Cooling
230 V
50 Hz/1Ø
5150 W
1840 W
25.0 A
8.40 A
R32
0.64 kg
800 CMH
10.00 kg
27.00 kg
10.00 kg
27.00 kg
GIC 18WTC3-WSB
Cooling
230 V
50 Hz/1Ø
5150 W
1840 W
25.0 A
8.40 A
R32
0.64 kg
800 CMH
GIC 18YTC3-WTA
Cooling
230 V
50 Hz/1Ø
3550 W
1290 W
20.0 A
5.90 A
R32
0.45 kg
450 CMH
8.00 kg
22.60 kg
GIC 12WTC3-WTA
Cooling
230 V
50 Hz/1Ø
3550 W
1290 W
20.0 A
5.90 A
R32
0.45 kg
450 CMH
8.00 kg
22.60 kg
GIC 12YTC3-WTA
Cooling
230 V
50 Hz/1Ø
3500 W
930 W
20.0 A
4.50 A
R32
0.63 kg
760 CMH
10.00 kg
24.50 kg
GIC 12WTC5-WTA
Cooling
230 V
50 Hz/1Ø
3500 W
930 W
20.0 A
4.50 A
R32
0.63 kg
760 CMH
10.00 kg
24.50 kg
GIC 12YTC5-WTA
IDU
ODU
COMP LRA
PERFORMANCE PARAMETERS
12
17
18
31
32
METHODOLOGY FOR FREQUENCY SETTING
33
NAMES OF PARTS
No. Description
1
2
Front panel
Air lter
Optional lter (if installed)
3
Terminal block cover
4
Emergency button
5
6
LED Display
Signal receiver
7
Airow direction louver
8Deectors
9
Remote controller
10
Note: the above gures are only intended to be a
simple diagram of the appliance and may not
correspond to the appearance of the units that
have been purchased.
No. Description
13 Air outlet grill
Terminal block cover
14
Gas valve
15
Liquid valve
16
11
Indoor unit rating label ( )Stick position optional
17
Outdoor unit rating label
12
Ionizer (if installed) generator
13
15
16
17
INDOOR UNIT
OUTDOOR UNIT
1 2-3
6
4-5
9
11 8
10 7
14
DIS
PLAY
HE
ALTH
Y
3D
ON/O F F
SWING
FA
N
TIME
R
SUPE
R
SLEE
PMODE
ECO
CLOC
K
12
INDOOR UNIT
OUTDOOR UNIT
10
INDOOR UNIT DISPLAY
1
2
5
3
4
1 2 3 4 5
The shape and position of switches and indicators may be dierent according to the model, but their
function is the same.
12 4 5
3
1
2
3
4
5
31 2
3
54
No.
Led Function
POWER This symbol appears when the unit is power on
1
2
3
4
5
Temperature display (if present)
/Error code
(1) Lights up during Timer operation when
the air conditioner is operational
(2)Displays the malfunction code when fault
occurs.
SLEEP mode
Lights up during Timer operation.
The symbol appears when the unit is turned
on, and disappear when the unit is turned o.
SLEEP
TIMER
RUN
3
4
2
1 2 4 5
16
REMOTE CONTROLLER
The shape and position of buttons and indicators maybe dierence according to the model, but their
function is the same.
The out looking and some function of remote controller maybe dierence.
The unit conrms the correct reception of each press button with a beep.
To select the mode of operation
To LED displayswitch on/o the
To activate or deactivate of the movement of the deectors.
To activate the function SLEEP
To switch - on /o HEALTHY funtion.It is a button which controls the ionizer or
plasma genera for available model only.
In cooling mode,press this button ,the temperature will increase 2 on the base of
setting temperature
In heating mode, press this button, the temperature will decrease 2 on the base of
setting temperature
Press this button to activate / deactivate the Super function which enables the unit to reach
the preset temperature in the shortest time.
In COOL mode, the unit will give the maximum cooling temperature with 16 ,high fan
speed.
In HEAT ode, the unit will give the maximum heating temperature with 31 ,high fan
speed.
Press it to decrease temperature/ time setting.
Press it to increase temperature / time setting.
Press it to start or stop operation.
Press it to set auto-off timer.
To select the fan speed of auto/low/mid/high
No.
8
10
12
6
14
7
9
13
MODE
SWING
DISPLAY
SLEEP
HEALTHY
ECO
SUPER or TURBO
11
3D
CLOCK
1
(TEMP DN)
(TEMP UP)
2
3
4
ON/OFF
FAN
5TIMER
When you press "3D", the horizontal and vertical vanes will swing together at the
same time.
RESET
ANTI-MILDEW
Button Function
To activate the function ANTI-MILDEW
To restart REMOTE CONTROLLER
16
15
When you press this button,the time will be flickering;then through" "and
" ",you can adjust the time(one time you press,one minute you adjust;and if
you continue to press,the time change rapidly ), after adjusting to your required
time, please press this button again to fix the time.
Mute To activate the function of Mute
or or
REMOTE CONTROLLER
ON/OFF
SWINGFAN
TIMER SUPER
SLEE MODEP
ECO
111
3
2
9
13
8
12
4
14
10
5
6
DISPLAY HEALTHY3D
CLOCK
7
1
3
4
5
12
13
10
9
8
7
6
ON O FF ON
C
AUT OQUIET
POWERFUL
hr
DELAY
DRY
FAN
HEAT
TIMER
HEALTHY
AIR
SWING
FAN
SPEED
2
COOL
FEEL
ON/OFF
MODE TIMER
FAN SPEED SUPER ECO
ANTI-MILDEW
SWING SLEEP HEALTHY
DISPLAY RESET
15
16
SLEEP
TIMER SWING
MODE
ON/OFF
2
1
6
5
8
FAN
3
10
4
Auto
Feel Cool
Low
Dry Heat
Mid
High
Sleep
Swing
Timer
OFF
Timer
Fan
C
h
ON
MODE
FAN SLEEP
ECO TIMER
SWING
TURBOHEALTHY
