๎˜ฅ๎˜จ๎˜ฉ๎˜ฒ๎˜ต๎˜จ๎˜ƒ๎˜ผ๎˜ฒ๎˜ธ๎˜ƒ๎˜ฅ๎˜จ๎˜ช๎˜ฌ๎˜ฑ
Read these instructions completely
and carefully.
โ€ข ๎˜ฌ๎˜ฐ๎˜ณ๎˜ฒ๎˜ต๎˜ท๎˜ค๎˜ฑ๎˜ท๎˜ƒ๎šณ Save these instructions
for local inspectorโ€™s use.
โ€ข ๎˜ฌ๎˜ฐ๎˜ณ๎˜ฒ๎˜ต๎˜ท๎˜ค๎˜ฑ๎˜ท๎˜ƒ๎šณ Observe all governing
codes and ordinances.
โ€ข Note to Installer โ€“ Be sure to leave these
instructions with the Consumer.
โ€ข Note to Consumer โ€“ Keep these instructions for
future reference.
โ€ข Product failure due to improper installation is not
covered under the Warranty.
๎˜บ๎˜ค๎˜ต๎˜ฑ๎˜ฌ๎˜ฑ๎˜ช๎˜ƒ๎šณ๎˜ƒThis appliance must be
properly grounded.
โ€ข ๎˜ƒ
๎˜ฌ๎˜ฐ๎˜ณ๎˜ฒ๎˜ต๎˜ท๎˜ค๎˜ฑ๎˜ท๎˜ƒ๎šณ๎˜ƒLeak testing of the
appliance shall be conducted according to the
manufacturerโ€™s instructions.
โ€ข Proper installation is the responsibility of the
installer and product failure due to improper
installation is NOT covered under warranty.
๎˜ฌ๎˜ฑ๎˜ƒ๎˜ท๎˜ซ๎˜จ๎˜ƒ๎˜ฆ๎˜ฒ๎˜ฐ๎˜ฐ๎˜ฒ๎˜ฑ๎˜บ๎˜จ๎˜ค๎˜ฏ๎˜ท๎˜ซ๎˜ƒ๎˜ฒ๎˜ฉ๎˜ƒ
๎˜ฐ๎˜ค๎˜ถ๎˜ถ๎˜ค๎˜ฆ๎˜ซ๎˜ธ๎˜ถ๎˜จ๎˜ท๎˜ท๎˜ถ๎˜
โ€ข This product must be installed by a licensed
plumber or gas fitter.
โ€ข When using ball-type gas shut-off valves, they
shall be the T-handle type.
โ€ข A flexible gas connector, when used, must not
exceed 3 feet.
Questions? Call 800.GE.CARES (800.432.2737) or Visit our Website at: ge.com
In Canada, call 1.800.561.3344 or Visit our Website at: www.geappliances.ca
๎˜ฌ๎™‘๎™–๎™—๎™„๎™๎™๎™„๎™—๎™Œ๎™’๎™‘๎˜ƒ
๎˜–๎˜“โ€ณ๎˜ƒ๎˜ถ๎™ˆ๎™„๎™๎™ˆ๎™‡๎˜ƒ๎˜ช๎™„๎™–๎˜ƒ๎˜ฆ๎™’๎™’๎™Ž๎™—๎™’๎™“
๎˜ฌ๎™‘๎™–๎™—๎™•๎™˜๎™†๎™—๎™Œ๎™’๎™‘๎™– JGP328, JGP330, JGP933,
JGP940, JGP945
๎˜ฉ๎˜ฒ๎˜ต๎˜ƒ๎˜ผ๎˜ฒ๎˜ธ๎˜ต๎˜ƒ๎˜ถ๎˜ค๎˜ฉ๎˜จ๎˜ท๎˜ผ๎˜
๎˜บ๎˜ค๎˜ต๎˜ฑ๎˜ฌ๎˜ฑ๎˜ช๎˜ƒ๎šณ If the information
in this manual is not followed exactly, a fire,
explosion or gas leak may result causing property
damage, personal injury or death.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance!
๎˜บ๎˜ซ๎˜ค๎˜ท๎˜ƒ๎˜ท๎˜ฒ๎˜ƒ๎˜ง๎˜ฒ๎˜ƒ๎˜ฌ๎˜ฉ๎˜ƒ๎˜ผ๎˜ฒ๎˜ธ๎˜ƒ๎˜ถ๎˜ฐ๎˜จ๎˜ฏ๎˜ฏ๎˜ƒ
๎˜ช๎˜ค๎˜ถ๎˜
โ€ข Do not try to light any appliance. Do not touch
any electrical switch; do not use any phone in
your building.
โ€ข Immediately call your gas supplier from a
neighborโ€™s phone. Follow the gas supplierโ€™s
instructions.
โ€ข If you cannot reach your gas supplier, call the fire
department.
Installation and service must be performed
by a qualified installer, service agency or
