Motherboard Components/ 主板组件
No. Code Descripon
1 CPU Intel Xeon® processor D-1541, FCBGA1667 SoC (MB10-DS3)
2 SFP+1_2 SFP+ connectors #1/#2
3 LAN1_2 LAN ports
4 USB3_MLAN BMC Management LAN port (top) / USB 3.0 ports (boom)
5 CPU0_FAN CPU fan connector
6 VGA VGA port
7 SW_ID ID switch buon w/LED
8 SW_PWR Power buon w/LED
9 LED_STA System Status LED
10 P12V_AUX1 8 pin power connector
11 FP_1 Front panel header
12 ATX1 24 pin main power connector
13 DIMM_P0_A0 Channel 1 slot 0
14 DIMM_P0_A1 Channel 2 slot 1
15 DIMM_P0_B0 Channel 3 slot 0
16 DIMM_P0_B1 Channel 4 slot 1
17 BAT1 Baery
18 PMBUS PMBus connector
19 SATA_DOM0 SATA DOM power cable connector
20 SATA0 SATA 3 6Gb/s connector
21 SATA1 SATA 3 6Gb/s connector
22 SATA_2_3 SATA 3 6Gb/s connectors
23 SATA_4_5 SATA 3 6Gb/s connectors
24 SATA_SGPIO SATA SGPIO header
25 COM1 Serial port cable connector
26 LED_BMC1 BMC firmware readiness LED
27 BP_1 HDD back plane board header
28 NVME_PH NVME connector
29 TPM TPM module connector
30 IPMB IPMB connector
No. Code Descripon
31 CLR_CMOS Clear CMOS jumper
1-2 Close: Normal operaon (Default seng)
2-3 Close: Clear CMOS data.
32 PCIE_1 PCI Express p1-x16 slot
33 ME_UPDATE ME update jumper
1-2 Close: Normal operaon (Default seng)
2-3 Close: ME update mode.
34 ME_RCVR ME recovry jumper
1-2 Close: Normal operaon. (Default seng)
2-3 Close: ME recovery mode.
35 S3_MASK S3 Power On Select jumper
1-2 Close: Stop an inial power on when BMC is not ready.
2-3 Close: Keep inial power on. (Default seng)
1
32 4 5 6 7 8 9
12
10
11
13141516
19 18
17
2021222325
24
262728
30
29
31
32
33
34
35
System Components/ 系统组件
No Descripon
1 HDD bays
2 System fan #9/#10 (FAN9/FAN10)
3 System fan #7/#8 (FAN7/FAN8)
4 System fan #5/#6 (FAN5/FAN6)
5 System fan #3/#4 (FAN3/FAN4)
6 System fan #1/#2 (FAN1/FAN2)
7 CPU and CPU heat sink
8 Memory slots
9 PCIe riser bracket
10 Power supply cage
CAUTION!
To connect system fan connector, follow the instrucon:
Blue/Red cable connect to odd numbered connector.
White/Amber cable connect to even numbered connector.
注意!
蓝/红电缆连连接于单数风扇插座。
白/橘电缆连连接于双数风扇插座。
Front Panel Header/ 前面板接头
No. Pin Define
1 Power LED+
3 No Pin
5 Power LED-
7 HDD LED+
9 HDD LED-
11 Power Buon
13 GND
15 Reset Buon+
17 GND
19 ID Switch+
21 ID Switch-
23 NMI Switch-
No. Pin Define
2 5V Standby
4 ID LED+
6 ID LED-
8 System Front Board LED+
10 System Status LED-
12 LAN1 Acve LED+
14 LAN1 Link LED-
16 SMBus Data
18 SMBus Clock
20 Case Open
22 LAN2 Acve LED
24 LAN2 Link LED-
1
2423
2
HDD Back Plane Board Header/ 硬盘驱动器底板接头
1 2
25 26
No. Pin Define
1 BP_SGP_CLK
3 BP_SGP_GLD
5 BP_SGP_DOUT
7 Key Pin
9 GND
11 BP_LED_G_N
13 BP_SGP_DIN
15 GND
17 GND
19 P_3V3_AUX
21 P_3V3_AUX
23 GND
25 BP_PRESENSE
No. Pin Define
2 No Connect
4 FAN_SGP_Gate
6 GND
8 Reset
10 BP_LED_A_N
12 GND
14 No Connect
16 SMB_BP_DATA
18 SMB_BP_CLK
20 BMC_ACK
22 BMC_REQ
24 Key Pin
26 GND
CAUTION!
