Genelec 1032 CPM Bedienungsanleitung


Lesen Sie kostenlos die đź“– deutsche Bedienungsanleitung fĂĽr Genelec 1032 CPM (8 Seiten) in der Kategorie Lautsprecher. Dieser Bedienungsanleitung war fĂĽr 9 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/8
1032C
Smart Active Monitor
Operating Manual
2
Introduction
Congratulations and a thank you for the purchase of this
Genelec Smart Active Monitor™ (SAM™) system. This manual
addresses the stand-alone setup and use of the 1032C SAM
monitor. This monitors can also be set up and used with the
Genelec Loudspeaker Manager GLM™ and the proprietary
Genelec monitor control network and software, offering much
more versatile acoustic settings and features. Use with the
GLM™ is described in the GLM™ System Operating Manual.
All Genelec SAM systems are designed to integrate easily
into all professional environments, supporting both standard
analog line level audio and AES/EBU formatted digital audio
signals.
The 1032C is suitable for professional monitoring tasks
demanding high precision and reliability of monitoring.
The Directivity Control Waveguide™ (DCW™) technology
provides excellent frequency balance even in difficult acoustic
environments.
Each monitor is supplied with a mains cable, one 5 m GLM
network cable and an operating manual.
Energy saving Intelligent Signal Sensing (ISS™) can be turned
on to put the monitor automatically into a deep sleep state
where the product consumes less than one Watt of power. Upon
sensing an input signal the monitor automatically wakes up to
full operation. The wait until entering the ISS power save can be
configured using the GLM software. When the ISS is active you
can have your monitoring system ready for action at all times.
System setup using GLM™ Control
Network
Although the 1032C can be used without the GLM™ software
and control network, they only reach their full potential when
set up and calibrated using the GLM™ software. Genelec
Loudspeaker Manager GLM™ and the proprietary Genelec
monitor control network and software offer automated acoustic
equalization and alignment for any reproduction system from
simple stereo to very complex 3D immersive audio setups
including also one or more subwoofers. GLM setup is fast and
accurate. The settings can be controlled with a computer or be
permanently stored in the monitors to make the setup available
at all times even when a computer is not in use. Genelec
recommends setting up SAM monitoring systems using GLM.
You can find a detailed description of the setup and the use of
GLM™ in the GLM™ System Operating Manual.
The setup is fast and consists of the following steps:
•  Connect a CAT5 (RJ45) cable between each monitor (and
subwoofer) and finally to the control network input of the
GLM Adapter device (see Figure 1).
•  Connect the GLM Adapter device to computer USB
connector.
•  Using a microphone stand, place the Genelec measurement
microphone at the listening location with the microphone
pointing upwards and the microphone top at the height of the
engineer’s ear. The microphone is a part of the GLM User Kit.
•  Connect the microphone cable to the microphone input in
the GLM Adapter device.
•  Download the GLM software at the Genelec web site (www.
genelec.com).
•  Install the GLM software and follow the instructions in the
software to measure and set up your monitors.
•  If you plan to not use a computer for controlling the
monitors, use the GLM software to write the setting into the
monitors (use menu item “Store | Store the Current Group
Settings…”).
While the GLM network is disconnected the settings stored
using the Genelec Loudspeaker Manager software can be
selected in use by setting the STORED switch ON.
Setup without using the GLM
When GLM is not available, you can use the settings on the
