SBB232
2-pole, 32A Modular Switch with Indicator Light
Technical properties
Architecture
Type of order Break switch with light
Neutral position without neutral
Number of poles 2 P
Type of pole 2 P
Configuration
Number of modules 1
Main electrical features
Rated operational voltage Ue 230 V
Frequency 50/60
Voltage
Rated insulation voltage 440 V
Type of voltage input 1 AC
Rated impulse withstand voltage 4000 V
Electric current
Rated operational current in AC21category
B 32 A
Acceptable current rating with AC22
category A 32 A
Rated current 32 A
Rated short-time withstand current 1s 0.48 kA
Thermal rated current outside of housings 32 A
Rated operational current in AC21 category
A 32 A
Acceptable current rating with AC22
category B 32 A
Dimensions
Depth of installed product 68 mm
Height of installed product 83 mm
Width of installed product 17.5 mm
Frequency
Frequency 50 to 60 Hz
Power
Total power loss under IN 3.1 W
Power loss per pole at In 1.5 W
Subject to technical modifications
Endurance
Electrical durability at nominal load in
AC21in operating cycles 25000
Electrical durability at nominal load in AC22
in operating cycles 25000
Number of mechanical operations 200000
Lighting control
Light colour orange
Type of lamp LED
Installation, mounting
Tightening torque 1,8Nm
Connection
Connection cross-sect. flexible conductor 1,5 / 10mm²
Connection cross-sect. rigid cable 1,5 / 16mm²
Lamp socket type Sans
Cage clamp position off set
Type of connection with screw
Equipment
Quantity of NC contacts 0
Quantity of NO contacts 2
Quantity of INV contacts 0
Standards
Standard text IEC 60947-3,IEC/EN 60669-1
European directive WEEE concerned
Safety
Protection index IP IP20
Use conditions
Operating temperature -20…50 °C
Degree of pollution according to IEC 60664 /
IEC 60947-2 2
Altitude 2000 m
Storage/transport temperature -40…80 °C
Subject to technical modifications


Produktspezifikationen

Marke: Hager
Kategorie: Schalter
Modell: SBB232

Brauchst du Hilfe?

Wenn Sie Hilfe mit Hager SBB232 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Schalter Hager

Bedienungsanleitung Schalter

Neueste Bedienungsanleitung für -Kategorien-