Before you remove or install the system
cover:
Make sure the system is not turned on
or connected to AC power.
注意!
在卸下或安装系统机盖之前,请注意
下列事项:
确保系统未开启且未连接到交流电源。
System Cover/ 机箱盖
1
1
1
2
3
4
Fan Duct/ 风扇散热片
1
2
Memory Populaon Configuraon/ 安装内存
Type
Ranks PerDIMM
and
Data Width
1600, 1866, 2133, 2400*
1600, 1866, 2133, 2400*
1600, 1866, 2133, 2400*
1600, 1866, 2133, 2400*
1600, 1866, 2133, 2400*
1600, 1866, 2133, 2400*
1600, 1866, 2133, 2400*
1600, 1866, 2133, 2400*
1600, 1866, 2133, 2400*
1600, 1866, 2133, 2400*
1600, 1866, 2133, 2400*
1600, 1866, 2133, 2400*
Speed (MT/s);
Slot Per Channel (SPC) and DIMM Per Channel (DPC)
1 Slot Per Channel
1DPC
2 Slot Per Channel
1DPC 2DPC
RDIMM
RDIMM
RDIMM
RDIMM
SRx4 ECC
SRx8 ECC
DRx8 ECC
DRx4 ECC
仅Intel Xeon D-1541处理器支持DDR4-MHz内存。®
只使用一个DIMM时,必须安装到内存插槽0。
若安装顺序有误,系统将不能正常引导。
Note: DDR4 2400MHz is only available on Intel Xeon® D-1541 processor.
When only one DIMM is used, it must be populated in memory slot0 first.
System will not boot normally with incorrect populated sequence.
System Fan/ 系统风扇
CAUTION!
Before you remove or install the system fan:
Make sure the system is not turned on or
connected to the AC power.
Disconnect all necessary cable connecons.
Failure to observe these
warnings could result in personal injury or
damage to the equipment.
注意!
确保系统未开机且未连接到交流电源。
断开所有必要的线缆连接。若不遵循这些
警告,可能造成人员伤害或设备损坏。
1
2
CAUTION!
Read the following guidelines before you begin to install the Hard disk drive:
Take note of the drive tray orientaon before sliding it out.
The tray will not fit back into the bay if inserted incorrectly.
Make sure that the HDD is connected to the HDD connector on the backplane.
注意!
在滑出驱动器托盘之前,注意其方向。
托盘插入不当时,无法进入托槽。
确保硬盘驱动器连接到底板上的硬盘驱动
器底板。
No Descripon
1 HDD#3
2 HDD#2
3 HDD#1
4 HDD#0
5 SGPIO header
6 Fan connector#13
7 Fan connector#14
8 Fan connector#11
9 Fan connector#12
10 ODD power connector
11 Fan connector#9
HDD Backplane Board Components
No Descripon
12 Fan connector#10
13 Fan connector#7
14 Fan connector#8
15 Fan connector#5
16 Fan connector#6
17 Fan connector#3
18 Fan connector#4
19 Fan connector#1
20 Fan connector#2
21 Fan connector#15
22 Fan connector#16
Hard Disk Drive and Back Plane Board/ 硬盘驱动器与硬盘驱动器底板
5
1234
6 7 8 9
10
11 12 13 14 15 16 17 18 19 20 21 22
3
44
1
2
System Front View System Rear View
No Descripon
1 ID buon w/LED
2 Power buon w/LED
3 HDD bays
No Descripon
1 Power supply fan
2 Power supply module cord socket
3 System Status LED
4 Power buon w/LED
5 ID switch buon w/LED
6 VGA port
7 USB 3.0 ports
8 10/100/1000 Server management LAN port
9 GbE LAN ports
10 SFP+ LAN ports
Front & Rear/ 系统前部与后部概览
Off
State Description
Yellow On 1Gbps data rate
Green On 100Mbps data rate
10Mbps data rate
State Description
Yellow On 1Gbps data rate
Green On 10 Gbps data rate
Speed LED Link/Acvity
LED
Speed LED Link/Acvity
LED
SFP+ LAN LED:
ID buon/LED:Power buon/LED:
Blue On System identifcation is active.
Off System identifcation is disabled.
State Description
Green On
Off
Description
System is powered on
System is powered off
State
1 2
3
1 2 3
45 6 7 8 9 10
PCI Express Card/PCI Express 扩展卡
注意!