the gas supplier.
This cooktop has been design certified
by CSA International. Youโ€™ll find safety precautions
in your Ownerโ€™s Manual.
Read them carefully.
โ€ข Installation of this cooktop must conform with
local codes or in the absence of local codes with
the National Fuel Gas Code, ANSI Z223.1/NFPA
54โ€“Latest edition.
โ€ข Be sure your cooktop is installed properly by a
qualified installer or service technician.
โ€ข To eliminate reaching over surface burners,
cabinet storage above burner should be avoided.
โ€ข Do not install the unit near an outside door or
where a draft may affect its use.
๎˜บ๎˜ค๎˜ต๎˜ฑ๎˜ฌ๎˜ฑ๎˜ช๎˜ƒ๎šณ๎˜ƒDisconnect all electrical
power at the main circuit breaker
or fuse box before installing.
2
๎˜ฌ๎™‘๎™–๎™—๎™„๎™๎™๎™„๎™—๎™Œ๎™’๎™‘๎˜ƒ๎˜ฌ๎™‘๎™–๎™—๎™•๎™˜๎™†๎™—๎™Œ๎™’๎™‘๎™–
๎˜ฌ๎˜ฐ๎˜ณ๎˜ฒ๎˜ต๎˜ท๎˜ค๎˜ฑ๎˜ท๎˜ƒ๎˜ถ๎˜ค๎˜ฉ๎˜จ๎˜ท๎˜ผ๎˜ƒ๎˜ฌ๎˜ฑ๎˜ถ๎˜ท๎˜ต๎˜ธ๎˜ฆ๎˜ท๎˜ฌ๎˜ฒ๎˜ฑ๎˜ถ
๎˜จ๎˜ฏ๎˜จ๎˜ฆ๎˜ท๎˜ต๎˜ฌ๎˜ฆ๎˜ค๎˜ฏ๎˜ƒ๎˜ต๎˜จ๎˜ด๎˜ธ๎˜ฌ๎˜ต๎˜จ๎˜ฐ๎˜จ๎˜ฑ๎˜ท๎˜ถ
This appliance must be supplied with the proper
voltage and frequency and connected to an
individual, properly grounded branch circuit,
protected by a circuit breaker or fuse having
amperage as noted on the rating plate.
We recommend you have the electrical wiring and
hookup of your cooktop connected by a qualified
electrician. After installation, have the electrician
show you where your main cooktop disconnect is
located.
Check with your local utilities for electrical codes
which apply in your area. Failure to wire your
cooktop according to governing codes could result
in a hazardous condition.
If there are no codes, your cooktop must be wired
and fused to meet the requirements
of the National Electrical Code, ANSI/NFPA No. 70โ€”
Latest edition. You can get a copy
by writing:
National Fire Protection Association
Batterymarch Park
Quincy, MA 02269
In Canada your cooktop must be wired
and fused to meet the requirements of the
Canadian Electrical Code.
Be sure the installation of this product
in a mobile home conforms with the Manufactured
Home Construction and
Safety Standard, Title 24 CFR, Part 3280.
If this standard does not apply, you must follow
the standard for Manufactured Home Installations,
ANSI A225.1 and Manufactured Home Installations,