monitor for system setup. These settings are limited but provide
the basic acoustical calibrations and input selection. To use this
method, set the STORED switch OFF.
3
Connect the MAINS INPUT to the mains supply. These
products support any mains voltage globally (100-240 VAC,
50-60 Hz) so they can be plugged in anywhere. If the mains
power is provided with a generator, inverter or certain lower-
quality UPS devices, we recommend filtering of the mains
power voltage harmonics and taking care that the voltage
supply is stable.
The ANALOG IN connector is used for analog audio signals. The
maximum input level is +25 dBu. The 1032C produces 100 dB
SPL sound level at 1 meter in free space for an analogue input
signal of -6 dBu.
The DIGITAL IN AES/EBU female XLR connector is for AES/
EBU formatted digital audio input signals. This input is selected
automatically when a valid digital audio signal is present. Analog
input is selected when the AES/EBU signal input is disconnected.
The AES/EBU input supports two channels in a single cable).
When the digital source device controls the digital output level, it
may be advantageous to lower the level on the monitor’s controls,
which will enable the use of a higher digital signal level with more
digital resolution. With digital inputs the audio is referenced to
0 dBFS (dB relative to the digital full scale, the largest level that
can be represented in the AES/EBU signal). The 1032C produces
100 dB SPL sound level at 1 meter in free space for a digital
input signal of –30 dBFS. The DIGITAL OUT male XLR carries an
unaltered copy of the digital signal fed into the digital in connector.
This enables daisy-chaining up to four monitors.
Figure 2. Connectors and controls on the back panel of a
1032C.
SMART ACTIVE MONI RTO
ANALOG
IN
DIGI HRUTA T
AES/EBU
DIGI NTAL I
AES/EBU
GLM
NETWORK
MAINS I NPU T
50 / 60 Hz 2 00W
100 - 24 0 V~
WARNI NG: ELECTRIC S HOCK HAZ ARD.DONO PEN.DONOT S U JECTT O TO
WATEROR MOIST URE. NOUSER S ERVICEABL ARTS I NSI DE. REFEREP
SERVICI NG QUALIFI ED PERS ONNEL. US E EARTHED MAIN ONNECTIONTO S C
ONLY.
A SVERTIS S EMENT RI S QUE DE CHO LECTRIQUE.NE UVRIR.NEC É PAS O PA
EXPOSER À L'EAUOU AUCUNCOMPOSANT 'I NTÉRI EURL'HUMI DI TÉ. À L
REMPLAÇABLEPAR EUR.ADRESSER UTERÉPARATIONL'UTI LIS AT TO À UN
PERSONNELQUALI FI É. CET APPAREI OIT ÊTRERACCORDL D ÉÀ LAT ERRE.
LAIT E ONLII T ETTĂ„VĂ„ SUOJAKOSKETTI MILLA ARUS TETTUUNPI S TORASI AANV .
APPAR ET MĂ…TI LKOPLE ORDETSTI KKONTAKTAT S J .
APPAR ENSK AL NSLUAT LA TAS TI LL J ORDAT UTT AG.
Thi evics d e complie ith 15 anadia radi r equencys w FCCP art and C nICES- 003 of
Class missionrequirements.B e Refert o operatin anualfog m r f l iulnformation.
292-1332T-6
MADE IN FI NLAND
1032C
MAGNETI CALLYSHIE LDED
SERI AL NU MBER
ww genelec.comw.
RESET ACT ORTO F Y
SETTI NGS: PUSH
BUTTONFOR10S EC
SENSIT I VIT Y
IN dBuFOR
100 dB SPL m)(1
-2
+4
+2
-4 -6
+6
dBu
0
20 160
+2
-2
-4
dB
-6
0
4k 20k
BASS
TI LT
800
BASS
ROLL-OFF
DESKTOP
AL FFL O
TREBLE
TI LT
Frequency ( Hz )
(dB)(dB)
ON
OFF
BAS S LL-ORO FF
B LTAS S TI -2
-2
TREBL ETILT + 2
DES KTO HzP1 60 -4
LEDDI ESA BL
A
-20 dB
B
S T ORED
-10 dBLEVEL
DIGITAL
IS S
-4
-4
-4
CONNECTOR
PANEL
POWER
SWITCH
SENSITIVITY
ADJUSTMENT
TONE
CONTROLS
MICROPHONE
PLACED IN
THE LISTENING
POSITION
292-0063
GLM TERMINA RTO
COMPUTER
RUNNING
GLM SOFTWARE
USB CABLE
GLM ADAPTER
GLM NETWORK
CABLE
MONITORS
SUBWOOFER
Figure 1. GLM control network cabling
Figure 3. Connector panel detail.


Produktspezifikationen

Marke: Genelec
Kategorie: Lautsprecher
Modell: 1032 CPM

Brauchst du Hilfe?

Wenn Sie Hilfe mit Genelec 1032 CPM benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Lautsprecher Genelec

Bedienungsanleitung Lautsprecher

Neueste Bedienungsanleitung fĂĽr -Kategorien-