在安装扩展卡前,请注意下列事项:
确保系统未开启且未连接到交流电源。
CAUTION!
Before you remove or install the PCI express card:
Make sure the system is not turned on or connected to AC power.
1
2
3
4
5
6
7
8
注意!
在替换或安装电源前,请注意下列事项:
确保系统未开启且未连接到交流电源
。
CAUTION!
Before you remove or install the power
supplies:
Make sure the system is not turned on or
connected to AC power.
Power Supply/ 电源
1
2
3
Rail Kit/ 导轨
Release
Lock out
⯮ⅎ庳⎽⇡
Release and de ch the inner member from the slideta
1
M4X6
Click
Aach the unit to the inner member
⯭Ⅼ彏擨
ᷱ
㜡⏗
2
Release
lock in
Insert the unit to complete the in nstallao
墬⅌㜡㞝
4
Brac tke
M6X13
M6-NUT
Fix the outer member/bracket assembly to the frame
⯭⣽彏㈿㞝擨⅌㜡㞝
3
Front Panel LED and Buons/ 前面板 LED 说明
7复位按钮 按此按钮启动系统。
8复位按钮 按此按钮启动不可遮罩中断功能。
2按下按钮启动系统识别功能。ID按钮
1系统处于开机状态。
系统处于ACPI S1状态(睡眠模式)。
系统未开机或处于ACPIS5状态(关机状态)。
系统处于ACPI S4状态(休眠模式)。
电源按钮和LED 绿色
绿色
恒亮
不亮
闪烁
无亮灯
不亮 断开连接/待机无亮灯
5/6 恒亮
闪烁
系统和网络之间的链接
网络访问
绿色
绿色
LAN1/LAN2活动LED
6硬盘驱动器定位
硬盘驱动器访问
硬盘驱动器访问
硬盘故障
无硬盘驱动器访问
绿色
橙色
绿色/橙色
不亮
亮
亮
闪烁
无亮灯
硬盘驱动器LED
闪烁
编号 名称 颜色 状态 说明
3系统正常运行。
橙色
绿色
系统状态LED 恒亮
恒亮
不亮
不亮
闪烁
无亮灯
效能降低情形,可能为下列状况:
处理器问题
内存问题
严重情形,可能为下列状况:
电源模块故障
系统风扇故障
电源电压问题
系统温度/电压问题
非严重情形,可能为下列状况:
冗余电源模块故障
系统温度/电压问题
机箱侵入
系统未正常运行,可能为下列状况:
POST错误
NMI错误
处理器或终结器缺失
No. Name Color Status Description
7Reset Button Press the button to reset the system.
8NMI Button Press the button to generate an NMI.
2 Press the button to activate system identifcation.ID Button
1 System is powered on.
System is in ACPI S1 state (sleep mode).
System is not powered on or in ACPI S5 state (power off).
System is in ACPI S4 state (hibernate mode).
Power Button and LED Green
Green
Solid On
Off
Blink
N/A
4HDD locate
HDD access
HDD access
HDD fault
No HDD access or no HDD fault.
Green
Amber
Green/Amber
On
Off
Blink
On
Blink
N/A
HDD Status LED
5/6 Link between system and network or no access.
Data transmission or receiving is occurring.
No data transmission or receiving is occurring.
Solid On
Off
Blink
Green
Green
N/A
LAN1/2 Active/Link LEDs
状态
3 System is operating normally.
Degrade condition, may indicates:
CPU failure
DIMM killed
System Status LED
Green
Amber
Solid On
Critical condition, may indicates:
Power module failure
System fan failure
Power supply voltage issue
System temperature
Solid On
Non-critical condition, may indicates:
Redundant power module failure
Temperature and voltage issue
Chassis intrusion
System is not ready, may indicates:
POST error
NMI error
Processor or terminator missing
Blink
N/A N/A
Off
12345678
G150-B10 Quick Installaon Guide/G150-B10 快速安装说明
10/100/1000 LAN LED:
1
23456
7
9
8
10
PN:25ME0-G15000-CLS
Regulatory Noces
Connect With Us
WEEE Symbol Statement
For more informaon, visit our website at:
hp://b2b.gigabyte.com
You are a professional?