DISPLAY
SWING
6
8
1
2
3
5
12
13
10
10
4
7
9
6
5
8
2
1
3
4
MID
AU T O
SWING X
HIGH
LOW
DRY
FAN
HEAT
CO OL
FEEL
SLEEP
SWING YSUPER
TIME R ON TIME R OFF
ON/O FF
FAN SWING X SWING Y
SUPER SLEEP
MODE
TIMER
10
Mode
Fan
Eco
Temp Swing
Timer
DisplaySleep
Mute Turbo Health
8
3
6
7
9
13
10
5
16
4
1
2
12
The shape and position of buttons and indicators maybe difference according to the model, but their
function is the same.
The out looking and some function of remote controller maybe difference.
Mildew
or
REMOTE CONTROLLER
Remote controller DISPLAY
Meaning of symbols on the liquid crystal display
1
2
3
4
5
6
7
8
9
10
11
12
13
14
FEEL mode indicator
COOLING indicator
DEHUMIDIFYING indicator
FAN ONLY OPERATION indicator
HEATING indicator
SIGNAL RECEPTION indicator
TIMER OFF indicator
TIMER ON indicator
AUTO FAN indicator
LOW FAN SPEED indicator
or MIDDLE FAN SPEED indicator
or
or
HIGH FAN SPEED indicator
QUIET or
or SLEEP indicator
or
AUTO or
or FLAP SWING indicator
15
SUPER indicator
16
17
HEALTHY indicator
TIMER
ON
or
or
TIMER
OFF
or
HEALTHY
ON
18
ECO indicator
19
ANTI-MILDEW indicator
or
POWERFUL
or
or ECO
or
BATTERY indicator
or
or
or
or
or
or
or
or
or
20
21
22
COMFORTABLE SLEEP indicator (optional)
FEEL indicator(optional)
Meaning
No. Symbols
(FLASH)
FLAP and Deflectors SWING indicator
CLOCK indicator
23
or
or
TURBO
or
24 Mute indicator
or
or
or
or
or
or
or
or
or
or
(FLASH)
or
or
10
11
12
13
(Applicable for hot & cold model only)
14
15
16
17
If a user has set the AC temperature between 16°C and 23°C using the remote, prior
to switching the AC OFF; then when the AC is turned ON, it will start operating at
24°C.Also, the remote here will display 24°C.
But, if a user has set the AC temperature above 24°C using the remote, prior to switch-
ing the AC OFF; then when the AC is turned ON, it will start operating at the set
temperature.
18
19
20
21
22
23
24
25
INSTALLATION MANUAL---Installation of the outdoor unit
outdoor unit
screw
wiring diagram on the
back of the cover
Screw the are nuts to the outdoor unit coupling with
the same tightening procedures described for the indoor
unit.
connection pipes
are nuts
liquid tap
gas tap
indoor unit
protection caps
liquid valve
gas valve
service port nut
To avoid leakage, pay attention to the following points:
1. Tighten the are nuts using two wrenches. Pay atten-
tion not to damage the pipes.
2. If the tightening torque is not sucient , there will
probably be some leakage. With excessive tightening
torque there will also be some leakage, as the ange
could be damaged.
3. The surest system consists in tightening the connecti-
on by using a x wrench and a torque wrench:in this
case use the table on page 29.
vacuum pump
service port
Air and humidity left inside the refrigerant circuit can
cause compressor malfunction. After having connected
the indoor and outdoor units, bleed the air and humidity
from the refrigerant circuit by using a vacuum pump.
ELECTRICAL CONNECTIONS
CONNECTING THE PIPES
BLEEDING
tap
1. Remove the handle on the right side plate of outdoor unit.
2. Connect the power connection cord to the terminal board.
Wiring should t that of indoor unit.
3. Fix the power connection cord with wire clamp.
4. Conrm if the wire has been xed properly.
5. An ecient earth connection must be ensured.
6. Recover the handle.
remove
the right
side plate
26
29
METHODOLOGY FOR FREQUENCY SETTING
Full load and half load capacity modes are applicable only for testing purpose in
authorized test laboratories.
Before setting the mode, lab conditions to be stabilized as per IS1391 Part 2.
Test Mode Activate:
Running the AC, in cooling modeset temperature at 30 degree,middle fan speed.
Press 7 times sleep button with 8 seconds,
After 3 times Beep sound & test mode will activate.
Then Remo se empera ure te t t t : 25°C to test full capacity .
After nish full capacity test, no stop the AC, directly make Remote set
temperature: 26°C to test half capacity .
32
ERROR SIGNALS ON DISPLAY
In case of error, the display on the indoor unit show the following error codes.
34
BRANCH ADDRESSES / SERVICE CONNECT
Branch Branch Addresses
Toll-Free : 1800-209-5511
Website: www.godrejappliances.com & www.godrejsmartcare.com
E-mail: smartcare@godrej.com


Produktspezifikationen

Marke: Godrej
Kategorie: Klimaanlage
Modell: GIC 12WTC3- WTA

Brauchst du Hilfe?

Wenn Sie Hilfe mit Godrej GIC 12WTC3- WTA benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Klimaanlage Godrej

Bedienungsanleitung Klimaanlage

Neueste Bedienungsanleitung fĂŒr -Kategorien-