.S. PAT. NO. 3291965 CAN. PAT. NO. 761083
POWER
ON
WATER AT
TEMPERA TURE
PARTS & SER
VICE
ASS ISTANCE
www .hatcocorp. com
800-558-0607
Fill sink before turni ng power on.
Drain and cl ean hea te
r dail y.
RESET
ON
OFF
WATER HEATER
HATCO CORP. MILWAUKEE, WI U.S.A
U.S. PAT
. NOS. 3291965 3636308
Do not operate this equipment unless you
have read and understood the contents of
this manual! Failure to follow the
instructions contained in this manual may
result in serious injury or death. This
manual contains important safety
information concerning the maintenance,
use, and operation of this product. If
you’re unable to understand the contents
of this manual, please bring it to the
attention of your supervisor. Keep this
manual in a safe location for future
reference.
No opere este equipo al menos que haya
leído y comprendido el contenido de este
manual! Cualquier falla en el seguimiento
de las instrucciones contenidas en este
manual puede resultar en un serio lesión
o muerte. Este manual contiene
importante información sobre seguridad
concerniente al mantenimiento, uso y
operación de este producto. Si usted no
puede entender el contenido de este
manual por favor pregunte a su
supervisor. Almacenar este manual en
una localización segura para la referencia
futura.
Ne pas utiliser cet équipement sans avoir
lu et compris le contenu de ce manuel !
Le non-respect des instructions
contenues dans ce manuel peut entraîner
de graves blessures ou la mort. Ce
manuel contient des informations
importantes concernant l'entretien,
l'utilisation et le fonctionnement de ce
produit. Si vous ne comprenez pas le
contenu de ce manuel, veuillez le signaler
à votre supérieur. Conservez ce manuel
dans un endroit sûr pour pouvoir vous y
référer plus tard.
WARNING
ADVERTENCIA
AVERTISSEMENT
Register Online!
(see page 2)
www.hatcocorp.com
Read the following important safety information before using this equipment to avoid serious injury or death and
to avoid damage to equipment or property.
ELECTRIC SHOCK HAZARD:
Units supplied without an electrical cord and plug
require a hardwired connection to on-site electrical
system. Connection must be properly grounded and of
correct voltage, size, and configuration for electrical
specifications of unit. Contact a qualified electrician to
determine and install proper electrical connection.
Units supplied with an electrical cord, plug, and
receptacle require installation of receptacle to on-site
electrical system. Connection must be properly
grounded and of correct voltage, size, and
configuration for electrical specifications of unit.
Contact a qualified electrician to determine and install
proper electrical connection.
Unit must be installed by qualified, trained installers.
Installation must conform to all local electrical and
plumbing codes. Installation by unqualified personnel
will void the unit warranty and may lead to electric
shock or burn, as well as damage to unit and/or its
surroundings. Check with local plumbing and electrical
inspectors for proper procedures and codes.
Unit is not weatherproof. Locate the unit indoors where
the ambient air temperature is a minimum of 70°F
(21°C).
Turn OFF power switch, unplug power cord/turn off
power at circuit breaker, and allow unit to cool before
performing any cleaning, adjustments, or maintenance.
DO NOT submerge or saturate with water. Unit is not
waterproof. Do not operate if unit has been submerged
or saturated with water.
Do not clean unit when it is energized or hot.
This unit is not “jet-proof” construction. Do not use jet-
clean spray to clean this unit.
Discontinue use if power cord is frayed or worn.
Do not attempt to repair or replace a damaged power
cord. Cord must be replaced by Hatco, an Authorized
Hatco Service Agent, or a person with similar
qualifications.
This unit must be serviced by qualified personnel only.
Service by unqualified personnel may lead to electric
shock or burn.
Use only Genuine Hatco Replacement Parts when
service is required. Failure to use Genuine Hatco
Replacement Parts will void all warranties and may
subject operators of the equipment to hazardous
electrical voltage, resulting in electrical shock or burn.