Get access to our complete source of sales & markeng materials at:
hp://reseller.b2b.gigabyte.com
hps://www.facebook.com/gigabyteserver
The symbol shown below is on the product or on its packaging, which indicates that this product must not be disposed of with other
waste. Instead, the device should be taken to the waste collecon centers for acvaon of the treatment, collecon, recycling and
disposal procedure. The separate collecon and recycling of your waste equipment at the me of disposal will help to conserve
natural resources and ensure that it is recycled in a manner that protects human health and the environment.
For more informaon about where you can drop off your waste equipment for recycling, please contact your local government
office, your household waste disposal service or where you purchased the product for details of environmentally safe recycling.
When your electrical or electronic equipment is no longer useful to you, "take it back" to your local or regional waste
collecon administraon for recycling.
If you need further assistance in recycling, reusing in your "end of life" product, you may contact us at the Customer Care
number listed in your product's user's manual and we will be glad to help you with your effort.
GIGABYTE产品未故意添加和使用有害物质(Cd、Pb、Hg、Cr+6、PBDE和PBB)。所有部件和元件均经过严格挑选,符合RoHS要求。此
外,我们GIGABYTE一直致力于开发不使用国际上禁止的有毒化学品的产品。
GIGABYTE products have not intended to add and safe from hazardous substances (Cd, Pb, Hg, Cr+6, PBDE and PBB). The parts and components
have been carefully selected to meet RoHS requirement. Moreover, we at GIGABYTE are connuing our efforts to develop products that do not use
internaonally banned toxic chemicals.
Restricon of Hazardous Substances (RoHS) Direcve Statement
This server is intended for installaon only in restricted access locaons where .
• Access can only be gained by SERVICE PERSONS who have been instructed about the reasons for the restricons applied to the
locaon and about any precauons that shall be taken.
• Access is through the use of a TOOL or lock and key, or other means of security, and is controlled by the authority responsible for the locaon.
The following or similar rack-mount instrucons are included with the installaon instrucons:
A) Elevated Operang Ambient - If installed in a closed or mul-unit rack assembly, the operang ambient temperature of the rack environment
may be greater than room ambient. Therefore, consideraon should be given to installing the equipment in an environment compable with the
maximum ambient temperature (Tma) specified by the manufacturer.
B) Reduced Air Flow - Installaon of the equipment in a rack should be such that the amount of air flow required for safe operaon of the
equipment is not compromised.
C) Mechanical Loading - Mounng of the equipment in the rack should be such that a hazardous condion is not achieved due to uneven mechani-
cal loading.
D) Circuit Overloading - Consideraon should be given to the connecon of the equipment to the supply circuit and the effect that overloading of
the circuits might have on overcurrent protecon and supply wiring. Appropriate consideraon of equipment nameplate rangs should be used
when addressing this concern.
E) Reliable Earthing - Reliable earthing of rack-mounted equipment should be maintained. Parcular aenon should be given to supply connec-
ons other than direct connecons to the branch circuit (e.g. use of power strips)."
Disconnect 2 power supply cords before servicing
This device complies with Part 15 of the FCC Rules.
Operaon is subject to the following two condions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received,
including interference that may cause undesired operaon.
FCC Statement
This equipment should not be operated above an ambient operaon temperature of 35 degrees cengrade.
Ambient Operaon
CAUTION: The power supplies in your system may produce high voltages and energyhazards, which can cause bodily harms. Unless you are
instructed otherwise, only trained service technicians are authorized to remove the covers and access any of the components inside the system.
Power Supply
CAUTION: Do not connect of disconnect any cables or perform installaon, maintenance, or reconfiguraon of this server during an electrical storm
CAUTION: Connect all power cords to a properly wired and grounded electrical outlet.
Reliable Earthing:
CAUTION: This server contains hazardous moving fan blades, keep fingers and other bodyparts away.
Disconnect all power supply cords before servicing. Connect power supply cord only aer all the covers are properly installed.
Hazardous FAN
CAUTION: This server contains hazardous energy over 240VA on the backplane. To prevent accidental short circuit, always insert the
HDD trays aer servicing.
Hazardous Energy
Restricted Access Locaon
The system may have more than one power supply cable. To reduce the risk of electrical shock, a trained service technician may need to disconnect
all power supply cables before servicing the system.
Rack Mount Instrucons
CAN ICES-3 (A)/NMB-3(A)
CAUTION: Slider/rail mounted equipment is not to be
used as a shelf or a work space.
CAUTION: Whenever you need to li the system, get others to assist you.
To avoid injury, do not aempt to li the system by yourself.