Sites and Communities and ANSI/NFPA 501A or
with local codes.
You can get a copy of the Federal Standard by
Writing:
Office of Mobile Home Standards
HUD Building
451 7th Street, S.W.
Washington, D.C. 24010
๎˜ท๎˜ฒ๎˜ฒ๎˜ฏ๎˜ถ๎˜ƒ๎˜ผ๎˜ฒ๎˜ธ๎˜ƒ๎˜บ๎˜ฌ๎˜ฏ๎˜ฏ๎˜ƒ๎˜ฑ๎˜จ๎˜จ๎˜ง๎˜ƒ
๎˜ฉ๎˜ฒ๎˜ต๎˜ƒ๎˜ฌ๎˜ฑ๎˜ถ๎˜ท๎˜ค๎˜ฏ๎˜ฏ๎˜ค๎˜ท๎˜ฌ๎˜ฒ๎˜ฑ
๎˜ฐ๎˜ค๎˜ท๎˜จ๎˜ต๎˜ฌ๎˜ค๎˜ฏ๎˜ถ๎˜ƒ๎˜ผ๎˜ฒ๎˜ธ๎˜ƒ๎˜ฐ๎˜ค๎˜ผ๎˜ƒ๎˜ฑ๎˜จ๎˜จ๎˜ง
๎˜ณ๎˜ค๎˜ต๎˜ท๎˜ถ๎˜ƒ๎˜ฌ๎˜ฑ๎˜ฆ๎˜ฏ๎˜ธ๎˜ง๎˜จ๎˜ง
2 Hold
Down Brackets
Shut-Off ValvePipe Fittings
CSA-Approved Flexible Gas Line
3/8 Min. ID, 1/2 NPT Connection, โ€ณ โ€ณ
3-foot Maximum Length (Massachusetts Only)
Joint Sealant
Saber Saw
Pencil
Safety Glasses
1/8 Drill Bit & Electric or โ€ณ
Hand Drill
Ruler or Straightedge
Foam Tape
2 Screws
Phillips-Head
Screwdriver
Pipe Wrench
3
๎˜ฌ๎™‘๎™–๎™—๎™„๎™๎™๎™„๎™—๎™Œ๎™’๎™‘๎˜ƒ๎˜ฌ๎™‘๎™–๎™—๎™•๎™˜๎™†๎™—๎™Œ๎™’๎™‘๎™–
๎˜ค When preparing cooktop opening, make
sure the inside of the cabinet and the
cooktop do not interfere with each other.
(See section on preparing the opening.)
๎˜ฅ Remove packaging materials, grate boxes,
regulator with literature, and literature
package from the cooktop before beginning
installation.
๎˜ณ๎˜ต๎˜จ๎˜๎˜ฌ๎˜ฑ๎˜ถ๎˜ท๎˜ค๎˜ฏ๎˜ฏ๎˜ค๎˜ท๎˜ฌ๎˜ฒ๎˜ฑ๎˜ƒ๎˜ฆ๎˜ซ๎˜จ๎˜ฆ๎˜ฎ๎˜ฏ๎˜ฌ๎˜ถ๎˜ท
๎˜ฆ Remove Installation Instructions from
literature pack and read them carefully
before you begin.
Be sure to place all literature, Use and Care,
Installations, etc. in a safe place for future
reference.
๎˜ง Make sure you have all the tools and
materials you need before starting the
installation of the cooktop.
๎˜จ Your home must provide the adequate
electrical service needed to safely and
properly use your cooktop. (Refer to section
on electrical requirements.)
๎˜ฉ When installing your cooktop in your home,
make sure all local codes and ordinances
are followed exactly as stated.
๎˜ช Make sure the wall coverings, countertop
and cabinets around the cooktop can
withstand heat (up to 200ยฐF) generated by
the cooktop.
Literature Package
Foam
Packaging
Cooktop
Grate boxes


Produktspezifikationen

Marke: GE
Kategorie: Herde
Modell: JGP329DETCC

Brauchst du Hilfe?

Wenn Sie Hilfe mit GE JGP329DETCC benรถtigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Herde GE

Bedienungsanleitung Herde

Neueste Bedienungsanleitung fรผr -Kategorien-