Genuine Hatco Replacement Parts are specified to
operate safely in the environments in which they are
used. Some aftermarket or generic replacement parts
do not have the characteristics that will allow them to
operate safely in Hatco equipment.
WARNING
FIRE HAZARD:
Install unit with a minimum of 3-1/2″ (89 mm) of space
from bottom of unit to all combustible surfaces to
prevent combustion.
Do not use harsh chemicals such as bleach (or cleaners
containing bleach), oven cleaners, or flammable
cleaning solutions to clean this unit.
Make sure all operators have been instructed on the safe
and proper use of the unit.
This unit is not intended for use by children or persons
with reduced physical, sensory, or mental capabilities.
Ensure proper supervision of children and keep them away
from the unit.
Hatco Corporation is not responsible for actual food
product serving temperature. It is the responsibility of the
user to ensure that food product is held and served at a
safe temperature.
This unit has no user-serviceable” parts. If service is
required on this unit, contact an Authorized Hatco Service
Agent or contact the Hatco Service Department at
800-558-0607 or 414-671-6350; fax 800-690-2966; or
International fax 414-671-3976.
BURN HAZARD:
Some exterior surfaces on unit will get hot. Avoid
unnecessary contact with unit.
Drain water may reach temperatures in excess of 200°F
(93°C). Use appropriate plumbing materials when
installing drain.
Water in holding vessel may reach temperatures in
excess of 190ºF (88ºC). Use appropriate protection
when operating unit.
Hot water in unit may cause scalding injury. Allow unit
to cool before draining or cleaning.
Do NOT set temperature control higher than 190ºF
(88ºC). Units are designed to heat water up to 190ºF
(88ºC). Water over 190°F (88°C) is very active and could
splash onto operator causing serious burns or injury.
Do not use extension pipes on the inlet and outlet
connections on water heater units. Poor performance or
unsafe conditions may occur.
WARNING
CAUTION
3
Form No. 3CSFRM-0112
IMPORTANT SAFETY INFORMATION
INSTALLATION
12 Form No. 3CSFRM-0112
3. Remove the template and cut a 2" (51 mm) diameter hole
at each pilot hole location using a knockout hole punch.
4. Make a 1/8" (3 mm) offset around each 2" (51 mm) diameter
hole. The offset should be a diameter of 3" (76 mm)
centered around the hole.
Side View of Hole and Offset
Installing the Drain Spud Assembly
5. Unscrew the drain spud assembly from the welded pipe on
the heater.
2”
(51 mm)
Dia. Hole
3”
(76 mm)
Dia. Oset
1/8”
(3 mm)
Oset
Height
Sink or Tank
Bottom
6. Unscrew the locknut from the drain spud assembly and slide
off all of the washers except the thin rubber washer.
7. With only the thin rubber washer attached to the drain spud,
slide the drain spud through the sink hole from above.
8. Secure the drain spud assembly to the sink or holding
vessel.
a. From under the sink, slide the two thick rubber washers
followed by the fiber washer onto the drain spud.
b. Screw the locknut (flat side up) onto the drain spud.
9. Repeat steps 5–8 for the other spud assembly.
10. Secure the unit to the sink or holding vessel. Two people
are required for this step.
a. Position the unit under the two spud assemblies.
NOTE: Make sure the union washers are positioned properly
inside the union nuts and are not crimped.
b. Screw the union nut to the threaded drain spud assembly.
Do not use excessive force when tightening unions or nuts.
Over-tightening and excessive force may cause leaks.
11. Tighten the union nuts and locknuts securely.
12. Fill the sink or holding vessel with water and check for leaks.
NOTE: A 3/4" (19 mm) hose or pipe may be connected to the
sump drain and run to an open sight drain. The sump
drain should not be permanently connected to the
sanitary drain system. Check local plumbing code for
proper drain installation. See the MAINTENANCE
section for more information.
NOTICE


Produktspezifikationen

Marke: Hatco
Kategorie: Heizung
Modell: FR-9

Brauchst du Hilfe?

Wenn Sie Hilfe mit Hatco FR-9 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Heizung Hatco

Bedienungsanleitung Heizung

Neueste Bedienungsanleitung für -Kategorien-