限制使用有害物质 (RoHS) 指令声明
California Proposion 65 Warning
WARNING:
This product contains a chemicals , including lead, known to the State of California to cause cancer and birth defects or other reproducve harm.
For more informaon, please visit: hp://www.p65warnings.ca.gov/
Baery Warning:
Incorrectly installing a baery or using incompable baery may increase the risk of ifre explosion. Replace the baery only with
the same or equivalent type.
Do not disassemble, crush, punchture baeries.
Do not store or place your baery pack next to or in a heat source such as a fire, heatgenerang appliance, can or exhaust
vent. Heang baery cells to temperatures above 65oC (149oF) can cause explosion or fire.
Do not aempt to open or service baeries. Do not dispose of baeries in a fire or with household waste.
电池警告:
电池安装不当或使用不兼容的电池会增加火灾爆炸风险。更换电池时,只可使用相同或同等类型的电池。
请勿拆解、挤压、刺破电池。
请勿将电池存放或放置在热源中或旁边,如火源、产生热的设备、罐体或排气口。电池温度升至65oC (149oF)以上
可能导致爆炸或火灾。
请勿尝试打开或维修电池。电池废弃时,请勿投入火中或者作为家庭废弃物进行处理。
依照中华人民共和国的有毒有害物质的限制要求(China RoHS)提供以下的表格:
中华人民共和国电子信息产品中有毒有害物质或元素的名称及含量标识格式
声明 本系统功率大于 1300W
Produktspezifikationen
Marke: | Gigabyte |
Kategorie: | Server |
Modell: | G150-B10 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Gigabyte G150-B10 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Server Gigabyte
11 Oktober 2024
6 Oktober 2024
1 September 2024
1 September 2024
1 September 2024
31 August 2024
31 August 2024
31 August 2024
31 August 2024
31 August 2024
Bedienungsanleitung Server
- Server Acer
- Server Asus
- Server HP
- Server Medion
- Server Sony
- Server ZyXEL
- Server Buffalo
- Server Allnet
- Server Linksys
- Server Netgear
- Server Fantec
- Server Technics
- Server Abus
- Server Megasat
- Server Toshiba
- Server Lindy
- Server Dell
- Server Lenovo
- Server Tripp Lite
- Server TRENDnet
- Server Western Digital
- Server AVerMedia
- Server Veritas
- Server Black Box
- Server Supermicro
- Server SilverStone
- Server NEC
- Server Monacor
- Server Seagate
- Server Fujitsu
- Server Maxdata
- Server Revox
- Server Totolink
- Server Conceptronic
- Server D-Link
- Server QNAP
- Server Digitus
- Server LevelOne
- Server APC
- Server Cisco
- Server Freecom
- Server Synology
- Server Kramer
- Server Intellinet
- Server Eaton
- Server Hikvision
- Server FLIR
- Server ELAC
- Server Planet
- Server Asustor
- Server Blackmagic Design
- Server Dane Elec
- Server Digi
- Server Dual Bay
- Server EMC
- Server GeoVision
- Server Ibm
- Server In Win
- Server Iomega
- Server LaCie
- Server Provision ISR
- Server Quantum
- Server Sun
- Server AMX
- Server ACTi
- Server Vimar
- Server Siig
- Server Intel
- Server Moxa
- Server StarTech.com
- Server Smart-AVI
- Server Mobotix
- Server Sonnet
- Server SEH
- Server Gefen
- Server Avocent
- Server Atlantis Land
- Server Hanwha
- Server ATen
- Server KanexPro
- Server Axis
- Server Advantech
- Server HGST
- Server Kiloview
- Server B&B Electronics
- Server Extron
- Server Atlona
- Server Rocstor
- Server Raidsonic
- Server G-Technology
- Server Infortrend
- Server Areca
- Server Silex
- Server Promise Technology
- Server Matrox
- Server Origin Storage
- Server Ernitec
- Server EXSYS
- Server Raritan
- Server C2G
- Server Chenbro Micom
- Server Lantronix
- Server IStarUSA
- Server Valcom
- Server TAIDEN
- Server MvixUSA
- Server Opengear
- Server Mr. Signal
- Server NETSCOUT
Neueste Bedienungsanleitung für -Kategorien-
13 Oktober 2024
12 Oktober 2024
12 Oktober 2024
11 Oktober 2024
10 Oktober 2024
4 Oktober 2024
3 Oktober 2024
3 Oktober 2024
3 Oktober 2024
3 Oktober 2024